From the dawn of Excellence emanates the high noon of Performance.

Similar documents
From the dawn of Excellence emanates the high noon of Performance.

Series Motor Protection

Micro Controller based Motor Protection Relay & Motor Management System

Metering Products Protection Units Current Transformers. April 1, 2015

KD LV Motor Protection Relay

Metering Products. Metering Products Protection Units April 1, Price List. Price List. With effect from April 1,

Ambilin Incorporate.

M440 MOTOR PROTECTION, EARTH FAULT LOCKOUT & MANAGEMENT RELAY VERSION 3.5 NINGI SERVICES (PTY) LTD

Starters. Overview. Siemens caters with following types of starters to agricultural and industrial sector.

LA Motor Protection. A South African Company to be Proud of

Part # Features & Applications Specifications Cross Reference

ICG Switchgear Price List 2009

DIP SWITCH BASED EARTH LEAKAGE RELAY (ELR) WITH CORE BALANCE CURRENT TRANSFORMER (CBCT / ZCT) EL SERIES

Rotomatik Corporation

Franklin Electric Submersible Motors SUBMERSIBLE MOTORS. Motors Accessories. Product Information and Service

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

MCD Pump Application Module

TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID

TOTALINE PROTECTION CONTROLS

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

Bulletin 825 SMM Smart Motor Manager

ELECTRICAL SYSTEM RP-7

Defining a timer in simple terms. Which actions are executed? Which market are they used frequently? Benefits and Advantages

SALES PRESENTATION FOR RELAYS, CONTACTORS & MOTOR STARTER TESTING EQUIPMENTS

PHASE PERFECT PHASE CONVERTERS OPERATION & INSTALLATION MANUAL PHASE TECHNOLOGIES, LLC

Designed for ease of integration with automation systems

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

GCU-10. Automatic Engine Control Unit Operators Manual

Hydrovar and Packaged Hydrovar

Quality Products, Prompt Service, Trustful Relationships.

Variable Speed Product Line

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

Designed for Today s World

Designed for Today s World

BRSDRIVE ITT. Goulds Pumps. S-Drive. Simplex Variable Speed Submersible Pump Controller. Engineered for life

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

B BASIC HEAT TREATMENT CONSOLE

Open Chassis Star-Delta Starter User Guide

SDM72 Start on Demand Modules

power made simple kva RANGE Performance I Durability I Serviceability

HOTLINE ELECTRICAL TRADING

Inverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B

MINIATURE CIRCUIT BREAKER

TECHNOLOGICALLY ADVANCED ENERGY PRODUCTS. Product Preview & Price List 2018

NOCCHI FREQUENCY CHANGER PRESSURE BOOSTERS WITH VARIABLE SPEED

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Application Engineering

Product selection table

Selection Guide Motor Control Device Solutions

EPS-ECONOMY PUMP STARTER

SDS Enclosed Star-Delta Starter User Guide

CONSTANT PRESSURE CONTROLLERS

Designed for Today s World

Welcome to Corporate Presentation

REVISED ATM72 Auto Transfer Module

SECTION MOTOR CONTROL

CG PRESSURE BOOSTING SYSTEMS

Application Engineering

Meta Solution. Contactors and Overload relays

CI-TI Contactors and Motor Starters Type CI 6-50

MODEL 422 Submersible Pump Controller

Electronic timers CT-S range Function diagrams

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

amp ramp Operators Manual Page 1 Saftronics 2S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD1 6QT

Contactors and Overloads MC

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY

CP Automatic capacitor bank

UNIVERSAL PRODUCT RANGE. Performance I Durability I Serviceability

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

TDX - Taco Duplex Starter with

Module 2 CONTROL SYSTEM COMPONENTS. Lecture - 4 RELAYS

2 SLR Series Line Reactors... 50

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Protection and control. Self-reclosing overload and earth leakage protection

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

SD Series Non-Fused Load Switches

Submittal Data Information

ADS7 AC Contactor Starters

Moulded Case Circuit Breakers

CTi Automation - Phone: Fax: Web:

Industrial Chargers and

Legat-65. Voltage Stabilizer Technical Certificate. NOVATEK-ELECTRO LTD Research-and-Manufacture Company

