ZS10-S-R2 Screw Clamp Terminal Blocks Disconnect with lever

Similar documents
ZS4-SF Screw Clamp Terminal Blocks For 5 x 20 fuses

ZS4-SF1 Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses

ZS10-ST Screw Clamp Terminal Blocks Test disconnect with sliding link

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

ZS6-D1-PE Screw Clamp Terminal Blocks Double deck with 1 ground circuit

ZS4-D2-S-T Screw Clamp Terminal Blocks Double deck with 1 disconnect circuit with test socket screws and 1 feed-through circuit

ZS6-3S Screw Clamp Terminal Blocks Feed-through with 3 connections

ZS10-PE Screw Clamp Terminal Blocks Ground

ZS4-D-CH Screw Clamp Terminal Blocks Component holder

ZK2.5-SF-R PI-Spring Terminal Blocks For 5x20 fuses - with blown fuse indicator

ZS6 Screw Clamp Terminal Blocks Feed-through

ZS50-PE Screw Clamp Terminal Blocks Ground

ZS4-PE Screw Clamp Terminal Blocks Ground

ZS35 Screw Clamp Terminal Blocks Feed-through

ZK2.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets

ZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral

ZK2.5-D-CH PI-Spring Terminal Blocks Component holder

ZK4-PE PI-Spring Terminal Blocks Ground

ZK2.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections

ZK6 PI-Spring Terminal Blocks Feed-through

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket

ZS4-S Screw Clamp Terminal Blocks Disconnect with blade

ZK2.5-D1-PE PI-Spring Terminal Blocks Double deck with 1 ground circuit

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

ZS6-4S Screw Clamp Terminal Blocks Feed-through with 4 connections

ZS10 Screw Clamp Terminal Blocks Feed-through

ZS4-T3 Screw Clamp Terminal Blocks Triple deck with 3 feed-through circuits

ZS4-PE Screw Clamp Terminal Blocks Ground

ZS4 Screw Clamp Terminal Blocks Feed-through

ZK4-4P PI-Spring Terminal Blocks Feed-through with 4 connections

ZK2.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections

ZK2.5-PE-4P PI-Spring Terminal Blocks Ground with 4 connections

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

ZS6 Screw Clamp Terminal Blocks Feed-through

ZDP Pluggable Terminal Blocks Feed-through

DBL distribution blocks 3x1 pole

ZP2.5-PE Spring Terminal Block Ground

ZP2.5-4P Spring Terminal Block Feed-through

ZS4-SF1 Screw Clamp Terminal Block

Main catalogue. SNK Series Terminal Blocks Accessories Marking Solutions

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

Main catalog. SNK series Terminal blocks. Phone: Fax: Web: -

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

Electronic overload relay EF65, EF96 and EF146

Electronic overload relays EF205 and EF370

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Thermal overload relay TF140DU and TF140DU-V1000

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

Thermal overload relay TF65 and TF96

Mini contactors B6, BC6 with 3 pole

Thermal Overload Relays

Manual motor starter MS116

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Manual motor starter MS132

MS General Information Extended Product Type: MS

Manual motor starter magnetic only MO325

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

Manual motor starter MS116

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

AF40... AF96 3-pole contactors Technical data

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

DX³ RCCBs - ID 4P up to 100 A

Manual motor starter MS132

Manual motor starter MS132

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Viking 3 - Screw connection Disconnect terminal blocks

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Surge arrester POLIM-H..SD

Voltage limiting device HVL

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

RX 3 M.C.B A up to 63 A

Voltage limiting device HVL

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

Brochure. Motor protection and control DRAS enclosed direct-on-line starters

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

RX 3 M.C.B A up to 63 A

DX³ 4-pole RCBO 6000 A/10 ka

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

ABB i-bus KNX DG/S x DALI-Gateway Basic

Surge arrester POLIM-C.. HD

Phase + Neutral, neutral on left side

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Data sheet. W-Series WDU 4 SL/EN

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

Transcription:

Technical Datasheet SNK6D0 Catalogue Page ZS-S-R2 Screw Clamp Terminal Blocks Disconnect with lever Simplify the disconnect operations for the disconnect terminal blocks installed next to fuse terminal blocks ZS-SF: - With the same profile as ZS- SF, the ZS-S-R2 disconnect lever is easily operated by hand and the wiring of the alternated disconnect and fuse circuits is easier. SNK670F004 SNK0030F0000 3D CAD outline drawings available on "Control Product 3D" portal SNC003 F0000 Screw Clamp Terminal Blocks mm² 6 AWG Ordering Details Color Grey, Orange Grey, Orange 8 mm 0.3 in Spacing Type Order Code EAN Code Pack (ing) Weight ( pce) g ZS-S-R2 SNK0847R0000 3472908473 0 3.90 Declarations and Certificates CE CB RoHS USR CNR CSA EAC BV DNV

