Gas and air filter. GF/1: Rp 1/2 - Rp 2 GF/3: DN 40 GF/4: DN 50 - DN 100 GF: DN DN 200

Similar documents
Manually operated safety shut-off valve HSAV HSAV/5

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function Integrated bypass valve MB-D(LE) B07

Double solenoid valve Rp 3/8 - Rp 2 nominal diameters DMV-D/11 DMV-DLE/11

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) 403 B01

MBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N

MBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function Integrated bypass valve MB-D(LE) B07

Old documentation - Only for your information! Product is not available any more!

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) 403 B01 MB-D(LE) 053 B01

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

Differential pressure switches for air, flue and exhaust gases GGW A4-U/2

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) B01

GasMultiBloc Combined regulator and safety shut-off valves Two-stage function Integrated bypass valve MB-ZRD(LE) B07

Differential pressure switches for air, flue and exhaust gases Pressure switch for gas

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) B01

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

Pressure switch for gas, GW 500 A4 GW 500 A4/2

High-pressure switch for gas, air, flue gases and combustion products GW A4/2 HP

GasMultiBloc Combined regulator and safety shut-off valves Two-stage function MB-ZRD(LE) B01

Valve monitoring system VDK 200 A S02

High-pressure switch for gas, air, flue gases and combustion products GW 500 A4 GW A4/2 HP

High-pressure switch for gas, air, flue gases and combustion products GW A4/2 HP

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

Two-stage safety solenoid valves ZRLE/5, ZRDLE/5

Double solenoid valve Rp 2 (DN 50) DN 65 - DN 125 nominal diameters. DMV/11 eco DMV-D/11 eco DMV-DLE/11 eco

Two-stage safety solenoid valves ZRD/5, ZRLE/5, ZRDLE/5

Old documentation - Only for your information! Product is not available anymore!

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Installation and Operating Instructions DDM-DS11 DDM-DS11-MS1 DDM-DS11-MS2

Special gas range Biogas range

Process Inline Filter Protective filter PLF2-9HF

Process Inline Filter PLF1

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

3/2-way Miniature Rocker Solenoid Valve for pneumatic systems

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG Variable air/gas ratio control with solenoid valve VAV

Suction Filters S8-455 SE56-560

Gas pressure regulator R 100 / R 100U / R 100UD

VF VFH. elektrogas.com. Butterfly valves DN40 DN150 EE155-11/11

Valve testing system VPS 504 for multiple actuators

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 057 D01

Governor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

3/2-way Solenoid Valve for pneumatics

VKF41...C. Butterfly Valves. Building Technologies Division Industry Sector

VGD20... VGD40... Double Gas Valves. Siemens Building Technologies Landis & Staefa Division

Wafer check valve RSK 500

Replacement cartridge filter

2/2-way Globe Valve for media up to +180 C, DN

3/2-way Miniature Rocker Solenoid Valve for pneumatic systems

Tightness control TC. Product brochure GB Edition 12.10

Type 6213 EV, 6281 EV

Valves, controls + systems Valves and controls for solar installations Regusol-180

Proportional controlling element

Process Inline Filter Medium / High Pressure PFM / PFH

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Strainer SF 305. Sealing FPM EPDM

Volumeter. RMG Meßtechnik GmbH. Publication No E

VML. elektrogas.com. Safety solenoid valves for gas Slow opening and fast closing type DN10 DN80 EE

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

N086, N186, N786. Pressure retaining valve, Plastic

Volumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas

Wafer check valve RSK 500

The installation and maintenance of this product must be done under the supervision of an experienced

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

VLF45... Hot Air Valves. Building Technologies Division

Process Multi-Rheo Filter PMRF

Return Line Filter HF4R up to 450 l/min, up to 10 bar

Contents Technical characteristics Han A Technical characteristics Han 3 A with HARAX Termination

VLF45... Hot Air Valves. Siemens Building Technologies HVAC Products

Double regulating and commissionig valves Hydrocontrol F cast iron, PN 16 Hydrocontrol FR bronze, PN 16 Hydrocontrol FS nodular cast iron, PN 25

-Q- Temperature range C. -L- Operating pressure bar. Vacuum filters ESF Technical data. Function

Excess pressure regulator Excess pressure regulator, straight through DN

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Process screen basket filter PRFS

ES 134 ES 144 Tank top mounting Connection up to SAE 1½ Nominal flow rate up to 130 l/min

Type TW17 FUTURE. TECHNOLOGY. TODAY. WEH Connector for pressure and function testing. DatA Sheet. on components with internal thread

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

Assembly and operating Instructions RA 60 / FA 60

SERIES 2000 GAS SAFETY SHUT OFF VALVE

Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread

Safety Shut-off Valve SL/SID/RSL

ES 094 Tank top mounting Connection up to G1¼ Nominal flow rate up to 70 l/min

SilverLine S647, S660, S670. Diaphragm Valves, Plastic/Metal

SSV SL-022 Safety Shut-off Valve

VMH. www. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN200 EE

Tilting-disc Check Valves Short Body

3 Edition Product brochure GB AGA

SVL488 Stainless Steel Safety Valve for Clean Service Applications

Operating Instructions for Paddle Bellows Flow Monitor. Model: FPS-P...

with pneumatic actuator Pneumatic process valve, Y-pattern DN ARI-STEVI AS 350 Pneumatic actuator - with screwed sockets

Backflushing Filter AutoFilt RF3

ES 074 ES 094 Tank top mounting Connection up G1¼ Nominal flow rate up to 80 l/min

Suction Filter SF/SFM/SFF and Suction Filter Elements S/S..

