Installation- and Operating Instructions. SAUNA exclusiv 9kW. Sauna control 400V. Art.Nr Function:

Similar documents
.3 Section Waste Management and Disposal.

TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH. 30m 3 /h

The electro-mechanical power steering with dual pinion

Visit for more technical information & downloads

TECHNICAL SPECIFICATION OF THERMAL PROTECTOR, ST-22

Power Electronics. MINISTOP Motor Brake Relay BA 9034N

ADDITIONAL EMERGENCY POWER SUPPLY DEVICES

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

ELECTRONIC CONTROL ACTUATOR

Operating Instructions Bedienungsanleitung Mode d emploi EWB EWB

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

ELECTRONIC CONTROL ACTUATOR

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

ELECTRONIC CONTROL ACTUATOR

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Instructions for the BCEA Rotary heat exchanger

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

Demag KB conical-rotor brake motors. Drives with unique principle

UP100AC INSTRUCTION MANUAL

Products Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0

AIR CONDITIONING AIR COOLED CONDENSERS

Documentation. RM-BV4 Micro DP. Filter control

INDUSTRIAL CHARGER AUTOMATIC BATTERY CHARGER SERIES 150 KUSSMAUL ELECTRONICS CO., INC. MODEL # XX YEAR WARRANTY INSTRUCTION MANUAL

MINI MCR-SL-UI-UI(-SP)(-NC)

INSTRUCTION MANUAL. Air Curtains Rund (M, G)

World Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants

ECON D4 sauna control unit

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

essentia audiotoo s User Manual Rev 2.0 September 2015 Mains Multiplier 5 Mains Multiplier 7 Mains Multiplier 8

ARTICLE BEGINNING SERVICE PRECAUTIONS

VERTICAL MULTISTAGE PUMP SETS

TRANSPONDER TERMINAL MANUAL. Version: July 2012

Instructions for the BASIC BCVA Rotary heat exchanger, Sizes

Operating manual UPS - System

DRAFT COPY, NOT FOR DISTRIBUTION

WARNING This manual should only be used by a qualified Service Technician. FinishPro 390/395 Airless/Air-Assisted Sprayer Repair Electrical Manual

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Inverter User Manual

TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22

PARTS & SERVICE MANUAL

SYSDrive Frequency Inverter

V 2.0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W. Instruction Manual

1900 William Street. Racine, WI (262) Transformer Application Notes

24 Hour Mechanical Time Switch with Voltage Free Contacts

Concealed Ducted Split Series R22

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Example of Combining Different Types of Heater Control. Heater control. Temperature Controller

Before installation please observe the following points: After installation, please observe the following points:

PSM72H Push-Button Start Module

Northwest RV Supply Manual Compliments of Printed From TROUBLESHOOTING

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

BID SPECIFICATIONS 2018 TERMINAL BUILDING STANDBY GENERATOR PROJECT

User Manual. Solar Charge Controller 3KW

Goedhart FC38. Standard air coolers Cu/Al. R404A - Coolants. engineering for a better world. GEA Heat Exchangers. Goedhart FC38S.

Pro-Series/ Electromechanical Linear Actuator

QS20.241, QS C1

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

P445 Series Electronic Lube Oil Control

Temperature Controller. TC5+2V4SA Plus USER'S MANUAL

Light Source User Guide

MPPT5012A-DUO-BT MPPT5025A-DUO-BT

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

Operation of the FFBH is enabled and disabled by the Automatic Temperature Control Module (ATCM).

OPERATING INSTRUCTIONS

A6C A5C-B6C B5C B5H A6C A5C B6C B5C B5H. Model. Up to kw. Power. Up to V. Voltages. Model IP55. Frame Pole 2, 4, 6, 8 and 10

Remote Temperature Controller for Heated Mold Shoes, using a RTD/Digital Display, # C (version pre-2009).

Diesel Cooker X 100. Installation Instructions

COMFORT AIR CURTAIN. SensAir

Service Manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta

Application Mini Contactors for Motors and Resistive Loads

Technical Manual Electrical Power Supply System T4002

Installation Instructions

Operating instructions EWB 200

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

Table of Contents. ENGLISH Contents Page

PROCESS ELECTRONICS CORPORATION

PURE SINE WAVE DC TO AC POWER INVERTER

DEVICE STATE/BYPASSED FAILURE OVERLOAD

PANTHER MAXI AC / MINI

,IWKHUHDUHDQ\TXHVWLRQVFRQWDFW6WHIIHV&RUSRUDWLRQ 7HFKQLFDO6XSSRUWDW67())(6

80W. Operating Manual. Dual Power. Intelligent Balance Charger LiPo/LiFe/LiIon: NiMH/NiCd: Pb: Charge Power: Charge Rate: Discharge Rate:

Installation and operating instructions. Solar charge controller 10 A / 15 A / 0 A / 30 A PHOTOVOLTAIK - PHOTOVOLTAICS - PHOTOVOLTAIQUE - FOTOVOLTAICA

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

HE1U 1248 BMS High Efficiency 1U AC to DC Power Supply Owners Guide SPECIFICATIONS

RVS-AX Instruction Manual

Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors

Owner s Guide. DC TO AC Power Inverter

INTRODUCTION. Specifications. Operating voltage range:

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

MINI MCR-SL-UI-UI(-SP)

Class X Chapter 09 Electrical Power and Household circuits Physics

MANUAL D250SA SMARTPASS 120. Input Solar panel Earth Connection

AIR COOLED RECTIFIER SPECIFICATION S-50-A

AKF10+ Application. Types Available. Duct-/Immersion temperature sensor. Datasheet

UV- TECHNOLOGY. Technical Documentation ELC N6 / ELC N8 / ELC N10

D10 Page. Contents. Complete Equipment with Scope of Supplies 2. Accessories 3

SMI SERIES MOTORS WITH INTEGRATED INVERTER

Transcription:

Installation- and Operating Instructions SAUA exclusiv 9kW Sauna control 400V Art.r. 3112600003 Function: The electronic control unit Sauna-exclusiv consists of a power component and of a flat control panel intended for surface mounting. In the power component there are all connections for the power supply connections, the sauna heater, the ventilator, the cabin lighting, the sensor and for the control panel. The power component controls the temperature in the sauna cabin within the range of 70 C to 110 C. For safety reasons the maximum temperature in the cabin is limited to 139 C by an additional temperature fuse. The built-in counter timer enables an automatical switching on of the heating to an adjustable point of time for a heating period of max. 6 hours. The heater, the cabin lighting and the ventilator may be switched on- and off on the control panel. The temperature selection as well as the setting of the counter timer are also operated on the control panel. Any operational information is displayed on the display of the control panel. Technical Specification: Dimensions: Power component: 220x218x108mm³ Operating voltage: Control power draw: Breaking capacity: Control range: Control unit: 194x157x23mm³ 3 AC 400V ca. 6VA 9kW (AC1) 70-110 C Temperature limit: 139 C Protection type: Ambient temperature: Fitting: According to their protection type both the control unit and the operating unit are to be fitted outside the sauna cabin to be protected against damp. The operating panel must be fixed near the sauna cabin door. According to the accompanying drawing the temperature sensor should be side-mounted to the heater near the cabin ceiling. The side clearance to the middle of the heater should be around 500mm. The clearance to the ceiling should not exceed 200mm. You should avoid placing the sensor near the exhaust opening or the door as well as near the cabin corner. IP 44 (splash-proof) 0-40 C

Operating Instructions Sauna exclusiv 9kW Page: 2 The power supply of the device has to be carried out by an universal-pole main switch having a contact opening width of at least 3mm. Before opening the casing it is absolutely necessary to discharge the device from voltage. Electric connection: The electric connection as well as all adjusting and service operations may only be carried out by an approved electrical expert! The enclosed connection plans and the current safety regulations in force are to be followed. L1 L2 L3 U1 V1 W1 U2 U3 5 6 7 8 16A mains 3 AC 400V sauna heater 3x230V/max. 9kW Sauna exclusiv 9kW M fan light control panel red - temperature fuse white - temperature sensor Should only one monopolar 230V mains supply be available, then the mains supply is to be carried out according to the following connection diagram: L1 L2 L3 U1 V1 W1 U2 U3 5 6 7 8 16A mains 1 AC 230V sauna heater 3x230V max. 9kW Sauna exclusiv 9kW M fan light control panel red - temperature fuse white - temperature sensor To ensure a smooth distribution of the load among the three switching contacts in the control device, the U1, V1 and W1 connector must not be bridged in the control device. The outer conductors are to lead separately to the heating coils. Please note that with a monopolar feeding the zero conductor of the heating will carry the treble amount of current of the outer conductors. This current must not be fed to the circuit board via the clamps. The zero conductor of the heating has to be externally connected to the zero conductor of the circuit feeding! The electronic control is fused on the circuit board by a 0.16A fine fuse. In the control device the connected consumers are not protected against short-circuit. The short-circuit protection has to be ensured by suitable constructional fuses (max. 16A). The power component is connected with the control panel by a four-conductor telephone line (osf-art.r. 3100000500). The maximum length of the line is 30m. Lines within the sauna cabin are to be heat resistantly equipped.

