Filter FIA and FIA-SS

Similar documents
Filter type FIA (½ - 12 in.) type FIA-SS (½ - 2½ in.) REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Filter type FIA (½ - 12 in.) REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Strainers in stainless steel Type FIA SS

SVL product range with butt-weld connection F

Stop valves SVA-S and SVA-L

Shut-off valves Types SVA-S and SVA-L

Stop valves SVA-S and SVA-L

SVL parts program 65 bar (943 psi) series

Stop check valves, SCA-X Check valves, CHV-X

Stop check valves type SCA , SCA-SS Check valves type CHV , CHV-SS Technical leaflet REFRIGERATION AND AIR CONDITIONING

Stop check valves type SCA Check valves type CHV Technical leaflet REFRIGERATION AND AIR CONDITIONING

Pressure control valve Type KDC

Check & stop valve, SCA-X Check valve, CHV-X

Shut-off Check valves and regulating valves for for Industrial Refrigeration

Stop valves SVA-DL & SVA-DH

Shut-off Check valves and regulating valves for for Industrial Refrigeration

Stop Needle Valves SNV-ST and SNV-SS

Shut-off valves Types SVA-DL and SVA-DH

FA + solenoid valve Type ICF 15/20 EVRAT

Shut-off valves in stainless steel Types SVA-S SS and SVA-L SS

Shut-off valves in stainless steel SVA-S SS

Gauge valves Type SNV-ST and SNV-SS

Pilot Controlled Servo Valves ICS

Float Switch AKS 38. Technical brochure MAKING MODERN LIVING POSSIBLE

Pilot operated main valves for regulating pressure and temperature, type PM

Pilot-operated servo valve Type ICS

Liquid level switch Type AKS 38

Pilot-operated servo valve Type ICS

Pilot-operated servo valve Type ICS

Refrigeration and Air Conditioning Controls. Technical leaflet. Stop valves type SVA 6-10 REFRIGERATION AND AIR CONDITIONING

Float valve Type HFI. Data sheet

Pilot controlled servo valves Type ICS - Solenoid Valves Pressure Regulating Valves. Technical leaflet MAKING MODERN LIVING POSSIBLE

Temperature regulating valve Type ORV

Capacity regulators (hot gas bypass) PMC and CVC

Solenoid valves type EVRA 3 to 40 and EVRAT 10 to 20

Valve Station in stainless steel ICF SS 20 and ICF SS 25

High pressure float valve, type HFI REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Modulating liquid level regulators, direct-controlled SV 1 and SV 3

Pilot valves for servo operated main valves

Motor Valves type ICM Actuators type ICAD 600,900, 1200 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Solenoid valves, type EVRA 3 40 and EVRAT REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Pilot valves for servo operated main valves

Motor operated valves and Actuators Type ICM and ICAD

Solenoid valves EVRA and EVRAT

CCMT - Electrically operated valves for transcritical and subcritical CO2

Motor operated valves and Actuators ICM and ICAD 600A-1200A

Liquid level control. Thermostatic liquid level regulators, type TEVA. High pressure float valve, type HFI

Electric expansion valves Types AKVA 10, 15 & 20

Valve Station ICF 20-40

Valves For Cryogenic Applications

Valve station ICF 15, ICF EVRAT, ICF 20, ICF SS 20

Pilot valves Types CVP, CVPP, CVC, CVE, EVM and CVH

Technical brochure Eliminator filter drier DCR - with replaceable solid core

Pilot valves for servo opereated main valves REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Valve station ICF 15, ICF EVRAT, ICF 20, ICF SS 20

Strainer PN 25/40 DN

INTRODUCTION AND STANDARD SPECIFICATIONS

10.1 Introduction Connections Overview

CE43 1" (DN25) to 4" (DN100) Carbon Steel Cage Design, Two Port Control Valves

T EN Type 3347/3379 Pneumatic Control Valve Type 3347 Hygienic Angle Valve

Size : Ends : Min Temperature : Max Temperature : Materials : Stainless steel

Inline Filter RFL. Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar

PF6 Stainless Steel Piston Actuated On/ Off Valves

RAIMONDI. High pressure forged check valves recommended to prevent flow reversal in severe applications.

