GEWAS 181 A. Alarm- and protection device Leak-water detector

Similar documents
Installation manual portable distributors

Schmidt Mess- und Regeltechnik

Operation Manual for Torque Sensors

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016

Installation manual wall-mounted distributor

Operating instructions Accu Jet

KSZ 10B Current Probe Calibrator. Instruction Manual

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Instruction Manual for Microliter Centrifuge Z 233 M-2

Operating Instructions

KSZ 100B Current Probe Calibrator. Instruction Manual

INTRODUCTION GENERAL GUIDELINES ATTACHING THE DRIVE PARTS

Instruction manual Electric glass door lock Touch-to-open

80 Series V Digital Multimeter Safety Information

Operating Instructions for Elevator Buffers type LP

Commissioning Manual AC Servo Actuator LynxDrive SIEMENS SIMODRIVE

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

TIDALFLUX 2300 F Quick Start

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

HD UNIT INSTALLATION & SERVICE BOOKLET 3-7

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

The Efficient Solution for Pipetting up to 100 ml at once! USER'S GUIDE

User Manual Rittal PMC UPS 6kVA

CONTACTS EGR VALVE TESTER 66248

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions

A Assembly Instructions Trampoline Piccolo Art with Special Installation Frame

i3000s/i2000 Flex AC Current Probe

GENUINE ILLUMINATED SCUFF PLATE

1200W INVERTER GENERATOR

MS-4200/4201/4202/4202L USER MANUAL

WK 120QMM-6M/Z EL 120QMM-6M/M12

315W CMH COMPLETE GROW LIGHT SYSTEM [ V] USER MANUAL

Parker Hannifin Filtration Group Racor Division DUAL FBO OPERATION AND MAINTENANCE INSTRUCTIONS SPARE PARTS

Ultrasonic Leak Detector and Seal Control Device SONAPHONE R

362 Clamp Meter. Users Manual

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

SensoLyt 700 SensoLyt 700 SW

Operating instructions

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

60V RECHARGEABLE LITHIUM-ION BATTERY

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation

MX2040, DYNAMIC SIGNAL CHECKER Instruction Manual

3-Year Limited Warranty. See the Users Manual for the full warranty.

Starting up hydraulic systems

PURE SINE WAVE DC TO AC POWER INVERTER

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Liko M220 / Liko M230

SensoStar C. Installation and Operating Instructions Heat Meter Calculator Heat/Cooling Meter Calculator Cooling Meter Calculator

Differential Pressure Transmitter

16 37 TM INTEGRATED RADIO CONTROL INSTRUCTION MANUAL

Operatingmanual. Mehrsprachige Anleitung unter Multilingual manuals at. pro BENNING TRITEST BENNING BENNING BENNING.

OWNER S MANUAL TOLL-FREE HELPLINE: (Monday - Friday / 8am - 4:30pm CST)

Anleitung_BG_PW_48_SPK1:_ :33 Uhr Seite 1. Operating Instructions Petrol Water Pump. Art.-Nr.: I.-Nr.

TRAIL-Control - Manufacturer -

OPERATOR S MANUAL SINGLE PORT UNIVERSAL CAR CHARGER

233 True-rms Remote Display Digital Multimeter Safety Information

Type 6213 EV, 6281 EV

Operator s manual Manuel d utilisation Manual de instrucciones. BLi520x BLi940x

2-Year Limited Warranty. See the Users Manual for the full warranty.

Operating instructions Binary level sensor LMT /00 06/2011

Gavita HortiStar 1000 DE EU/US

Operating Instructions BNT-40 Automatic Rebar Tying Machine

LCD video-goggle with 5,8 GHz diversity receiver HIVR 101

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

HST-BL-2830MS & HST-BL-2830MS-USA

OPERATING INSTRUCTIONS

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

User Guide for Viridian EV Charging Stations


AG-HA-2500N GASOLINE GENERATOR

Instruction Manual. Coating Thickness Gauge. Optionally with Memory

GEIGER-GJ5610v1 with mechanical end stop For Venetian blinds and exterior blinds for 100 V power supply

Operation Manual for. HC16 Three-Axis Helmholtz Coil

4 - SETTING UP THE MACROMAN CHARGING POSITION 4 Wall mounted 4 Workbench set-up 4

Specification Approval Sheet

Ball valve for pipeline systems

SPSR-115/230. Self-Powered Sensor

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

FL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions.

