MODEL RCW NON-INTERLOCK PREACTION SYSTEM

Similar documents
MODEL RCW DELUGE SYSTEM ELECTRIC, WET PILOT, AND DRY PILOT ACTUATION

SHORTER. LIGHTER. MORE VERSATILE. 1 VALVE 10 TRIM CONFIGURATIONS 4" AND 6" MODEL RCW WATER CONTROL VALVE FOR DRY, PREACTION AND DELUGE APPLICATIONS

MODEL UM UNIVERSAL MANIFOLD ASSEMBLY (With or Without Control Valve) 1¼", 1½", 2", 2½", 76.1mm, 3", 4", 6",165.1mm, 8"

TECHNICAL DATA 1-1/2 (dn40)

TECHNICAL DATA. Q= C v P S

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)

TECHNICAL DATA. Trimpac 249a. September 16, 2013

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

TECHNICAL DATA TRIMPAC MODEL B-4, B-4B & B-4S SINGLE INTERLOCK PREACTION SYSTEM WITH PNEUMATIC RELEASE

TECHNICAL DATA. Trimpac 244a. April 15, 2011

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE 6 (DN150)

Instructions for Installation, Operation, Care and Maintenance

DV-5a Automatic Water Control Valve Single Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

DV-5A Automatic Water Control Valve Remote-Resetting Deluge Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Wet Pilot Actuation General Description

DV-5a Automatic Water Control Valve Double Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

Preaction System with DV-5 Deluge Valve Double Interlock Electric/Electric Actuation. General Description. Page 1 of 14 DECEMBER 2014 TFP1465

Worldwide Contacts.

Instructions for Installation, Operation, Care and Maintenance

Instructions for Installation, Operation, Care and Maintenance

30.85 FireLock NXT Actuated Valve with LPCB Approved Preaction Trim

Technical Data. UL Listing is based on the following criteria:

TECHNICAL DATA. Q= C v P S FLOW CONTROL VALVE MODEL J-2 HALAR COATED 1-1/2 & 2 (DN40 & DN50) 1. DESCRIPTION

Instructions for Installation, Operation, Care and Maintenance

DELUGE VALVE DATA SHEET

TECHNICAL DATA CAUTION

Q= C v P S. Flow control valve Model j-2 Halar coated

Instructions for Installation, Operation, Care, and Maintenance

Model DDX Deluge Valves 4" (100 mm), 6" (150 mm) and 165 mm Sizes

Model DDX Deluge Valve 8 (200mm) Features

Instructions for Installation, Operation Care and Maintenance

MODEL UMC UNIVERSAL MANIFOLD CHECK ASSEMBLY

Features 1. Differential Latch-type, lightweight, dependable

1-1/2 Inch (DN40) 9 lb (4,1 kg) Groove Groove 1 8 lb (3,6 kg) Flange Groove 1 N/A N/A. Flange Flange N/A N/A

AGCX Bulletin 519 C/Alfoz de Bricia nº4 P.l. Villalonquéjar Burgos (Spain) Tlfno: PAG 1 de 50

TECHNICAL DATA. Table 1: Model F1 Dry Valve Part Numbers and Specifications

TECHNICAL DATA. Q= C v P S FLOW CONTROL VALVE MODEL H-2 HALAR COATED 2 (DN50) - 6 (DN150)

Instructions for Installation, Operation, Care and Maintenance

TECHNICAL DATA P S. Q= Cv MODEL E-2 DELUGE VALVE HALAR COATED ANGLE STYLE

TECHNICAL DATA. Notes: For use with Trim Charts on Pages 2-4

TECHNICAL DATA CONCENTRATE CONTROL VALVE APPLICATIONS, PRIMING CONNECTIONS, AND TRIMS 1. GENERAL DESCRIPTION 2. LISTINGS AND APPROVALS.