Pilot Operated Pressure Reducing Valves with Stainless Steel Bodies

Seated valves (PN 16) VRG 2 2-way valve, external thread VRG 3 3-way valve, external thread

Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX

Introduction. Operation FTG 600

Transcription:

Gas and air filter GF/1: Rp 1/2 - Rp 2 GF/3: DN 40 GF/4: DN 50 - DN 100 GF: DN 125 - DN 200 11.02 Printed in Germany Edition 01.18 Nr. 215 203 1 8 Technical description Filter for interior gas lines as per DIN 3386 with high dust storage capacity. GF/1: Threaded connection as per ISO 7/1. GF/3, GF/4 and GF: Flange connection as per DIN EN 1092-1. Max. flow velocity: 20 m/s. Installation option for pressure measurement point for filter monitoring. pplication Type GF/1, GF/3, GF/4 and GF gas and air filter for protecting downstream fittings. Filter suitable for gases of families 1,2,3 and other neutral gaseous media. pprovals EC type testing certificate as per: EC-Gas ppliances Regulation EC-Pressure Equipment Directive pprovals in other important gas consuming countries.

Specifications - Threaded version Nominal diameter DN 15 DN 20 DN 25 DN 40 DN 50 Rp 1/2 Rp 3/4 Rp 1 Rp 1 1/2 Rp 2 as per ISO 7/1 Max. operating pressure Max. flow velocity GF 5.../1 GF 40.../1 20 m/s bar (50 kpa) bar (400 kpa) mbient temperature Pore width of filter element Measuring/ignition gas connection -15 C to +80 C 50 µm GF 5 /1: G 1/4 screw connection as per DIN ISO 228 upstream and downstream of filter element, on housing cover GF 40 /1: G 1/4 screw plugs as per DIN ISO 228 upstream and downstream of filter element, on housing cover Materials Housing Seals Random laid nonwoven fabric Filter holder aluminium cast NBR PP, PE POM Installation position ny, preferred position: with cap vertical Functional description Filter designed for installation in interior gas lines and compressed air lines to protect downstream fittings. Filter element made of random laid nonwoven polypropylene fabric and metal support frame with pore width of 50 µm. Dust, chips and rust as well as other physical gas-accompanying materials and fouling are retained using the random laid nonwoven fabric. If the dust storage capacity is exceeded or if there is an excessive pressure difference, the filter loses its protective function. Installation Refer to gas flow direction indicated by arrow on filter housing. Provide sufficient space for changing the filter element. If the filter cap is mounted in vertical position, it is easier to clean the filter housing. fter installation, perform leak test. void direct contact between hardening masonry, concrete walls, floors and filter. Change filter element - t least once a year - If pressure difference has increased by 100 % compared to new filter - When pressure difference exceeds 50 mbar Filter monitoring GF 5 /1: The G 1/4 screw plugs can be replaced by suitable screw connections. Connect an gas differential pressure switch to monitor the pressure difference. Gas filter with differential pressure switch G 1/4 screw connection only GF 5 /1 B Differential pressure switch for gas B + 2 8

Dimensions (mm) - Threaded version h Space requirement for changing filter element Type Order No. Max. operating pressure [bar] connection Rp Design Dimensions [mm] a b c d h Weight [kg] GF 505/1 066 191 Rp 1/2 120 90 35 55 125 0.7 GF 507/1 066 209 Rp 3/4 120 90 35 55 125 0.7 GF 510/1 066 217 Rp 1 160 105 54 51 159 1.1 GF 515/1 066 225 RP 1 1/2 160 105 54 51 159 1.1 GF 520/1 066 233 Rp 2 186 140 75 65 215 1.9 GF 4005/1 228 073 Rp 1/2 120 90 35 55 125 0.7 GF 4007/1 228 074 Rp 3/4 120 90 35 55 125 0.7 GF 4010/1 228 075 Rp 1 160 105 54 51 159 1.1 GF 4015/1 228 076 Rp 1 1/2 160 105 54 51 159 1.1 GF 4020/1 228 077 Rp 2 186 140 75 65 215 1.9 = screw connection = screw plug 3 8