ECOLINE GTC Type Series Booklet

Replaceable solid cores filter driers type CSR

Size : Ends : Min Temperature : Max Temperature : Materials : Carbon steel

Series 240 Type and Type Pneumatic Control Valves Type 3248 Cryogenic Valve

Series 2000 Top Guided Control Valve

NON-RETURN VALVE RT25

Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm

IBV Series C-LF2 Carbon Steel Inverted Bucket Vertical Steam Trap

PV4 and PV6 Piston Valves

Stainless Steel Valves

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Pressure switch and Thermostat Type CAS

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices Metering pipe with orifice plate and annular chambers 4/369

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

Materials : Carbon steel or Stainless steel

KOSO HAMMEL DAHL. Specifications. Body Size: Globe - 1/2" through 6" ( mm). Angle - 1/2" through 2" (15-50 mm).

Visual Level Indicators (VLI) Economy Line 6

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

Size : Ends : Min Temperature : Max Temperature : Materials : Carbon or stainless steel

PRODUCT EVOLUTION. Be careful, our valves Ref.702 are changing

VACUUM HOSES AND VALVES

PRODUCE EVOLUTION. Be careful, our valves Ref are changing

Spiratec ST14, ST16 and ST17 Sensor Chambers and Sensors

Quality, Safety and Environment

Pressure and temperature controls, Type CAS

XV en /5 XV Knife gate valve DN

AWH ARMATUREN- WERK HALLE GMBH. Thermodynamic steam trap. Thermodynamic steam trap. Thermodynamic steam trap PN40. Thermodynamic steam trap PN63

FlowCon SH mm. Adjustable Dynamic Self Balancing Valve SPECIFICATIONS

ARI-Strainer. ARI-Strainer - Screen and supporting basket made of stainless steel. ARI-Strainer - Y-pattern with flanges

HANDBOOK SOLENOID VALVES. Ed SOLENOID VALVES VS-ED 01/ ENG 1

Two-Way Metal Seated Ball Valve Type 75-M

Single Seated Globe Control Valves

STERI-TROL Clean Service 'S' series Two-port and Three-port Control Valves - DN15 (½") to DN100 (4")

Materials : Ductile iron EN GJS body, PTFE seat

Suction Filter SF/SFM/SFF and Suction Filter Elements S/S..

Maintenance-free metallic seat shut-off globe valves

Transcription:

MAKING MODERN LIVING POSSIBLE Technical brochure FIA and FIA-SS FIA filters are a range of angle-way and straight-way filters which are carefully designed to give favourable flow conditions. The design makes the filter easy to install, and ensures quick filter inspection and cleaning. FIA filters are used ahead of automatic controls, pumps, compressors etc., for initial plant start-up and where permanent filtration of the refrigerant is required. The filter reduces the risk of undesirable system breakdowns and reduces wear and tear on plant components. FIA filters are equipped with a screen mesh of stainless steel, avail able in sizes 00, 50, 250 and 500µ (microns*), (US 50, 00, 72, 8 mesh*). * Mesh is the number of threads per inch. µ (microns) is the distance between two threads (µ = /000 ). Features Applicable to all coon refrigerants and all non-corrosive gases/liquids. net of stainless steel mounted direct without extra gaskets means easy servicing. FIA filter housing compatible with housings belonging to other Danfoss products. A compatibility overview can be obtained from local Danfoss Sales Company Two types of filter inserts are available: - A plain insert of stainless steel - A pleated insert (DN 5-200) with extra large surface, which ensures long intervals between cleaning and low pressure drop. FIA 5-40 (½ ½ ): A special insert (50µ) can be used in combination with a standard version when cleaning a plant during coissioning. FIA 50-00 (2-2 ): A large capacity filter bag (50µ) can be inserted for cleaning plant during coissioning FIA 50-00 (2-2 ) can be equipped with a magnetic insert for detention of iron particles and other magnetic particles. Each filter clearly marked with type, size and performance range Housing and bonnet of low temperature steel (FIA) or stainless steel (FIA-SS) in accordance with the requirements of the Pressure Equipment Directive and those of other international classification authorities Temperature range 60/+50 C ( 76/+02 F) Pressure range: FIA: 40 bar g (580 psi g) FIA-SS: 52 bar g (754 psi g) Classification: DNV, LR, SAQ, CRN, BV etc. To obtain an updated product certification list please contact your local Danfoss Sales Company Danfoss A/S (AC-MCI/MWA), 202-2 DKRCI.PD.FN0.A9.02 / 520H2207