S H A D E S ELECTRICAL DB MANUFATURING

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

VLT Soft Starter. Remote operation. Serial communication 24 V AC/DC V AC. Constant effort to improve MCD 100, MCD 201, MCD 202, MCD 3000

DIGITAL EARTH LEAKAGE RELAY

32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide

VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000

Softstarters Type PSS. Softstarters. General information

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

ABB Softstarter Benefits Charnchanok Thongprad

Table of Contents. For latest version, visit:

Motor Protection Circuit Breaker

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

70 kw GENERAC STANDBY GENERATORS. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES: Standby Power Rating Model QT070 (Bisque) - 70 kw 60Hz

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

Cat/DCG-6D1I/07-08/03/Ver 1 Page 2/10

PD-Series Ground Fault Circuit Protection

Transcription:

From the dawn of Excellence emanates the high noon of Performance.

Gelco Electronics is a full service electronic company that manufactures superior quality electronic control and switchgear products & measuring equipment alongwith power saving devices. Established in 1984, the company is located in the industrial belt of Ahmedabad, which is one of the fastest developing metropolitan cities of India. Our state of the art manufacturing facility with its prolific R&D centre in conjunction with our strict adherence to quality control and safety norms has ensured an impressive growth record in these past three decades. More importantly, it has gained a reputation of excellence & dependability from its clients. After achieving wide success in the Indian market, Gelco is now spreading its wings internationally. To attain the same level of success globally, Gelco has conducted extensive research in each market to understand their electrical equipment s needs and subsequently, developed specific products for them that are longlasting, efficient and safe. R a n g e of P r o d u c t s Single Phase Motor Starters & Control Panel Three Phase DOL Motor Starters & Control Panel Three Phase Star Delta Motor Starters & Control Panel Duty Stand by Panel for Dual Pumps Panel Accessories A p p l i c at i o n s Home Agriculture Industries

SINGLE PHASE MOTOR STARTER Input Supply voltage : 230V, AC ±20% Output supply voltage : 230V, AC ±20% INDEX Topic Page Single Phase Motor Starter 1-2 Single Phase Electronic Control Panel 3 Three Phase Dol Motor Starter 4-5 Three Phase Dol Motor Starter - Metal Body 6 Three Phase Star Delta Motor Starter 7 Three Phase Dol Electronic Control Panel 8 Three Phase Star Delta Electronic Control Panel 9 Duty Stand By Panel For Dual Pumps Operation 10 Voltage Stabilizer 11 Auto Switch 12 Single Phase Starter 13 A.C. Switch 14 Phase Failure Relay 15-16 Motor Protection Relay 17 Pump Protection Relay 18 Analog Timer 19-20 Digital Timer 21 Digital Time Switch 22 Earth Leakage Relay 23-24 Earth Leakage Circuit Breaker 25 Panel Meters 26 Automatic Light Controller 27 Single Phasing Preventer With Water Level Guard 28 Water Level Controller 29-30 (1.1) GSS-MCB Easy to operate Overload protection through MCB Economical solution Enclosure made from engineering grade plastic (ABS) Only for Oil Filled Pump set Motor H.P. Run Capacitor MCB 0.75 HP 0 + 25 MFD 10 Amp. 1.0 HP 0 + 36 MFD 10 Amp. 2.0 HP 0 + 50 MFD 16 Amp. 3.0 HP 0 + 72 MFD 25 Amp. (1.2) GSS-RE Electronic start/stop push buttons. Electronic overload protection High voltage protection above 280 V AC. Low voltage protection below 150 V AC.. Facility to connect Gelco Water Level Controller Adaptor NOTE: A wide range of products which can be offered on request. We can supply starter / panel / A.T.S. panel / 60 Hz starter / panel as per customer s specifications. A wide range of lighting products which can be offered on request. We can supply submersible flat & round, PVC & rubber, 3 core and 4 core cable. We can supply submersible pumpsets, monoblock pumpsets, industrial pumpset, electric induction motors & UPVC column pipes etc. Due to continues R & D; specifications, construction of materials, design, out look, colour & finishing etc. can be changed without intimation. ( LLC-001D) Only for Oil Filled Pump set Motor H.P. Run Capacitor Current Range 0.75 HP 0 + 25 MFD 4-10 Amp. 1.0 HP 0 + 36 MFD 4-10 Amp. 2.0 HP 0 + 50 MFD 10-16 Amp. 3.0 HP 0 + 72 MFD 10-16 Amp. 1