Specifications - Flanged version Nominal flange size Max. operating pressure Max. flow velocity mbient temperature Pore width of filter element Measuring gas connection DN 40 DN 50 DN 65 DN 80 DN 100 DN 125 DN 150 DN 200 Flange connection as per DIN EN 1092-1 bar (400 kpa) 20 m/s -15 C to +80 C 50 µm G1/4 screw plugs as per DIN ISO 228 upstream and downstream of filter element, on left of housing Materials Housing Seals Random laid nonwoven fabric Support frame aluminium cast NBR PP Stainless steel Installation position Functional description Filter designed for installation in interior gas lines and compressed air lines to protect downstream fittings. Filter element made of random laid nonwoven polypropylene fabric and metal support frame with pore width of 50 µm. Dust, chips and rust as well as other physical gas-accompanying materials and fouling are retained by the random laid nonwoven fabric. If the dust storage capacity is exceeded or if there is an excessive pressure difference, the filter loses its protective function. GF.../3, GF.../4 gas filter section ny, preferred position: with cap vertical Installation Refer to gas flow direction indicated by arrow on filter housing. Provide sufficient space for changing the filter element. If the filter cap is mounted in vertical position, it is easier to clean the filter housing. fter installation, perform leak test. Important: void direct contact between hardening masonry, concrete walls, floors and filter. Filter monitor Change filter element - t least once a year - If pressure difference has increased by 100% compared to new filter - When pressure difference exceeds 50 mbar Filter monitoring The G 1/4 screw plugs can be replaced with suitable screw connections. This permits the connection of an gas differential pressure switch to monitor pressure difference. 1 O ring 2 Cover 3 Housing 4 Filter element B Measurement connection Differential pressure switch for gas 1 2 3 4 + B 4 8

Dimensions (mm) - Flanged version h c d b h Space requirement for changing filter element Type Order No. Max. operating pressure [bar] DN connection Dimensions [mm] a b c d h Weight [kg] GF 40040/3 222 637 DN 40 132 195 49 47 96 2.8 GF 40050/4 256 408 DN 50 170 220 76 60 119 4.1 GF 40065/4 256 409 DN 65 194 252 95 93 188 6.0 GF 40080/4 256 410 DN 80 236 300 103 107 206 8.3 GF 40100/4 256 411 DN 100 282 352 119 111 229 12.3 GF 40125 218 162 DN 125 281 360 182 183 365 19.5 GF 40150 218 163 DN 150 281 385 257 259 516 25.5 GF 40200 218 164 DN 200 388 455 236 239 475 40.0 5 8

Volumetric flow/pressure drop characteristic Pressure loss p [mbar] for natural gas (dv = 0,64) Gas flow rate [m 3 /h] (standard flow rate) Operating flow rate [m 3 /h] Pressure loss p [mbar] for air (dv = 1) Inlet pressure p e [bar] 6 8

Diagram 1 - Determining the nominal diameter - Conversion of the flow rate from standard flow rate to operating flow rate. Diagram 2 - Determining the pressure loss ( p). Procedure Determining the filter size 1.1 Define the flow rate as a standard flow rate on the lower scale. 1.2 Draw a parallel reference line along the diagonal dashed line up to the actual inlet pressure. 1.3 You will find region for minimum filter size vertically above this point of intersection. You can read the corresponding flow rate from the scale above. Example Determining the filter size 1.1 Flow rate (standard flow rate) 2,000 m 3 /h 1.2 Inlet pressure 4 bar 1.3 Determining the filter size: min. DN 100, Determining the flow rate: 400 m 3 /h Example Procedure Determining the pressure loss 2.1 Define the flow rate as a standard flow rate on the lower scale. 2.2 Draw a parallel reference line along the diagonal solid line up to the actual inlet pressure. 2.3 Go from this point of intersection vertically upwards to diagram 2. The pressure loss for gas and air can be read at the point of intersection with the characteristic curve for the previously determined filter size. The pressure loss for other gases can be estimated from the value valid for air by multiplying this value with the density ratio. Determining the pressure loss 2.1 Flow rate (standard flow rate) 2,000 m 3 /h 2.2 Inlet pressure 4 bar 2.3 Determining the pressure loss for gas: p = 15 mbar Determining the pressure loss for air: p = 23 mbar ll specified values refer to filter mats in new condition. Pressure loss p [mbar] for air (dv = 1) 2.3 Pressure loss p [mbar] for natural gas (dv = 0,64) Operating flow rate [m 3 /h] Inlet pressure p e [bar] 1.3 1.2 2.2 1.1/2.1 Gas flow rate [m 3 /h] (standard flow rate) 7 8

Gas and air filter GF/1: Rp 1/2 - Rp 2 GF/3: DN 40 GF/4: DN 50 - DN 100 GF: DN 125 - DN 200 We reserve the right to make any changes in the interest of technical progress. Head Offices and Factory Karl Dungs GmbH & Co. KG Karl-Dungs-Platz 1 D-73660 Urbach, Germany Telephone +49 (0)7181-804-0 Telefax +49 (0)7181-804-166 Postal address Karl Dungs GmbH & Co. KG Postfach 12 29 D-73602 Schorndorf, Germany e-mail info@dungs.com Internet www.dungs.com 8 8