VAD Variable Area Desuperheaters

Similar documents
Direct Contact Desuperheaters

Direct Contact Desuperheaters

IBV Series C-LF2 Carbon Steel Inverted Bucket Vertical Steam Trap

Fig B34 Carbon Steel 'T' Type or Basket Type Strainers

BCV Blowdown Control Valves DN15 to DN50 (½" to 2")

DESUPERHEATER (SERIES 800)

YARWAY NARVIK MODEL 88 SPID SMALL PIPE INLINE DESUPERHEATER

M21Hi ISO Reduced Bore Ball Valve DN15 to DN150 Flanged PN40

PV4 and PV6 Piston Valves

NARVIK-YARWAY. Heavy Duty A.T. - Temp Desuperheater Model: 18/54 and 28/64

GVK Series (Steam-to-Steam) Clean Steam Generators

YARWAY NARVIK VEN-TEMP DESUPERHEATER MODEL 25

ABV21i and ABV40i Air Actuated Boiler Blowdown Valves

Yarway Narvik Ven-Temp Desuperheater Model 25

Pilot Operated Pressure Reducing Valves with Stainless Steel Bodies

CE43 1" (DN25) to 4" (DN100) Carbon Steel Cage Design, Two Port Control Valves

M21Fi ISO Ball Valve DN15 to DN150

M21Fi ISO Reduced Bore Firesafe API607 Ball Valve DN15 to DN150 Flanged PN40

M21Ti ISO Reduced Bore Ball Valve for the Tobacco Industry DN15 to DN150 Flanged PN40

Standard Duty A.T.S.A. - Temp Desuperheater Model 24 / 34

MFP14, MFP14S and MFP14SS Automatic Pumps

Pilot Operated Pressure Surplussing Valve with Cast Steel Body

AEL5 Series Electric Linear Actuators for DN15 to DN100 Control Valves

SPIRA-TROL Two-port Control Valves ASME Standard KEA, KFA and KLA ½" to 8"

Yarway Narvik Desuperheater Model 18/54 and 28/64 Heavy Duty

PF6 Stainless Steel Piston Actuated On/ Off Valves

SCA Series Steel Inverted Bucket Steam Traps

Two port valves. pneumatically actuated

PF6 Stainless Steel Piston Actuated On/Off Valves

DP163, DP163G and DP163Y Pilot Operated Pressure Reducing Valves with Stainless Steel Bodies

m-csg Ultra-compact Clean Steam Generation System

M10Si ISO Ball Valve DN¼" to DN2½"

SPIRA-TROL 1/2" to 4" ANSI Two-port KEA, KFA and KLA Control Valves

DP143, DP143G and DP143H. Pilot Operated Pressure Reducing Valves with Cast Steel Bodies

Heavy Duty Que - Temp Desuperheater Model: 13 / 23

SPIRA-TROL 1/2" to 4" ANSI Two-port LEA, LFA and LLA Control Valves

FLOW TEK VALVES & CONTROL S INC

SEMPELL TURBINE BYPASS VALVE MODEL 115 CHP

DP143, DP143G and DP143H. Pilot Operated Pressure Reducing Valves with Cast Steel Bodies

STERI-TROL Clean Service 'S' series Two-port and Three-port Control Valves - DN15 (½") to DN100 (4")

FT47 SG Iron Ball Float Steam Traps (DN15 to DN50)

YARWAY NARVIK STANDARD DUTY A.T.-TEMP DESUPERHEATER MODEL 38/48

Standard Duty Que - Temp Desuperheater Model: 33 / 43

Spira-trol TM Two-port Control Valves EN Standard LE, LF and LL DN15 to DN100 and ASME Standard LEA, LFA and LLA ½" to 4"

Series DK. Type DKV. Desuperheaters to control the Temperature of Superheated Steam (or Gas)

YARWAY NARVIK MODEL 33/43 STANDARD DUTY QUE-TEMP DESUPERHEATER

SPIRA-TROL. DN15 to DN50. LE, LF and LL Two-port Control Valves

M10F Ball Valve DN¼" to DN2½"

