Circuit Regulating Valve STRÖMAX GF

Similar documents
4017 M HERZ Dimensions in mm

STRÖMAX-MFS Circuit Control Valve with Measuring Valves Inclined Model

1/2" /4" " /4" 1 1 /4"

HERZ-Motorised flow controler

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs

Distributor for Floor Heating Systems

HERZ-Connect 4 / Compact Connect 4 & Commissioning Centres

Valid from

Automatic balancing valves ASV-PV DN (3rd gen.)

Description. Ballorex Venturi. Versions. Benefits. Robinets manuels Balancing

Serie Ekoflux S. Flanged balancing valve. Application fields. Regulation. Ekoflux.S_GB_22/04/2015 HEATING CONDITIONING

3-port seat valves PN16 with flanged connection

2-port seat valves PN16 with flanged connection

3-Port Seat Valves with Flange, PN 6

3-Port Seat Valves with Flange, PN 10

STAF, STAF-SG. Balancing valves PN 16 and PN 25 DN

STAF-SG. ANSI flanges. Balancing valves DN

3-port seat valves PN6 with flanged connection

STAF, STAF-SG. Balancing valves PN 16 and PN 25 DN

3-port seat valves PN10 with flanged connection

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

STAF-SG. ANSI flanges. Balancing valves Size 3/4-16

Valves, controls + systems Cast iron double regulating/ commissioning valves PN 16 Hydrocontrol G

HERZ Motorised Actuator

VBF21.. Three-port slipper valves PN6. Series 02: DN40 and DN50 Series 01: DN

Static Balancing Valve

2-port ball valves with flanged connection, PN25

BUD: 3-way flanged valve, PN 6 (pn.)

VUD: 2-way flanged valve, PN 6 (pn.)

Double regulating and commissionig valves Hydrocontrol F cast iron, PN 16 Hydrocontrol FR bronze, PN 16 Hydrocontrol FS nodular cast iron, PN 25

PRESSURE RELIEF VALVE CONTROL VALVE

Ballorex Venturi 3.1 Introduction

Valves, controllers + systems Double regulating and commissioning valves Hydrocontrol F cast iron, PN 16

Combi valves PN 16 with flanged connections

3-port seat valves PN16 with flanged connection

Balancing Valves. Venturi Commissioning Valve (FODRV) & (DRV) Cu x Cu Compression DN10-DN50. BOSS TM 901SC Venturi DRV DN

BQE: 3-way flanged valve, PN 16

Materials : Cast iron

BUE: 3-way flanged valve, PN 16/10 (el.)

Hydrocontrol VFC cast iron, PN 16 Hydrocontrol VFR bronze, PN 16 Hydrocontrol VFN nodular cast iron, PN 25 Double regulating and commissioning valves

Pressure independent balancing and control valve

Materials : Cast iron or Stainless steel

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

HERZ PUMPFIX HERZ PUMPFIX. Datasheet 1 45XX XX, Issue Table of contents. Page 1. General information about HERZ PUMPFIX pump groups...

Pressure independent balancing and control valve AB-QM DN

Technote. Frese YDF-2F & YDF-20F - differential pressure control valve. Application. Benefits. Features.

Mikrotherm F. Manual Radiator Valves With presetting

Butterfly valve with ADA pneumatic actuator

TDU.3 floor distribution unit SK

Section 20. HVAC Valves & Products

Flow controller with integrated control valve (PN 16) AHQM - return and flow mounting

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

Data sheet: Wilo-Yonos MAXO 40/0,5-16

Excess pressure regulator Excess pressure regulator, straight through DN

Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

MADE OF STAINLESS... Certificate 3.1

Manual Presetting Valves LENO MSV-B

Pressure reducing valve Pressure reducing valve in straightway form DN

Materials : Cast iron or Stainless steel

FO-BV Series. Fixed-orifice balancing and control valves. Technical Data Sheet. WattsIndustries.com