Design Connections Available with the following connections: Butt-weld DIN (EN 0220) Butt-weld ANSI (B 6.0 Schedule 80), DN 5-40 ( / 2 - / 2 ) Butt-weld ANSI (B 6.0 Schedule 40), DN 50-00 (2-2 ) Socket Weld (ANSI B 6.), DN 5 - DN 50 ( / 2-2 ) FPT Female Pipe Thread, NPT (ANSI/ASME B.20.), DN 5-2 ( / 2 - / 4 ) Insert A filter grid and filter net of stainless steel ensure long element life. The filter net offers a very high degree of cleanability. Housing The filter housing is made of special, cold resistant steel (FIA) or stainless steel (FIA-SS) approved for low temperature application. Pressure Equipment Directive (PED) FIA filters are approved in accordance with the European standard specified in the Pressure Equipment Directive and are CE marked. For further details / restrictions - see Installation Instruction Nominal bore DN 25 ( ) DN 2-80 ( / 4 - ) DN 00-250 (4-0 ) DN 00 (2 ) Classified for Fluid group I Category Article, paragraph II III IV Installation/Maintenance The filter is designed to resist high internal pressures. However, the piping system in general should be designed to avoid liquid traps and reduce the risk of hydraulic pressure caused by thermal expansion. Install the filter with the cover downward position. Danfoss recoends replacement/cleaning of the filter when the differential pressure loss >0.5 bar (7. psi) in the liquid line and >0.05 bar (0.7 psi) in the suction line. The max. permissible differential pressure is bar (5 psi). For further information refer to installation instruction for FIA. Identification: DN 5-25 ( / 2 - ) DN 2-00 ( / 4-2 ) Technical data Refrigerants Applicable to all coon refrigerants including flaable refrigerants and all non-corrosive gases/liquids. For further information please see installation instruction for FIA. Temperature range 60 C/+50 C ( 76 F/+02 F). Pressure range Max. working pressure: FIA: 40 bar g (580 psi g). FIA-SS: 52 bar g (754 psi g). 2 DKRCI.PD.FN0.A9.02 / 520H2207 Danfoss A/S (AC-MCI/MWA), 202-2

Selection of filter size The mesh aperture size of the filter must satisfy the requirements stated by the sup pliers of the equipment to be protected. The following recoendations of aperture size apply in general to refrigeration installations: All lines First start up:... 50µ (Use filter element with removable insert for FIA DN5-40 or separate filter bag for FIA DN 50-200. 50µ insert should normally be removed after the first 24 hours of operation) Definition Mesh is the number of threads per inch. µ (microns) is the distance between two threads (µ = /000 ). Liquid Lines Ahead of pumps:... 500µ After pumps:... 50µ In front of AKVA valves... 00µ Protection of automatic regulation equipment Generally... 50µ Sensitive equipment, e.g. suction regulators with low temperature... 250µ Suction Lines Ahead of screw compressor... 250µ Ahead of piston compressor... 50µ [8 mesh] [00 mesh] / 250µ [72 mesh] [50 mesh] [00 mesh] / 250µ [72 mesh] [72 mesh] [72 mesh] [00 mesh] Flow coefficient (DIN/ANSI) µ mesh wire FIA 5-20 ( / 2 - / 4 ) 25-40 ( - / 2 ) 50 (2 ) 65 (2 / 2 ) 80 ( ) 00 (4 ) 25 (5 ) 50 (6 ) 200 (8 ) 250 (0") 00 (2") wire free screen area space Plain elements Pleated elements % cm 2 in 2 cm 2 in 2 00 0.068 0.00 5 25.9 45 7.0 50 00 0.0 0.004 6 25.9 45 7.0 250 72 0.0 0.004 5 25.9 45 7.0 500 8 0.6 0.006 57.6 25.9 45 7.0 00 0.068 0.00 5 7 60 25.0 50 00 0.0 0.004 6 7 60 25.0 250 72 0.0 0.004 5 7 60 25.0 500 8 0.6 0.006 57.6 7 60 25.0 00 0.068 0.00 5 7 200.2 50 00 0.0 0.004 6 87.5 200.2 250 72 0.0 0.004 5 87.5 200.2 500 8 0.6 0.006 57.6 87.5 200.2 50 00 0.0 0.004 6 27 9.7 05 47.6 250 72 0.0 0.004 5 27 9.7 05 47.6 500 8 0.6 0.006 57.6 27 9.7 05 47.6 50 00 0.0 0.004 6 205.8 450 70.2 250 72 0.0 0.004 5 205.8 450 70.2 500 8 0.6 0.006 57.6 205.8 450 70.2 50 00 0.0 0.004 6 70 57.4 790 2.2 250 72 0.0 0.004 5 70 57.4 790 2.2 500 8 0.6 0.006 57.6 70 57.4 790 2.2 50 00 0.0 0.004 6 50 79. 05 72.4 250 72 0.0 0.004 5 50 79. 05 72.4 500 8 0.6 0.006 57.6 50 79. 05 72.4 50 00 0.0 0.004 6 726 2.5 600 249.6 250 72 0.0 0.004 5 726 2.5 600 249.6 500 8 0.6 0.006 57.6 726 2.5 600 249.6 50 00 0.0 0.004 6 5 20.8 250 72 0.0 0.004 5 5 20.8 500 8 0.6 0.006 57.6 5 20.8 50 00 0.0 0.004 6 800 70.9 250 72 0.0 0.004 5 800 70.9 500 8 0.6 0.006 57.6 800 70.9 50 00 0.0 0.004 6 2590 02.0 250 72 0.0 0.004 5 2590 02.0 500 8 0.6 0.006 57.6 2590 02.0 Danfoss A/S (AC-MCI/MWA), 202-2 DKRCI.PD.FN0.A9.02 / 520H2207

