VIS IRREVERSIBLE ELECTROMECHANICAL MOTOR FOR SECTIONAL DOORS. Rev /2011 RT

Similar documents
OP3-OP5 LINEAR ELECTROMECHANICAL OPERATOR FOR SWING GATES. Page 1 INSTRUCTIONS AND WARNINGS FOR INSTALLATION, USE AND MAINTENANCE

E R A I GATE AUTOMATION DIVISION

MEKO OPENER FOR RACK-DRIVEN SLIDING MOTOR

Installation manual. English. mystrike OPENER FOR RACK-DRIVEN SLIDING MOTOR

BISON 20 OM BISON 25 OTI

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

L /2012 rev 0 BISON 45 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

L /2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

ARACHNE 230V 24V- 12V

SARGON S - M - L. All rights reserved INSTALLATION MANUAL

Operating Instructions for Roll-Up Door Operators / MDF

L /2013 rev 0 BISON 35 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

TITANO 400V SLIDING GATE OPENER

BULL 424 ESA BULL 624 ESA

Istruzioni, instructions. Motoriduttore a braccio snodato per cancelli battenti Gear motor with articulated arm for swing gates ALPHEO

F ERNI K I T THE FERNI-S KIT CONSISTS OF:

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

Corso Principi di Piemonte, 65/ RACCONIGI (CN) ITALY tel fax

MOUNTING AND CONNECTING INSTRUCTIONS 1. GATE ARRANGEMENT ENGLISH

CICLÓN ATTUATORE ELETTROMECCANICO IRREVERSIBILE A BRACCIO SNODATO PER CANCELLI A BATTENTE

FROG KIT. Installation Instructions for a Pair of gates... TECHNICAL HELPLINE THE FROG-P KIT CONSISTS OF:

FITTING AND CONNECTION INSTRUCTIONS

Installation Manual. Swing Gate System. Leading the way...

Automatic concealed bollards 275 H600 and 275 H800 with pit

Contents. EC DECLARATION OF CONFORMITY FOR MACHINES... p. 10. WARNINGS FOR THE INSTALLER... p. 10

BULL 5M - BULL 5M.S BULL 8M - BULL 8 M.S BULL 8 OM - BULL 8 OM.S

Automations for garage doors and rolling shutters

CHECKING AND MAINTENANCE:

INSTALLATION MANUAL ACE. Gearmotor for swing gates 01_17

SKC400U SLIDING GATE OPENER OWNER S MANUAL

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

WEL. Manuale di installazione e manutenzione per automazioni per porte battenti. Installation and maintenance. for swing doors.

Ditec DOD Industrial sectional door automations

Automatic concealed bollards 275 H600 and 275 H800 Control station

OMATION FOR SLIDING GATES LINESTAR INSTALLATION MANUAL

EC DECLARATION OF CONFORMITY

contents OPERATOR Maintenance SHAFT-120 Installation and Operating Manual DoorHan, 2012

IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS

Ditec LUXO Swing gates automation (Original instruction)

EL5600 Series Electric Linear Actuators Installation and Maintenance Instructions

INSTALLATION MANUAL FOR SWING SHUTTERS KAF212. FACE S.r.l. Viale delle Industrie, Dosson di Casier Treviso Italy

Safety switches for hinged doors

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2.

OPERATOR SHAFT-120. Installation and Operating Manual CONTENTS GENERAL INFORMATION SAFETY INSTRUCTIONS OPERATOR UNIT OPERATOR INSTALLATION

PW150/PW200 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR

SLIDE & OL USER'S AND INSTALLER'S MANUAL V1.0 REV. 06/2017

INSTALLATION MANUAL ENGLISH ALPHA 200 ALPHA 330. L C (stroke) 960 mm 1160 mm

For sectional and up-and-over doors. 118 Spinbus 122 SpinbusKit 20/21/ SpinbusKit 23. For up-and-over and articulated doors.

AUTOMATION SYSTEM FOR SWING GATES FROG SERIES INSTALLATION MANUAL SUPERFROG

INSTRUCTIONS FOR INSTALLATION

AEL6 Series Smart Electric Actuators for ½" to 4" Control Valves

M OTO R. The electric motor. DC - direct current voltage.

AIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO:

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC)

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

TECHNICAL DATA HYDRAULIC UNIT

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return, 24 Vac Floating Control, Rotary

MOTOR. The electric motor. DC - direct current voltage.