Operating Instructions Sauna exclusiv 9kW Page: 3 Operational controls on the control panel: LCD-display O/OFF button Counter Timer button Ventilator button Temperature selection Adjusting buttons Setting time Setting switch timer Cabin lighting button LCD-Display 16:10 If the control is switched off, then only the current time is displayed. 16:10 If the power supply has been interrupted, this is indicated on the Power failure display. The display will disappear on pressing any button. Start in: 82,3 C 16:45 Sauna time 2:35h 16:10 The counter timer has been activated. Referring to the current time 22:35h the remaining time up to finally switching on the equipment is displayed. The sauna control is in operation. Time, temperature in the cabin and the remaining operational time are displayed. 18:32 The temperature sensor in the sauna cabin is defect or the line to the Sensor defect temperature sensor has been interrupted or short-circuited. After the error has been handled this message may be deleted by pressing any button. Temp. 144,8 C fuse 12:55 98,3 C 21:03 Unit overheated O/OFF button The temperature in the sauna cabin has exceeded 139 C. This could have triggered the temperature safety fuse in the sensor casing. After the cabin has been cooled down this message may be deleted by pressing any button. The temperature in the power component casing is too high. After cooling down the control, this message may be deleted by pressing any button. By using the button the sauna may manually be switched on and off. Attention! By this the control is not discharged with tension! If the sauna is switched on this button is on.

Operating Instructions Sauna exclusiv 9kW Page: 4 Activating counter timer Switching on ventilator By using the button the counter timer can be activated after a prior programming of the switching time and the operating time (see below). This counter timer switches on the sauna at the programmed time. If the counter timer has been activated, this button is on. By using the button the ventilator in the sauna cabin can be switched on. If the ventilator is switched on, this button is on. Switching on cabin lighting By using the button the lighting in the sauna cabin may be switched on. If the lighting is switched on, this button is on. Selecting temperature With the Press the button the temperature in the sauna cabin can be selected. 78,5 C <---- button the display will indicate Saunatemperature 1. With the and buttons you can now adjust the desired temperature within a range of 70 C to 110 C. 2. To store the desired temperature, please press the button again. If you do not press any button for more than 10 seconds during the temperature setting, the last selected temperature is automatically stored and the normal operating display will appear again. Setting time With the button the current time is set. 1. Press the button the display will indicate. Time 14:44 2. ow the time can be set by pressing the and buttons 3. To store the time please press the button again. If you do not press any button for more than 10 seconds during the setting process, then the last displayed time is automatically stored and the normal operating display will appear again.

Operating Instructions Sauna exclusiv 9kW Page: 5 Setting counter timer The button serves the programming of the built-in counter timer. 10:25 1. Press the button the display will indicate Start time. 2. By pressing the and buttons the desired turn-on time may be set. 6:00 3. Press the again the display will indicate Operation period 4. By pressing the and buttons the desired operation period may now be set. The counter timer can only be activated (see above) after programming an operation period. To store the switching times, press the button again. If you do not press any button for more than 10 seconds during the setting process, then the last displayed switching time is automatically stored and the normal operating display will appear again. Check list for probable malfunctions: Any system components are factory-checked for their functions. Should any disturbances occur even though, the following items should be checked, provided the proper installation in any case, and whereas the connecting lines soundly operated- need to be fixed properly in the supply terminals. 1.) Does the line voltage fit tightly between the supply terminals L1, L2, L3 and? 2.) Has the temperature sensing system been fitted according to the fitting instructions? 3.) In case of a malfunction of the control panel: Keep the control at the constructional main switch without voltage and check the fine-wire fuse for the Control Control panel control electronic and the control panel. These are situated inside the power component on the circuit board. 4.) If the heating does not work: 4.1. In case of overheating the sauna cabin the thermal electric fuse which is situated in the sensor casing in the cabin, will switch off the heating. After cooling down it is not automatically switched on and the sensing system has to be changed. Checking the temperature fuses: Disconnect from the clamps 5 and 6 located at the power component, both cable conductors of the red line. Measure the temperature fuse by using either a resistance meter or a circuit continuity tester. A defect temperature fuse does not show any conduction. 4.2. For safety reasons the heating is automatically switched off in the following cases: the temperature sensor is defect, there has been an interruption or the sensing line 18:32 Sensor defect

Operating Instructions Sauna exclusiv 9kW Page: 6 shows a short-circuit. Checking the temperature sensor: Disconnect both cable conductors of the white line from the clamps 7 and 8 located at the the control device. Measure the temperature sensor with a resistance meter. At room temperature an intact temperature sensor shows an electric restistance of approx. 68kOhm (see accompanying coordinate). 5.) Should the set temperature not be reached with a properly working temperature control: 5.1. The temperature sensing system has to be installed according to fitting instructions. Should the sensor have been placed in the warm air flow above the heater, it needs to be moved sideways as far as the rising warm air cannot cause an early switching off of the heater. 5.2. Should the sauna heater be switched off with soundly installed sensing system, this problem is then to be solved by adjusting the temperature range. For this a trimming potentiometer has been placed on the circuit board (see sketch). Sensor alignment We wish you a lot of pleasure and relaxation in your sauna. Subject to alteration! March 07