SINGLE PHASE MOTOR STARTER Input Supply voltage : 230V, AC ±20% Output supply voltage : 230V, AC ±20% SINGLE PHASE ELECTRONIC CONTROL PANEL Input Supply voltage : 230V, AC ±20% Output supply voltage : 230V, AC ±20% (1.3) DCP - RE Electronic start/stop push button. Inbuilt digital volt and amp meter Latest Micro Controller Based Technology for better accuracy Precise protection against over load (over current) Precise protection against high voltage Precise protection against low voltage Dry run protection (optional) Digital indication of fault condition. Engineering grade plastic enclosure( ABS) Facility to connect GELCO Water Level Controller Adaptor ( LLC-001D) With programmable parameters Only for Oil filled pumpset Motor H.P. Run Capacitor Current Range 1.0 HP 36 MFD 2-16 Amp. 1.5 HP 50 MFD 2-16 Amp. 2.0 HP 72 MFD 2-16 Amp. (2.1) MCB WS In built digital volt and amp. meter ( GELCO ACCURA) Easy to operate Powder coated sheet metal enclosure. Submersible/monoblock Pump set. MCB Start Capacitor Run Capacitor 10 100/120 MFD 36 MFD 20 150/200 MFD 36 + 36 MFD 25 200/250 MFD 36 + 36 MFD 25 200/250 MFD 50 + 50 MFD (2.2) DCP - 7201 Fully automatic electronic start/stop facility Digital Micro Controller Based Technology Higher accuracy Digital indication of fault condition. Precise overload protection (over current) Precise overvoltage protection Precise under voltage protection Dry run protection. With programmable parameters In built auto ON/OFF timer ( 1-240 Minutes) Powder coated sheet metal enclosure. Submersible/Monoblock Pumpset for drawing water in residence, commercial, farming, gardening. Motor H.P. Start Capacitor Run Capacitor Current Range 1.0 HP 100/120 MFD 36 MFD 4-20 Amp 1.5 HP 150/200 MFD 36 + 36 MFD 4-20 Amp 2.0 HP 200/250 MFD 50 + 50 MFD 15-30 Amp 2 3

THREE PHASE DOL MOTOR STARTER Input/Output Voltage : 415V, AC ±20%, 50Hz. (3.1) GTW Current sensing unit Inverse time current characteristics Electronic start/stop push button facility Electronic overload protection. Dry run protection (optional). Reverse phasing protection Can be used up to 7.5Hp DOL motor/pumps Other Models are also available on request D.O.L. submersible pump set for drawing water in residence, commercial, farming, gardening. Induction motor in industries (3.3) GTA All facilities available as per GTV Additional facility to put the Motor/Pump ON automatically after power supply resumption. One minute time delay before start Can be used up to 7.5Hp DOL motor/pumps D.O.L. submersible pump set for drawing water in residence, commercial, farming, gardening. Induction motor in industries Type GTA-304 GTA-305 GTA-306 Current Range 2-5 Amp. 4-10 Amp. 8-20 Amp. Type GTW-304 GTW-305 GTW-306 (3.2) GTV Current Range 2-5 Amp. 4-10 Amp. 8-20 Amp. All facilities available as per GTW Current and voltage sensing unit Low/High cut out Facility to connect GELCO Water Level Controller (Model LLC-001/LLC-001D) Can be used up to 7.5Hp DOL motor/pumps D.O.L. submersible pump set for drawing water in residence, commercial, farming, gardening. Induction motor in industries Type GTV-304 GTV-305 GTV-306 Current Range 2-5 Amp. 4-10 Amp. 8-20 Amp. (3.4) DCP - 304 Using latest Micro controller based technolgy Electronic Start/Stop push button Inbuilt digital volt & amp Meter Digital display of fault condition Electronic overload protection Dry Run protection With programmable parameters Reverse phasing protection Facility to connect GELCO Water Level Controller Adaptor ( LLC-001D) Engineering grade plastic enclosure(abs) Can be used up to 7.5Hp DOL motor/pumps Three phase DOL submersible/monoblock pump set for drawing water in residence, commercial, farming, gardening Current Range 2-20 Amp. 4 5