TotalPac 3 Deluge, Electric release Remote controlled system

TECHNICAL DATA. Q= C v P S. Table 1 - Valve Part Numbers and Specifications

Series 758 FireLock Actuated System Valve

TECHNICAL DATA 2-1/2-8 (dn65 - dn200)

TotalPac 3 Firecyle III Wet pipe Remote controlled system

FireLock NXT Deluge Valve. With Deluge Trim Grooved x Grooved. System No. Submitted By Spec Sect Para Location Date Approved Date

Easy Riser swing check valve Models E-1 & F-1

Model QRS Electronic Accelerator (Quick Opening Device) For Dry Pipe or Preaction Systems General Description

TotalPac 3 Deluge system Pneumatic release

Instructions for Installation, Operation, Care and Maintenance 2 PSI (0,14 bar) Pneumatic Supervising Pressure with Electric Actuation

Section M Dry Pipe Systems

Series 769 FireLock NXT Deluge Valve

Wet pipe low flow foam/water manifold system

TECHNICAL DATA. model f-1 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA. Page 1 of 11

TotalPac 3 Double interlock Preaction, Electric/Pneumatic release Remote controlled system

TECHNICAL DATA OBSOLETE

TotalPac 3 Non interlock Preaction, Electric release Remote controlled system

Series 756 FireLock Dry System Check Valve

FireLock NXT Actuated Valve with Preaction Trim. System No. Submitted By Spec Sect Para Location Date Approved Date

TotalPac 3 Non interlock Preaction system Pneumatic release

TotalPac 3 Double interlock Preaction, Electric/PneuLectric release Remote controlled system

Instructions for Installation, Operation, Care and Maintenance

TotalPac 3 Double interlock Firecyle III Preaction Remote controlled system

TECHNICAL DATA OBSOLETE. Inlet Type Outlet Type in mm. Thread Thread in. ANSI B Flanged Flanged in.

DV-5 Deluge Valve Aluminium Bronze Diaphragm Style General Description

Section O Preaction Systems

CJ=TN=- FRONT DELUGE VALVE, EXTERNAL RESETTING. MODEL F470 MULTIMATIW - 4 and 6 INCH (100 and 150 mm) a P il

CIRCLE SEAL CONTROLS

FireFlex DUAL Single Interlock, Remote controlled system

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

NYLON & PVC VALVES MINING DIVISION PRESSURE REDUCING VALVES ENSURE DOWNSTREAM PRESSURE PVC NYLON

Section P Flow Control and Pressure Regulation

January 2007 Approval Guide Fixed Extinguishing Systems 5-57

CIRCLE SEAL CONTROLS

Table Summary of Sprinkler System Inspection, Testing, and Maintenance. Reference. Inspection , ,

Section L Wet Pipe Systems

Model RM-1 Riser Manifold Commercial and Residential General Description

Installation Instructions

Series 751 FireLock European Alarm Check Valve Stations

Section P Flow Control and Pressure Regulation

Double Diaphragm with Pressure-Type Leak Detector. For MILROYAL, CENTRAC B And MAXROY

Holding. Resistance. Inrush. Watts. Amps. Amps. (ohm)

PRESSURE RELIEF / SURGE ANTICIPATOR CONTROL VALVE

4077 AIRPARK DRIVE STANDISH, MICHIGAN PHONE FAX

Grooved Piping System for Fire Protection Services

Section N Deluge Systems

PRESSURE RELIEF / SUSTAINING CONTROL VALVES

Cla-Val. Service Training Manual. Simple solutions plus learning with a purpose

GW MKIII DELUGE VALVE - ALUBRONZE EXTERNAL RESET, PNEUMATIC

COMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES 2.01 COMBINATION RESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVE

SOLENOID CONTROL VALVE

Series 867 Reduced Pressure Zone Assemblies

Section R Foam Systems

Section R Foam Systems

TECHNICAL DATA. Notes: For use with Trim Charts on Pages 227b - d

Technical Data TYPE T124 & T134 TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4512A

Transcription:

GENERAL DESCRIPTION The Globe Model RCW non-interlock preaction valve is a hydraulically operated external resetting differential latching style valve designed for use where quickopening and total flooding of sprinkler system piping is desired. The Model RCW valve is used as an automatic water control valve in non-interlock preaction applications. The Model RCW valve serves as the primary water control valve installed in the water supply to a non-interlock preaction sprinkler system incorporating automatic sprinklers with supervisory air monitoring the integrity of the system piping. Setting of the Model RCW non-interlock preaction system requires water in the pressure chamber being maintained on the plunger rod. The pressure on the plunger rod which keeps the latch against the clapper closed keeps the supply water from entering the sprinkler system piping. Water pressure is provided to the pressure chamber through a connection to the main water supply at a point upstream of the system main control valve. This connection also supplies water pressure up to the solenoid valve, and to a dry pilot actuator. In the standby condition, the valve is normally closed and will automatically activate (trip) upon the activation of the detection system, which may be electrical or mechanical in nature depending on the type of system, or an operation of an automatic sprinkler as a result of a fire condition. The RCW valve may also be operated by means of a manual release, which is provided in the trim of all non-interlock preaction valve trim configurations, to override the automatic detection system. When heat from a fire opens an automatic sprinkler, or operates an electric device, water pressure in the pressure chamber decays through either the dry pilot actuator or solenoid valve respectively. The loss in pressure chamber pressure results in the movement of the push rod assembly, releasing the lever/roller assembly from the clapper. The system water supply pressure forces the valve clapper open resulting in water flow into the system piping making water available to the automatic sprinklers. Upon system activation, fire alarm signaling is provided by means of flowing water through the alarm port/intermediate chamber and associated alarm line trim. Water discharges from the automatic sprinkler once the operating element of the automatic sprinkler is activated by the heat of the fire. The flow of water activates a pressure switch which in turn notifies local alarms and/or an alarm signaling monitoring service. After the main control valve has been shut, the system drained and the detection system has been reset, the RCW non-interlock preaction 0 Airpark Dr. Standish, MI 8658 989-86-58 www.globesprinkler.com Technical Support 989--00 techservice@globesprinkler.com MODEL RCW NON-INTERLOCK PREACTION SYSTEM MODEL RCW NON-INTERLOCK INTERLOCK PREACTION valve is easily set/reset by means of pushing the reset knob. The reset knob returns the clapper to the closed position, without needing to remove the cover plate of the valve. Note: See technical datasheet GFV-565 for solenoid valve selection and panel compatibility. More information can be found on the dry pilot actuator operation in technical datasheet GFV-5. TECHNICAL DATA Approvals 00 psi (.6 Bar)-cULus/FM Maximum System Working Pressure (Dependent on solenoid valve selection- Standard offering 5 psi (2 Bar)) 00 psi (.6 Bar)- culus/fm End Connections Groove x Groove Materials of Construction See Technical Datasheet GFV 0 for materials of construction for the Model RCW Valve *Patents Pending NOV 8 REV. A GFV- Page of

SYSTEM PIPING WITH AUTOMATIC SPRINKLERS ELECTRIC DETECTION SYSTEM (TYPICALLY 2 VOLTS DC) HEAT DETECTORS, SMOKE DETECTORS, ETC. ELECTRIC SOLENOID VALVE DRAIN DRAIN SYSTEM AIR GAUGE DRY PILOT ACTUATOR SYSTEM LOW AIR PRESSURE ALARM SWITCH AUTOMATIC AIR/NITROGEN MAINTENANCE FOR SYSTEM AIR RELEASING PANEL (AUTOMATIC CONTROL UNIT) POWER SUPPLY (TYPICALLY VOLTS AC) LOCAL MANUAL CONTROL STATION DRAIN (NORMALLY CLOSED) PRESSURE CHAMBER SUPPLY CONTROL VALVE (NORMALLY OPEN) RESTRICTION MAIN DRAIN VALVE (NORMALLY CLOSED) WATERFLOW PRESSURE ALARM SWITCH WATER SUPPLY PRESSURE GAUGE MAIN CONTROL VALVE (NORMALLY OPEN) WATER SUPPLY FIGURE :NON-INTERLOCK PREACTION ACTUATION SCHEMATIC VALVE SIZE NOMINAL INSTALLATION DIMENSIONS INCHES (MM) A B C D E F G H I J " (DN00). (8).96 () 8.6 (9) 5.05 (82) 6.92 (0) 2. (2).06 (9). ().62 (295) 9.5 (2) 6" (DN). (8).96 () 9. (2) 5.8 (02) 6.9 ().9 () 8.5 (5). (68).6 (296) 9. (2) FIGURE 2:NON-INTERLOCK PREACTION TRIM DIMENSIONS NOV 8 REV. A GFV- Page 2 of

