Ni-HARD SUBMERSIBLE PUMP

Similar documents
OPERATION & MAINTENANCE MANUAL PORTABLE SUBMERSIBLE PUMP

SUBMERSIBLE SEWAGE PUMP

DEWATERING PUMP. Instruction, Installation, Operation and Maintenance Manual. A Mark of Quality. ISO 9001 Certified Company

OPERATION & MAINTENANCE MANUAL POLDER PUMP. A Mark of Quality

HORIZONTAL SPLIT CASING PUMP

POLDER PUMPSET. ISO 9001:2008 Certified Company. A Mark of Quality

HORIZONTAL SPLIT CASING PUMP

SUBMERSIBLE SEWAGE AND EFFLUENT PUMPS

H 2. O Series CENTRIFUGAL End-suction Pumps. Versatile, really robust and definitely reliable

SUBMERSIBLE PUMP HSE RANGE

PROCESS PUMPS (INDIA) PVT LTD

SUBMERSIBLE PUMP HSE RANGE

SUBMERSIBLE SEWAGE PUMPS TYPE : NS

Heavy duty slurry pumps

Heavy duty slurry pumps

Thank you for selecting the GD submersible grinder pump.

Installation, Operation and Maintenance Manual Stancor SE, SV, SS & SC Series Pumps

GD series Submersible Grinder Pump

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

Submersible Sump/Drainage Pump

PUMP. Submersible Sewage Pumps Type DSC4 FEATURES/BENEFITS

INSTALLATION AND OPERATING INSTRUCTIONS

Domestic Pumps. Pumps. Self Priming Monoblock Pumps Open Well & Submersible Pumps

Installation & Operating Manual

Operating instructions for PXFLOW sewage pumps

Taro TEXMO INDUSTRIES. 75 mm & 100 mm BOREWELL SUBMERSIBLE PUMPSET PERFORMANCE CHART. Since 1956

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

SUBMERSIBLE WATER PUMPS

Taro TEXMO INDUSTRIES. 150 mm BOREWELL SUBMERSIBLE PUMPSET PERFORMANCE CHART. Since 1956

DSZ3. EBARA Submersible Propeller Pumps Contents Project: Model: Chk d: Date: Model

Domestic Pumps. Pumps. Self Priming Monoblock Pumps Open Well & Submersible Pumps

Operation & Maintenance Manual

SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514

Agri KAM INSTALLATION, OPERATION AND MAINTENANCE MANUAL. A View of KBL Dewas Manufacturing Plant. A Kirloskar Group Company KIRLOSKAR BROTHERS LIMITED

& AL RC-SERIES GB HSC 09-W13 Edition 5. T +31 (0) F +31 (0)

JUNG PUMPEN US SUBMERSIBLE DRAINAGE PUMPS

SUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2

MODELS HPGF/HPGFH, HPGH/HPGHH

PROCESS PUMPS (INDIA) PVT LTD

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

XLE50 FLOW RATE (LPM) Flow Rate (GPM)

Pump Specifications. ELV Series Submersible Sump Pump with OilTector Control. ELV250 1/3 hp ELV280 1/2 hp ELV290 3/4 hp

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

Technical Data DML. Submersible Sewage Pumps with Single Channel Impeller. DML_Techdata_SS_V11 EBARA PUMPS AUSTRALIA PTY. LTD.

JUNG PUMPEN MULTICUT SEWAGE PUMPS

Dry installed pump type LANDY BTP.

T E C H N I C A L M A

10 mm free passage. Submersible drainage pumps US Application. Safe to run dry. Easy to maintain with guide rail system. 10 mm free passage

ABS submersible sewage pump AFP

Pump Specifications LE100-Series 1HP Submersible Sewage Pump

Pump Specifications. D3648LSG, D3648LSGX Series Omnivore 2HP Duplex Grinder Packages LITERS PER SECOND

LITERS PER MINUTE GALLONS PER MINUTE

SINGLE PHASE CENTRIFUGAL MONOBLOCK ACS 11 & 15 SERIES INSTALLATION & SPARE PARTS MANUAL MANUFACTURED BY: AQUASUB ENGINEERING - UNIT II

Pump Specifications 250 Series Submersible Sump / Effluent Pump

Instruction Manual PN-Z PACKED PLUNGER PUMP. This Manual should be made available to person responsible for installation, maintenance and operation.

