CAN and Serial Instrumentation

Similar documents
Digital Instrumentation Model 3501

EMC and Durability Lab, HCL Technologies Ltd., #73-74, South Phase, Ambattur Industrial Estate, Chennai

MODEL FP-10. Read Instructions Carefully! CURTIS INSTRUMENTS, INC Kisco Ave. Mount Kisco, New York

Battery Monitoring System

Series AM2D-Z 2 Watt DC-DC Converter

Model Number Structure

Surface mounting, flush mounting, and DIN track mounting

AC Induction Motor Controller with VCL

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

GB60S 60W Single Output General Purpose Series

Safety Standards. Model Number:

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Power Conversion. Battery Chargers. Model

Max. Output Power. Efficiency (1) 110Vac 220Vac. 450 ma 90 ~ 305 Vac 445 Vdc 200 W 92% EUC-200S045ST

High Current Thermal Fuse

Note1: tested at nominal Vin, full load and at +25 C ambient. Package (3) CTRL Logic (2)

VOLUNTARY CODE OF PRACTICE FOR ELECTROMAGNETIC COMPATIBILITY (EMC) OF MOTOR VEHICLES (13 October 2014)

3M CP2 Press-Fit Headers and Sockets, 2 mm

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

Lexium integrated drives

IMMOBILISER SYSTEM INTRODUCTION

EM DC Multi-Function DC Energy Meter

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

1 second start up, no external components 220µF <1 second start up + diode protection circuit 6800µF

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input)

MODEL 908. Read Instructions Carefully! Fuel Gauge CURTIS INSTRUMENTS, INC.

A21M. Introduction: Functional Overview: Key Protection & Control Functions:

High Power Directional Coupler

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ.

Series AM1P-Z 1 Watt DC-DC Converter

Pressure measurement PP20H Fully welded hygienic pressure sensor with flush membrane

Power Conversion. Battery Chargers. Model

Series AM2D-Z 2 Watt DC-DC Converter

SA2 Series High Voltage Gas Discharge Tube

Proportional pressure relief valve, directly operated, rising characteristic curve

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

Test Report No.: SHHG BC Date: JAN.31,2013 Page: 1 of 12

USB3.0 for Active Optical Cable

P-Series 11 to to to to to to to 1100 >1000 <25

Open Frame Power Supplies

产品技术规范. Product Name: Product Technical Specification SMARTSTONE. No.: CPFL0002 Version: A Issued date: Page 1 of 16

Diesel generator set B3.3 series engine 44 kva - 66 kva 50 Hz 40 kw - 60 kw 60 Hz

Switching Power Supplies

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

Actuator LA35. Data sheet LINAK.COM/TECHLINE

Industrial Power Supplies

Packaging (1) Package

Series AM2S-Z 2 Watt DC-DC Converter

RVS-DN Digital Reduced Voltage Motor Starter

Separately Excited Electronic Motor Speed Controller Model 1243 SepEx

Diesel Generator Set S3.8 Series Engine

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

Load (2) Single or Dual

C B. Operating up to 5000m altitude 5 year product warranty Models

RVS-DX Digital Reduced Voltage Motor Starter

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010

STT280 SEALED TILT SENSOR

AUTOMOTIVE EMC TEST HARNESSES: STANDARD LENGTHS AND THEIR EFFECT ON RADIATED EMISSIONS

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12)

Stepper motors EMMS-ST

LDX-C120 Series is a 120 W integrated DIN Rail Battery Charger / DC UPS Power Supplies, suitable for wide variety of industrial applications.

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Solid State Relays contactor with Integrated Fuse Type RGC1F

VZCA2.E VZCA8.E CQC CQC CQC CQC CQC D-Seires. 11 to to 1465.