Series DK Type DKV and DKM

SDP143 Pilot Operated Pressure Surplussing Valve with Cast Steel Body

Globe Control Valves

LESLIE DESUPERHEATERS SIZES 1/2" 16" ANSI Class 150 to 2500

S and SF Series Cast Iron Inverted Bucket Steam Traps

3-port valves. pneumatically actuated

MNSD-V MULTIPLE NOZZLE SPRAY DESUPERHEATER BULLETIN 1144 APRIL 2004

VELOCITY CONTROL TECHNOLOGY DESUPERHEATERS

SVL488 Stainless Steel Safety Valve for Clean Service Applications

Fisher DFA Variable Geometry Desuperheater

Standard Duty A.T.-Temp Desuperheater for cryogenic processes

MNSD-V MULTIPLE NOZZLE SPRAY DESUPERHEATER BULLETIN 1144 SEPTEMBER 2001

PRESSURE REDUCING AND DESUPERHEATING STATIONS SERIES

Standard Duty SLN - Temp Desuperheater Model: 50 / 60

'C' Series Control Valves

Pressure Reducing and Desuperheating Valves

SAMSON 3281 & Steam Converting Valves SMART IN FLOW CONTROL

Horizontal Pre-Piped Bladder Tanks with Proportioner

Yarway Narvik Model 37 and 47 Cryogenic injector

Fisher DMA, DMA/AF, and DMA/AF HTC Mechanically Atomized Desuperheaters

Worcester 18/19 Series. Modular Multi-Way Ball Valves

10000 SERIES. Steam Desuperheater With Spray Nozzles

Hopkinsons CONTENTS SCHEDULE OF SHELL BOILER MOUNTINGS. Hopkinsons. Safety Valves 5. Boiler Stop Valves 17. Feed Check Valves 18. Blowdown Valves 20

STEAM TURBINE BY-PASS AND STEAM CONDITIONING VALVE

YARWAY NARVIK MODEL 60/70 STANDARD DUTY SLN-TEMP DESUPERHEATER

DCV1, DCV2 and DCV3 Disc Check Valves Installation and Maintenance Instructions

Vertical Pre-Piped Bladder Tanks with Proportioner

Series 240 Type and Type Pneumatic Control Valves Type 3244 Three-way Valve

TempLowHT Steam Desuperheater Model: 59/69/79

MNSD-V & MNSD-U. Multiple Nozzle Spray Desuperheater

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

EL5600 Series Electric Actuators for DN15 to DN100 Valves

APPLICATIONS IN PALM OIL MILL - CONTROL VALVE - DESUPERHEATER -PRDS -FLOWMETER -GAUGES

SERIES DESUPERHEATERS

SPIRA-TROL. ½" to 4" ASME (ANSI) Two-port KEA, KFA and KLA Control Valves

Types PN5000 and PN6000 Series Pneumatic Actuators Installation and Maintenance Instructions

Spiratec ST14, ST16 and ST17 Sensor Chambers and Sensors

Model MTB-ASME Vertical Pre-Piped Bladder Tanks

DEP7 SG Iron Excess Pressure Valve

GATE VALVES S 38 APPLICATION

DRAG VLN Turbine Bypass Valve for Hot Reheat Bypass Applications

Model MTB-ASME Horizontal Pre-Piped Bladder Tanks

General Stem-Guided Control Valves

VLM20 In-line Vortex Flowmeter

Direct Steam Converting Valves Model DSCV-SA

General Stem-Guided Control Valves

Combi valves PN 16 with flanged connections

PRODUCT PORTFOLIO VALVES

Spiraflo Steam flowmeters

T EN Type 3347/3379 Pneumatic Control Valve Type 3347 Hygienic Angle Valve

Series 240 Type and Type Pneumatic Control Valves Type 3347 Hygienic Angle Valve

AEL5 Series Electric Linear Actuators for ½" to 4" Control Valves

Transcription:

Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without notice. Copyright 2016 TI-P451-01 CH Issue 3 Variable Area Desuperheaters Desuperheater overview Steam used in process plants can be superheated, that is, heated to a temperature above saturation. The excess of temperature above its saturation is called 'superheat'. Desuperheated steam is more efficient in the transfer of thermal energy, consequently desuperheaters are used to bring the outlet steam temperature closer to that of saturation for the steam pressure. Desuperheaters reduce the temperature of superheated process steam by introducing finely atomised cooling water droplets into the steam flow. As the droplets evaporate, sensible heat from the superheated steam is converted into latent heat of vaporisation. As standard the is supplied with an actuator. The following optional extras can be supplied if requested when placing an order: Positioner, Regulator and Limit switch. A typical desuperheater installation is shown below: 1st stop valve Strainer Check valve 2nd stop valve Note: These anciliaries are not delivered with and should be purchased separately Required to isolate the system from inlet water. Required with 100 mesh screen to maintain the water supply in a condition that wont block the desuperheater nozzles. Required to prevent steam from flowing back into the water inlet - The prefered selection would be an LCV lift check valve as it will give optimum performance in this application. Required to isolate the system for maintenance. PN9400 series actuator Water Strainer Check valve PN9000 series actuator in conjunction with a PN9000 series actuator in conjunction with a PN9400 series actuator 1st Stop valve + PN9000 series actuator 2nd Stop valve a : 30 mm travel Kv 0.1 to Kv 1.4 For applications that require a higher Kv use a b Temperature sensor b : 70 mm travel for applications that require a higher Kv of between: Kv 1.8 to Kv 4.0 Position of nozzles Steam flow 6 m A typical installation illustrating a variable area desuperheater in conjunction with a PN9000 series actuator Page 1 of 7

General description Spirax Sarco variable area desuperheaters reduce the temperature of superheated steam by spraying atomised water through a variable area nozzle, producing near-saturated steam for a wide steam turndown ratio (max 50:1). There are two options available depending on the Kv value and control rangeability required for the application. a in conjunction with a PN9000 series actuator 30 mm travel Kv 0.1 to Kv 1.4 b in conjunction with a PN9400 series actuator 70 mm travel Kv 1.8 to Kv 4.0 Description The a variable area desuperheater has been designed to perform between a Kv of 0.1 to Kv 1.4 The main advantages of the Spirax Sarco is its full modularity, as the components can be adjusted to meet each individual application needs; on site if needed. The nozzle can also be replaced to accommodate a change in flow requirement. The cooling water is atomised through a number of nozzles which are successively opened by the linear movement of a plug controlled by the actuator. As standard, it is designed and coupled with the PN9000 Series actuator 30 mm travel. The steam branch line connection is DN80 as standard, but could be customised at the required dimension. The water connection is DN25 as standard, but could be customised. The standard dimensional lengths of the top and bottom pipe extensions of the desuperheater, as well as the position of the water connection are shown on page 5, but please note that theses can be customised to meet any specific application to meet your needs. Description As standard, the b is designed to and coupled with the PN9400 Series actuator. The water atomisation is done through up to 18 nozzles which are successively opened with the linear move of the plug. The steam branch line connection is DN80 as standard, but could be customised at the required dimension. The water connection is DN25 as standard, but could be customised or increased for a higher Kv than 4. The standard dimensional lengths of the top and bottom pipe extensions of the desuperheater, as well as the position of the water connection are shown on page 5, but please note that theses can be customised to meet any specific application to meet your needs. Page 2 of 7