Continuous level sensor NSK

HYDRAULIC QUICK HITCH

Sectional and Tilting Door Opener

Checkup. Make. Signature. Date. Company Stamp: com

A Assembly Instructions Trampoline 2012 Art

TESTER SET SOCKET & VOLTAGE

Ti200, Ti300, Ti400, Ti450, Ti480 Thermal Imagers

original operating manual Operating manual Translation of the Item-No.: ,

A company of ThyssenKrupp Elevator. ThyssenKrupp Aufzugswerke. Operating Manual. Oil buffer

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

21-KGR21 BRUSH GRAPPLE CAREFULLY READ THE OPERATING INSTRUCTIONS BEFORE USING THE PRODUCT! OPERATING INSTRUCTIONS TRANSLATED FROM THE ORIGINAL

Module B Module C FOR THE WEATHER CONTROLLER MULTI-MIX INSTALLATION MANUAL REVISION: 1.0_EN

Instruction manual. Liftkar HD Uni Liftkar HD Fold Liftkar HD Dolly Liftkar HD Fold Dolly. Issued: 10/2010 subject to updates.

WOOOM INSTRUCTION MANUAL

Operating Instructions

Translation of the Original operating instructions Lifting device Z 70 /...

Flow Fittings. for Electrochemical Sensors. B Operating Manual /

Advanced Calibration Designs, Inc. Release II

User Manual TABLE MAGNIFIER TL-70. User-friendly Manual ID: #05007

Constant Running Hydraulic Pump Installation Guide. Document Number: Date: March 2006

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Transcription:

S07.0.1X.6C-04 Alarm- and protection device Leak-water detector Operating Manual GEWAS 181 A WEEE-Reg.-Nr. DE93889386 GHM Messtechnik GmbH Standort Greisinger Hans-Sachs-Str. 26 D-93128 Regenstauf +49 (0) 9402 / 9383-0 +49 (0) 9402 / 9383-33 info@greisinger.de

S07.0.1X.6C-04 Operating Manual GEWAS 181 A page 2 of 6 Index 1 INTENDED USE... 2 2 GENERAL NOTE... 2 3 SCOPE OF SUPPLY... 2 4 SAFETY... 2 4.1 SAFETY SIGNS AND SYMBOLS... 2 4.2 SAFETY REQUIREMENTS... 3 5 COMPONENTS... 3 6 INSTALLATION AND COMMISSIONING... 4 6.1 INSTALLATION OF THE SOLENOID VALVE... 4 6.2 INSTALLATION OF THE CONTROL UNIT AND THE WATER SENSOR... 4 7 FUNCTION... 4 8 OPERATING ELEMENTS... 4 9 WHAT TO DO IN CASE OF ALARM... 5 10 OPERATING AND MAINTENANCE ADVICES... 5 11 SPECIFICATION... 6 12 DISPOSAL INSTRUCTIONS... 6 1 Intended use The GEWAS 181 A with solenoid valve of brass is an alarm and protection device. The solenoid valve is intended the direct installation in tubes. If a water film is detected at the sensor, the valve will be closed and the unit warns with an intense signal tone. Application range: Alarm and protection device for prevention of water damage Observation of devices and machines with water-connection 2 General Note Read this document carefully and get used to the operation of the device before you use it. Keep this document within easy reach near the device for consulting in case of doubt. 3 Scope of supply 1 x control unit GEWAS 181A with switchable socket 1 x water sensor GWF-1S 1 x solenoid valve GMV ½" H (rigid attached on device) 1 x sieve sealing-ring 4 Safety 4.1 Safety signs and symbols Warnings are labelled in this document with the followings signs: Caution! This symbol warns of imminent danger, death, serious injuries and significant damage to property at non-observance. Note! This symbol point out processes which can indirectly influence operation or provoke unforeseen reactions at non-observance.

