TIME-10 Process Control Stopwatch

Similar documents
PY-11 Voltage & Continuity Tester

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

TACH-10 Contact / Non-Contact Tachometer

IR-500 Infrared Thermometer / Voltage Detector / Flashlight

THWD-3 and TH-3 Relative Humidity and Temperature Meters

KMP Insulation-Continuity Tester. Users Manual

TMULD-300 ULD-300. Ultrasonic Leak Detector. Users Manual. 99 Washington Street Melrose, MA Phone Toll Free

TMA5 Mini Vane Anemometer

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

KMP7010. Ground Resistance Tester. Users Manual

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

CM100. Carbon Monoxide Meter. 99 Washington Street Melrose, MA Phone Toll Free

INSP-3 Wiring Inspection Tester

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

CO2-100 CO2 Meter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso

THWD-5. Relative Humidity Temperature Meter. Users Manual. For detailed specifications and ordering info go to

AMB V Insulation Resistance Tester. Users Manual. For detailed specifications and ordering info go to

TMD90A Dual Input Digital Thermometer

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

AC50A. Leakage Clamp Meter. User Manual. For detailed specifications and ordering info go to

365 Detachable Jaw True-rms Clamp Meter

362 Clamp Meter. Users Manual

373 Clamp Meter. Users Manual

302+/303 Clamp Meter. Users Manual

Users Manual. Phase Rotation Indicator

362 Clamp Meter. Users Manual

Operator s Manual TC-253A. Temperature Converter

323/324/325 Clamp Meter

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

233 True-rms Remote Display Digital Multimeter Safety Information

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

Visit us at

716 Pressure Calibrator

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

712 RTD Calibrator. Instruction Sheet. Introduction

i3000s/i2000 Flex AC Current Probe

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:


Users Manual. Airflow Meter

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

Calibration Manual. Detachable Jaw True-rms Clamp Meter

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

Visit us at SOLAR-500. Solar Analyzer. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso

i400s Calibration Information Introduction

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

PK-8270-X/PK-8370-X. Lines and Fittings Kit. Instructions. Introduction. How to Contact Fluke Calibration

Tachometer. English. Users Manual

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

P5510. Users Manual. Pneumatic Comparison Test Pump

1000FLT. Users Manual. Fluorescent Light Tester

PK-VLV-ABORT-100M, PK-VLV-ISO-40M, PK-VLV-ISO-100M

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

Go to to register your product and find more information.

P5514, P5514-V & P5514-EP Hydraulic Comparison Test Pump

719 Series. Pressure Calibrator with Electric Pump. Product Overview (E)

1KV DIGITAL MULTIFUNCTION INSULATION RESISTANCE AND CONTINUITY-VOLTAGE TESTER WITH MOV & GAS ARRESTER TESTING. Model 1154TMF

Infrared Thermocouple Probe

Model P772 Conductivity Meter. User Manual

717 Series. Pressure Calibrators. Instruction Sheet. Introduction

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

Grundfos MAGNA, Relay Module

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

SOIL RESISTIVITY TESTER

718 30G/100G. Users Manual. Pressure Calibrator. 99 Washington Street Melrose, MA Phone Toll Free

(R86049) WARNING: To reduce the risk of injury, the user must read and understand the operator s manual before using this product.

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

KSZ 10B Current Probe Calibrator. Instruction Manual

80PK-2A Type K Immersion Probe

Instruction Manual ICM A1 AC/DC Clamp Meter ICM A1


PolyStat Immersion Circulators

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

Users Manual. MegOhmMeter

OPERATION MANUAL MILLIAMP PROCESS CLAMPMETER MODEL - KM 071 LIST OF PRODUCTS

THERMOCOUPLE CALIBRATOR Mode KM-CAL-710

4-20mA DC PROCESS CLAMP METER

41210S CIRCUIT BREAKER FINDER WITH GFCI Instrucciones de uso Detector de Interruptores con GFCI 41210S. Operating Instructions

KSZ 100B Current Probe Calibrator. Instruction Manual

OWNER'S MANUAL. Royal Sovereign International Inc. RET Desk Series

50 Ft. Retractable Cord Reel

Patron Call System. Scope s DataPage II Lite & NexCall Coaster. Operators/Installation Manual

Temperature Calibrator

Defender 3000 Series Base Instruction Manual

Dawson DSM170 Multi-Function Moisture Meter User s Manual

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

Installation / Operation Instructions Sunnex ORION Series Exam Lights

User s Manual. ClipperCreek, Inc. Innovative Infrastructure for Electric and Hybrid Vehicles. Model PCS-15

P/N# Performance Lowering Springs Installation Instructions

flexible infrared thermometer

INSTRUCTIONS FOR USE. Rx Only

DIGITAL EARTH RESISTANCE Model KM 2030

Hydraulic Bead Breaker Kit

2015 & 2018 Fender Brace Installation Instructions

Loctite Spray Valve Controller Part Number EQUIPMENT Operation Manual

INSTALLATION INSTRUCTIONS

MicroPod Sub User manual / Bedienungsanleitung / Manual del Usario

Installation Instructions. ARS (Amico Rail Systems)

Transcription:

TIME-10 Process Control Stopwatch Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso

TIME-10 Process Control Stopwatch Users Manual English July 2009, Rev.1 2009 Amprobe Test Tools. All rights reserved. Printed in China