THREE PHASE DOL MOTOR STARTER - METAL BODY Input Voltage : 415 V ± 20% VAC Output Voltage: 415 V ± 20% VAC THREE PHASE STAR DELTA MOTOR STARTER Input Voltage : 415 V ± 20% VAC Output Voltage: 415 V ± 20% VAC (4.1) GEW-1(DOL) (5.1) GLO-FASD / SA-Metal Body Easy to operate Powder coated sheet metal enclosure Thermal overload protection D.O.L Motors for drawing water in residence, commercial, farming, gardening. Motor H.P. Overload Range 5.0 HP 6 10 A 7.5 H.P 9 14 A 10 H.P 13 21 A Type Motor H.P. Overload Range GLO-1 3 HP 6-10 A GLO-1 4 HP 6-10 A GLO-1 5 HP 6-10 A GLO-1 6 HP 6-10 A GLO-1 7.5 HP 6-10 A GLO-1 10 HP 6-10 A GLO-1 12 HP 10-16 A GLO-1.5 15 HP 13-21 A GLO-2 20 HP 20-32 A GLO-2 25 HP 20-32 A GLO-3 30 HP 28-42 A GLO-3 40 HP 28-32 A (4.2) GLO-1 (DOL) Motor H.P. Overload Range 3.0 HP 6 10 A 5 H.P 6 10 A 7.5 H.P 10-16 A (4.3) GLO-1.5 / 2 / 3 (DOL) Motor H.P. Overload Range 10 HP 13-21 A 15 H.P 20-32 A 20 H.P 20-32 A 30 H.P 28-42 A 6 7

THREE PHASE DOL ELECTRONIC CONTROL PANEL Input Voltage : 415 V ± 20% VAC Output Voltage: 415 V ± 20% VAC THREE PHASE STAR DELTA ELECTRONIC CONTROL PANEL Input Voltage : 415 V ± 20% VAC Output Voltage: 415 V ± 20% VAC (6.1) DIGI : DOL Inbuilt digital volt & amp meter ( AVM-101) With bright LED phase indication with flash Automatic rotational phase to phase voltage indication Thermal overload protection Short circuit protection through MCB Auto start after resumption of supply Powder coated sheet metal encloser For 3 phase DOL Submersible/Monoblock Pump set for irrigating remote farms, unreachable/vast gardening area. Relay Range 4-6.5 Amp. 6-10 Amp. 9-14 Amp. 13-21 Amp. (6.2) DCP-9603 Using latest micro controller based technolgy Electronic start/stop push button Inbuilt digital volt & amp Meter Digital display of fault condition Electronic overload protection Dry run protection With programmable parameters Reverse phasing protection Inbuilt auto ON/OFF timer Facility to connect GELCO Water Level Controller Adaptor ( LLC-001D) Remote ON/OFF Powder coated sheet metal enclosure (IP-55) Digital display facility on faulty connection Three phase DOL Submersible/Monoblock pump set for drawing water in residence, commercial, farming, gardening. Current Range 2-5 Amp. 4-10 Amp. 8-20 Amp. (7.1) DCP-9613 Fully automatic star delta starter Using latest micro controller based technology Inbuilt digital volt /amp meter Electronic overload protection Dry run protection Current sensing unit Reverse phase protection With programmable parameters Inbuilt auto ON/OFF timer Powder coated sheet metal enclosure (IP55) Easy to maintain detachable spares Remote ON/OFF Facility to connect GELCO Water Level Controller Adaptor ( LLC-001D) Digital display facility on faulty connection For three phase star delta motors used in farms, pumping station, municipal corporation Motor H.P. Overload Range Motor H.P. Overload Range 7.5 HP 8-20 Amp. 20.0 HP 16-40 Amp. 10.0 HP 8-20 Amp. 25.0 HP 24-60 Amp. 12.5 HP 16-40 Amp. 30.0 HP 24-60 Amp. 15.0 HP 16-40 Amp. 35.0 HP 32-80 Amp. 8 9