Connection. k VS -Value m 3 /h

Butterfly valves PN6, PN10, PN16

Butterfly valves PN6, PN10, PN16

Flowserve TX2 Butterfly Valves Triple Offset TECHNICAL BULLETIN FCD DVENTB

Butterfly valve with ADA pneumatic actuator

Flow controller with integrated control valve (PN 16) AHQM return and flow mounting

Butterfly valves, PN6, PN10, PN16

Butterfly valves. Introduction. Made of ductile cast iron

Manual presetting valves LENO MSV-BD

AV 23 Balancing valves SETTER Inline

Product Sheet Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

Two-port seat valves with male thread, PN16

Connection. k VS -Value m 3 /h

DA 50. Differential pressure controllers Adjustable set-point

2-Port Seat Valves with Flange, PN 25

2 PIECES BALL VALVE PN63

GRINNELL MODEL CB800 CIRCUIT BALANCING VALVE INSTALLATION & SETTING HANDBOOK

CONTROL EQUIPMENT STAZ-16, STBZ-16

DN 40 to DN 150 ISO PN10/16 flanges -10 C C Max Pressure : 16 Bars Specifications : Full bore Stainless steel ball ISO 5211 mounting pad

Hydraulics in HVAC Applications

Ref Model/Ref: CAST IRON BALL VALVE PN 16 WITH THREADED HOLE FLANGES

15100 VALVES. E. Section Building Automation and Control System Guidelines

Size : Ends : Min Temperature : Max Temperature : Max Pressure : Specifications : Materials : Cast iron body

V5032. Kombi-2-plus Manual double regulating balancing valve. Product specification sheet

Pressure relief controller AFA / VFG 2(1) (PN 16, 25, 40)

2 PIECES BALL VALVE PN63

with electric actuators Feedwater control valve with pump spill back DN

Differential pressure relief controller (PN 16, 25, 40) AFPA / VFG 2(1)

DN 15 to DN 200 PN10/16 Flanges -10 C C Max Pressure : 16 Bars Specifications : Full bore Stainless steel ball ISO 5211 mounting pad

Ballorex Vario. Description. Versions. Benefits. Applications. Balancing

LUG BUTTERFLY VALVE PN10/16

VG9000 Flanged Valves

3-port seat valves, external thread, PN16

Stop valve with soft seal Free of maintenance stop valve - soft sealed (to 120 C)

3-port valves vxf42..

BOA-SuperCompact. Type Series Booklet

Overview of types. Technical data

Materials : Cast iron body EN GJL-250

Ref ALL POSITIONS CAST IRON CHECK VALVE PN16. Model/Ref:

2-Port Seat Valves with Flange, PN 25

Transcription:

Circuit Regulating Valve STRÖMAX - GF Circuit Regulating Valve for differential pressure measurement, with test points, flanged version Data sheet for GF Issue 0 GF STRÖMAX GF with test points H H D L. Hand wheel. Digital display of presetting. Upper part made of grey cast iron GJL 0. Body made of grey cast iron GJL 0. Test Points /. Plugs / Flange dimension according to EN - Order number GF Standard characteristic with linear characteristic DN L H H D 0 0 0 0 0 0 0 0 0 0 00 0 0 0 00 00 00 0 0 0 0 Dimensions in mm Order numbers 00 0 0 0 GF STRÖMAX-GF-circuit regulating valve with test points, DN 0-00 Screw-down model, grey cast iron body GJL 0 acc. EN, flange acc. EN, PN, blue enamel coating. Upper part grey cast iron GJL 0, with non-rising spindle, spindle seal by means of triple O-Ring. Presetting step is shown on the digital display. Models We reserve the right to make modifications in line with progress in engineering. Richard-Strauss-Straße A-0 Wien