Limited Warranty and Limitation of Liability Your Amprobe product will be free from defects in material and workmanship for 1 year from the date of purchase. This warranty does not cover fuses, disposable batteries or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Amprobe s behalf. To obtain service during the warranty period, return the product with proof of purchase to an authorized Amprobe Test Tools Service Center or to an Amprobe dealer or distributor. See Repair Section for details. THIS WARRANTY IS YOUR ONLY REMEDY. ALL OTHER WARRANTIES - WHETHER EXPRESS, IMPLIED OR STAUTORY - INCLUDING IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, ARE HEREBY DISCLAIMED. MANUFACTURER SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. Repair All test tools returned for warranty or non-warranty repair or for calibration should be accompanied by the following: your name, company s name, address, telephone number, and proof of purchase. Additionally, please include a brief description of the problem or the service requested and include the test leads with the meter. Non-warranty repair or replacement charges should be remitted in the form of a check, a money order, credit card with expiration date, or a purchase order made payable to Amprobe Test Tools. In-Warranty Repairs and Replacement All Countries Please read the warranty statement and check your battery before requesting repair. During the warranty period any defective test tool can be returned to your Amprobe Test Tools distributor for an exchange for the same or like product. Please check the Where to Buy section on www.amprobe.com for a list of distributors near you. Additionally, in the United States and Canada In-Warranty repair and replacement units can also be sent to a Amprobe Test Tools Service Center (see address below).

Non-Warranty Repairs and Replacement US and Canada Non-warranty repairs in the United States and Canada should be sent to a Amprobe Test Tools Service Center. Call Amprobe Test Tools or inquire at your point of purchase for current repair and replacement rates. In USA In Canada Amprobe Test Tools Amprobe Test Tools Everett, WA 98203 Mississauga, ON L4Z 1X9 Tel: 877-AMPROBE (267-7623) Tel: 905-890-7600 Non-Warranty Repairs and Replacement Europe European non-warranty units can be replaced by your Amprobe Test Tools distributor for a nominalv charge. Please check the Where to Buy section on www.amprobe.com for a list of distributors near you. European Correspondence Address* Amprobe Test Tools Europe In den Engematten 14 79286 Glottertal, Germany Tel.: +49 (0) 7684 8009-0 *(Correspondence only no repair or replacement available from this address. European customers please contact your distributor.)

TIME-10 Process Control Stopwatch 2 1 3 AM TU 4 1 2 3 4 Split / Reset Button Mode Button Start / Stop Button Display Screen (LCD)

CONTENTS SYMBOLS... 2 UNPACKING AND INSPECTION... 2 INTRODUCTION... 2 OPERATION... 3 SPECIFICATIONS... 4 MAINTENANCE AND REPAIR... 5 1

SYMBOLS W Caution! Refer to the explanation in this Manual ; Conforms to relevant Australian standards P = Complies with European Directives Do not dispose of this stopwatch as unsorted municipal waste. Contact a qualified recycler for disposal. WWARNING and PRECAUTIONS Do not operate the stopwatch in explosive gas (material), combustible gas (material) steam or filled with dust. Unpacking and Inspection Your shipping carton should include: 1 TIME-10 Process control stopwatch 1 Battery (Installed) 1 Users manual If any of the items are damaged or missing, return the complete package to the place of purchase for an exchange. INTRODUCTION Optimize process phases by analyzing and precisely timing each task. When improving process flow, verify improvement times and cost savings on production floors or assembly lines with precise stopwatches. Chronograph: 1/100 stop watch, split/lap time Time display: hour, minute, second, day, week day, month and year Alarm function Hourly chime Water resistant 2

Operation B A C FUNCTION READING Normal display Hour, minutes, second and day of the week Push A Alarm time Push B Mode Push C Month, date, day of the week STOP FUNCTION Push B for stop function Push C for count & stop Push A for lap & reset ALARM & CHIME ON / OFF Chime is auto-built-in into the IC, no more chime flag is required. In normal time hold A then push C Alarm flag appears alarm on/alarm flag disappears, alarm off ALARM TIME SETTING Press B, 2 times makes hour flashing, press C to advance Push A again to make minute flashing, press C to advance Push B, 1 time back to normal time 3

NORMAL TIME SETTING Press B, 3 times then push A once to make flashing of minute, push C to advance Press A again to make flashing of hour, push C to advance Repeat the sequence until the week days to be set, then press B once back to normal time. Select 12/24 hour cycle option in normal time Press B, 3 times, then A, 2 times so that hour is flashing, press C to advance 1 cycle to select 12/24 hour, after selected, press B 1 time back to normal time. SPECIFICATIONS Range : 0.00~10.00ppt, 10.1~70.0ppt Resolution : 0.01ppt or 0.1ppt Normal Time : Days, Month, Date, Hour, Minute, Second, AM/PM, 12/24 Hours, Alram Sign Hourly Chime Alarm Time : Hour, Minute, Alram Sign Hourly Chime Chronograph : 1/100 Stop watch, Max Count: 50:59 (Minute : Second) (99/100Sec) Water Resistant : Yes Dimensions : 65(L) x 56(W) mm (2.56 x 2.20 in) Weight : Approx. 47 g ( 0.10 lb) Battery : LR44 Compliance : Complied with CE Regulation 4

MAINTENANCE AND REPAIR If there appears to be a malfunction during the operation of the stopwatch, the following steps should be performed in order to isolate the cause of the problem. 1. When readout becomes dim or no displays, it is time to replace the battery, remove the back cover by loosening the screw and replace with Toshiba LR44. 2. Review the operating instructions for possible mistakes in operating procedure. Except for the replacement of the battery, repair of the meter should be performed only by a Factory Authorized Service Center or by other qualified instrument service personnel. The front panel and case can be cleaned with a mild solution of detergent and water. Apply sparingly with a soft cloth and allow to dry completely before using. Do not use aromatic hydrocarbons or chlorinated solvents for cleaning. 5