Selection of filter size (Continued) K v values DN FIA angle - plain filter net FIA angle - pleated filter net µ00 µ50 µ250 µ500 µ50 µ250 µ500 5..4.5.7 4.2 20 6.9 7. 7. 7.7 8.8 25.8 4.0 4.5 5.2 7.2 7.9 2 2.0 2.8 24.7 25.5 29.2 0.5 40 25. 25.5 26.4 28..4 2.6 50 45. 45.9 47.6 50.2 56.7 58.8 62.0 65 56. 57.8 60.4 69. 7.4 74.6 80 04.6 08.0. 29.2.4 9.7 00 62.4 67.5 76.0 200.6 206.9 27.4 25 275.4 28.9 298.4 40.2 50.7 68.6 50 62. 7.2 9.9 447. 200 572.9 590.8 620.5 250 784.5 808.9 849.7 00 062. 095.4 50.8 DN FIA straight - plain filter net FIA straight- pleated filter net µ00 µ50 µ250 µ500 µ50 µ250 µ500 5 2.5 2.6 2.7 2.8. 20 5. 5.4 5.6 5.9 6.9 25 0.5 0.7..6.8 4.5 2 7.6 8.2 8.9 9.5 2.9 24.7 40 9.2 9.5 20.2 2.5 25.5 26.4 50 4.5 5. 6.4 8.4 45.9 47.6 50.2 65 42.9 44.2 46.2 56. 57.8 60.4 80 80.0 82.6 86.5 04.6 08.0. 00 24.2 28. 4.6 62.4 67.5 76.0 25 20.6 27. 228.2 275.4 28.9 298.4 50 276.9 285.4 299.7 62. 200 48. 45.8 474.5 4 DKRCI.PD.FN0.A9.02 / 520H2207 Danfoss A/S (AC-MCI/MWA), 202-2

Material specification FIA, FIA-SS 5-40 ( / 2 - / 2 ) Danfoss M48H005_ Danfoss M48H004_ FIA, FIA-SS 5-40 ( / 2 - / 2 ) No. Part Material DIN ISO ASTM Housing Steel G20Mn5QT, 02- ------------------------------------ P285QH+QT, 0222-4 Stainless steel (FIA-SS only) 2 Gasket Fibre, Non-asbestos X5CrNi8-0 EN 0088 Cover Steel P285QH EN 0028- Stainless steel (FIA-SS only) X5CrNi8-0 EN 0088 LCC, A52 -------------------------------- LF2, A50 AISI 04 AISI 04 4 Bolts Stainless steel A2-70 A2-70 Type 08 5 Marking label Aluminium 6 element Stainless steel 7 Pressure relief (screw) Stainless steel Danfoss A/S (AC-MCI/MWA), 202-2 DKRCI.PD.FN0.A9.02 / 520H2207 5

