Dt sheet 405054 Pge 1/7 JUMO DLOS HP Precision Pressure Trnsmitter with Switching Contcts nd Disply Appliction Hydrulic plnts Mchine nd plnt engineering Test benches Lbortory equipment Brief description The JUMO DLOS HP high-precision electronic pressure switch with nlog output is predestined for use on test benches, with lbortory equipment, nd for construction of specil mchines. These res frequently demnd precise mesurement nd configurtion dpted to the mesurement tsk. The stinless steel sensor welded to the process connection fetures high burst sfety, which is in prt s much s 5x the mesuring rnge. Consequently, the plnt is relibly protected ginst medium leks in the event of mlfunction. Defult nominl mesuring rnges of 160 nd 600 br re vilble. These cn be rescled with rtio of 1:4 llowing the user to conduct vriety of mesurement tsks with only single mesuring device. Depending on the ppliction, the following output versions re vilble: 1x PNP or 2x PNP switching outputs or 1x PNP switching output nd n nlog output signl. The process pressure is visulized by lrge nd positively-lit LCD disply. Configurtion is esy to perform either on the device itself or vi the esy-to-use setup progrm. For enhnced legibility, the cse cn be rotted by +/-160 nd the disply cn be mirror-imged by 180 during instlltion. The JUMO DLOS HP lso fetures n uto-zero function for subsequent zero point djustment. Type 405054 Block digrm Pressure Rotry encoder Rotte nd press Type 405054 Interfce Setup progrm Disply 2 4 chrcters Switching output 1 Open Collector Specil fetures Linerity 0.1 % Mesuring rnge scling 1:4 Lrge, vibrnt disply sy configurtion on the device or using the setup progrm Any instlltion position possible with rottble cse (±160 ) Avilble with flush-mounted process connection Units of mesurement cn be selected Softwre disply rottble by 180 Anlog output 0 (4) to 20 ma or 0 to 10 V Voltge supply DC 12 to 30 V Switching output 2 Open Collector
Dt sheet 405054 Pge 2/7 Technicl dt Generl informtion Reference conditions DIN 16086 nd DIN N 60770 Sensor system Thin film on metl body (piezo-resistive) Admissible lod chnges > 10 million Position Mounting orienttion Any Clibrtion position Device upright, process connection t the bottom Zero point correction Possible on-site or through setup (20 % of nominl mesuring rnge) Disply Positively-lit disply Alignment Disply rottble by 180 with softwre Cse rottble by ±160 (use supplied combined tool) Size Disply 16 mm x 26 mm, font size 7 mm, 2x 4-digit Color Stndrd opertion: mber-colored Mlfunction: mber-colored (text rr, error code 1 to 9 flshing) Setup interfce occupied: red Switching sttus disply K1, K2 Unit of mesurement br, kp, MP, psi, % Opertion On device With the control element beneth the seling screw with combintion tool or screwdriver 0.5 x 3 or Allen key f 2 Setup interfce Pin 5 of the M12 x 1 round plug Input nominl mesuring rnge Reltive pressure Nominl mesuring rnges begin t 0 br. Nominl mesuring rnge 160 600 br Overlod cpbility 320 900 br Burst pressure 800 1800 br All mesuring rnges cn be overloded up to -1 br (vcuum resistnt).
Dt sheet 405054 Pge 3/7 Output All nlog outputs in three-wire connection/switching outputs: open collector, PNP switching Anlog output Current Output 475 4 to 20 ma nd 1x PNP switching output Output 476 0 to 20 ma nd 1x PNP switching output Voltge Output 477 0 to 10 V nd 1x PNP switching output Mesuring rnge scling (turn down) 1:4 Step response time (nlog input) T90 100 ms Switching output Output 470, 475, 476, or 477 1x PNP switching output Output 471 2 PNP switching output Switching type N/C contct / N/O contct Switching function Window / hysteresis Switching point Cn be configured within nominl mesuring rnge (> relese point) Relese point Cn be configured within nominl mesuring rnge (< switching point) Hysteresis Cn be configured within nominl mesuring rnge Input ttenution 0 to 99.99 s Input dely 0 to 99.99 s Contct rting Voltge drop from U B PNP 2V Switching cpcity In 250 ma, out 1mA Switching cycles > 10 million Response time 20 ms Short-circuit proof Yes Lod check, current Pulse period 2 s; T ON 40 ms Periodic protective circuit for overcurrent f = 0.5 Hz Disply: rr3 switching output K 1, rr4 switching output K 2 Burden Current 4to20mA, three-wire R L (U B - 6.5 V) 0.022 A (Ω) 0to20mA, three-wire R L (U B - 6.5 V) 0.022 A (Ω) Voltge DC0to10V, three-wire R L 10 KΩ
