Signet DryLoc ph/orp Electrodes

Similar documents
Signet DryLoc ph/orp Electrodes

Signet ph/orp Electrodes

Signet 3719 ph/orp Wet-Tap Assembly

Signet ph/orp Electrodes

Signet ph/orp Electrodes

Signet 2760 DryLoc ph/orp Preamplifiers & Connectors

Signet Conductivity/Resistivity Electrodes

Signet 4150 Turbidimeter

* * Rev. 9 01/18 Product Manual

Signet 515 Rotor-X Paddlewheel Flow Sensors

Signet 2536 Rotor-X Paddlewheel Flow Sensors

Signet 2760 DryLoc ph/orp Preamplifier

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor

Signet Conductivity/Resistivity Electrodes

Signet V(D) to V(D) PVDF Conductivity Electrodes

SIGNET 2760 DryLoc ph/orp Preamplifier

Signet 3719 ph/orp Wet-Tap

Signet 515 Rotor-X Paddlewheel Flow Sensors

Signet 2551 Magmeter Flow Sensor

SIGNET 2750 ph/orp Sensor ENGLISH

SIGNET 3719 ph/orp Wet-Tap

Models 396/396P/396R. Retraction/Submersion/Insertion ph/orp Sensor

* * Signet 2450 Pressure Sensor. Product Manual. English. Description. Dimensions Rev /18

General Purpose ph/orp Sensors

ph/orp Sensor Model 399 ph/orp

NEW QUICK CABLE-TO-SENSOR RELEASE,

General Purpose ph/orp Sensors

Combination ph/redox (ORP) Sensors

Combination ph/redox (ORP) Sensors

AP300 Series Combination ph/redox (ORP) Sensors. Measurement made easy. A reliable economic solution for a wide range of applications

TUpH Retraction/Submersion/Insertion ph/orp Sensors

Signet ph/orp Transmitter

Insertion/Submersion Flow Through Sensor

TUpH 396, 396VP, 396P, 396PVP, 396R, 396RVP

Low Cost Submersion and In-Line ph Electrodes

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

7777 Immersion/In-Line Mounting for Meredian II ph/orp Electrodes Installation and Maintenance Manual

Signet Pressure Transmitter

Orbisint CPS12/CPS12D/CPS13

ABB MEASUREMENT & ANALYTICS DATA SHEET. TBX5 ph, Redox (ORP) sensors with diagnostics

Signet 515/2536 Rotor-X Flow Sensors * * Operating Instructions. English. Description Rev. X 05/17

CPM280. Technical Information. ph/orp measurement Battery-driven pocket meter for ph and ORP measurement

Low Cost Submersion and In-Line ph Electrodes

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

* * Rev. F 03/16 Operating Instructions

Dissolved Oxygen, ph, and Conductivity

Encapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials)

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP200 Rugged ph/redox (ORP) sensor systems with rapid temperature response for critical processes

SIGNET Temperature Transmitter

Signet Temperature Transmitter

Retractable ph/orp Sensors

JUMO tecline HD ph and JUMO tecline HD Rd

SIGNET 7002 Vortex Flow Sensor ENGLISH

Accessories Guide ph/orp/conductivity Sensors

Measurement & Instrumentation 2005 Product Catalog on CD. Creating Quality by Connecting Technology to Life. Click on image to begin.

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.K February 2013

Rosemount 3300HT/3300HTVP/3400HT/ 3400HTVP/3500P/3500VP

Retractable ph/orp Sensors

Retractable ph/orp Sensors

Retractable ph/orp Sensors

Signet 2517 Brass Paddlewheel Flow Sensor * *

Signet 2552 Metal Magmeter

Signet 2552 Metal Magmeter

General Specifications

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.G February 2006

Performance Series ph/orp Sensors

Liquid Conductivity Two & Four Electrode Sensors

7777D In-Line Mounting for Durafet II ph Electrodes Installation and Maintenance

Digital ph transmitter

Performance Series ph/orp Sensors

Rugged ph/redox (ORP) Sensor Systems with Rapid Temperature Response for Critical Processes