DUTY STANDBY PANEL FOR DUAL PUMPS OPERATION VOLTAGE STABILIZER (8.1) DUTY STAND BY PANEL FOR DUAL PUMPS OPERATION Volt current and other fault conditions display. Over voltage, under voltage and dry run protection. Pump run and trip indication. Singe phasing, current and voltage sensing protection. Selector/toggle switch for pump-1 and pump-2 or alternate operation Manual/auto ON/OFF Sheet metal enclosure with IP-55 protection Suitable for booster pumps application Up to 35 HP - DOL or FASD (9.1) SERVO S e r v o C o n t r o l l e d Vo lta g e Sta b i l i z e r I/P: 170V to 270V (For 1 Phase) 360V to 460V (For 3 Phase) O/P: 230V AC + 1% for 1 Phase 415V AC + 1% for 3 Phase Also available in customised I/P and O/P voltage range Capacity: Up to 400 KVA Cooling: air cooled oil cooled Balance or unbalance type, Display parameter: digital volt and amp. meter Protection: over voltage, under voltage, overload & single phasing (9.2) VIOLTEÉ Model GDMS-20 Input Range 170V AC 270V AC Output Range 220V AC ± 10% Time Delay 5 Sec. Application Television/ DTH GDMS-50 170V AC 270V AC 220V AC ± 10% 3 Min. Refrigerator DLC-50 170V AC 270V AC 210V AC 230V AC 10 Sec. Computer (9.3) VIOLTEÉ emax Model Input Range Output Range Time Delay GDMS - 300 GDMS - 400 GDMS - 500 170V AC 270V AC 170V AC 270V AC 170V AC 270V AC 220V AC ± 10% 220V AC ± 10% 220V AC ± 10% 3 Min. 3 Min. 3 Min. 10 11

AUTO SWITCH SINGLE PHASE STARTER Input Voltage : 230 V, AC ± 10% Output Voltage: 230 V, AC ± 10% (10.1) Auto Switch Voltage sensing unit Reverse phasing protection Auto ON after resumption of power supply Panel mountable Aux supply voltage: 415V AC +/- 20 %, 50 Hz Phase unbalance volt: 45 V +/- 5 V Start time delay: 1 Minute Output: 1 C/O, 6 Amp (Resi.)@ 230 VAC For MCC panels of water pump at remote farms, unattaindable area. (10.2.1) GSW I/P: 230 V, 1phase, AC supply ABS body High/Low voltage protection Over load protection Variable current (Amp.) setting Type GSW-104 GSW-105 GSW-106 GSW-107 GSW-108 Current Range: 2-5 Amp. 4-10 Amp. 8-14 Amp. 10-16 Amp. 14-22 Amp. (10.2.2) GSW-T I/P: 230 V, 1phase, AC supply, ABS body High/Low voltage protection Over load protection Time delay facility Variable current /Amp setting Auto/manual start facility Type GSW-T-104 GSW-T-105 GSW-T-106 GSW-T-107 GSW-T-108 Current Range: 2-5 Amp. 4-10 Amp. 8-14 Amp. 10-16 Amp. 14-22 Amp. 12 13

A.C. SWITCH PHASE FAILURE RELAY ((10.2.2) AaCcSVCH Input voltage: 85V Ac To 300V Ac Current range: 2A to 16A High voltage protection : Above 280v High voltage cut in: Below 260v Low voltage protection : Below 160v Low voltage cut in : Above 175v Over load protection programmable range 2A to 16A (auto/manual) Time delay : 60 sec.(1minute) After resumption of power supply Switching device : Relay Display of live voltage and live current by seven segment LED Display total run time of your load in hour Air-conditioner, television, refrigerator, domestic flour mill (10.3.1) PFR-104 Slim in size Higher accuracy Voltage sensing unit Reverse phasing protection DIN rail mountable Aux supply voltage: 415V AC +/- 20 %, 50 Hz Phase unbalance volt: 45 V +/- 5 V Tripping delay: 4 to 7 sec Output: 1 C/O, 6 Amp (Resi.) For MCC panels of water pumps, generators, compressors (10.3.2) PFR-105 Slim in size Higher accuracy Voltage sensing unit DIN rail mountable Aux supply voltage: 415 VAC +/- 20 %, 50 Hz Phase unbalance volt: 45 V +/- 5 V Tripping delay: 4 to 7 sec Output: 1 C/O, 6 Amp (Resi.) For MCC panels of water pumps, generators,compressors 14 15

