KGEB Exhaust valve. Specifications. Quick Selection. Product code example Exhaust valve KGEB-100-C Mounting ring KGEZ-01

Similar documents
CTVK Supply air diffuser

STI Supply air valve. Specifications. Quick Selection. Product code example Supply air valve STI-160-C

KTS Supply air valve. Specifications. Quick Selection (50 Pa) Product code example Supply air valve KTS-100-C

KSOF Fire damper valve

KTI Supply air valve. Product Facts. Product code example. Quick Selection

Exhaust air diffuser HPKH + Plenum box ATTS

Nozzle diffuser DYRH / Supply air unit DYRB (=DYRH+ATTD)

Supply air unit DYBA. Specifications. Connbox. Quick Selection DYBA, without slot, 1:3 plenum box ATTC (50 Pa)

Nozzle air diffuser DYSB

Supply air diffusers RPPH and ROPH / Supply air units RPPA/ROPA (=RPPH/ROPH+ATTD)

Conical diffuser KHAA TECHNICAL DATA

Supply air diffusers RHKH and RHOH / Supply air units RHKB/RHOB (=RHKH/RHOH+ATTD)

KSOM Control exhaust valve

Wall diffuser SVQC / Supply air unit SVQC + ATVA TECHNICAL DATA

EAGLE Wall. Wall air diffusers with discs for supply air and flush mounting QUICK FACTS

Wall air diffusers with discs for supply air and flush mounting. Quick guide COLIBRI WALL

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

EXCa. Exhaust register

SRY. Ceiling mounted linear disc diffuser for supply air QUICK FACTS

OPTIVENT Housing HVSA, HVSL

ADAPTTM. Sphere. Active communicative, supply air diffuser for the WISE system. Quick Selection

PELICANTM. Wall. Rectangular perforated wall air diffusers for supply air. Quick guide

ADAPTTM. Extract. Extract air diffuser for the WISE system. Quick Selection

DATASHEET PRODUCT CODE EXAMPLE:

ADAPTTM. Free. Active communicative, supply air diffuser for the WISE system, ADAPT F

CornerAir. CornerAir. Active chilled beam

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

TUBUS TUBUS. Key figures. Function Wall-mounted supply air diffusers

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS

Fire damper ETPR. Specifications. Product code example Fire damper ETPR

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

Krantz. Floor displacement outlet Q-B-DN 200. Air distribution systems

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

External grilles USAV, USVN, USSV and SVN TECHNICAL DATA

Plenum boxes. About Lindab. Comfort and Design. Product overview / symbols. Theory. Ceiling diffusers. Ceiling diffusers - visible.

CRP. Commissioning damper, Ductwork Leakage Class 0

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE

CRP. Commissioning damper, Ductwork Leakage Class 0 QUICK FACTS. Perforated damper blade for better damper characteristic

SERENO

Fire dampers ETCE and ETCS TECHNICAL DATA

Regulation and shut-off damper SPB and SPC

Broad multiplex outlet BF-V...

OptimAir NF. Active Chilled Beam OptimAir NF. Nov

Ventiduct nozzle ducts

ACTIVENT System. Specifications. Product code example ACTA

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

series RVV Variable flow rate controllers

Marine Catalogue 2014

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

ROOF FAN ROOFMASTER STEC

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Exhaust air diffuser EYMA-2 and air intake device DYMA-1

REK, LEK, ROK and LOK

CONSTANTFLOW Volume Flow Controllers

IQ STAR NOVA II CHILLED BEAM» TECHNICAL DATA

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

J L I e x h a u s t h o o d

Room product for Swegon s WISE System for demand-controlled ventilation

CHILLED BEAM IQ STAR WEGA II

BLBd

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

BRC

Adriatic for individually suspended installation Exposed active climate beam with cooling, heating and ventilation

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

Ventiduct nozzle ducts

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

DIR. VARIZON Displacement unit with adjustable spread pattern. Quick guide

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

ROOFMASTER STEF-HT ROOF FAN

REK, LEK, ROK AND LOK

ADRIATIC VF. Active climate beam with cooling, heating and ventilation QUICK FACTS

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

1/8/EN/6. Floor Diffusers. Type FB. in aluminium and plastic

ULA - Valve. Halton ULA. Valve

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

CADENZA. Sound attenuator with tapered acoustic baffles for rectangular ducts QUICK FACTS

NTK floor twist outlet DB-N-DN 215

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

ACCESSORIES FOR DUCT FANS

Smoke damper EKO-SRB1

DCV-CF DCV-CF. DCV-CF Pressure control with airflow measuring CFL Version B03. Pressure controlwith airflow measuring. Product description

Kitchen exhaust fan GLEB

ROOFMASTER STEF-ATEX ROOF FAN

Combustion gas damper EKO-SRB

Pressure control damper ERPA

Ceiling swirl diffusers

Accessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound

Plenum box ATTD TECHNICAL DATA

TBV - Terminal Unit. Halton TBV. Terminal Unit

Zest Iris Duct Dampers

Duct Nozzle Diffuser. L e

Catalog Swirl diffuser DAL 358

for suspended installation. Active climate beam with cooling, heating and ventilation

Medium Pressure Centrifugal Fans

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

Transcription:

KGEB Exhaust valve The KGEB exhaust valve is suitable for use in mechanical ventilation systems. The valve can be wall mounted or ceiling mounted and its air flow is simple to adjust. The KGEB has a low noise level, even if the pressure drop is high, and it has good natural sound attenuation. Quick Selection Size Connection Air flow range l/s at sound level alternative 25 db 30 db 35 db KGEB-100-C T-piece 16 19 23 Mounting ring 20 24 27 Angle duct 14 16 19 KGEB-125-C T-piece 22 25 28 Mounting ring 29 34 38 Angle duct 16 20 23 KGEB-160-C T-piece 42 50 58 Mounting ring 47 55 64 Specifications CleanVent coating as standard Low noise level, even if the pressure drop is high Good natural sound attenuation Both for new installation and renovation Manufactured of steel Product code example Exhaust valve KGEB-100-C Mounting ring KGEZ-01 1 (7) Specifications are subject of alteration without further notice.