FIGURE : " RCW NON-INTERLOCK PREACTION ACTUATION TRIM ARRANGEMENT 5 55 6 8 8 2 28 5 5 5 2 5 6 56 2 5 2 29 8 9 6 22 2 0 9 5 8 2 2 9 6 TO OPTIONAL WATER MOTOR ALARM 2 5 2 8 62 5 FROM FROM AIR MAINTENANCE AIR MAINTENANCE 66 2 NOTE: SOLENOID INCLUDED. IF OTHER THAN STANDARD, INFORM CUSTOMER SERVICE AT TIME OF ORDER 9 5 52 52 8 9 ITEM NO. PART NO. DESCRIPTION QTY. ITEM NO. PART NO. DESCRIPTION QTY. 0802-G 2" x " GALV. NIPPLE 22-G /" x /2" GALV. STREET ELBOW 2 8-G 2" 90 GALV. ELBOW 80 " CHECK VALVE (FxF) 006-G /2" x " GALV. NIPPLE 5 -G /2" x /2" x /" GALV. TEE 2 00-G /2" x /2" GALV. NIPPLE G580 SOLENOID VALVE WITH 2V DC COIL 5 005-G /2" x /2" GALV. NIPPLE 2 8 95 /2" RESTRICTOR 6 200 VELOCITY CHECK VALVE 9 0-G /" GALV. UNION 696-R /2" BALL VALVE MXF - RED HANDLE 2 0 00-G /" x 2" GALV. NIPPLE 8 -G /" x /2" x /" GALV. TEE 9-GR /2" BALL VALVE MxM - GREEN HANDLE 9 98 DRIP ASSEMBLY 2 008-G /2" x 5" GALV. NIPPLE 0-G /" x /2" GALV. NIPPLE 68 /" -WAY VALVE 2 2 005-G /" x /2" GALV. NIPPLE 00 PS-0-2 ALARM SWITCH 00-G /" GALV. PLUG 5 00 PS-0-2 ALARM SWITCH 009-D -/2" WATER GAUGE (00PSI) 2 6 00-G /2" x " GALV. NIPPLE 5 00-D -/2" AIR GAUGE (2PSI) -G /2" GALV. ELBOW 5 6 0-G /2" GALV. STREET ELBOW 2 8 -G " GALV. STREET ELBOW 00-G /2" GALV. CROSS 2 9 99-R 2" BALL VALVE (FxF) - RED HANDLE 8 00-G /" GALV. PLUG 0800-G 2" CLOSE GALV. NIPPLE 2 9 86 /" CHECK VALVE MxF 5 8-G 2" x 2" x " GALV. TEE 0-G /2" GALV. UNION 52 0-G " x 2" GALV. NIPPLE 2 05-G /2" x /" x /2" GALV. TEE 5 002-G /2" x 2" GALV. NIPPLE 2 22 06 /" TUBE CONNECTOR 55 00-G /" x /2" GALV. NIPPLE 2 M-60 /" COPPER TUBE - 56 55 DRY PILOT ACTUATOR 2 06 /2" ELBOW TUBE CONNECTOR 5 0-G /2" GALV. TEE 06 /2" TUBE CONNECTOR 2 62 5 /" PRESSURE RELIEF VALVE (ADJ. PSI) FACTORY SET @ 5PSI M-59 /2" COPPER TUBE - 66 00-G /2" x 6" GALV. NIPPLE 2 9 /2" Y-STRAINER 2 802 /2" CHECK VALVE MxF 28 96 /2" SPRING LOADED CHECK VALVE 08-G /2" x 2" GALV. NIPPLE 29 9-R /2" BALL VALVE MxM - RED HANDLE 8 696-GR /2" BALL VALVE MxF - GREEN HANDLE 002-G /" GALV. CROSS 9 00-G /" x 6" GALV. NIPPLE 2 2-G /" x /2" GALV. REDUCING ELBOW 8 02-G /2" x 9" GALV. NIPPLE NOV 8 REV. A GFV- Page of

