VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 450,0/360,0 495,0/396,0 689,46 400/ ,8 450,0/360,0 495,0/396,0 715,32

Similar documents
VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 41,8/33,4 46,0/36,8 64,02 400/ ,8 41,8/33,4 46,0/36,8 66,42

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 172,9/138,3 190,6/152,5 265,44 400/ ,8 172,9/138,3 190,6/152,5 275,4

Code: VOLVO TAD 734 GE MECC-ALTE ECO 38-1LN. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 250,0/200,0 275,0/220,0 397,4

ENGINE MAKE MODEL CONTINUOUS POWER PERKINS 2206A-E15TAG2 STAND-BY POWER

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 85,0/68,0 93,5/74,8 130,23 400/ ,8 85,0/68,0 93,5/74,8 135,12

VOLTAGE HZ PHASE COS PRP KVA/KW LTP KVA/KW AMPERAGE A

TECHNICAL SPECIFICATIONS

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE (LTP) 400/ ,8 62,3/49,9 68,6/54,9 99,17

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA

Code: VOLVO TAD 731 GE MECC-ALTE ECP 34-2L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 150,0/120,0 165,0/132,0 238,44

Code: DEUTZ BF4M 1013 FC MECC-ALTE ECP 34-1L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP)

Code: KOHLER KDI1903M MECC-ALTE ECP 28-M/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 18,9/15,2 20,8/16,6 30,07

Code: KOHLER KDW 1404 ZANARDI ATO 28-1VS/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 10,0/8,0 11,0/8,8 15,9

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 102,6/82,1 113,0/90,4 157,32 400/ ,8 102,6/82,1 113,0/90,4 163,22

1 / Genset general description

1 / Genset general description

1 / Genset general description

DGP-25 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

DGL 6 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

Standby Amper VOLTAGE

Standby Amper VOLTAGE

HFW-85 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Standard soundproofing Powered by FPT_IVECO

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

Subsidiaries: PORTUGAL POLAND GERMANY UK SINGAPORE UAE PANAMA DOMINICAN REPUBLIC ARGENTINA ANGOLA SOUTH AFRICA

GMS-015Y. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

GE.VO.360/325.SS+0_all

16 KW / 20 KVA POWERED by

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

Generating Rates SERVICE PRP STANDBY. HEAVY RANGE Container Powered by MTU

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

Generating Rates WATER-COOLED THREE PHASE 50 HZ DIESEL. ADVANCED with quality certification ISO 9001

GSW150P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Standby Amper VOLTAGE

Technical specification

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

Power kva 9,3 10 Power kw 9,3 10 Rated Speed r.p.m Standard Voltage V 240 Rated at power factor Cos Phi 1

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

GSW80P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

30 KW / 40 KVA POWERED by

GSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3

GMR - 67P 67P 09/05/2016 GMR - 067P

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GBW22P. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

Large autonomy Safety Ease of handling Silent. 18,0/14,4 20,0/16,0 Yanmar 4TNE88PG. 18,5/14,8 19,6/15,7 Deutz F3M 1011 F

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

HYW-20 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Open Skid Powered by YANMAR

Annex A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 400V (750KVA) DIESEL

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

18 KW / 18 KVA POWERED by

GSW35Y. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Open Skid Powered by SCANIA

JCB Diesel Generator Technical Specifications G45QX. Electrical. Prime

28 KW / 28 KVA POWERED by

JCB Diesel Generator Technical Specifications G331QX. Electrical. Prime

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

2000 KW / 2500 KVA POWERED by

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

APD 1650 M. Generator expert, honest advice with competitive solutions kva Diesel Generating Sets

80 KW / 100 KVA POWERED by

640 KW / 800 KVA POWERED by

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by YANMAR

JCB Diesel Generator Technical Specifications G31RX. Electrical. Prime

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

NG904PES SERIES. Power Output Ratings. kva 904 kw 723 kva 808 kw 646. Standby Power (ESP) Prime Power (PRP)