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) WARNINGS FOR THE INSTALLER

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

INSPECTIONS AND MAINTENANCE

GROUND GROUND - ( ) Interrati elettromeccanici ISTRUZIONI PER L INSTALLAZIONE. Electromechanical underground INSTRUCTIONS FOR INSTALLATIONS

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional -

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

Recommended control units: Mindy A824/110. Aluminium Nice release: user-friendly, effortless, sturdy. Flashing light. Digital or key switches

Sectional and Tilting Door Opener

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return Rotary 24 Vac 3-position Control

Jet. Gear motor for swing gates MADE IN ITALY INSTRUCTION MANUAL

BIG Series. D_MNL0BIG Rev.18. IT - Istruzioni originali

FORCE SPD 800/1500/2000

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

MOOVY AUTOMATIONS FOR SLIDING GATES (230/110/24V)

CE DECLARATION OF MACHINE CONFORMITY

SHUTTER D GARAGE & ROLLER SHUTTER

Oil-hydraulic operator for swinging gates

INSTALLATION MANUAL GB

SIZING OF SOLAR GENERATOR

IP2160 EN. Ditec NEOS Sliding Gates. Technical Manual. (Original instructions)

Teknospeed Inverter Diagrams and Drawings

SPINBUS UTILISATION LIMITS DIMENSIONS CODE DESCRIPTION PACK/PALLET SPIN N. COMPLETE WITH GUIDE IN THREE 1 m-sections SPIN40

A44 W0...W2: Motorised actuator

Ditec PWR50H/HV/HR Automation for swing gates

SWING GATE OPENERS 24V DC GEAR MOTOR

Installation Manual. RW240/400/600 Motor Gearbox

Series A Electric Linear Actuators

EMC Compatible enclosure assembly

OPERATOR FOR GARAGE DOORS FA00047-EN INSTALLATION AND OPERATION V6000. English

Flowrite EA 599 Series SKD Electronic Valve Actuator 24 Vac Proportional Control

UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack

IGEA LB INSTALLATION AND USER'S MANUAL. MONTAGE- und BEDIENUNGSANLEITUNG INSTRUÇÕES DE USO E DE INSTALAÇÃO

Sectional And Tilting Door Opener

Instruction Manual for the. E-SL 450 Series

SUBMERSIBLE WATER PUMP

Single foot switches PX and PA series

Technical Instructions Flowrite 599 Series SKD6xU Electronic Valve Actuators 24 Vac Proportional Control Description Features Application

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION

Index. 4. DESCRIPTION... p PRELIMINARY CHECKS... p ASSEMBLY... p. 6

INSTALLATION MANUAL SPECTRUM BRAKE CONTROL

Electromechanical gear motor for sliding gates ACHILLES

Transcription:

VIS GB IRREVERSIBLE ELECTROMECHANICAL MOTOR FOR SECTIONAL DOORS. Rev. 01-07/2011 RT

TECHNICAL DATA LIFE home integration reserves the right to change the specifications at any time without notice, maintaining the intended use and functionality. VIS is a family of motors, electromechanical irreversible, for the automation of sectional doors balanced and sliding folding-type industrial and direct-drive shaft spring is chain driven. The range is 1 model: VIS without control board VIS Electromechanical irreversible gear motor for sectional doors and and sliding folding encoder and with or without central control board VIS Plugged V 230 Vac 50 Hz power supply V 230 Vac 50 Hz Max Power W 450 Current absorption line (230V) A 3 motor torque Nm 45 lubrication Type grease electromechanical switches SI Encoder SI Speed rpm 20 work cycle % 35 Rated working time min. 60 operating temperature C -20 +70 Degree of protection IP 54 Motor insulation class F Weight 15 Kg Central Unit GE VIS R DL 2

1 1 2 RG58-50ohm AERIAL 1 2 6 7 8 9 10 11 12 N.C. N.O. N.O. N.O. N.C. N.C. STEP SENSITIVE EDGE PHOTO 2 6 7 NC NO COM 14 15 16 INDICATOR LIGHT 24 Vac 3W max / PHOTO TEST OUTPUT 24 Vac 200 ma max 10 3 RX TX 0V 12V 24V COM NO NC 0V 12V 24V BLACK 230aV BROWN BLUE 20 21 22 23 24 25 L1 CAPACITOR MOTOR1 OPEN COMMON MOTOR1 MOTOR1 CLOSE 230 Vac 25W max FLASHING 230 Vac 40W max COUTESY LYGHT 6 7 8 9 10 OPEN CLOSE L2 L1 PARTIAL OPENING 230 Vac 6 12 15 16 4 6 12 15 14 16 5 14 16 PHOTO TEST RX TX 0V 12V 24V COM NO NC 0V 12V 24V 24 Vac 3w max 6 34 ENCODER B 33 ENCODER A 32 COMMON 31 LIMIT SWITCH CLOSE 30 LIMITSWITCH OPEN 6 COMUN COMMAD 7 STOP 22 MOTOR CLOSE 21 COMMUN MOTOR 20 MOTOR OPEN 7 24 230 Vac 40W max 25 23 25

1 CONNECTIONS AND LINKS The motor must only be connected to its central by Life GEVISRDL. All operations of these cables and connections should be disconnected from the power supply, if the disconnect device a sign: "WARNING MAINTENANCE IN PROGRESS". internal wiring electromechanical linear actuator that have been made should definitely be changed. They do, however, present the following warnings:the electrical supply must be routed and connected by or a professional installer. The power line must have adequate protection earth faults. Must be provided in the network of power disconnection device through air contact opening of not less than 3.5 mm, complete disconnection from supply. 1.1 Introduction of electrical wiring in the motor a) For access to terminals is necessary to remove the cap (1) covering b) Attach the cables to the base with the mounting of cable ties (2). C 1 2 1,2 Electrical Connections The installer should perform the power connections to 230 Vac 50 Hz and the various devices provided for automation. The connections between the central, motor, encoder and transformers are already performed by the manufacturer. ATTENTION: for security is indispensable to connect the set- motor ground. Crimp the wire yellow-green cap instead of the power cord on hood higher at the point marked by the symbol of earth as shown in Fig. (7.1 4