Declarations and Certificates CE CE CB CB RoHS RoHS USR CNR USR CNR SND222U* SND690A02* SND2306F02* SND64A02* CSA CSA SND670A02* EAC EAC SND609A* BV DNV BV DNV SND673A02* SND687A02* Explosive Atmosphere: ATEX Classification Group Category Protection Method In the presence of explosive dust atmosphere, terminal blocks are to be installed in certified enclosure II 2D General Information Wire stripping length TH 3-7., TH 3- Denudage IP TH 3-7., TH 3- NEMA Ex e: increased security The following information must be strictly adhered to in order to guarantee the terminal block electrical, mechanical and environmental performance. Protection Rail IEC 60947-3 mm 0.2 in Operating tool Torque Flat screwdriver Tete de viscouple Screw clamp Flat screwdriver 4 mm 0.7 in.3 N.m. N.m ± 0.3 N.m ± 2.6 N.m Screw rail contact (Maximum value) Disconnect device Material Specifications Insulating material CTI Flammability Polyamide 600 V UL94 V0 NF F 6 I2F3 Connecting capacity per clamp Rigid - Solid / Stranded conductor Flexible conductor Flexible conductor with non insulated ferrule Flexible conductor with insulated ferrule Gauge Ferrule maximum outer diameter or conductor insulation maximum outer diameter 0.... mm² 0.... mm² 0.... mm² 0.... 6 mm² A-B IEC 60947- Needle flame testec 606-- Compliant Screw clamp 24... 6 AWG 24... 8 AWG 24... AWG.2 mm 0. in Ferrule 7. mm 0.29 in The "Connecting capacity with ferrule" data is guaranteed with ABB crimping tool PS-3 (crimping capacity up to mm²). 2 Technical Datasheet SNK6D0 ABB

Multi Connecting capacity per clamp 2 Rigid - Solid / Stranded conductors 0.... 4 mm²... 2 AWG 2 Flexible conductors 0.... 4 mm² 2 Flexible conductors with twin ferrule 0.... 4 mm²... 2 AWG Don't mix solid and flexible conductors in the same clamp Don't mix solid or flexible conductors of different sizes in the same clamp The "Connecting capacity with ferrule" data is guaranteed with ABB crimping tool PS-3 (crimping capacity up to mm²) Cross section Rated cross section 4 mm² 2 AWG Maximum Cross section mm² 6 AWG Electrical characteristics Current Rated current A Field and factory wiring Cat.2 UL 9 22 A Factory wiring Cat. UL 9 22 A CSA-C-22.2 n 8 22 A Maximum Exe current IEC/EN 60079-7 Rated short-time withstand current s (Icw) 480 A Short-time withstand current 0. s s s 30 s min Rated short-circuit withstand current UL 9 Max. current (4 temperature increase) / Max. cross section (mm²) 2 A Maximum short circuit current (s) 480 A mm² Short Circuit Current Rating (SCCR) SA UL 9 supplement SCCR UL 9 With the following configurations: Suitable conductor wire range Maximum voltage Fuse class / Max. amp. Rating J T RK RK G CC Voltage Rated voltage IEC 60947-630 V Rated voltage UL 9 600 V Use Group UL 9 B,C Rated voltage CSA-C-22.2 n 8 600 V Rated voltage Ex e IEC/ EN 60079-7 Rated impulse withstand voltage IEC 60947-6000 V Dielectric test voltage IEC 60947-00 V Pollution degree IEC 60947-3 Overvoltage category IEC 60947- III ABB Technical Datasheet SNK6D0 3

Temperature range Ambient temperature min/max Storage -... + C Installing -... +40 C Service -... + C -67... +230 F +23... +4 F -67... +230 F Current Derating curve for continuous service temperature Dissipated power Maximum dissipated power at rated current IEC 60947- Maximum dissipated power at maximum Exe current IEC 60079-7 Rated power dissipation at an ambient temperature of 23 C - IEC 60947-7-3 Separate arrangement / Overload and short-circuit protection Separate arrangement / Exclusive short-circuit protection fuse and 4 feed-through blocks Compound arrangement / Overload and short-circuit protection Compound arrangement / Exclusive short-circuit protection fuse blocks Environmental Characteristics Additional climatic tests Dry heat Cyclic damp heat Cold Damp heat steady state IEC 60068-2 2 Compliant Temperature +0 C 96 h IEC 60068-2 30 Compliant Temperature + C Relative humidity Number of cycles ( cycle = 24h) 2 IEC 60068-2 Compliant Temperature -40 C 96 h IEC 60068-2-78 Temperature Relative humidity Corrosion Salt mist IEC 60068-2 Compliant 96 h Concentration % SO2 ISO 6988 Compliant 48 h Concentration 0.2 dm³ Flowing mixed gas corrosion test IEC 60068-2 60 Number of the test method 4 Technical Datasheet SNK6D0 ABB

Vibrations and shocks Sinusoidal vibrations IEC 60068-2-6 Frequency range Number of cycles Functional random vibrations IEC 6373 Category Class B 3 axes Frequency range Long life testing at increased random vibrations IEC 6373 Category Class B 3 axes Frequency range Shock IEC 6373 Category Class B 3 axes ZS-S-R2 Terminal Block Accessories Compatibility Some accessories may modify the terminal block's rating. See complete information in the accessories catalog page. Description Type Order Code Pack (ing) Weight pieces g ( pce) MG-CPM 3 SNB0479R062 680 0.273 2 2 3 3 4 4 6 End Stops End Stops Test Connectors Test Connectors Test Adapters Test Adapters Spacers MC82 MC82PA UMH SAT8 BAM4 BAZ TC TC-R TP2 TP4 JB8-2 JB8-3 JB8-4 JB8- JB8- ES-TC8 SNK60000R0000 SNK69999R0000 SNK9006R0000 SNK90066R0000 SNK90000R0000 SNK900002R0000 SNK9000R0000 SNK900R0000 SNK9003R0000 SNK900R0000 SNK908302R0000 SNK908303R0000 SNK908304R0000 SNK90830R0000 SNK9083R0000 SNK9004R0000 22 0 0 0 0 0 40.00 4.00 0. 6.00 4.00.30...70 2.40 2.70 4..60 7.00 4..40 ABB Technical Datasheet SNK6D0

Contact us ABB France Electrification Products Division PG Connection 3, rue Jean Perrin F-69687 Chassieu cedex / France Tel. +33 (0)4 7222 722 Fax +33 (0)4 7222 93 Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright ABB All rights reserved SNK6D0 - PDF