1500 KW / 1875 KVA. POWERED by TP-MT1500-T2-60. kva 1875 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

45 KW / 55 KVA POWERED by

GE.PK.022/020.SS+0_all

600 KW / 750 KVA POWERED by

HFW-350 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

130 KW / 165 KVA POWERED by

700 KVA / 550 KW POWERED by

K26M POWER 240 MONO 230 MONO 220 MONO

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

WPS350/S EP Series. Features:

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Power kva 11,5 12,4 Power kw 9,2 9,9 Rated Speed r.p.m Standard Voltage V 230/115 Rated at power factor Cos Phi 0,8

275 KW / 344 KVA. POWERED by TP-JD275-T3F-60. kva 313 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 224 Prime Power Factor 0.

1800 KW / 2250 KVA POWERED by

55 KW / 70 KVA POWERED by

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

PRAMAC GBW 45. Main features. GBW Series. Item code: SB450TPAY kw. Standby power LTP. 34 kw. Rated prime power (PRP)

Power kva 14,3 15,6 Power kw 11,4 12,5 Rated Speed r.p.m Standard Voltage V 230/115 Rated at power factor Cos Phi 0,8

Transcription:

TECHNICAL SPECIFICATIONS Model: IV-500 Gen set with manual control panel. Image for guidance purposes. (400 / 230 V) ENGINE MAKE VOLVO MODEL TAD 1345 GE CONTINUOUS POWER: (PRP Prime Power norma ISO 8528-1) 450 kva ALTERNATOR MODEL MECC-ALTE ECO 40-2SN / 4 STAND-BY POWER: (LTP Limited Time Power norma ISO 8528-1) 500 kva Amperes in the different voltages: VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/240 50 3 0,8 450,0/360,0 495,0/396,0 689,46 400/230 50 3 0,8 450,0/360,0 495,0/396,0 715,32 380/220 50 3 0,8 450,0/360,0 495,0/396,0 752,97 240/139 50 3 0,8 450,0/360,0 495,0/396,0 1192,2 230/133 50 3 0,8 450,0/360,0 495,0/396,0 1244,03 220/127 50 3 0,8 450,0/360,0 495,0/396,0 1300,58

ENGINE CHARACTERISTICS MAKE VOLVO GENERAL DATA Power PRP (kwm) Power LTP (kwm) No. cylinders Cylinder capacity (L) Diameter per stroke (mm) Compression ratio Cooling system Injection Suction Series regulator Fly wheel coupling MODEL TAD 1345 GE 388 431 6 12.78 131 x 158 18.10 LIQUID COMMON RAIL TURBO-INTERC. ELECTRONIC 1-14" Lubrication system Oil capacity (L) Oil consumption (%) Min. alarm oil pressure (bar) 36 0.04 2.20 Ventilation system Air cooling flow (m3/h) Combustion air flow (m3/h) Max. back pressure for fan (mbar) 24120 1608 0 Exhaust system Exhaust gas flow (m3/h) Exhaust back pressure (mbar) Temp. exhaust gases (ºC)) 4620 100 477 Electrical system VDC (V) Battery (Ah) Engine start-up (kw) 24 2 x 180 7 Teléfono: +34 968 380 Planet 129 Trading Phone: and Transportation +34 968 380 879 W L L Street No:4 / Gate Fax: No: +34 117 968 380 / Building 504 No:235 / Fax: Industrial +34 968 Area 380 400 / PO Box: 8359 Doha / Qatar Tel: 974 E-mail: 4498 sales@inmesol.com 7849