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.I December 2008

OPERATING INSTRUCTION MANUAL

General Specifications

Instrument Enclosure Assemblies

SIGNET Vortex Flow Sensors ENGLISH

General Specifications

GF Signet. Measurement & Control Sensors. Signet Price List 1st Aug 2011 Rev 0.0

INTERNATIONAL METAL ENGINEERING

Signet 7000/7001 Vortex Flow Sensors * *

G2 Industrial Grade Meters

Orbipore CPS91 and CPS91D

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

General Specifications

Digital ph transmitter

Signet Measurement and Instrumentation

Pasve Rotary Retraction Valve

Product Type Manufacturer Beginning Page Conductivity Liquid Level Controls ABB SSAC 12/2

* * Rev M 10/14 Operating Instructions

Model 7777DVP Immersion/In-Line Mounting for Durafet III ph Electrodes Installation and Maintenance Rev. 1 3/04

CONTACTING CONDUCTIVITY GENERAL PURPOSE SENSORS Instruction Manual

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands

Signet Measurement and Instrumentation

Analytical Instruments Two-Electrode Conductivity Sensors

Performance Series ph/orp Sensors

871PH Series ph, ORP, and Fluoride Sensors and Accessories

Foxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element

8000 Series ph/orp Electrode Platform Product Instructions

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.J January 2011

Combination ph/redox (ORP) Sensors

Transcription:

Signet 2774-2777 DryLoc ph/orp Electrodes Features Patented DryLoc connector with gold plated contacts* Special design allows for installation at any angle, even inverted or horizontal Quick temperature response Easy sensor replacement using DryLoc electrode connector High temperature versions available Mounts into standard ¾ inch threads Flat Glass Protected Bulb Compatible with all Signet instruments and other suppliers ph/orp instruments The Signet 2774-2777 ph and ORP Electrodes feature a unique foul-proof DryLoc connector with goldplated contacts designed specifically for use with the Signet 2750 and 2760 preamplifiers, sensor electronics, and connectors. These dependable and highly responsive electrodes feature a PTFE double reference junction with KNO 3 in the front chamber to block various poisoning ions such as Copper (CU ), Lead (Pb ), Mercury (Hg ), and a large reference chamber that combine to extend the service-life. Embedded positioning of the temperature element in the ph sensing tip allows the temperature response to be quick and accurate. The electrodes are offered with either flat or bulb style sensing elements. The flat versions allow sediment and particles to sweep past the measurement surface, minimizing risks of abrasion, breakage and coating. The bulb versions can be used for general-purpose applications. Due to the specially designed chambers which keep electrolyte in place, all versions can be installed at any angle, even inverted. Applications Water Treatment & Water Quality Monitoring Cooling Tower and Boiler Protection Aquatic Animal Life Support Systems Pool and Spa Control Neutralization Systems *U.S. Patent No.: 6,666,701

Specifications General Compatibility Signet Models 2750 and 2760 Operating Range 2774/2776 0 to 14 ph 2775/2777 ±2000 mv (ORP) Process Connection ¾ in., for use in reducing tees up to 4 in. Reference Electrolyte KNO 3 /KCl polyacrylamide gel Element Ag/AgCl Wetted Materials Body Ryton Reference junctions PTFE Sensing surface ph Glass membrane ORP Platinum O-rings FPM Max. Temperature/Pressure Rating Operating Temperature 0 C to 85 C 32 F to 185 F Max. Operating Pressure 6.9 bar 100 psi Higher temperature and pressure sensors are available upon request. Recommended Storage Temperature 0 C to 50 C 32 F to 122 F The electrode glass will shatter if shipped or stored at temperature below 0 C (32 F) The performance life of the electrode will shorten if stored at temperatures above 50 C (122 F) Mounting In-line/Vertical Mounting Use the electrodes ¾ inch threads to install into pipe fitting. Electrode can be mounted at any angle. Submersible Mounting Use threads on Model 2750 or 2760; requires ¾ inch NPT or ISO 7/1-R 3/4 male threaded extension. Temperature Sensor ph 3 KΩ or PT1000 RTD ORP none Shipping Weight 0.25 kg 0.55 lb Standards and Approvals Manufactured under ISO 9001 for Quality