Maximum Input Current Vin=18V, 100% Load A Vin=24V ma No-Load Input Current

USB3.0 For Active Optical Cable SPECIFICATIONS

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

Power Conversion. Battery Chargers. Model

XMLR160M2P05 Pressure sensors XMLR 160bar - G 1/4-24VDC - 2xPNP - M12

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

SAV Electronic Valve Actuator

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces:

Rental Power QSB7 series engine

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Pressure Transmitter for wind turbine applications MBS 8200 and MBS 8250

Power Supplies. SDN-C Compact DIN Rail Series

USB3.0 For Active Optical Cable SPECIFICATIONS

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 100 WATT RAILWAY APPLICATIONS HWB100 SERIES

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

VSD Series II Variable Speed Micro Drives

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

Angle sensor AN2 series 30

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

US-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability

Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies Part Numbers

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

Transcription:

Instrumentation Models 3140 and 3141 www.curtisinstruments.com 1

Curtis Models 3140 and 3141 are designed to display critical vehicle and motor controller data in an easy-to-read and attractive LCD. The display includes three 10mm digits and six 5mm digits and all digits are in 16-segment format to allow the full use of the alpha numeric character set. Model 3141 adds three LED indicators below the LCD to identify critical vehicle status. Models 3140 and 3141 integrate seamlessly with Model F2-A and other CANopen-based motor controllers. FEATURES Integrates seamlessly with Curtis Model F2-A (and other CANopenbased motor controllers) thereby reducing the amount of development work by the vehicle designer. Attractive fixed-segment, transflective LCD with 16-segment digits and informative symbology allows intuitive reading in all lighting conditions and battery-powered vehicle environments. Model 3141 features 3 LED s in the instrument face which are controllable via the CANbus and can be illuminated to identify critical user-defined functionality. Industry standard 52mm panel cutout allows the use of existing panel/tool designs thereby lowering development cost. Battery State-of-Charge (BSOC) can be calculated in the 3140/1 or sent to the 3140/1 by the Model F2-A (or equivalent CAN-based motor controller). Models 3140/1 will run at one of seven selectable baud rates: 20kbps, 50kbps, 125 kbps, 250 kbps, 500 kbps, 800 kbps, and 1 Mbps. The baud rate can be factory programmed or changed by an SDO. In addition to the 3 and 6 digit portions of the LCD, a percent symbol, wrench symbol and decimal point are also present which provides more comprehensive information about vehicle status. Single unit operates from 24, 36 or 48 VDC allowing use on many models of battery-powered vehicles. Optional backlighting and LCD heater allow use in low-light and cold-store applications. Optional integral CAN termination resistor allows flexibility in customer vehicle design. Integrated 6-pin Mini-Universal MATE-N-LOCK connector allows for an easy and environmental protected connection. Environmentally protected (IP65 front, IP54 rear) to allow use in harsh environments. CE compliance, UL recognition and RoHS2 compliance ensure compatibility with global regulatory standards. www.curtisinstruments.com 2

DIMENSIONS mm 29.0 MIN VIEWING AREA Ø 60.0 35.0 MAX 19.4 MIN VIEWING AREA 51.5 MAX Ø 40.0 ø52.0±0.4 5.0 30.0 MAX 50.8±0.4 OPTIONAL KEY 2.5±0.2 www.curtisinstruments.com 3