ALTERNATOR CHARACTERISTICS MODEL MECC-ALTE ECO 40-2SN / 4 (400 / 230 V) GENERAL DATA Power PRP (kva) Power LTP (kva) Efficiency Alt. 3/4 % Efficiency Alt. 4/4 % No. Poles Voltage regulator No. wires Insulation Xd (%) X d (%) X Degree of protection 450 495.00 94.60 94.40 4 DER-1 12 H 232.00 21.40 12.10 IP21 GENERATOR SET CONSUMPTION % POWER USED LITRES/HOUR 50% 47 75% 69 100% 92 DIMENSIONS, CAPACITIES, APPROXIMATE WEIGHT AND NOISE DIMENSIONS (MM) LENGTH WIDTH HEIGHT 4200 1600 2145 FUEL TANK (LITRES) WEIGHT (KG) 534.00 4660.00 NOISE LEVEL (db (A)) 72 @ 7 m

INMESOL GENERATOR SET GENERAL DESCRIPTION The INMESOL generator set is an electrical energy generating machine which is used in places where there is no mains supply or when there is a MAINS failure. The mobile elements, distribution belt, fan, etc., and those parts which reach high temperatures during operation, exhaust manifold, etc, include their corresponding protections, in compliance with the requirements of the Machinery Directive 2006/42. REGULATIONS The machine holds the CE marking, and the corresponding Declaration of Conformity is issued with each of them, in which it specifies that the machine complies with R.D 842/2002 Low Voltage Regulations and with the European Directives: 2006/42 on Safety in Machinery. 2006/95/CE on Electrical Safety. 2004/108/CE on Electromagnetic Compatibility. 2005/88/CE on NOISE EMISSIONS by equipment for outdoor use (for SOUNDPROOF GENERATOR SETS).

IN INDUSTRIAL RANGE / SCOPE OF SUPPLY Engine/alternator monobloc directly connected and installed via silent blocks on a frame made from high tensile electro welded steel profiles that are treated with degreasing liquids and aplicated with a phosphate coat and epoxi paint. Canopy of steel sheet sound proofed with fireproof rockwool, and treated with degreasing liquids and aplicated with a phosphate coat and epoxi paint. Fuel tank integrated in the base frame provided with fuel level jauge and fuel connections to the engine. Engine with mechanical engine driven pusher fan. Industrial silencer with -15 db(a) noise reduction and exhaust outlet tube. Residencial silencer with -35 db(a) noise reduction with exhaust tube and protection cap. Electric control cubicle with control module including protection and reading of electrical meassures engine instrumentation fuel level and engine running hours, etc. Termal and magnetic circuit breaker and termal and magnetic circuit breaker and earth fault relay. Battery charge alternator. Starter battery complete with cables to the engine and pole protection. Installation prepared for earthing spike (spike not included). Security protection for heat and moving parts as well as live electrical components. External emergency stop push button. Manual engine oil extraction pump. Self excited and auto regulated alternator. Integrated lifting hook for single point lifting with crane, gensets up to 450 kva (Except in swing-out cover model) 4 Lifting points for gen sets from 450 kva and bigger. Preparate for extended fuel tank, fully bomded for leakage protection. Base frame is prepared for trailer kit installation. Standard electronic speed governor on engines from 220 kva (LTP) and up. Horizontal outlet for hot air Street No:4 / Gate Fax: No: +34 117968 / Building 380 504 No:235 / Industrial Fax: +34 Area 968 / PO 380 Box: 400 8359

DSE 7310 MANUAL CONTROL PANEL DSE 7310 MANUAL CONTROL PANEL MANUAL CONTROL, PROTECTION AND DISTRIBUTION panel, assembled on the generator set in metal cabinet with a DSE 7310 engine protection unit. Image for guidance purposes. It has the following: 1 EMERGENCY STOP PUSHBUTTON. 2 PROTECTIONS: Magnetothermal Protection Earth Leak Protection Protection fuses for control module