PHASE FAILURE RELAY MOTOR PROTECTION RELAY (10.3.3) PFR-106 Slim in size Higher accuracy Voltage sensing unit Reverse phasing protection DIN rail mountable Aux supply voltage: 415V AC +/- 20 %, 50 Hz Phase unbalance volt: 45V +/- 5 V Over voltage: above 480 VAC Under voltage: below 320 V Tripping delay: 4 to 7 sec Output: 1 C/O, 6 Amp (Resi.) For MCC panels of water pumps, generators, compressors, lift (10.4.1) MGR-101 Current sensing unit Inverse time current characteristics - 2 sec. Reverse phase protection Electronic over load protection Low/High voltage protection DIN rail & panel mountable Aux. supply voltage 415 +/- 20 % VAC Over voltage: 120% +/- 5 V of supply voltage Under voltage : 80 % +/- 5 V of supply voltage Current unbalance phase-phase: 50 % of full scale current Tripping delay: 4 to 7 Sec. MCC panels of water pump. R e l ay R a n g e: CT Unit CTU-05 CTU-10 CTU-20 CTU-40 CTU-80 Current Range (Amp) 2-5 A 4-10 A 8-20 A 16-40 A 32-80 A (10.4.2) MGR-102 Current & voltage sensing unit Inverse time current characteristics - 2 sec. Electronic over load protection Reverse phase protection DIN rail & panel mountable Aux. supply voltage 415 +/- 20 % VAC Over voltage: 120% +/- 5 V of supply voltage Under voltage : 80 % +/- 5 V of supply voltage Current unbalance phase-phase: 50 % of full scale current Voltage unbalance phase-phase : 45 +/- 5 V Tripping delay: 4 to 7 Sec. MCC panels of water pump. R e l ay R a n g e: CT Unit CTU-05 CTU-10 CTU-20 CTU-40 CTU-80 Current Range (Amp) 2-5 A 4-10 A 8-20 A 16-40 A 32-80 A 16 17

PUMP PROTECTION RELAY ANALOG TIMER (10.5.1) PGR-101 Current sensing unit Inverse time current characteristic - 2 sec. Electronic over load protection Reverse phase protection Dry run protection ( prodless ) Aux. supply voltage 415 +/- 20 % VAC Over voltage: 120% +/- 5 V of supply voltage Under voltage : 80 % +/- 5 V of supply voltage Current unbalance phase-phase: 50 % of full scale current Dry run : 40 % to 80 % of overload setting Tripping delay: 4 to 7 Sec. Output 1 c/o, 6Amp. (Resi) at 230VAC MCC panels of water pump in hilly regions R e l ay R a n g e: CT Unit CTU-05 CTU-10 CTU-20 CTU-40 CTU-80 Current Range (Amp) 2-5 A 4-10 A 8-20 A 16-40 A 32-80 A (10.5.2) PGR-102 Current & voltage sensing unit Inverse time current characteristics - 2 sec. Electronic over load protection Reverse phase protection DIN rail & panel mountable As per PGR-101 Voltage unbalance phase to phase : 45+ 5V MCC panels of water pump R e l ay R a n g e: CT Unit CTU-05 CTU-10 CTU-20 CTU-40 CTU-80 Current Range (Amp) 2-5 A 4-10 A 8-20 A 16-40 A 32-80 A (10.6.1) AC-22 Cyclic timer Easy to programme, through dial on front DIN rail mountable Engineering grade plastic enclosure(abs) Supply: 110/230V AC ± 20% 50 Hz, 12/24V AC/DC Output: 2 C/O relay (5A @ 230 VAC) Control action: cyclic Time range: 1-10 sec /min/hr. selectable through DIP switch Reset: power on reset MCC panels for water pump, compressor, generator, airconditioner (10.6.2) AS-22 Single action timer Delay ON/ OFF timer (Selectable ) Easy to programme with the help of dial in front DIN rail mountable Supply: 110/230V AC ± 20% 50 Hz, 12/24V AC/DC Output: 2 C/O Relay (5A @ 230 VAC) Control action: selectable delay ON/OFF Time range: 1/3/10/30 sec/min/hr. selectable through DIP Switch Reset: power on reset MCC panels for water pump, compressor, generator 18 19