INSTRUCTION MANUAL AC2516 REVISION D INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. Series 1580 In-Line Mounted Centrifugal Fire Pumps

XFL70 FLOW RATE (LPM) Flow Rate (GPM)

NOTE: LEH100-Series high-head pumps require a minimum application of 15' head. Do not use pump in this area use a smaller pump.

EBARA Submersible Propeller Pumps Contents Project: Model: Chk d: Date: Model

PROCESS PUMPS (INDIA) PVT LTD

P P 3001 SERVICE INSTRUcTION

PROCESS PUMPS (INDIA) PVT LTD

INDIAN MARITIME UNIVERSITY KOLKATA CAMPUS

ESE Series Cast Iron Sewage Pumps

GRUNDFOS INSTRUCTIONS MTC. Installation and operating instructions

No: Revision Operation & maintenance manual. BRAVO SLURRY PUMPS

Pump Specifications LE40 Series 4/10 HP Submersible Sewage Pump Pump

Pump Specifications. LE50 Series ½ HP Submersible Sewage Pump

INSTALLATION, OPERATION & MAINTENANCE MANUAL FAHRENHEIT SK-F & SKX-F SERIES SHREDDER PUMPS Electric Submersible Pumps

Grey Water and Condensate Pump. Rotex. Type Series Booklet

Technical Data BEST 2~5. Stainless Steel Submersible Sump Pumps EBARA PUMPS AUSTRALIA PTY. LTD. Best 2-5_Techdata_SS_V10

SKHS SERIES 2 HP 1-1/2 HP 1 HP 1/2 HP CAPACITY-U.S. G.P.M.

SPnorm & SPbloc Self Priming Centrifugal Pumps

Pump Specifications FL50 Series 1/2 hp Submersible Effluent Pump

PROCESS PUMPS (INDIA) PVT LTD

Pump Specifications. Omnivore 2HP Submersible Grinder Pumps LSG200-SERIES (SINGLE STAGE) LSGX200-SERIES (TWO STAGE)

Installation, Maintenance and Operation manual 4 Submersible sand fighter pump. Type: SSFP - Series

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

JDL SYSTEMS Submersible Sump / Sewage Pumps Table of Contents Project: Model: Chk d: Date:

Operation & Maintenance Manual

- DIMENSIONS AND WEIGHT 400 PUMP DUMPER 1X SERIES 400 PUMP DUMPER 2X SERIES 401 PUMP DUMPER 3X, 4X, 5X, 6X, 7X, 8X SERIES 402 PACKING 403

Submersible Tank Pump

Pump Specifications 290 Series 3/4 hp Submersible Effluent Pump

Installation Manual. Omnivore Grinder Pump Retrofit Unit LSG202-RE. LSGX202-RE 2Hp, V, 1 phase, Automatic LSG202-REX

Pump Specifications 280 Series 1/2 hp Submersible Effluent Pump

REPAIR MANUAL 600 SERIES SUBMERSIBLE NON-CLOG UNITS CAUTION

CENTRIFUGAL PUMP AND SEAL (API Std. 610 and 682) Presented By Prakash Kumar ME(NSPL)

Submersible Pumps Model ST4125D Model ST6125D

& AL RW-SERIES GB HSC 08-W36 Edition 4. T +31 (0) F +31 (0)

VERTICAL TURBINE PUMP

Instruction Manual. * We reserve the right to amend specification without prior notice.

HYDROMATIC SKHS SERIES SUBMERSIBLE NON-CLOG, SEWAGE EJECTOR

Operation Manual Model: PPSSS Submersible Slurry Pump

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

PRE-PLUMBED SEWAGE SYSTEM

KW Submersible, Single-Vane Impeller

Operation & Maintenance Manual

Instruction for RBP250-3 and RBP300-3

Installation & Operating Manual

PROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS

Transcription:

Instruction, Installation, Operation and Maintenance Manual Ni-HARD SUBMERSIBLE PUMP 2018 mbh pumps (gujarat) pvt. ltd. ISO 9001 Certified Company A Mark of Quality