Don t lift or carry the valve with the hand wheel! The valve is pre-finished ex factory delivered. To prevent the possible impurities on the seat during the storing and transportation the valve is closed. In order to avoid the fouling during the storing and transportaion the flange covering must be mounted. Storing: Temperature - bis + 0 C, humidity max. 0% Transportation Two test points 0 and presetting marker 0 are included. Test points position optional. This alignment allows the best access in all kind of installations and optimal connection of measuring devices. Test points Pipe thread /, for test points mounting Bore size 0 0 Drain Valve with handle and swivel hose connection, brass version, hose connection 0 0 has to be ordered separately. For draining systems use HERZ-boiler filling and draining cock xx. Pipe Fittings For hydraulic balancing in heating or cooling systems for isolating of manifolds, risers, heat exchangers, heating and cooling systems. Field of application Mounting position optional. The flow direction according to the arrow marked on the valve body. It is recommended installing x straight pipe diameters upstream and x straight pipe diameters downstream of the valve. Mounting Maximum operating temperature 0 C, minimum operating temperature - C Maximum operating pressure bar Hot water quality according Austrian Standard ÖNORM H and/or VDI-guideline 0 Operational data Upper part grey cast iron GJL 0 acc. EN Body grey cast iron GJL 0 acc. EN Spindle DN 0 - DN 0 brass, DN - DN 00 stainless steel Control spindle Brass / stainless steel Valve cone grey cast iron GJL 0 acc. EN / EPDM coated Counter plastic material O-Rings EPDM Materials Flow direction Ensure that the flow direction is in accordance with the arrow shown on the valve body. Constructional characteristics Mounting position The non-rising valve spindle is mounted vertically to the valve axis and consequently offers optimum accessibility and easy valve handling in every position. Seat seal The spindle seal is equipped with an tripple O-Ring. Tripple-O-Ring The spindle seal is equipped with an elastic tripple O-Ring and is guaranteed to be impermeable and offer easy handling. Seal between Upper Part and body (EPDM) The permanently elastic soft seal provides constant temperature. It is corrosion-resistant and allows minor closing pressure.

The Strömax GF Circuit regulating valve is equipped with two test points: so it is possible to measure the differential pressure by use of the proper measuring devices and to determine the flow rate accordingly. Differential pressure measurement By using ethylene glycol as antifreezer the minimum percentage is % and the maximum % allowed. Therewith the medium density is changed and so a correction factor has to be applied. measured diferential pressure value / coefficient= actual diferential pressure value Correction factors measured water quantity value x / coefficient = actual water quantity value Medium temperature correction factor Medium temperature correction factor - 0 C. 0 C. - C. 0 C.0 0 C. 0 C C. 0 C 0. 0 C. 0 C 0. These correction factors are to be applied during the measurements with HERZ differential pressure measurement devices. Interim values can be interpolated. The maximum deviation of mass flow rate to characteristic of circuit regulating valves according to VDI-guidelines. Mass flow rate tolerance The valve will be delivered in closed position. The pre- setting permits the maximally possible stroke. The handwheel mechanics are so adjusted that with closed valve the digital display indicates 0.0. Pre-adjustment Presetting. Desired presetting stage in accordance with data (Digital display on handwheel) Presetting and fixing. / of turn are the red numbers, full turn are the blue.. The presetting spindle is beneath the cover. The spindle can be adjusted with a scredriver mm. To preset turn anti clockwise up to stop. The valve is now able to close and open back to the preset position. Replace the cover on the handwheel.. The pre-setting marker ( 0) is fastened as a tag above the valve or pipe. The setting of the respective valve is marked by cutting or breaking off the teeth at the figures for full and partial turns. This permits checking and/or restoration of the original pre-setting made on the occasion of system set-up after servicing without having to rely on documentation. The setting of flowrate is achieved with a measuring device refering to the flow charts. Please see the operating instructions from the measuring device. If the valve is closed valve 0.0 is displayed on the digital display. If you have to remove the complete handwheel (turning handle, numeric wheels, baseplate) it is important to do this as following instruction:. Set the complete upper part and fastening the three allen screws and the four hexagon screws. Digital display factory setting. Close the valve clockwise.. If you see 0.0 on the digital display it is correct.. After this you can assemble the handwheel.. Fixing the attachment bolt.. Now you can preset the valve. The HERZ measuring computer has suitable couplings, 0 00, which guarantee perfect connection to the test points. Test points The two measuring valves are equipped with a soft seal and permanently fixed in the circuit control valve. Warning: Open the measuring valves only when a measuring instrument has been connected. Otherwise, hot water flowing out may cause injury! The HERZ-measuring computer is equipped with suitable couplings with O-ring seal and locking screw that permit perfect fastening on the measuring valves.