FIGURE : 6" RCW NON-INTERLOCK PREACTION ACTUATION TRIM ARRANGEMENT DETNO PARTNO DESCRIPTION QTY. 0802-G 2" x " GALV. NIPPLE 2 8-G 2" GALV. ELBOW 006-G /2" x " GALV. NIPPLE 2 00-G /2" x /2" GALV. NIPPLE 6 5 005-G /2" x /2" GALV. NIPPLE 2 6 200 VELOCITY CHECK VALVE 696-R /2" BALL VALVE (MxF) - RED HANDLE 2 8 -G /" x /2" x /" GALV. TEE 9 98 DRIP ASSEMBLY 0-G /" x /2" GALV. NIPPLE 2 005-G /" x /2" GALV. NIPPLE 00-DG /" DOM. GALV. PLUG 009-D /2" WATER GAUGE (00PSI) 2 5 00-D /2" AIR GAUGE (2PSI) 6 0-G /2" GALV. STREET ELBOW 2 00-G /2" GALV. CROSS 2 8 00-G /" GALV. PLUG 9 86 /" CHECK VALVE (MxF) 0-G /2" GALV. UNION 05-G /2" x /" x /2" GALV. TEE 22 06 /" TUBE CONNECTOR 2 M-60 /" COPPER TUBE - 2 06 /2" ELBOW TUBE CONNECTOR 06 /2" TUBE CONNECTOR 2 M-59 /2" COPPER TUBE - 2 9 /2" Y-STRAINER 28 96 /2" SPRING LOADED CHECK VALVE 29 9-R /2" BALL VALVE (MxM) - RED HANDLE 002-G /" GALV. CROSS 2 2-G /" x /2" GALV. REDUCING ELBOW 22-G /" x /2" GALV. STREET ELBOW 80 " CHECK VALVE (FxF) 5 -G /2" x /2" x /" GALV. TEE 2 G580 SOLENOID VALVE WITH 2V DC COIL 8 95 /2" RESTRICTOR 9 0-G /" GALV. UNION 0 00-G /" x 2" GALV. NIPPLE 9-GR /2" BALL VALVE (MxM) - GREEN HANDLE 2 008-G /2" x 5" GALV. NIPPLE 68 /" -WAY VALVE 2 00 PS-0-2 ALARM SWITCH 5 00 PS-0-2 ALARM SWITCH 6 00-G /2" x " GALV. NIPPLE 2 -G /2" GALV. ELBOW 5 8 -G " GALV. STREET ELBOW 9 99-R 2" BALL VALVE (FxF) - RED HANDLE 0800-G 2" CLOSE GALV. NIPPLE 2 5 8-G 2" x 2" x " GALV. TEE 52 0-G " x 2" GALV. NIPPLE 2 5 002-G /2" x 2" GALV. NIPPLE 55 00-G /" x /2" GALV. NIPPLE 56 55 DRY PILOT ACTUATOR 5 0-G /2" GALV. TEE 62 5 /" PRESSURE RELIEF VALVE (ADJ. PSI) FACTORY SET @ 5PSI 66 00-G /2" x 6" GALV. NIPPLE 68 002-G /" x 2 /2" GALV. NIPPLE NOTE: 2 802 /2" CHECK VALVE MxF (NINGBO) 08-G /2" x 2" GALV. NIPPLE 8 696-GR /2" BALL VALVE (MxF) - GREEN HANDLE 9 00-G /" x 6" GALV. NIPPLE SOLENOID INCLUDED. IF OTHER THAN STANDARD, INFORM 82 0-G /2" x 0" GALV. NIPPLE CUSTOMER SERVICE AT TIME OF ORDER 6 8 82 2 28 5 5 2 5 6 56 5 2 5 5 55 2 29 2 5 68 8 0 9 22 2 8 5 2 6 8 62 6 9 9 5 FROM FROM 5 2 AIR MAINTENANCE AIR MAINTENANCE 6 2 9 52 66 2 52 TO OPTIONAL WATER MOTOR ALARM 8 5 2 9 ITEM NO. PART NO. DESCRIPTION QTY. ITEM NO. PART NO. DESCRIPTION QTY. 0802-G 2" x " GALV. NIPPLE 22-G /" x /2" GALV. STREET ELBOW 2 8-G 2" 90 GALV. ELBOW 80 " CHECK VALVE (FxF) 006-G /2" x " GALV. NIPPLE 2 5 -G /2" x /2" x /" GALV. TEE 2 00-G /2" x /2" GALV. NIPPLE 6 G580 SOLENOID VALVE WITH 2V DC COIL 5 005-G /2" x /2" GALV. NIPPLE 2 8 95 /2" RESTRICTOR 6 200 VELOCITY CHECK VALVE 9 0-G /" GALV. UNION 696-R /2" BALL VALVE MxF - RED HANDLE 2 0 00-G /" x 2" GALV. NIPPLE 8 -G /" x /2" x /" GALV. TEE 9-GR /2" BALL VALVE MxM - GREEN HANDLE 9 98 DRIP ASSEMBLY 2 008-G /2" x 5" GALV. NIPPLE 0-G /" x /2" GALV. NIPPLE 68 /" -WAY VALVE 2 2 005-G /" x /2" GALV. NIPPLE 00 PS-0-2 ALARM SWITCH 00-G /" GALV. PLUG 5 00 PS-0-2 ALARM SWITCH 009-D -/2" WATER GAUGE (00PSI) 2 6 00-G /2" x " GALV. NIPPLE 2 5 00-D -/2" AIR GAUGE (2PSI) -G /2" GALV. ELBOW 5 6 0-G /2" GALV. STREET ELBOW 2 8 -G " GALV. STREET ELBOW 00-G /2" GALV. CROSS 2 9 99-R 2" BALL VALVE (FxF) - RED HANDLE 8 00-G /" GALV. PLUG 0800-G 2" CLOSE GALV. NIPPLE 2 9 86 /" CHECK VALVE MxF 5 8-G 2" x 2" x " GALV. TEE 0-G /2" GALV. UNION 52 0-G " x 2" GALV. NIPPLE 2 05-G /2" x /" x /2" GALV. TEE 5 002-G /2" x 2" GALV. NIPPLE 22 06 /" TUBE CONNECTOR 55 00-G /" x /2" GALV. NIPPLE 2 M-60 /" COPPER TUBE - 56 55 DRY PILOT ACTUATOR 2 06 /2" ELBOW TUBE CONNECTOR 5 0-G /2" GALV. TEE 06 /2" TUBE CONNECTOR 2 62 5 /" PRESSURE RELIEF VALVE (ADJ. PSI) FACTORY SET @ 5PSI M-59 /2" COPPER TUBE - 66 00-G /2" x 6" GALV. NIPPLE 2 9 /2" Y-STRAINER 68 002-G /" x 2 /2" GALV. NIPPLE 28 96 /2" SPRING LOADED CHECK VALVE 2 802 /2" CHECK VALVE MxF 29 9-R /2" BALL VALVE MxM - RED HANDLE 08-G /2" x 2" GALV. NIPPLE 002-G /" GALV. CROSS 8 696-GR /2" BALL VALVE MXF - GREEN HANDLE 2 2-G /" x /2" GALV. REDUCING ELBOW 9 00-G /" x 6" GALV. NIPPLE 82 0-G /2" x0" GALV. NIPPLE NOV 8 REV. A GFV- Page of