S07.0.1X.6C-04 Operating Manual GEWAS 181 A page 3 of 6 4.2 Safety requirements This device has been designed and tested in accordance with the safety regulations for electronic devices. However, its trouble-free operation and reliability cannot be guaranteed unless the standard safety measures and special safety advises given in this manual will be adhered to when using the device. 1. Trouble-free operation and reliability of the device can only be guaranteed if the device is not subjected to any other climatic conditions than those stated under "specification". 2. Make sure to observe the standard regulations and safety instructions for electric, heavy and weak current plants, in particular the national safety regulations (e.g. VDE0100). 3. When there is a risk whatsoever involved in running it, the device has to be switched off immediately and to be marked accordingly to avoid re-starting it. Operator safety may be a risk when the device: - has visible damages - is not working as specified - has been stored under unsuitable conditions for a longer time. In case of doubt, please return device to manufacturer for repair or maintenance. 4. Warning: Do not use this product as safety or emergency stop devices, or in any other application were failure of the product could result in personal injury or material damage. Failure to comply with these instructions could result in death or serious injury and material damage. 5 Components solenoid valve with sieve sealing-ring GEWAS control unit adapter plug with water sensor switchable protective contact socket

S07.0.1X.6C-04 Operating Manual GEWAS 181 A page 4 of 6 6 Installation and commissioning 6.1 Installation of the solenoid valve - Lock water feed lines. - Insert sieve sealing ring. Please take care having clean sealing surfaces. - Screw solenoid valve via turn able connecting nut on the water supply. Keep the solenoid valve in desired position. - Check leak tightness by turning on the water supply. In case of leakage repeat the process above. - Screw water connection tube onto the outlet of the solenoid valve (use existing sealing ring or make sure that the tube itself is properly sealed! ). The brushing can be hand tightened if the installation was carried out correctly. In case of leakage check weather sealing ring has been inserted correctly or all sealing surfaces are clean, also check weather installation has been carried out correctly. Repeat installation process if. Hint for commissioning: The solenoid valve will only be opened if the control unit device has been turned on. water connection sieve sealing ring solenoid valve sealing ring hose connection 6.2 Installation of the control unit and the water sensor - Make a rule to read the operating and maintenance advices before starting up the device. - Use bail to hang the device on desired place, align the device. Remove the protective film from the adhesive tape at the device s back and press on the device for locating the device. - Place the water sensor and fixate it when needed. Please take care that the sensor electrodes do not touch any metallic surfaces, this may cause errors. - Connect water sensor to the control unit. - When not already done turn on water supply for the solenoid valve. - Plug the control unit s adapter plug into a socket outlet with protective contact. - Turn on the control unit via power switch and pressing service button at the same time. A red LED indicates the device is operating and the solenoid valve has opened. - Check water connection tubes for leakage. - Connect washing machine resp. dishwasher to the protective contact socket of the control unit. - FUNCTION TEST: Check the alarm function via bypassing the water sensor electrodes (e.g. via touching both electrodes). The device will now start its alarm; the solenoid valve will be closed. Turn off and on the control unit.! Well done, your GEWAS device is now ready for use! 7 Function When a water film at the water sensor exceeds 0.5 mm, the control unit will automatically initiate an audible alarm, will be closing the solenoid valve and will turn off the device connected to the power sockets of the device. To remove the alarm the control unit has to be turned off. When the water sensor is disconnected from the device, the alarm will also be initiated. 8 Operating elements Switch POWER Position 0: GEWAS-control unit is switched off, protective contact socket is powered off, solenoid valve is closed Position 1: GEWAS-control unit is switched off, monitoring is active, water can flow. protective contact socket is powered except there is an alarm condition Button SERVICE In normal operation (no alarm) the valve is operated in a low power mode. In case of calcification or similar soiling the valve may be locked in position. With the SERVICE button the operation current can be raised for a short time, which helps a blocked low power valve to operate regular again.