Material specification FIA 50-200 (2-8 ) FIA 250-00 (0-2 ) 6 2 4 5 7 8 FIA 50-00 (2-2 ) No. Part Material DIN ISO ASTM Housing Steel G20Mn5QT, 02- LCC, A52 2 Gasket Fibre, Non-asbestos Cover Steel P285QH EN 0028-4 Bolts Stainless steel A2-70 A2-70 Type 08 5 Marking label Aluminium 6 element Stainless steel 7 Pressure relief (screw) Stainless steel 8* Packing washer Aluminium * pos 8 used in FIA 50-00 6 DKRCI.PD.FN0.A9.02 / 520H2207 Danfoss A/S (AC-MCI/MWA), 202-2

Connections OD T OD T Butt-weld DIN (EN 0220) 5 20 / 2 2. / 4 26.9 2. 2. 0.89.059 0.09 0.09 DIN 25 2 40 / 4 / 2.7 42.4 48. 2.6 2.6 2.6.27.669.902 0.0 0.02 0.0 50 65 2 60. 2 / 2 76. 2.9 2.9 2.7 0. 0. 80 00 4 88.9 4..2.6.50 4.50 0. 0.4 25 50 200 5 6 8 9.7 68. 29. 4.0 4.5 6. 5.50 6.6 8.6 0.6 0.8 0.25 250 00 0 2 27 2.9 6. 7. 0.75 2.75 0.25 0.28 OD T OD T Butt-weld ANSI (B 6.0 Schedule 80) ANSI 5 20 / 2 2. / 4 26.9.7 4.0 0.89.059 0.46 0.58 25 2 40 / 4 / 2.7 42.4 48. 4.6 4.9 5..27.669.902 0.8 0.9 0.20 Butt-weld ANSI (B 6.0 Schedule 40) 50 65 2 60. 2 / 2 7.0.9 5.2 2.7 2.87 0.5 0.20 80 00 4 88.9 4. 5.5 6.0.50 4.50 0.22 0.24 25 50 200 5 6 8 4. 68. 29. 6.6 7. 8.2 5.56 6.6 8.6 0.26 0.28 0.2 250 00 0 2 27 2.9 6. 7. 0.75 2.75 0.25 0.28 SOC ID T ID T L L Socket welding ANSI (B 6.) 5 20 25 2 40 / 2 2.8 / 4 27.2 / 4 / 2.9 42.7 48.8 6.0 4.6 7.2 6. 6.6 0.858.07.5.74.92 0.25 0.8 0.284 0.240 0.260 0 0.9 0.5 0.5 0.5 0.5 50 2 6.2 6.2 2.4 0.24 6 0.6 FPT Inside pipe thread FPT inside pipe thread, NPT (ANSI/ASME B.20.) 5 20 25 2 / 2 ( / 2 4 NPT) / 4 ( / 4 4 NPT) / 4 (.5 NPT) ( / 4.5 NPT) Danfoss A/S (AC-MCI/MWA), 202-2 DKRCI.PD.FN0.A9.02 / 520H2207 7

Dimensions and weights FIA 5-65 Angle-way Straight-way Angle-way size A C H F m Weight FIA 5-20 45 05 60 68. kg ( / 2 " - / 4 ").77 4. 2.6 2.68 2.4 lbs FIA 25-40 55 2 70 95.7 kg (" - / 2 ") 2.7 5.20 2.76.74.7 lbs FIA 50 60 2 77 92 2.8 kg (2") 2.6 5.20.0.62 6.2 lbs FIA 65 70 52 90 07.8 kg (2 / 2 ") 2.76 5.98.54 4.2 8.4 lbs Straight-way Valve size A C C m H E F m Weight FIA 5-20 20 99 60 20 68.4 kg ( / 2 " - / 4 ") 4.72.90 5.24 2.6 0.79 2.68. lbs FIA 25-40 55 29 77 70 26 95 2.4 kg (" - / 2 ") 6.0 5.08 6.97 2.76.02.74 5. lbs FIA 50 48 8 84 77 2 92.5 kg (2") 5.8 5.4 7.24.0.26.62 7.7 lbs FIA 65 76 65 29 90 40 07 5. kg (2 / 2 ") 6.9 6.50 8.62.54.57 4.2.7 lbs 8 DKRCI.PD.FN0.A9.02 / 520H2207 Danfoss A/S (AC-MCI/MWA), 202-2