ENTER Profibus Address Power 24 VDC 0.40A Max L IN L IN- PWR- PWR- PWR- PWR PWR PWR USB Signet 3-0486 Profibus Concentrator Channel 1 S 3 L Freq L IN L IN- N/C L OUT L OUT- N/C Out In Channel 7 Valve Channel 2 S 3 L Freq L IN L IN- S 3 L Loop Channel 6 Channel 3 S 3 L Freq S 3 L Loop Channel 5 Channel 4 S 3 L Freq Dimensions 38.6mm (1.52 in.) 38.6mm (1.52 in.) 35.5mm (1.4 in.) 35.5mm (1.4 in.) 29.2mm (1.15 in.) 29.2mm (1.15 in.) 128.3mm (5.05 in.) 128.3mm (5.05 in.) 32mm (1.3 in.) 3/4 in. NPT 0.64 mm (0.25 in.) insertion depth, typical 43mm (1.7 in.) 3/4 in. NPT 22.8mm (0.9 in.) 0.64 mm (0.25 in.) insertion depth, typical 22.1mm (0.87 in.) 22.1mm (0.87 in.) Flat Electrode Bulb Electrode Panel Mount Pipe, Tank, Wall Mount 4 to 20 ma Output Automation System Signet Instruments 8750 with 2760 Preamplifier 8900 9900 with 2750 Electronics Signet Instruments 9900 with 2750 Electronics and Rear Enclosure 2750 Sensor Electronics and Customer Supplied Chart Recorder Programmable Logic Controller or Programmable Automation Controller 2750 Sensor Electronics with 0486 Profibus Concentrator and Customer Supplied Programmable Logic Controller or Programmable Automation Controller System Overview OR Signet 2774-2777 DryLoc ph/orp Electrodes OR PLC PLC All sold separately In-Line Installation - Threaded fittings only Submersible Installation - Customer supplied pipe extension or conduit with 3/4 in. NPT or ISO 7/1-R 3/4 threads and pipe assembly* *Refer to the Signet Submersion Kit brochure (3-0000.707) located on our website for installation suggestions and options. See Technical Reference section for assistance in choosing the correct sensor.

Electrode Key Features and Benefits DryLoc Connector Ryton body for chemical compatibility to most harsh chemicals. Also able to withstand high temperatures. Porous PTFE reference junctions are highly chemically resistant; resists fouling and dirt buildup. First reference chamber with KNO 3 protects Ag/AgCl wire for a prolonged sensor life. Capillary TC (temperature sensor) embedded in tip of ph electrode for quicker temperature response. DryLoc connector with corrosion resistant gold pins for quick and easy sensor removal. Reference Ag/AgCl Wire Double Porus PTFE Reference Junctions ph/orp Electrode Ryton Body Reference Electrolyte Chamber 1 st Reference Chamber with KNO 3 Capillary TC Application Tips Use the flat glass electrodes for in-line ph sensor applications when a self-cleaning feature is desired; especially useful in applications with abrasive chemicals. Use bulb protected electrodes for general purpose applications ORP electrodes are generally used for chemical reaction monitoring, not control. Ensure that sensor materials are chemically compatible with the process liquid. Keep electrode tip wet, avoid air pockets and sediment. Model 2774-2777 Ordering Notes 1) ph and ORP sensors require connection to model 2750 or 2760. 2) Conduit and mounting brackets for submersible installation must always be used (customer supplied). 3) All of these sensors can be installed upside-down. 4) Special order options may have longer delivery time. Consult your local Georg Fischer sales representative for lead times.