Typical applications: - To reduce the temperature of steam discharged from turbine by-pass systems on power plants for heat exchangers, dump stations etc. - To improve heat transfer of indirect contact heat exchangers - shell and tube, plate type, reactor heating jackets etc. - To reduce the temperature of steam on direct contact applications - food cooking kettles, in-line steam heaters, tobacco drying plant and paper mills. Features: - Low cost simple, robust design. - Minimal steam pressure drop. - Flexible design options. Standards and approvals Spirax Sarco desuperheaters are available built to ASME B 16.34 design code. Also available are ASME VIII Division 1. This product fully complies with the requirements of the European Pressure Equipment Directive 97 / 23 / EC and carries the CE mark when so required. Welding is in accordance with ASME IX. Connections (EN 1092 or ASME B16.5) are sized to suit the process conditions. Standard ASTM materials of construction include: Carbon steel, Stainless steel, Chrome molybdenum steel etc., Certification The following certificates / documents can be supplied at an additional cost: - Material certificates to EN 10204 3.1 with a corresponding material location diagram. - NDT reports. Air signal The lift should be controlled by use of a positioner, the maximum air pressure on the actuator should be limited to 4 bar g. The fail safe position of the standard unit is in the shut off position, spring-retact and will shut off water when retracted. Optionally, if request at the point of order, the unit can be supplied in the fail safe open position and the unit nomenclature will be denoted by an 'E' (for spring-extend) in the description i.e. a E. Positioners Compatible with PP5, EP5, ISP5, SP400 and SP500 positioners. Material No. Part Material 1 Nozzle Stainless steel AISI 431 2 Seat Stainless steel AISI 431 3 Plug Stainless steel 4 Lock-nut Stainless steel 5 Stem Stainless steel AISI 431 6 Bottom pipe extension Carbon steel 7 Main steam flange Carbon steel ASTM A105N 8 Water flange Carbon steel ASTM A105N 9 Top pipe extension Carbon steel ASTM A105N 10 Packing Graphite 11 Packing bolting Stainless steel 12 Nut Stainless steel 13 Setting nut Stainless steel 14 Seat gasket Graphite 15 Stem bearing Stellite Grade 6 8 9 7 6 5 4 3 2 1 12 11 10 15 14 13 Alternative material: Depending of the condition of use, Spirax Sarco can could change the carbon steel body material to alloy steel or stainless steel. Please note: The parts identified in the illustration above are exactly the same for both the a and the b Page 3 of 7

Pressure / temperature limits: The Spirax Sarco variable area desuperheater has a carbon steel body as standard but can be produced in any material grade to special order. '4' denotes a carbon steel desuperheater '6' denotes an austenitic stainless steel desuperheater '8' denotes an alloy steel desuperheater Please note that the pressure and temperature limits for the product range is governed by the flange connection of choice: 4 6 (316) 8 (A182 F11 Cl.2) Flanges PMA bar g @ C TMA C @ bar g ASME 150 19.6 @ 38 C 425 C @ 5.5 ASME 300 51.5 @ 38 C 425 C @ 28.8 ASME 600 102.1 @ 38 C 425 C @ 57.5 ASME 900 153.2 @ 38 C 425 C @ 86.3 ASME 1500 255.3 @ 38 C 425 C @ 143.8 ASME 2500 425.5 @ 38 C 425 C @ 239.7 PN40 40.0 @ 50 C 400 C @ 23.8 PN63 63.0 @ 50 C 400 C @ 37.5 PN100 100.0 @ 50 C 400 C @ 59.5 PN160 160.0 @ 50 C 400 C @ 95.2 PN250 250.0 @ 50 C 400 C @ 148.8 PN320 320.0 @ 50 C 400 C @ 190.4 PN400 400.0 @ 50 C 400 C @ 238.0 ASME 150 19.0 @ 38 C 538 C @ 1.4 ASME 300 49.6 @ 38 C 538 C @ 25.2 ASME 600 99.3 @ 38 C 538 C @ 50.0 ASME 900 148.9 @ 38 C 538 C @ 75.2 ASME 1500 248.2 @ 38 C 538 C @ 125.5 ASME 2500 413.7 @ 38 C 538 C @ 208.9 PN40 40.0 @ 100 C 580 C @ 25.0 PN63 63.0 @ 100 C 580 C @ 39.5 PN100 100.0 @ 100 C 580 C @ 62.7 PN160 160.0 @ 100 C 580 C @ 100.3 PN250 250.0 @ 100 C 580 C @ 156.7 PN320 320.0 @ 100 C 580 C @ 200.6 PN400 400.0 @ 100 C 580 C @ 250.8 ASME 150 19.8 @ 38 C 538 C @ 1.4 ASME 300 51.7 @ 38 C 538 C @ 14.9 ASME 600 103.4 @ 50 C 538 C @ 29.8 ASME 900 155.1 @ 50 C 538 C @ 44.7 ASME 1500 258.6 @ 50 C 538 C @ 74.5 ASME 2500 430.9 @ 50 C 538 C @ 124.1 PN40 40.0 @ 300 C 490 C @ 27.2 PN63 63.0 @ 300 C 490 C @ 42.8 PN100 100.0 @ 300 C 490 C @ 68.0 PN160 160.0 @ 300 C 490 C @ 108.8 PN250 250.0 @ 300 C 490 C @ 170.0 PN320 320.0 @ 300 C 490 C @ 217.6 PN400 400.0 @ 300 C 490 C @ 272.0 Page 4 of 7