DSE 7310 MANUAL CONTROL PANEL 3 DSE 7310 CONTROL and PROTECTION CENTRE. It has a digital LCD screen, which provides easy reading of the information regarding the ENGINE, ALTERNATOR and CHARGING. READINGS that can be made: ENGINE: Coolant temperature Oil pressure Turning speed (rpm) Fuel level Battery voltage Battery alternator voltage. Operating hours Number of start-ups ALTERNATOR AND CHARGE: Voltages between phases and between phases and neutral. Intensities Frequency Active Power (kw) CONTROL of the set: Reactive Power (kvar) Apparent Power (kva) Cos phi Active energy meter (kw-h) START AND STOP the set MANUALLY. Possibility of doing it AUTOMATICALLY via START ON SIGNAL. PROTECTION of the engine and alternator, with the ALARMS activated: ENGINE: Low oil pressure High coolant temperature Low and High battery Voltage Failure of the alternator to charge batteries Low fuel level. ALTERNATOR: Low and High Voltage Low and High Frequency Overload due to Intensity (A) Short-circuit Negative Phase Sequence. Power Overload (KW-kVA) Load control: 1. Connection and disconnection of artificial loads. 2. Disconnection of non-essential loads

DSE 7310 MANUAL CONTROL PANEL OTRAS OTHER CARACTERÍSTICAS: CHARACTERISTICS: The real-time clock provides an exact record of events Extensive number of configurable inputs and outputs. Configurable alarms and timers. USB connectivity Fully configurable via software and PC Modbus RTU Possibility of SMS text messages Communications Ethernet, RS 232 and RS 485 Programmer Clock with multiple maintenance events which can be configured for the optimal operation of the engine. Weekly and/ or monthly programming of up to 16 starts and stops per week.

DSE 7310 MANUAL CONTROL PANEL For OPEN sets - Three-phase generators (single phase by request): SET POWER CONT. POW. MAGNETO. PROTECTION (A) EARTH LEAK PROTECTION DISTRIBUTION 10 kva 4P, 16A (B) Mod. 16A, 300 ma 1 B. CEE 3P+N+T 16A 13 kva 4P, 20A (B) Mod. 25 A, 300 ma 1 B. CEE 3P+N+T 32A 15 kva 4P, 25A (B) Mod. 25 A, 300 ma 1 B. CEE 3P+N+T 32A 20 kva 4P, 32 A (B) 1 B. CEE 3P+N+T 32 A Mod. 32 A, 300 ma 1 B. CEE 2P+T 16 A 4P, 50 A (B) 1 B. CEE 3P+N+T 63 A 30 kva Mod. 63 A, 300 ma 1 B. CEE 3P+N+T 16 A 1 B. CEE 2P+T 16 A 4P, 63 A (B) 1 B. CEE 3P+N+T 63 A 40 kva Mod. 63 A, 300 ma 1 B. CEE 3P+N+T 16 A 1 B. CEE 2P+T 16 A 4P, 80 A (B) 1 B. CEE 3P+N+T 125 A 50 kva 1 B. CEE 3P+N+T 16 A 1 B. CEE 2P+T 16 A 4P, 100 A (B) 1 B. CEE 3P+N+T 125 A 60 kva 1 B. CEE 3P+N+T 16 A 1 B. CEE 2P+T 16 A 4P, 125 A (B) 1 B.CEE 3P+N+T 16 A 75-80 kva 1 B.SCHUKO 2P+T 16 A 3P, 160 A (B) 1 B. CEE 3P+N+T 16A 100 kva 1 B. SCHUKO 2P+T 16 A 3P, 250 A (B) 1 B. CEE 3P+N+T 16A 125-150 kva 1 B. SCHUKO 2P+T 16 A 3P, 400 A (B) 1 B. CEE 3P+N+T 16A 200-275 kva 1 B. SCHUKO 2P+T 16 A 3P, 630 A (B) 1 B. CEE 3P+N+T 16A 300-400 kva 1 B. SCHUKO 2P+T 16 A 3P, 800 A (B) 1 B. CEE 3P+N+T 16A 450 kva 1 B. SCHUKO 2P+T 16 A VOLVO 430 kva DEUTZ 3P, 800 A (B) 450-500 kva 3P, 630 A (B) 570-650 kva 3P, 1000 A (B)