2 INSTALLATION 2.1 Preliminary checks and limits operating Before installing you must do the following preliminary checks: The door structure is adequately strong, the hinges are efficient and that there is no friction between fixed and mobile parts The path of power cables is carried out in accordance with control and safety there is a mechanical setback in the opening Correct balance of the door. The table has an indicative value, as are many factors that determine The limits of application VIS SECTIONAL DOOR SLIDING DOOR HIGHT MAX 6,5 m WIDTH MAX 8 m WEIGHT MAX 1000 kg 2.2 MOTOR INSTALLATION COMPONENTS 2.3 MOTOR ASSEMBLY 1. LIVE SOCKET The VIS can be connected motor direct drive shaft door springs D = 254 mm = 1 " Unlock the motor manually by turning the release knob counter-clockwise, position (A) to position (B). LOCK UNLOCK

2.3.1 DIRECT DRIVE Slide the bushing (G) on the tree (D) Insert the motor (C) onto DOOR SPRING (D) moving the gate so as to match the cavity tree with that of the MAST MOTOR CABLE gearmotor. Insert TAB (E) between the two cavities. Entries with the hollow shaft motor (F) C F E D D I C H G D Tighten down with the screw (H). Assemble the brackets (I) and secure them to motor (C) (avoiding the lock). E C 2.3.2 CHAIN TRANSMISSION the motor can be connected with VIS TRANSMISSION CHAIN. Installation of sectional garage doors with a height greater to 5.5 m, for this type of application must use the accessory to complete VISCA Tighten down with the screw (H). Assemble the brackets (I) and secure them to motor (C) (avoiding lock Unlock the motor manually by turning the release knob counter-clockwise, position (A) to position (B)...

Secure the fixing bracket (L) to the motor (C) provvisoriamente.con screws endowment Insert TAB (M) in tree cavity DOOR SPRINGS (N) introduce CROWN GEAR (H) TREE DOOR SPRINGS Z40 at the TAB and fix everything with the screw (P). Then insert the TAB (Q) in the cavity of the tree with PINION Z26 Put then the 'MOTOR SHAFT WITH PINION into the hollow (R) and secure it with screws and washer (D). Join the two ends of the chain (T) with the joint and insert on the crown (R) Z40 gear leaving hanging, release the motor and secure it to the wall, making sure that the two crowns sprockets are aligned perpendicular. (see drawing) 2 L O M P O N C O Q T R O R T S R R 1 2 3

3 UNLOCK MOTOR VISMV Manual unlock release chain. fix the wheel (A) gear with the screw (B) after fixing The UNLOCK CHAIN (C) VIS motor to tighten the 4 screws (D) a bit 'at a time B A Please note that CONTACT N.C. RELEASE OF CONNECTED IN SERIES TO Go ANY OTHER CONTROL STOP. CAUTION: To release the operator to pull down first and then move the chain to the right or left. D C E F GREEN RED VISBLK: Manual unlock by pendulum (E) Green (F) red Replace the release knob with that found inside the kit.. 8

5RI3060000 5RI3010000 5RI3070000 5RI3040000 OPEN CLOSE 5RI3030000 5RI3020000 5RI3080000 5RI3050000 5RI3000000

Declaration of conformity under Directive 98/37/EC, appendix II, part B (Manufacturer s Declaration of CE Conformity) LIFE Home Integration Via S.Pertini 3/5 31014 COLLE UMBERTO (TV) declares that the following product: VIS MOTOR satisfies the essential requisites established in the following directives: Low voltage directive 98/37/EEC and subsequent amendments, Electromagnetic compatibility directive 89/336/EEC and subsequent amendments, Radio and telecommunications equipment directive 1999/5/EC and subsequent amendments. and satisfies the following standards: EN 12445:2000 Industrial, commercial and garage doors and gates Safety in the usage of motorised doors testing methods EN 12453: Industrial, commercial and garage doors and gates Safety in the usage of motorised doors Requisites EN 60204-1:1997 Machinery safety Electric equipment of the machine Part 1: general rules. EN 60950 Information technology equipment - Safety - Part 1: General requisites ETSI EN 301489-3:2001 Electromagnetic compatibility for radio equipment and appliances. EN 300220-3:2000 Radio equipment and systems short band devices Technical characteristics and testing methods for radio apparatus with a frequency of 25 to 1000 MHz and powers of up to 500mW. The Manufacturer also declares that it is not permitted for the abovementioned components to be used until such time as the system in which they are incorporated is declared conform to directive 98/37/EC. COLLE UMBERTO Name of Signor: MICHELE RUI Position: PRESIDENT Signature: 0

Address: Via Sandro Pertini,3/5 31014 COLLE UMBERTO (TV) Italia Telephone: + 39 0438 388592 Telefax: + 39 0438 388593 http www.homelife.it e-mail: info@homelife.it