0 Pre- setting marker 0 00 Measuring device Flow Plus 00 0 Measuring device for one hand using 0 0 Drain valve / with swivel hose connection 0 0 Hose connection 0 00 Test point adaptors Accessories 0 00 Screw plug / 0 0 Test point blue 0 0 Test point red Spare parts Order No. GF DN Std char. curve kvs Lin. char. curve kvs 0 0. 0 0 0 0 0 0 00 0 00 0 00 0 kvs-value Please note: Following diagrams and settings are only for dimensioning and design from HERZ- STRÖMAX- GF valves. To check and change the pre-settings after measuring the differential pressure by working you can receive special diagrams you have to order. GMF DN - 0 STRÖMAX-GMF Circuit regulating valve, flanged version Other related products GM DN - 0 STRÖMAX GM Circuit regulating valve, screw down model, GM DN - 0 female/male GR DN - 0 STRÖMAX GR Circuit regulating valve, screw down model M DN - 0 STRÖMAX-M Cicuit regulating model, inclined model R DN - 0 STRÖMAX-M Cicuit regulating model, inclined model 0 DN - 0 STRÖMAX-FODRV AGF DN - 0 STRÖMAX- AGF Shutoff valve, flanged version DN 0-00 HERZ- Butterfly valve in semi or fully lugged version MW DN - 0 STRÖMAX-MW Cicuit regulating valve DW

STRÖMAX- GF Circuit regulating valve DN 0, PN, 0 Richard-Strauss-Straße A-0 Wien

STRÖMAX- GF Circuit regulating valve DN 0, PN, 0 Richard-Strauss-Straße A-0 Wien

STRÖMAX- GF Circuit regulating valve DN, PN, Richard-Strauss-Straße A-0 Wien

STRÖMAX- GF Circuit regulating valve DN, PN, Richard-Strauss-Straße A-0 Wien

STRÖMAX- GF Circuit regulating valve DN 0, PN, Richard-Strauss-Straße A-0 Wien

STRÖMAX- GF Circuit regulating valve DN 0, PN, Richard-Strauss-Straße A-0 Wien

STRÖMAX- GF Circuit regulating valve DN 0, PN, Richard-Strauss-Straße A-0 Wien

STRÖMAX- GF Circuit regulating valve DN 0, PN, Richard-Strauss-Straße A-0 Wien

STRÖMAX- GF Circuit regulating valve DN, PN, Richard-Strauss-Straße A-0 Wien

STRÖMAX- GF Circuit regulating valve DN, PN, Richard-Strauss-Straße A-0 Wien

STRÖMAX- GF Circuit regulating valve DN, PN, Richard-Strauss-Straße A-0 Wien

STRÖMAX- GF Circuit regulating valve DN, PN, Richard-Strauss-Straße A-0 Wien

STRÖMAX- GF Circuit regulating valve DN 00, PN,, Richard-Strauss-Straße A-0 Wien

STRÖMAX- GF Circuit regulating valve DN 0, PN,, Richard-Strauss-Straße A-0 Wien

STRÖMAX- GF Circuit regulating valve DN 00, PN,, All specifications and statements within this brochure are according to information available at the time of printing and meant for informational purpose only. reserves the right to modify and change products as well as its technical specifications and/or it functioning according to technological progress and requirements. It is understood that all images of HERZ products are symbolic representations and therefore may visually differ from the actual product. Colours may differ due to printing technology used. In case of any further questions don t hesitate to contact your closest HERZ Branch-office. Richard-Strauss-Straße A-0 Wien

Printed by Belloprint Ltd. office@belloprint.com