ANALOG TIMER DIGITAL TIMER (10.6.3) AS-21 Single action timer Delay ON/OFF timer (factory set) Higher accuracy Easy to programme with the help of dial in front DIN rail mountable Engineering grade plastic enclosure(abs) Supply: 230/415V AC ± 20% 50 Hz Output: 1 C/O relay (5A @ 230 VAC) Control Action: delay ON/ delay OFF Time range: 0-60 sec Reset: power on reset MCC panels for water pump, compressor, generator, airconditioner (10.6.4) SD-22 Star delta timer DIN rail mountable Higher accuracy Easy to programme Engineering grade plastic encloser (ABS) Supply: 110/230/415V AC ± 20% 50 Hz Output: 2 No. 1 C/O (230V AC, 6A) Time range: y run up time 30/60 sec y to Δ change over time 30-100m sec Reset: power on reset MCC panels for Star Delta pump set. (10.6.1) DT-48 Supply: 85V-265V AC, 50 Hz Output: 2 C/O relay (5A @ 230 VAC) Control action: selectable Delay On/Off & Cyclic Time range: 0-99.9 hr./min./sec. Display: 0.4 seven segment LED Accuracy: ± 0.01% of FSD (10.6.2) DT-21 Supply voltage: 85V AC-265V AC, 50 Hz Output: relay NO-C-NC Relay contact rating: 5A/230V AC resistive Modes: Delay on, delay off Cyclic C1: (relay ON@ power ON) Cyclic C2: (relay OFF @power ON) Display: 2 digit 0.39 (7 segment LED) Accuracy: 0.01% of set time ± 1 display Processing industries (10.6.3) DOT - 101 Delayed off timer Compact size Body made from black colour, industrial plastic materials (ABS) Easily programmable Simple installation Input supply: 230V AC, 50 Hz, 1Ø Output: 230V AC, 50 Hz, 1Ø Output capacity: 6A, 230V (Resi.) Time range: 5 to 40 min. (instep of 5 min/step) Exhaust fan Any application where delayed off time is required 20 21

DIGITAL TIME SWITCH EARTH LEAKAGE RELAY (10.7.1) DTS-502 On/ Off time is programmable 10 No of programme for On/Off Display of real time clock LED display for unit On Easy to programme Input supply : 230 +/- 20 % VAC Output supply : 230 +/- 20 % VAC Capacity : 20 Amp at 230 VAC (Resi.) Water pump, street lights (10.7.2) DTS-601 (10.8.1) ELR-101 High precision Surface mountable (DIN Standard) Parameters are settable through knob in front panel Engineering grade plastic enclosure( ABS) With CBCT Auxiliary supply: 110/230/415v, 50 HZ, Relay contact: 1 C/O contact with 6 Amp. (Resi.) Leakage current range: 30 to 100 ma 0.1 to 1 Amp 0.5 to 5 Amp. Reset: manual Operating temp. : -5 C to 60 C CBCT : 70,100,200,300 & 400mm Distribution panels for hotels, commercial complex, residential blocks, industrial complex. Mining industry On/ Off time is programmable 10 No of programme for On/Off Display of real time clock LED display for unit On Easy to programme Input supply : 415 +/- 20 % VAC Output : potential free 1 contact, 6 Amp at 230 VAC (Resi.) Water pump, street lights 22 23

EARTH LEAKAGE RELAY EARTH LEAKAGE CIRCUIT BREAKER (10.8.2) ELR-9601 Higher precision Flush mountable(92x92) Digital display of leakage current Parameters are programmable Engineering grade plastic enclosure( ABS) With CBCT Supply voltage : 85-265V AC, 50/60 Hz Relay contact : 1 change over (10.9.1) EL+MCB Load current rating : 16A / 25A / 32A System voltage: 230V AC, 1 phase, 50Hz, Sensitivity : 3-50 ma, Tripping time: <30 ms. High/low voltage cut off Overload short circuit protection Protection against shock and leakage current Potential free contact Positive safety output (relay will energies on fault) Contact rating: 6A at 230V AC / 30V DC Leakage current range : 30mA - 300mA 50mA - 999mA 150mA - 3A 250mA - 5A 500mA - 10A Trip time set: 00.1 to 10 sec. Display : digital 7seg. LED display Operating temp. : -5 c to 60 c CBCT 70, 100, 200, 300 & 400mm Distribution panels for hotels, commercial complex, residential blocks, industrial complex. mining industry. 24 25