Air flow, pressure drop, sound level Size 100 with T-piece Size 125 with T-piece Size 100 with mounting ring Size 125 with mounting ring Size 100 with angle duct Size 125 with angle duct 2 (7) Specifications are subject of alteration without further notice.

Air flow, pressure drop, sound level Size 160 with T-piece Acoustical data Sound power level KGEB Correction of sound level in db at octave bands, middle frequency, Hz 100 10 6 5 1-2 -4-7 -12 125 17 2 3-1 -1-4 -8-12 160 18 4 3 0 1-4 -12-14 Sound attenuation Size 160 with mounting ring KGEB-100-C Connection Sound attenuation in db at octave bands, mean frequency, Hz fitting KGEZ 01-100 25 22 21 20 14 18 9 10 05-100 25 22 21 20 14 18 9 10 43-100 30 27 23 17 16 19 12 13 KGEB-125-C Connection Sound attenuation in db at octave bands, mean frequency, Hz fitting KGEZ 01-125 24 20 17 15 11 12 7 7 05-125 24 20 17 15 11 12 7 7 43-125 29 25 19 12 13 13 10 10 KGEB-160-C Connection Sound attenuation in db at octave bands, mean frequency, Hz fitting KGEZ 01-160 22 18 16 12 14 10 9 8 05-160 22 18 16 12 14 10 9 8 3 (7) Specifications are subject of alteration without further notice.

Installation Adjustment Valve KGEB connected to a mounting ring b b Valve KGEB connected to an angle duct 100 b -11-9 -6 0 +6 +9 k-factor 0,39 0,56 0,82 1,36 1,9 2,2 125 b -22-18 -12-6 0 +6 k-factor 0,88 1,3 1,8 2,4 2,9 3,4 160 b -24-18 -12-6 0 +6 k-factor 1,8 2,5 3,1 3,9 * 4,6 * 5,4 * * Applicable for KGEB produced after 01.01.2003 4 (7) Specifications are subject of alteration without further notice.

Dimensions and weight Mounting frame KGEZ-12 Exhaust valve KGEB ØA B *) Holes (Ø4 mm) 15 mm from the edges. Size A B Weight [mm] [mm] [kg] 100 130 45 0.3 125 155 56 0.4 160 190 65 0.6 Mounting ring KGEZ-01, insertion conn. / Mounting ring KGEZ-05, fit-on conn. 15 Size D Weight [mm] [kg] 100 100 0.20 125 125 0.20 Used to replace earlier types of valves by KGEB-100 and KGEB-125 respectively. Mounting frame KGEZ-20 Hole Size A D 1 D 2 size Ø Weight [mm] [mm] [mm] [mm] [kg] 100 123 99.3 100 110 0.10 125 149 124.3 125 135 0.10 160 185 159.3 160 170 0.16 1 = Seal 2 = Spring Weight 0.3 kg. Used when old KGD valves are replaced with KGEB-100 or KGFC-1-010. Angle duct KGEZ-43 EXT. ØD2 B C ØD 1 A Size A B C D1 D2 Weight [mm] [mm] [mm] [mm] [mm] [kg] 100-080 120 39 148 125 79.3 0.4 100-100 140 39 98 125 99.3 0.4 125-100 146 45 120 140 99.3 0.5 125-080 115 36 162 131 79.3 0.4 5 (7) Specifications are subject of alteration without further notice.

General Application The KGEB exhaust valve is suitable for use in all type of air treatment installation. The valve can be wall or ceiling mounted and the air flow is easy to adjust. KGEB has a low noise level, even if the pressure drop is high, and it has good natural sound attenuation. The valve has accessories adapted to different kinds of installations. Exhaust valves in sizes 125 and 160 fit renovation constructions in older KGEZ branches in equivalent sizes. Material and surface finish The valve is made of hot galvanized steel sheet. It is powder coated for a high surface finish and good impact and scratch resistance. Standard colour is white (RAL 9010). CleanVent coating as standard. Instructions Instructions for installation, adjustment and maintenance are described in detail in our technical instructions, also available on the Internet at: www.flaktgroup.com. Technical data and dimensioning For complete dimensioning details, please see FläktGroup product selection program. Contact our nearest sales office for further information. Packing Delivery in cartons containing 10 pc. Descriptive text KGEB exhaust valve manufactured by FläktGroup in size 100, with fit-on type mounting ring/insertion type mounting ring/angle duct. Product code Exhaust valve 100, 125, 160 Surface finish (b) C = Standard CleanVent coating E = Special colour KGEB-aaa-b 6 (7) Specifications are subject of alteration without further notice.

Accessories and spare parts Accessories Mounting ring, insertion connection Mounting ring, fit-on connection 100, 125, 160 Mounting frame 100, 125 Mounting frame (for old KGD frames) KGEZ-01-aaa KGEZ-05-aaa KGEZ-12-aaa KGEZ-20 Angle duct KGEZ-43-aaa-bbb Size (aaa-bbb) Connection diameter in mm to valve - to duct 100-080, 100-100, 125-080, 125-100 Spare parts Seal Spring 100, 125, 160 COGZ-aaa-4 COSZ-aaa-1 7 (7) Specifications are subject of alteration without further notice.