CROSS SECTION DRAWING NO. DESCRIPTION MATERIAL 1 CABLE PVC. INSULATED SHEATHED 2 GLAND COVER C.I. IS-210 FG260 3 EYE BOLT S.S. 4 TOP COVER C.I. IS-210 FG260 5 BEARING COVER C.I. IS-210 FG260 6 HEX BOLT S.S. 7 TOP BRG. COVER C.I. IS-210 FG260 8 HEX NUT S.S. 9 WINDING COPPER 10 END RING M.S. 11 STATOR STAMPING M-47 12 STATOR BODY C.I. IS-210 FG260 13 ROTOR SHAFT S.S. 410 14 BALL BEARING (D.E.) STD. MAKE 15 OIL CHAMBER C.I. IS-210 FG260 16 MECH. SEAL UPPER CR./ S.S. 17 MECH. SEAL LOWER SIC / SIC. 18 VOLUTE NI. HARD 19 IMPELLER NI. HARD 20 IMPELLER NUT S.S. 21 SPIRAL PLATE (WEAR PLATE) NI. HARD 22 STRAINER S.S. 23 PUMP STAND M.S. 24 CUTTER S.S. 25 NECK RING S.S. 26 OIL PLUG S.S. 27 OIL HYLUBE MILCY Gr, 40 28 BALL BEARING (NDE) STD. MAKE RECOMMENDATIONS 1. Follow maintenance schedule strictly, so as to avoid costly repairs in the long run. 2. MBH Ni-hard submersible pumpsets are being supplied with special features like over heating protection (Thermistor) and seal monitor sensor, control panel is a mandatory supply with each and every pumpset. Ensure that pumpset is connected properly to the control panel. 3. If pumping media available is falling short of the pump capacity, it will result in spurt, which is harmful for the pump. In such a case reduce discharge by throttling. 4. Ensure that pump rotates in correct direction (clockwise). Counter clockwise rotation result in lower discharge and increased wear. At instant of starting Ni-hard pump should give anticlockwise jerk. The rotation of impeller should match the arrow on the pump casing. In case of reverse rotation the current consumption will rise and pumpset will produce unwanted noise. 5. Avoid too many creases in the hosepipe (in case of portable installation), it results in increased friction losses. Use the shortest possible delivery line. 6. Protect cable from damage-during storage, transportation and operation. A damaged cable may give shock or burn the motor. 7. Always earth the unit, before starting. 8. Never hoist the pumpset up or down by the connecting cable. 9. Use NRV if pipe length is more than 4.5 mtrs. PRECAUTION FOR LONG STORAGE Clean the pump set with fresh water and wipe the cable. Put pump set in cool, dry place in vertical position and the cable wrapped on top of the pump. Do not leave cable on the floor where it is likely to get damaged. CONSTRUCTION OF NI-HARD SUBMERSIBLE PUMPSET MBH Ni-hard submersible pumps are of close couple compact design and have pump below and motor above construction hence sump cleaning is possible to the minimum level. These are powered by squirrel cage induction dry motors suitable for operation at 400/440 volts, 3 phase, 50 Hz, A.C. Supply; bearing of these pumps are grease packed. Being a Submersible pump, it saves a lot of cost of construction compared to other conventional pumps and also provides noise free operation. Pumps are fitted with high efficiency non-clog or free flow impeller for smooth and economical pumping operation. Since they work under pumping liquid, suction is always flooded, hence no need of priming or suction pipe. Pumps are fitted with double mechanical seals to separate motor chamber from oil chamber and oil chamber from liquid being pumped. Pumps are provided with special safety devices like moisture detection sensor and thermistor protection against high winding temperature. That can also be provided with special lowering arrangement for easy access of the pump for maintenance. PORTABLE MOUNTING The pump must be installed in vertical motor position above on a solid floor. For portable mounting, stand is supplied along with the pumpset. Suspend the pump from the chain and shackle attached to the eye bolt which is on the top cover. 2 3

WARNING Ensure that pump set rotates in the correct direction of rotation. Always operate pumpset with the original control panel supplied by the manufacturer. Never bypass any protection like Thermistor, Moisture sensor & Level controller. In case the pump set stops due to above protection, remove the pump set from sump and correct the defect. Protect the cable from damage. Ensure proper earthing of the pump set before starting. CABLE CONNECTION OF MOTOR TO CONTROL PANEL (1) D.O.L. CONNECTION 7 LEAD CABLE OR 4+4 LEAD CABLE MAINTENANCE Practically MBH Ni-hard submersible pumpset is totally maintenance free. However oil in seal chamber has to be checked every six months and needs to be replaced if quality gets deteriorated or it is to be changed after one year or 5000 working hrs. whichever is early. List of standard oil types is as under. u BPCL - Hydrol 46 / Turbol 46 u HPCL - Hylube-30 / Milcy-40 u IOC - Servo super 10 PROCEDURE OF OIL CHANGE Position the pump horizontally as shown in Fig. Place a suitable receptable under the threaded plug. Remove the plugs with O ring and drain the oil. If the oil is between light yellow and white in colour this means the seal is intact and the oil change can proceed. However, if there is more water than oil in the chamber you must inspect the mechanical seals and fit new ones if necessary Screw the threaded plugs, with O ring back in. CORRECT INSTALLATION A good water to slurry ratio. Sump level control - If the sump empties, the pump should switch itself off via the automatic control panel. The pump will switch on via a float switch or timer when the level rises. Pump should not exceed 20 starts per hour. The pump should be suspended by chains at least 200 mm from base of the sump to ensure maximum concentration of solids pumped. (2) STAR-DELTA CONNECTION 10 LEAD CABLE OR 4+4+4 LEAD CABLE A1, B1, C1 : Power Lead A2, B2, C2 : Power Lead (3) A.T.S. CONNECTION 4 CORE POWER CABLE & 4 CORE CONTROL CABLE (4) A.T.S. CONNECTION 2 PARALLEL POWER CABLE 4 CORE POWER CABLE & 4 CORE CONTROL CABLE 4 5