SPECIFICATIONS Electrical Models 3140 and 3141 are designed to operate over these voltage ranges: Model Min. Nominal Max. 2448 18 V 24 48 V 60 V 12V only 9 V 12 V 32 V 12248V operating currents: Non-Backlit Models Backlit Models LCD Heater Typical Max. Typical Max. B+ (24V) 14 20 24 30 140 B+ (28V) 14 20 25 31 170 B+ (36V) 14 20 25 31 140 B+ (48V) 15 21 25 32 98 B+ (60V) 15 21 26 33 82 12V operating currents: Non-Backlit Backlit LCD Models Models Heater Typical Max. Typical Max. B+ (9V) 13 20 19 25 325 B+ (12V) 14 20 22 27 400 B+ (24V) 14 20 24 30 205 B+ (32V) 15 21 26 33 150 Environmental Operating Temperature: 10 C to +85 C (with optional LCD heater: 40 C to +85 C). Storage Temperature: 40 C to +85 C. Humidity: Soak: Designed to meet EN 60068-2-78. Test Cab: Damp Heat, Steady State, 10 days at 93% RH (±3%), 30 C. Cyclic: Designed to meet EN 60068-2-30. Test Db: Damp Heat, Cyclic (12hr + 12hr cycle). Test method variant 1. 6 cycles (each cycle is 24hrs), 90% RH. Ingress Protection: The 3140 is designed to meet EN 60529 Face: IP65; Rear surface: IP54. The 3141 is designed to meet EN 60529 Face: IP67; Rear surface: IP67. Shock: Applicable to enclosed units only: designed to meet EN 60068-2-27: 3 shocks in all 3 axes in both directions (18 shocks in total), 500 m/s², 11ms, half sine wave. Vibration: The following vibration specifications are applicable to enclosed units only: General: Designed to meet EN 60068-2-6, Swept Sine Wave method, 5g, 20 cycles in each plane, 5 to 500 Hz, 1 Octave/min. ; Amplitude = +/ 15mm; Amplitude < +/ 15mm; Acceleration = 5g. Random: Designed to meet EN 60068-2-64. Test Fh: vibration, broadband random (digital control) and guidance. Method 1, random excitation, 5hrs in each axis, 10 to 350 Hz. Resonance: Designed to meet EN 60068-2-6. Vibration sinusoidal, 5g, 5 mins at resonant points, 1 Octave/min, Swept Sine Wave 10 to 2000 Hz. EMC Specifications Emissions (Broadband & Narrowband) Designed to meet UN ECE/324 Addendum 9 Regulation 10 Revision 4 (6 March 2012) for an Electrical/electronic sub-assembly (ESA). Immunity ESD: Designed to meet IEC 61000-4-2: Test level IV (8 kv contact discharge or 15 kv air discharge) according to ISO 10605:2001, Table B.1. Radiated Imunity: Designed to meet 30 V/m (20MHz to 1 GHz) when tested per ISO 11452 2, Absorber-Lined Chamber (single sample). Conducted Immunity: Designed to meet IEC 61000-4-4: Test level 4 (4 kv peak, 2.5 khz repetition rate). www.curtisinstruments.com 4

SPECIFICATIONS continued Regulatory Approvals UL: UL recognition to UL 583. CE: The product complies with the requirements of the EMC Standards and RoHS directive 2011/65/EU (RoHS 2). The product conforms to the following product specifications and regulations: EMC: Radiated Emissions: UN ECE/324; Radiated Immunity: ISO 11451-1 and ISO 11451-2, using the RF levels defined in BS EN 13309:2010; Electrical Transient Conduction: IEC 61000-4-4: Test level 4 (4 kv peak, 2.5 khz repetition rate); ESD: ISO 10605: 2001. RoHS: RoHS directive 2011/65/EU (RoHS 2). MODEL ENCODEMENT 3140 = No LEDs 3141 = 3 LEDs 2448 V 12 V only B = Backlight N = No Backlight O = Curtis Logo N = No Logo Example Model 3140 R 2448 H N XXX O R = 52mm RS = 52mm sealed P = Uncased Module H = LCD htr N = No LCD htr Sequential Number NOTE: Model 3140 can be specified with a factory set baud rate and/or an integral CAN termination resistor. CONNECTOR Pin Signal Name Description PIN 1 CAN HI CANbus high signal PIN 2 B+ Battery Positive PIN 3 B Battery Common PIN 4 Heater B LCD Heater B PIN 5 Heater B+ LCD Heater B+ PIN 6 CAN LO CANbus low signal NOTE: The LCD Heater B+ and LCD Heater B pins must be tied to B+ and B, respectively. 3 2 1 6 5 4 WARRANTY Two year limited warranty from time of delivery. is a trademark of Curtis Instruments, Inc. Specifications subject to change without notice 2018 Curtis Instruments, Inc. 50302 REV E 8/18 www.curtisinstruments.com 5