Performance Summary Voltage Current Power Frequency Power Factor Current THD A W Total Luminous Flux

PHONE: (303) FAX: (970) WEBSITE:

LED Warehouse Industrial Lighting - 2 Ft Compact High Bay SPEC SHEET

PHONE: (303) FAX: (970) WEBSITE:

S BERGIN R BEATTIE Lighting Engineer. Checked Approved

PHONE: (303) FAX: (970) WEBSITE:

Test Sample Description Catalog Number: Description:

PHONE: (303) FAX: (970) WEBSITE:

LED Black Housing High Output Remote Capable

Performance Summary Voltage Current Power Frequency Power Factor Current THD A W Total Luminous Flux

Test Sample Description Catalog Number: Description:

PHONE: (303) FAX: (303) WEBSITE:

NVLAP LAB CODE:

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

Number Eight Lighting Company 803/K2-HI-15-XX/DIM /FS-P-1-WH

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York AveWest Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

LIGHT EFFICIENT DESIGN

Test Sample Description Catalog Number: Description:

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

Test Sample Description Catalog Number: Description:

NVLAP LAB CODE:

NVLAP LAB CODE LM Test Report. For. MaxLite lnc. (Brand Name: MaxLED) 12 York Ave West Caldwell NJ 07006,USA

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

NVLAP LAB CODE LM Test Report For. Model Different: All construction and rating are the same, except CCT

LIGHT EFFICIENT DESIGN, LLC

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

LM Test Report. LIGHT EFFICIENT DESIGN (Brand Name:N/A) LED Luminaire

IES INDOOR REPORT PHOTOMETRIC FILENAME : LHB K-U80-UNI.IES. DESCRIPTION INFORMATION (From Photometric File)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

Osram Sylvania 200 Ballardvale Street Wilmington, Mass

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Lisun Electronics Inc. Tel:+86(21)

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: N/A) 12 York Ave, West Caldwell, NJ 07006

LIGHT LABORATORY, INC E Kaiser Blvd. Anaheim, CA 92808

Calibration Due Date Chroma Programmable AC Source 61604

Photometric Test Report. MaxLite Inc 10 York Avenue, West Caldwell, NJ Ramesh Raghavan, x146,

NVLAP LAB CODE LM Test Report. For. MLS CO., LTD (Brand Name: MLS) NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN, GUANGDONG CHINA

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDUCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

IES INDOOR REPORT PHOTOMETRIC FILENAME : 4A_ASD-LVP10M-4N3135-PRM_IES.IES. DESCRIPTION INFORMATION (From Photometric File)

Lisun Electronics Inc. Tel:+86(21)

Photometric Indoor Test Report

Integrating Sphere Test Report

Wet Locations Use. RoHS. Model: VAC / 28 W PF LM 93 LM/W. Alluminium + Tempered Glass 24-45VDC 0.

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Integrating Sphere Test Report

PHOTOMETRIC TESTING & EVALUATION. Sample Tested Man-D-Tec UNILED-12-4K. Prepared for: Man-D-Tec 8175 E. Paradise Lane Scottsdale, AZ 85260

IES INDOOR REPORT PHOTOMETRIC FILENAME : C6R UNVE5-35-LG.IES. DESCRIPTION INFORMATION (From Photometric File)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

Integrating Sphere Test Report

NVLAP LAB CODE LM Test Report. For SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED)

IES INDOOR REPORT PHOTOMETRIC FILENAME : VW4-LED48DMVSSF50.IES. DESCRIPTION INFORMATION (From Photometric File)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO.,LTD. (Brand Name: SEPICN LED LIGHTING)

Lighting Sciences

NVLAP LAB CODE LM Test Report. For SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED)

Photometric Test Report. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. Mohit K Mittal, ,

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO.,LTD. (Brand Name: SEPICN LED LIGHTING)

Wet Locations Use VAC / 79 W PF LM 92 LM/W. Alluminium + Tempered Glass 25-42VDC 1.95A 88% CXA PCS

Catalog Number UPC Number Features. General Lumen Output: 2300 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA 92503

Catalog Number UPC Number Features. General Lumen Output: 800 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black

Transcription:

Report of Test LLIA000901-025 Total Light Output Luminaire Power Luminous Efficacy Performance Summary 1605 lm 24.6 W 65.2 lm/w PREPARED FOR : Lumetta, Inc, 33 Minnesota Avenue, Warwick, RI 02888, USA Page 1 of 6

Legend: All planes - Black (cd) 150 120 INTENSITY SUMMARY (cd) All Flux Flux Gamma Planes (lm) Gamma C0 (lm) 0 262 90 52 5 263 25 95 53 59 10 265 100 60 15 262 74 105 71 75 20 255 110 83 25 247 114 115 95 94 90 30 236 120 108 35 224 140 125 120 107 40 211 130 132 45 197 152 135 142 110 50 181 140 152 55 161 144 145 160 100 150 60 141 150 168 65 119 118 155 175 81 70 98 160 180 60 75 76 81 165 184 52 80 60 170 185 85 56 61 175 183 17 30 90 52 180 182 300 (Rotational symmetry) ZONAL FLUX AND PERCENTAGES AVERAGE LUMINANCE (cd / m^2) Zone Flux (lm) %Lamp %Luminaire Gamma C0 0-30 213 N / A 13.3 45.0 312 0-40 353 N / A 22.0 55.0 274 0-60 649 N / A 40.5 65.0 227 0-90 909 N / A 56.7 75.0 170 40-90 556 N / A 34.7 85.0 157 60-90 260 N / A 16.2 90-180 695 N / A 43.3 0-180 1605 N / A 100.0 Total Light Output = 1,605 lm Signed: Spacing Criterion: 0-180 1.3 Spacing Criterion: 90-270 1.3 Authorized Signatory Date of test 8-Jan-2018 Date of report 12-Jan-2018 Page 2 of 6