Dimensions and weights FIA 80-00 Angle-way Straight-way Angle-way size A C H F m Weight FIA 80 90 89 29 7. kg (").54 7.44 5.08 5.24 6. lbs FIA 00 06 22 56 6.9 kg (4") 4.7 8.78 6.4 6.42 26.2 lbs FIA 25 28 268 92 90 2.2 kg (5") 5.04 0.6 7.56 7.48 46.7 lbs FIA 50 45 0 29 22 0.5 kg (6") 5.7.9 8.62 8.78 67.2 lbs FIA 200 80 72 276 280 68 kg (8") 7.09 4.65 0.87.02 50 lbs FIA 250 20 97 4 285 89 kg (0") 8.27 5.6.4.22 96. lbs FIA 00 240 458 84 40 25 kg (2") 9.45 8.0 5.2.9 275.5 lbs Straight-way size A C C m H E F m Weight FIA 80 26 204 27 29 48 8.6 kg (") 8.50 8.0 0.67 5.08.89 5.24 9 lbs FIA 00 264 256 7 56 60 6 4.9 kg (4") 0.9 0.08.27 6.4 2.6 6.42 2.8 lbs FIA 25 22 408 92 74 90 26.9 kg (5") 2.68 2.2 6.06 7.56 2.9 7.48 59. lbs FIA 50 70 70 482 29 9 22 5 kg (6") 4.57 4.57 8.98 8.62.58 8.78 2 lbs FIA 200 464 465 605 276 7 280 95 kg (8") 8.27 8. 2.82 0.87 4.6.02 209 lbs Danfoss A/S (AC-MCI/MWA), 202-2 DKRCI.PD.FN0.A9.02 / 520H2207 9

Ordering The table below is used to identify the filter required. Please note that you have to order FIA filter housing, a filter element and accessories. Example: FIA 50 D ANG + FIA-X 50 50µ + Bag = 48H056 + 48H0 + 48H50 Type Without 5 ½ FIA 5 D ANG 48H05 5 ½ FIA-SS 5 D ANG 52BAR 48H22 5 ½ FIA 5 A ANG 48H06 5 ½ FIA 5 SOC ANG 48H075 5 ½ FIA 5 FPT ANG 48H08 5 ½ FIA 5 D STR 48H085 5 ½ FIA-SS 5 D STR 52BAR 48H285 5 ½ FIA 5 A STR 48H097 5 ½ FIA 5 SOC STR 48H09 5 ½ FIA 5 FPT STR 48H5 20 ¾ FIA 20 D ANG 48H052 20 ¾ FIA-SS 20 D ANG 52BAR 48H222 20 ¾ FIA 20 A ANG 48H064 20 ¾ FIA 20 FPT ANG 48H082 20 ¾ FIA 20 SOC ANG 48H076 20 ¾ FIA 20 D STR 48H086 20 ¾ FIA-SS 20 D STR 52BAR 48H286 20 ¾ FIA 20 A STR 48H098 20 ¾ FIA 20 FPT STR 48H6 20 ¾ FIA 20 SOC STR 48H0 25 FIA 25 D ANG 48H05 25 FIA-SS 25 D ANG 52BAR 48H22 25 FIA 25 A ANG 48H065 25 FIA 25 FPT ANG 48H08 25 FIA 25 SOC ANG 48H077 25 FIA 25 D STR 48H087 25 FIA-SS 25 D STR 52BAR 48H287 25 FIA 25 A STR 48H099 25 FIA 25 FPT STR 48H7 25 FIA 25 SOC STR 48H 2 ¼ FIA 2 D ANG 48H054 2 ¼ FIA-SS 2 D ANG 52BAR 48H224 2 ¼ FIA 2 A ANG 48H066 2 ¼ FIA 2 FPT ANG 48H084 2 ¼ FIA 2 SOC ANG 48H078 2 ¼ FIA 2 D STR 48H088 2 ¼ FIA-SS 2 D STR 52BAR 48H288 2 ¼ FIA 2 A STR 48H00 2 ¼ FIA 2 FPT STR 48H8 2 ¼ FIA 2 SOC STR 48H2 40 ½ FIA 40 D ANG 48H055 40 ½ FIA-SS 40 D ANG 52BAR 48H225 40 ½ FIA 40 A ANG 48H067 40 ½ FIA 40 SOC ANG 48H079 40 ½ FIA 40 D STR 48H089 40 ½ FIA-SS 40 D STR 52BAR 48H289 40 ½ FIA 40 A STR 48H0 40 ½ FIA 40 SOC STR 48H 50 2 FIA 50 D ANG 48H056 50 2 FIA-SS 50 D ANG 52BAR 48H28 50 2 FIA 50 A ANG 48H068 50 2 FIA 50 SOC ANG 48H080 50 2 FIA 50 D STR 48H090 50 2 FIA-SS 50 D STR 52BAR 48H290 50 2 FIA 50 A STR 48H02 50 2 FIA 50 SOC STR 48H4 D A SOC FPT = Butt-weld DIN = Butt-weld ANSI = Socket welding = Inside pipe thread ANG = Angle-way STR = Straight-way 00µ 50 mesh 50µ 00 mesh 250µ 72 mesh Code number 500µ 8 mesh Pleated filter element 50µ 00 mesh Pleated filter element 250µ 72 mesh Pleated filter element 500µ 8 mesh 48H22 48H24 48H26 48H28 48H0 48H6-48H22 48H24 48H26 48H28 48H0 48H6-48H2 48H25 48H27 48H29 48H04 48H269-48H2 48H25 48H27 48H29 48H04 48H269-48H2 48H25 48H27 48H29 48H04 48H269-48H57 48H0 48H8 48H44 48H79 48H84 48H89 0 DKRCI.PD.FN0.A9.02 / 520H2207 Danfoss A/S (AC-MCI/MWA), 202-2