S07.0.1X.6C-04 Operating Manual GEWAS 181 A page 5 of 6 9 What to do in case of alarm Turn off the possibly connected device and the GEWAS control unit (POWER to 0 ). Seek and eliminate error causes. Possible error causes: - A water film is located at the water sensor. - The contacts of the water sensor are bypassed (e.g. via a metal surface) - The water sensor has been disconnected or is defective. Turn on the GEWAS control unit (POWER to 1 ) and press service button at the same time. Turn on the connected device (if necessary). 10 Operating and maintenance advices 1 Please Note: When the control unit is turned off, the power socket could be electrically live, and for that, a connected device is turned on! Attention: Before turning off the control unit, for turning off the alarm, the device connected to the GEWAS 181A (e.g. Washing machine, dish washer, etc.) should be turned off, because it will be turned on when you deactivate the control unit device. 2 The solenoid valve is servo controlled. This means that the pressure on the water inlet must be at least 0.5 bar higher than the pressure on the water outlet. This will be circumstance when the water flows out of the outlet with opened water supply. When this condition is not fulfilled, the solenoid valve will not be able to open. 3 Pressing the SERVICE button on turning on the device is not required. This is for deactivating the internal power saving circuit in order to raise the pull-in power of the solenoid valve to about 4-times. This is to prevent that in the course of time calcification of the solenoid valve make it opening difficulty resp. inhibit opening. 4 It may happen that the solenoid valve closes and does not open again after a short electrical power outage. In this case you have to turn the control unit off and on again the solenoid valve will open again. 5 In order to ensure long-time and trouble-free operation the device has to be checked regularly (like its usual with any safety device). Therefore the sensor contacts of the water sensor have to be bypassed (by a spoon, knife, etc.) at least every month. When doing so the solenoid valve should react with an audible.clack.. This is for making sure that, even with calcareous water and not regularly operated, the solenoid valve is fully operational regardless of the calcareous deposits. 6 The solenoid valve is operated with an internal power saving circuit. The total power consumption at permanent operation will only be 4 W. It is normal that the solenoid valve is warming up (the magnetic head to approx. 50 C and the brass housing will get hand-hot). 7 In order to ensure tightness in perpetuity, foreign substances (like stones, sand, etc.) must be kept away from the tube of solenoid valve. Therefore clean the screen of the solenoid valve from time to time 8 The device has to be treated and handled carefully in accordance with the above specification (do not throw, do not bump into sth. etc.). 9!!! Do NOT use the GEWAS in a humid environment!!! 10 Keep the magnetic head dry! Water may destroy the magnetic head! Pay attention that the water tap is tight in order to prevent that no water drops onto the solenoid valve resp. the magnetic head.

S07.0.1X.6C-04 Operating Manual GEWAS 181 A page 6 of 6 11 Specification Power supply: Power consumption: Control output: Switching voltage: Switching current: 220/240V, 50/60Hz (control unit) approx. 2.5 W (control unit, approx. 6W incl. solenoid valve) via power socket in the adapter plug with grounding contact equivalent to supply voltage max. 16A (ohmic load) Solenoid valve: 1/2" brass-solenoid valve with 3/4" screw connection hand assembly Working pressure: 10 bar, servo controlled (pressure difference inlet/outlet >0,5 bar) Operating voltage: 200 VDC resp. 100 VDC in power saving mode Working temperature: 0 to 50 C Dimension: control unit: 110 x 65 x 45 mm (L x W x H) solenoid valve: approx. 82 x 88 x 72 mm EMC: The device are corresponding to the essential protection ratings established in the Regulations of the Council for the Approximation of Legislation for the member countries regarding electromagnetic compatibility (2004/108/EG). 12 Disposal instructions The device must not be disposed in the unsorted municipal waste! Send the device directly to us (sufficiently stamped), if it should be disposed. We will dispose the device appropriate and environmentally sound.