Temperature/Pressure Graph Note: The pressure/temperature graphs are specifically for the Signet sensor. During system design the specifications of all components must be considered. In the case of a metal piping system, a plastic sensor will reduce the system specification. (psi) 150 125 100 (bar) 10.3 8.6 6.9 -HT Special Electrodes only Standard Electrodes 75 5.2 50 3.4 25 1.7 0 C -40-20 0 20 40 60 80 100 120 F -40-4 32 68 104 140 176 212 248 Please refer to Wiring, Installation, and Accessories sections for more information.

Ordering Information Mfr. Part No. Code Tip Design Temperature Element ph Electrodes 3-2774 159 000 955 Flat 3K Ω RTD¹ 3-2776 159 000 959 Bulb with Protection 3K Ω RTD¹ 3-2774-1 159 000 956 Flat PT1000 RTD² 3-2776-1 159 000 960 Bulb with Protection PT1000 RTD² ORP Electrodes 3-2775 159 000 957 Flat 10 K ID Resistor 3 3-2777 159 000 961 Bulb with Protection 10 K ID Resistor 3 3-2775-1 159 000 958 Flat No T.C 4 3-2777-1 159 000 962 Bulb with Protection No T.C 4 1 3K Ohm RTD for connection to 8750 instruments when used with the 2760 preamplifier. The 2760 preamplifier is used for connection directly to Signet 8750 transmitter. 2 PT1000 RTD for connection to the 8900, 9900 or Profibus Concentrator when used with the 2750 sensor electronics. The 2750 sensor electronics has a digital (S 3 L) output which is used with the 8900 Controller, 9900 Transmitter, and the Profibus Concentrator. It also has a 4 to 20 ma output for connections to PLC s, data recorders, etc. 3 10 K ID resistor for connection to the 8750 when used with the 2760 preamplifier or the 8900 when used with the 2750 sensor electronics 4 For use with other suppliers instruments when used with the 2760 connector Special Order Options - Please consult the factory for ph and ORP Electrodes - Options -HT and -C can only be used with the 3-2722 BNC Adapter. These options cannot be used with the 2750 or 2760. -HT High Temperature and Pressure options, up to 110 C (230 F) @ 150 psig; DryLoc connector is removed and replaced with a 4.6 m (15 ft) cable. -C Remove DryLoc connector and add 4.6 m (15 ft) cable. Other cable lengths are available. -ISO ISO 7/1-R 3/4 Threaded electrodes are available. Accessories and Replacement Parts Mfr. Part No. Code Description 3-2700.395 159 001 605 Calibration kit: includes 3 polypropylene cups, box used as cup stand, 1 pint ph 4.01, 1 pint ph 7.00 3822-7115 159 001 606 20 gm bottle quinhydrone for ORP calibration (must use ph 4.01 and/or ph 7.00 buffer solutions) 3-0700.390 198 864 403 ph buffer kit (1 each 4, 7, 10 ph buffer in powder form, makes 50 ml of each) 3822-7004 159 001 581 ph 4 buffer solution, 1 pint (473 ml) bottle 3822-7007 159 001 582 ph 7 buffer solution, 1 pint (473 ml) bottle 3822-7010 159 001 583 ph 10 buffer solution, 1 pint (473 ml) bottle 3-2759 159 000 762 ph/orp system tester 3-2759.391 159 000 764 Adapter cable for use with 2750/2760 3-2721 198 864 610 Remote mount ph/orp preamplifier 3-2722 Special Order BNC adapter 3-2774.099 Rev D (02/16) Georg Fischer Signet LLC 3401 Aero Jet Avenue, El Monte, CA 91731-2882 U.S.A. Tel. (626) 571-2770 Fax (626) 573-2057 e-mail: signet.ps@georgfischer.com Specifications subject to change without notice. All rights reserved. All corporate names and trademarks stated herein are the property of their respective companies.