Intensity (cd) and Flux (lm) data Gamma Intensity Flux Gamma Intensity Flux 0.0 262 90.0 52 2.5 261 92.5 52 5.0 263 25 95.0 53 59 7.5 265 97.5 56 10.0 265 100.0 60 12.5 264 102.5 65 15.0 262 74 105.0 71 75 17.5 259 107.5 77 20.0 255 110.0 83 22.5 251 112.5 89 25.0 247 114 115.0 95 94 27.5 242 117.5 101 30.0 236 120.0 108 32.5 230 122.5 114 35.0 224 140 125.0 120 107 37.5 218 127.5 126 40.0 211 130.0 132 42.5 204 132.5 137 45.0 197 152 135.0 142 110 47.5 189 137.5 147 50.0 181 140.0 152 52.5 171 142.5 156 55.0 161 144 145.0 160 100 57.5 151 147.5 164 60.0 141 150.0 168 62.5 130 152.5 171 65.0 119 118 155.0 175 81 67.5 109 157.5 178 70.0 98 160.0 180 72.5 87 162.5 182 75.0 76 81 165.0 184 52 77.5 67 167.5 185 80.0 60 170.0 185 82.5 57 172.5 184 85.0 56 61 175.0 183 17 87.5 54 177.5 181 90.0 52 180.0 182 Page 3 of 6

Test Number: LLIA000901 025 One ERP ESS030W 0620 42 LED driver Coefficients Of Utilization Zonal Cavity Method Effective Floor Cavity Reflectance 0.20 RC 80 70 50 30 10 0 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 0 109 109 109 109 101 101 101 101 87 87 87 74 74 74 62 62 62 57 1 98 93 88 84 91 86 82 79 74 71 69 63 61 59 53 51 50 45 2 89 80 73 68 82 75 69 64 64 60 56 55 51 48 46 43 41 36 3 80 70 62 56 74 65 58 53 56 51 46 48 44 40 40 37 34 30 4 73 62 53 47 68 58 50 44 50 44 39 42 38 34 35 32 29 25 5 67 55 46 40 62 51 43 38 44 38 33 38 33 29 32 28 25 22 6 62 49 40 34 57 46 38 33 40 34 29 34 29 25 29 25 22 19 7 57 44 36 30 53 41 34 28 36 30 25 31 26 22 26 22 19 17 8 53 40 32 26 49 38 30 25 33 27 22 28 23 20 24 20 17 15 9 49 37 29 23 46 34 27 22 30 24 20 26 21 18 22 18 15 13 10 46 33 26 21 43 31 25 20 28 22 18 24 19 16 20 17 14 12 For absolute test reports, CUs are expressed as a percentage of total lumen output. Calculations were based on published IES procedures, and are based on the zonal cavity method. Basic assumptions: 1) Room surfaces are lambertian reflectors. 2) Incident flux on each surface is uniformly distributed. 3) The room is spectrally neutral. When luminaires are not evenly distributed throughout the room, or do not exhibit lateral symmetry, CU values may differ from actual performance. Circle of Light Plot Height(ft) Beam Width (across 50% Nadir Illum) Illuminance at Nadir (fc) 0 180 90 270 6.0 7.3 8.00 8.00 8.0 4.1 10.67 10.67 10.0 2.6 13.33 13.33 12.0 1.8 16.00 16.00 14.0 1.3 18.66 18.66 16.0 1.0 21.33 21.33 Page 4 of 6

Page 5 of 6

Test Distance 9.5 m Test Temperature 24.6 C Notes The laboratory has not participated in the selection of samples to be tested. All testing is performed on the understanding that the significance of the report is limited to the extent that the test sample is representative of production units. Tested in accordance with the applicable sections of publications: IES LM-79-08 (Sec. 12), IES LM-16-93, IES LM-58-13, CIE 13.3:1995, CIE 15:2004, ANSI C78.377:2015, ANSI C82.77-10:2014. The luminous intensity values, and other derived quantities, contained in this report are based on the absolute data, as measured. Prorating the performance of the sample for the use of other component combinations (such as lamp / LED / Ballast / driver), or for use in different environmental conditions than that tested, may produce erroneous results. This report is free of erasures and corrections. Photometric intensity values are reported using the CIE Gamma coordinate system as defined in CIE publication number 121. This report may contain data that are not covered by the NVLAP accreditation. Quantities marked with * are not covered. This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST, or any agency of the Federal Government. 12-Jan-18 11:01:02 REPORT program version: 3.820a Page 6 of 6