INSTALLATION AND MAINTENANCE INSTALLATION Proper operation of the RCW Valve (i.e., opening of the RCW Valve as during a fire condition) is highly dependent on the correct installation of the trim. It is necessary to install the trim components as described in the figures above for the valve to function properly. Failure to do so may prevent the valve from functioning and could void Listings, Approvals, and/or the manufacturer's warranty. All tubing directed to the "drip cup" must have smooth bends. Abrupt changes in direction or kinks in the tubing could result in a restriction of flow and an adverse effect on the functionality of the valve. The Model RCW Valve must be installed in an accessible and visible location, which is maintained at or above a minimum temperature of 0ºF (ºC). The RCW Valve must be installed in the vertical orientation. All valves must be installed in accordance with the appropriate installation standard (i.e. NFPA, NFPA 5 or other). All electrical connections must be made per the applicable installation standard and/or the National Electric Code (i.e. NFPA 0, NFPA 2 or other). Proper hydrostatic test procedure must be followed per NFPA. The velocity check valve must be replaced with a plug temporarily, the pressure chamber must be vented during the hydrostatic test procedure by opening the manual release valve and the clapper must be latched in the open position. NON-INTERLOCK PREACTION VALVE SETTING PROCEDURE The following steps are to be followed for initial setting of the Model RCW non-interlock preaction system valve, after a trip test of the fire protection system or, after any system operation. STEP. Close the main control valve. STEP 2. Close the pressure chamber supply control valve and the system air supply valve. STEP. Open the main drain valve, lower body drain valve, and all low point drain valves and auxiliary drain valves on the system. Open the manual emergency release control valve. Depress the plunger of the automatic drain valve to verify that it is not under pressure and that the system piping is completely drained. After system is completely drained, close all low point and auxiliary drain valves that were open. The manual emergency release control valve and main drain valve should remain open until directed in the following steps. STEP. Depress the reset plunger located at the top of the pressure chamber to reset the clapper of the RCW valve (the sound of the clapper falling into position should be heard). Close the manual emergency release control valve. STEP 5. Open the remote test valve. Replace any operated automatic sprinklers that operated with the same type, i.e. Orientation, orifice, temperature, and thermal sensitivity. Close the remote test valve. STEP 6. The detection system is to be cleared and reset in accordance with the detection system and/or control panel manufacturer s instructions. Once reset, verify the solenoid valve is closed (deenergized). When closed, the solenoid valve should have no magnetic charge on the nut on the top of the coil. Test the nut to make sure it is has no magnetic charge by contacting the nut with a conductive item such as a screwdriver. If still magnetized, the detection system/panel is not properly set for service. STEP. Open the system air supply valve to re-establish normal system air pressure. STEP 8. Open the manual emergency release control valve and then the pressure chamber supply control valve. Slowly close the manual emergency release control valve and allow pressure to build up in the pressure chamber, up to the dry pilot actuator and solenoid valve. STEP 9. Observe all drain tubing at the drip cup. If any leakage is observed, the source of the leakage must be identified and corrected. STEP 0. Partially open the main control valve. Slowly close the main drain valve when water discharges from the drain connection. Observe the supply pressure gauge and the pressure chamber gauge, they should indicate the same pressure reading. Depress the plunger on the automatic drip check valve for leaks. If leakage is apparent, the cause of the leakage must be identified and corrected. If there are no leaks, open the system control valve fully. STEP. Clear/reset the releasing control panel to clear any supervisory conditions that connected to the system control valve. Once the panel is reset and clear, the system is set for service. TESTING Reference NFPA, Standard for the Inspection, Testing and Maintenance of Water-Based Fire Protection Systems. Before proceeding with any tests involving water flow, the following precautions need to be taken: STEP. Check the location where the test connection discharges to make sure that all is clear and that there is no possibility of the water flow causing damage or injury. STEP 2. Check the end of the test connection to make sure that it is unobstructed. To achieve a satisfactory test, there must be an unrestricted flow of water when the test valve is wide open. STEP. Check for alarm connections to a central station or fire department. If such connections are found, give proper notice to the signal receiving station before proceeding with the test. Note: A main drain test may also operate local fire alarms unless they are temporarily disabled. NON-INTERLOCK PREACTION TRIP TEST PROCEDURE Proper operation of the RCW Valve (i.e., opening of the RCW Valve as during a fire condition) must be verified, at or more frequently than described by the applicable Inspection NOV 8 REV. A GFV- Page 5 of