TROUBLE SHOOTING CHART Pump fails to deliver The discharge is too low The line current is excessive The total head is too low The power consumption is excessive Noisy operation of pump Ni-HARD SUBMERSIBLE PUMP CAUSE REMEDY Open the isolating valve further, The pump delivers against an until the duty point conditions have excessively high discharge pressure. been attained. The pump and / or piping are incompletely vented. Vent the pump & system completely. Suction line or impeller clogged. Remove deposits in the pump & piping. Change over two of the phase leads Reverse rotation. of the power supply cable. Excessive wear of the pump internals. Replace worn components by new one. Check the supply terminals inform Operating Voltage too low. the supply authorities. The motor is running on Replace the defective fuse, two phase only. check the cable connection. Clean the rotor, Rebalance the The rotor is out of balance. rotor dynamically. The motor refuses to run because Check the electrical system, there is no voltage. inform the supply authority. Clean out the inlet, Pump The pump is silted up. components & check valve. Defective motor or cable. Please consult our works. Replace defective lengths of riser Defective riser pipe. (pipe & gasket) pipe by new ones, fit new gasket. Abnormal (excessive) drop in the liquid level during operation. Please consult our works. The Star-Delta motor remains stuck at the star stage during start-up. Check the switchgear/control panel. The isolating valve in the discharge line is not fully open. Open the valve fully. Check the operating parameters Excessive amount of air or gas with reference to duty point. & in the liquid pumped. correctness of submergence. Defective Ammeter. Replace with new one. The insulation resistance of the winding is inadequate (The minimum resistance in warm condition during operation should Please consult our works. be 1000 ohms / volt of operating volt.) Defective radial bearing in the motor. Please consult our works. Vibration caused by improper installation. Correct the installation. The temp. sensor for monitoring the Wait for some time so that the motor temp. of winding in the control circuit cools down & the pumpset will start has stopped the motor because the automatically. winding temp is too high. 6 7 Ni-HARD SUBMERSIBLE PUMP The pump is warranty against defects in material and workmanship under normal use and service for the period of 15 months from the date of purchase or 12 months from the date of commissioning, whichever is less. The General terms and conditions for above warranty are : 1. This warranty is valid only if the pump is operated strictly as per the Instructions given in the user guide attached herewith. 2. Our obligation shall be limited to rectifying; repairing or replacing defective items, ex-works/service station/authorized Service Center, provided the purchaser has given immediate written notice. The equipment for repairs should be returned to us duly packed, on prepaid freight basis. Model : Customer Name : Address : Date of Purchase / Bill No.: Dealers Name : Pump Sr. No. Signature : Date : WARRANTY 14, G.I.D.C. Naroda Indl. Estate, Ahmedabad-382 330, India. Phone : 079-2282 3066 / 2282 1018 E-mail : marketing@mbhpumps.com / exports@mbhpumps.com Website : www.mbhpumps.com

OTHER PRODUCTS CENTRIFUGAL BACKPULL OUT PUMP HORIZONTAL SPLIT CASING PUMP SUBMERSIBLE SEWAGE PUMP PORTABLE SUBMERSIBLE PUMP SUBMERGED CENTRIFUGAL PUMP POLDER PUMP ISO 9001 Certified Company 14, G.I.D.C. Naroda Indl. Estate, Ahmedabad-382 330, India. Phone : 079-2282 3066 / 2282 1018 E-mail : marketing@mbhpumps.com exports@mbhpumps.com Website : www.mbhpumps.com A Mark of Quality marg 08/2018 This is the property of