Ordering Type Without 65 2½ FIA 65 D ANG 48H057 65 2½ FIA-SS 65 D ANG 52BAR 48H284 65 2½ FIA 65 A ANG 48H069 65 2½ FIA 65 D STR 48H09 65 2½ FIA-SS 65 D STR 52BAR 48H29 65 2½ FIA 65 A STR 48H0 80 FIA 80 D ANG 48H058 80 FIA 80 A ANG 48H070 80 FIA 80 D STR 48H092 80 FIA 80 A STR 48H04 00 4 FIA 00 D ANG 48H059 00 4 FIA 00 A ANG 48H07 00 4 FIA 00 D STR 48H09 00 4 FIA 00 A STR 48H05 25 5 FIA 25 D ANG 48H060 25 5 FIA 25 A ANG 48H072 25 5 FIA 25 D STR 48H094 25 5 FIA 25 A STR 48H06 50 6 FIA 50 D ANG 48H06 50 6 FIA 50 A ANG 48H07 50 6 FIA 50 D STR 48H095 50 6 FIA 50 A STR 48H07 200 8 FIA 200 D ANG 48H062 200 8 FIA 200 A ANG 48H074 200 8 FIA 200 D STR 48H096 200 8 FIA 200 A STR 48H08 250 0 FIA 250 D ANG 48H7 250 0 FIA 250 A ANG 48H7 50µ 00 mesh 250µ 72 mesh Code number 500µ 8 mesh Pleated filter element 50µ 00 mesh Pleated filter element 250µ 72 mesh Pleated filter element 500µ 8 mesh 48H 48H9 48H45 48H80 48H85 48H90 48H9 48H20 48H2 48H8 48H86 48H9 48H2 48H40 48H46 48H82 48H87 48H92 48H 48H4 48H47 48H8 48H88 48H9 48H4 48H42 48H48 48H226 - - 48H5 48H4 48H49 48H297 - - 48H6 48H75 - - - - 00 2 FIA 00 A ANG 48H74 48H7 48H76 - - - - D A = Butt-weld DIN = Butt-weld ANSI ANG = Angle-way STR = Straight-way Accessories Part Accessory for Code number FIA 65-00 48H447 Magnet insert FIA 25-200 48H448 Part Accessory for Code number element µ50 with removable element µ50 for the first start up FIA 5-20 FIA 25-40 48H0 48H02 Part Accessory for Code number FIA 50 48H50 FIA 65 48H5 FIA 80 48H52 bag FIA 00 48H5 FIA 25 48H54 FIA 50 48H55 FIA 200 48H56 Part Accessory for Code number Purge valve complete 48B745 FIA 50-00 Blind nut with gasket 48H450 Danfoss A/S (AC-MCI/MWA), 202-2 DKRCI.PD.FN0.A9.02 / 520H2207

www.danfoss.com/ir 2 DKRCI.PD.FN0.A9.02 / 520H2207 Danfoss A/S (AC-MCI/MWA), 202-2