Testing and Maintenance Standard (i.e. NFPA ) or by the Local AHJ. Globe Sprinkler Corporation recommends performing a trip test annually. The steps to perform a trip test are as follows: STEP. If a partial flow trip test is required perform the following additional steps, if a normal flow test is being performed continue to Step 2:. Close the main control valve. 2. Open the main drain valve.. Open the main control valve one turn beyond the position at which water just begins to flow from the main drain valve.. Close the main drain valve. 5. In step be sure to close the main control valve quickly after the trip of the valve has been verified. STEP 2. Test the Non-interlock Preaction releasing panel in accordance with the manufacturer s instructions to energize the solenoid valve or open the test connection at the end of the system. Either operation will cause the valve to trip. STEP. Verify that the RCW Valve has tripped, as indicated by the flow of water into the system and activation of the water flow alarm. STEP. Close the system s Main Control Valve. STEP 5. Close the Diaphragm Chamber Supply Control Valve. STEP 6. Reset the RCW Non-interlock Preaction Valve in accordance with the Non-interlock Preaction Valve Setting Procedure. NON-INTERLOCK PREACTION- WATERFLOW ALARM TEST PROCEDURE Testing of the system water flow alarms must be performed as described by the applicable Inspection Testing and Maintenance Standard (i.e. NFPA ) or as described by the Local AHJ. To test the water flow alarm, open the Alarm Test Valve, which will allow a flow of water to the Pressure Alarm Switch and/or Water Motor Alarm. Upon satisfactory completion of the test, close the Alarm Test Valve. MAINTENANCE Note: All valves should be carefully inspected, tested, and maintained in accordance with NFPA or other applicable Standard. It is important to ensure a clean water supply free of debris and solid particles such as sand, gravel, or mud. If, during an inspection of a water control valve, sediment or free particles of matter are noted, a further examination of internal valve parts is necessary. All deposits should be removed from all operating parts and ports. Vent holes through intermediate chamber should be thoroughly cleaned and flushed with clean water. Where difficulty in performance is experienced, the manufacturer or its authorized representative shall be contacted before any field adjustment is to be made. Clapper Facing. The rubber clapper facing should be checked for wear or damage to determine that it is free of dirt and other foreign substances. If found to be worn or damaged (e.g., foreign matter embedded in the surface), the facing should be replaced. If it is dirty, it should be cleaned. Compounds which could damage the rubber facing must never be used. Seat Ring. The seat ring should be checked for nicks and for stones, dirt or other foreign matter lodged in the grooves or holes. It should be cleaned thoroughly. If the seat ring is found to be damaged, valve should be replaced. Alarm Line Check Valve. The ¾ check valve connected to the intermediate chamber should be checked for clapper and seat condition. RCW Valve. Main Drain Valve and all controlling valves which are normally closed when the deluge valve is in the set position should be checked to be sure that they are fully closed and not leaking. ORDERING INFORMATION The RCW Valve with Non-Interlock Preaction; trim can be ordered pre-trimmed or non-assembled as separate items. The standard offering comes with galvanized nipples and fittings (Standard galvanized trim is not domestic). For nonassembled the following items must be ordered separately: RCW Water Control Valve Non-Interlock Preaction Trim Automatic Air Supply (Air Maintenance Device) Accessories (as needed) Pre-Trimmed With Model GLR00G Control Valve Standard solenoid valve is the Parker 2 VDC; 5 psi rated solenoid. If different solenoid valve is desired, inform Customer Service at time of order placement. Pre-Trimmed RCW Non-Interlock w/ BFV Contol Valve Specify: RCW Non-Interlock Pretrimmed w/ BFV(specify valve size), PN: Inch G x G...66-B Inch G x G...66-B-LP 6 Inch G x G...0-B 6 Inch G x G...0-B-LP DN (65, mm) GXG...0-D-B DN (65, mm) GXG...0-D-B-LP PRE-TRIMMED WITHOUT GROOVED BFV CONTROL VALVE Pre-Trimmed RCW Non-Interlock Actuation Specify: RCW Non-Interlock Pretrimmed (specify valve size), PN: Inch G x G...66 Inch G x G...66-LP 6 Inch G x G...0 6 Inch G x G...0-LP DN (65, mm) GXG...0-D DN (65, mm) GXG...0-D-LP NOV 8 REV. A GFV- Page 6 of