PANEL METERS AUTOMATIC LIGHT CONTROLLER (10.10) AVM-101 Inbuilt C.T. Indicates phase to phase voltage Indicates system current Indication for phase through high bright LED Rotating voltage indication at fixed interval for different phase to phase Surface mountable (DIN standard) Aux. Supply : 415 +/- 20 % VAC Amp. Range : 4-40 Amp, 10-100 Amp (10.11.1) AUTOPHOTO Type AMPR PHASE APPLICATION ALC 6 ( I ) 1 6 Amp 1 Phase Indoor application ALC 10 ( I ) 1 10 Amp 1 Phase Indoor application ALC 10 ( O ) 1 10 Amp 1 Phase Outdoor application ALC 25 ( I ) 1 25 Amp 1 Phase Indoor application ALC 25 ( O ) 1 25 Amp 1 Phase Outdoor application ALC 16 ( O ) 3 16 Amp 3 Phase Outdoor application ALC 32 ( O ) 3 32 Amp 3 Phase Outdoor application ALC 63 ( O ) 3 63 Amp 3 Phase Outdoor application Control panels for housing, water pumps, industries, residential complex etc. 26 27

SINGLE PHASING PREVENTER WITH WATER LEVEL GUARD WATER LEVEL CONTROLLER (10.12.1) SWG Phase failure relay with dry run protection ( with Prod) Voltage sensing unit Engineering grade plastic (HIPS) enclosure Panel mountable Available with S.S. Sensor. Aux Supply: 415 +/- 20 % VAC, 50 Hz Output : 1 C/O, 6Amp @ 230 AC (Resi.) Over voltage: Above 480 VAC Under voltage : Below 320 VAC MCC panels for sewage pump (10.13.1) LLC-101 Easy to install DIN rail/ surface mountable Two tank controller Automatic control of starter according to set water level in tanks LED indications for water level in tank Specially for three phase motor starters Available with S.S sensors/magnetic sensors/float switch Engineering grade plastic enclosure(abs) System Voltage: 415 VAC +/- 20 %, 50 Hz Output : 1 CO contact,1 Amp. At 415 VAC, Pf=0.5 MCC of water pump in hotels, housed, high rise towers, societies, industries, commercial complexes, municipal water stations. (10.13.2) LLC-2 Easy to install Surface mountable Two tank controller Automatic control of starter according to set water level in tanks LED indications for water level in tank Specially for single phase motor Available with S.S sensors/magnetic sensors/float switch Engineering grade plastic enclosure(abs) System voltage: 230 VAC +/- 20 %, 50 Hz Output voltage: 230 VAC +/- 20 %, 50 Hz Capacity 30 A at 230 VAC ( Resi.) MCC panels of water pump in hotels, house, high rise towers, housing societies, industries, commercial complexes, municipal water stations. 28 29

WATER LEVEL CONTROLLER (10.13.3) LLC-2S Easy to install Two tank controller Automatic control of starter according to set water level in tanks LED indications for water level in tank Specially for single phase submersible pumps, semi automatic motor starters Available with S.S sensors/magnetic sensors/float switch Engineering grade plastic enclosure(abs) System voltage: 230 VAC +/- 20 %, 50 Hz Output voltage: 230 VAC+/- 20 %, 50 Hz Capacity 30 A at 230 VAC ( Resi.) MCC panels of water pump in hotels, house, high rise towers, housing societies, industries, commercial complexes, municipal water stations. (10.13.4) LLC-001/LLC-001D Water level controller adopter Usefull with GELCO make single or three phase DOL or FASD starters having adopter facility only Easy to install Surface mountable Two tank controller Automatic control of starter according to set water level in tanks LED indications for water level in tank Available with S.S sensors/magnetic sensors/float switch For GELCO starter having micro controller based technology use LLC-001 D Motor starter of water pump in hotels, house, high rise towers, housing societies, industries, commercial complexes, municipal water stations. 30 31

32