Dimensions / weights (approximate) in mm and kg Dimensionally there are two versions available the 'Standard' and the 'L' version for use on larger pipelines of 300 mm. Please note that the dimensions in brackets ( ) are for the 'L' version. Weights a b 35 kg 70 kg 465 390 742 332 * 80 158 281 * Please note: This dimension becomes 100 mm when the flange is greater than 25 mm or the pressure is greater than A600 / PN100. * 80 158 281 332 (540) 372 (580) 352 (590) 412 (650) 33.5 33.5 60 60 a b Please note - Nozzles When installing the into its application the nozzles must face towards the direction of the steam flow. To suit the layout of the water pipeline, the inlet water flange is available in 4 different locations, please see the orientation diagram below: Orientation Left Upstream Right Downstream Steam line Water connection orientation by default Page 5 of 7

Safety information, installation and maintainance For full details see the Installation and Maintenance Instructions that are supplied with the product. Installation note: Desuperheaters may be installed either horizontally or vertically with the steam flowing upwards. Spirax Sarco strongly advises against installations in which the steam flow is vertically downwards. In the case of a horizontal installation the cooling water connection should ideally point downstream, as this gives the best orientation for drainage of fluids in a shutdown situation. Other orientations are acceptable for satisfactory operation, but drainage is not as effective. In a vertical installation we recommend that, the cooling water pipework should be brought to the desuperheater from below the corresponding connections on the desuperheater. This will provide the best layout for drainage of fluids on shutdown. The must be sited in location on the pipeline that offers a stable flow - An unstable flow will affect the mixing efficiency of the. + PN9000 series actuator Temperature sensor Installation depends on the application Position of nozzles Steam flow 6 m A typical installation illustrating a variable area desuperheater in conjunction with a PN9000 series actuator The temperature sensor should be located a minimum distance of calculated on the sizing sheet (and typically more them 12m) after the, however for optimum temperature control it is recommended that it be installed at the point of use. A minimum length of 5 metres should be present before a pipe elbow. A thermal sleeve is recommended to protect the elbow from corrosion and erosion. The steam pipeline should be of at least DN150. At steam line sizes up to and including 20" NB, we recommend the thermal sleeve is manufactured from pipe which is one size smaller than the steam line. Above 20" NB steam line size, we recommend the thermal sleeve is two sizes smaller. Pipe size should ensure a minimum 5m/s velocity in each flowrate, in case of lower value please contact Spirax Sarco Water must be supplied with more than 3 bar differential pressure to the steam. Disposal The product is recyclable. No ecological hazard is anticipated with disposal of this product, providing due care is taken. The location of the in the pipeline must be such that it offers a stabilised flow. Unstabilised flow will affect the mixing efficiency. The must be sited in location on the pipeline that offers a stable flow - Unstabilised flow will affect the mixing efficiency. Page 6 of 7

How to order Please send the following process data to Spirax Sarco so that we can select the optimum solution for your application. Minimum information required to size the desuperheater: - Maximum and minimum superheated steam condition (Pressure, temperature and flowrate). - Required outlet steam temperature. - Available water condition (Pressure and temperature). Pressure Minimum Nominal Maximum Superheated steam Temperature Flow Steam outlet Water Temperature Pressure Temperature Additional information Please state if you require any of the following, the number(s) required and nomenclature if known: Positioner(s) Air regulator(s) Limit switch(s) Further information, that if supplied, will help in selecting the optimal solution for your application: Design pressure Design temperature Superheated steam size Required flanged desuperheaters flange Required flanged water flange Fail safe position - Specify either Open or Closed Selection chart Turndown 1:1 2:1 3:1 4:1 5:1 7:1 10:1 30:1 50:1 : Variable desuperheater TSAT + 5 C Minimum water pressure : Steam + 3 bar Kv table Desuperheater a b Travel 30 mm 70 mm Rangeability 1 : 20 1 : 40 Maximum turndown 50 : 1 50 : 1 Kv standard Note: For lower or higher Kv please contact Spirax Sarco 1.40 4.0 1.00 3.7 0.60 3.3 0.54 2.9 0.45 2.5 0.40 2.1 0.20 1.8 0.10 Page 7 of 7