NON-ASSEMBLED Valve body ordered separately Solenoid Valve Included Trim Kit includes extra pieces to accommodate different size valves RCW Water Control Valve Specify: RCW Valve Only (specify valve size) inch RCW GxG...00 inch RCW GxG...00-LP 6 inch RCW GxG...5 6 inch RCW GxG...5-LP DN (65, mm) RCW GXG...5-D DN (65, mm) RCW GXG...5-D-LP GLOBE PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). RCW Non-Interlock Trim Kit inch or 6 inch or DN Specify: RCW Non-Interlock Trim Kit, PN Non-Interlock Trim Kit...65 Non-Interlock Trim Kit...65-LP Solenoid Valve A Solenoid Valve compatible with the anticipated maximum water supply pressure and releasing panel when ordering a non interlock actuation trim. Refer to Technical Data Sheet GFV565 for ordering information. Specify: 2 VDC, (5 psi, 2 psi or 00 psi) Solenoid Valve: ASCO 5 psi (2 Bar) UL/FM....G89G ASCO 00 psi (. Bar) UL/FM...GHV2900 *Skinner 5 psi (2 Bar) UL/FM..... G580 Skinner 2 psi (.2 Bar) UL/FM...G5802 *Standard Model H-, H-2 or H- Air Maintenance Device Specify: Model (Specify Model) Air Maintenance Device (see Part Number below) H-...585 H-2...595 H-...600 See Technical Literature G- and G-2 for more information on Air Maintenance Devices Note: 00 psi (.6 Bars) Pressure Gauges Standard (600 psi (.2 Bars)) Ordered Separately) PN...00-D NOTE: See trim drawings for trim replacement part numbers See Technical Data Sheet GFV0 for RCW Valve replacement part numbers 0 Airpark Dr. Standish, MI 8658 Ph. 989-86-58 Technical Support -800-28-028 techservice@globesprinkler.com www.globesprinkler.com NOV 8 REV. A GFV- Page of