Dt sheet 405054 Pge 4/7 Mechnicl fetures Process connection Mteril Stinless steel 316L Process sel The mesuring system is welded nd therefore entirely free of sels. Sensor Mteril Stinless steel 630 Cse Mteril Stinless steel 316L Threded sleeve M12 x 1 Stinless steel 316L Cse sel VMQ silicone; FDA-complint Disply PA (polymide) Seling screw of control element Mteril Aluminum 3.2315 Surfce Anodized surfce Sel VMQ silicone; FDA-complint Weight 200 g with process connection 504 () Pressure trnsmitters with process connection 521 nd 523 re supplied with externl FPM sels. Note the medium resistnce of the seling mteril! Ambient conditions Admissible tempertures Medium -25 to +100 C Ambient -25 to +75 C Ambient temperture -50 C Restricted function: only sttionry use, risk of cble brek, disply without function Storge -40 to +85 C Admissible humidity Opertion 100 % rel. humidity incl. condenstion on the device outer cse Storge 90 % rel. humidity without condenstion Admissible mechnicl lod Vibrtion resistnce 20 g, 10 to 2000 Hz Shock resistnce b 50 g for 11 ms, 100 g for 1 ms lectromgnetic comptibility Only with 4-pin connecting cble nd grounded cse! Interference emission c Clss B Interference immunityc Industril requirement Protection type d IP67 IC 60068-2-6 b IC 60068-2-27 c N 61326-2-3 d N 60529 (in mted condition with suitble counterprt) Accurcy Reltive pressure Nominl mesuring rnges begin t 0 br. Nominl mesuring rnge 160 600 br Linerity 0.1 0.1 % of the mesuring spn of the nominl mesuring rnge Accurcy t +20 C b 0.25 0.25 % of the mesuring spn of the nominl mesuring rnge Accurcy t -20 to +75 C c 0.5 0.5 % of the mesuring spn of the nominl mesuring rnge Long-term stbility d 0.2 % of the mesuring spn of the nominl mesuring rnge per yer Linerity fter limit point setting b Includes: linerity, hysteresis, repetbility, devition from mesuring rnge strt nd mesuring rnge end c Includes: linerity, hysteresis, repetbility, devition from mesuring rnge strt nd mesuring rnge end, therml influence on mesuring rnge strt nd mesuring spn d N 61298-1
Dt sheet 405054 Pge 5/7 Auxiliry energy Voltge supply U B Nominl voltge DC 24 V 0 to 20 ma, three-wire, output 476 DC 12 to 30 V 4 to 20 ma, three-wire, output 475 DC 12 to 30 V 0 to 10 V, three-wire, output 477 DC 14 to 30 V Admissible voltge supply not reched Disply: rr 5 Mximum voltge supply The specified fetures re no longer met. exceeded > DC 34 V Reverse voltge protection Yes Power consumption 45 ma without lod, 545 ma with lod 2x PNP lectricl connection Round plug M12 x 1, 4-pin, A-coded (for ssignment see "Connection digrm", pge 6) lectricl circuit SLV Residul ripple: the voltge peks must not exceed or fll below the specified voltge supply vlues! Connection digrm Output 470 Output 471 Output 475-477 1x PNP switching output 2x PNP switching outputs 1x PNP switching output + 1x nlog output 3 5 4 2 1 Voltge supply K1 L+ L- Voltge supply Voltge supply 1 L+ DC 12 to 30 V 1 L+ DC 12 to 30 V 1 L+ DC 12(14) to 30 V 3 L- GND 3 L- GND 3 L- GND Output Output Output 4 K1 Highside Open Collector mx. 250 ma 3 5 4 2 1 K1 2 K2 Highside Open Collector mx. 250 ma 2 nlog 0(4) to 20 ma/dc 0 to 10 V 2 nc 4 K1 4 K1 Highside Open Collector mx. 250 ma 5 Interfce 5 Interfce 5 Interfce K2 L+ L- 3 5 4 2 1 K1 L+ L- Color coding: M12 x 1 round plug 1 BN Brown 4 BK Blck The color coding is vlid 2 WH White 5 GY Gry for A-coded stndrd cbles only! 3 BU Blue
Dt sheet 405054 Pge 6/7 Dimensions 35 30 Ø 42 M 12 1 75 Type 405054/000-... Process connections, not flush-mounted 504 511 521 523 20 31 15 26 1/4-18 NPT G 1/4 12 A 23.5 14 B 25.5 19 1.6 15 1/4-18 NPT 10.4 0.1 Ø 19 G 1/4 1.5 12 1.6 0.1 Ø 27 2.5 14 1.6 Ø7 A = Profile sel DN G 1/4 B = Profile sel DN = f 27
Dt sheet 405054 Pge 7/7 Order detils b (1) Bsic type 405054/000 JUMO DLOS HP - Precision Pressure Trnsmitter with Switching Contcts nd Disply 405054/999 JUMO DLOS HP - Precision Pressure Trnsmitter with Switching Contcts nd Disply, Specil Design (2) Input nominl mesuring rnge 465 0 to 160 br reltive pressure 468 0 to 600 br reltive pressure (3) Output 470 1x PNP switching output 471 2 PNP switching output 475 1x PNP switching output nd 1x nlog output, 4 to 20 ma, configurble b 476 1x PNP switching output nd 1x nlog output, 0 to 20 ma, configurble 477 1x PNP switching output nd 1x nlog output, 0 to 10 V, configurble (4) Process connection 504 DIN N 837 511 1/4-18 NPT DIN N 837 521 G 1/4 DIN 3852-11 523 DIN 3852-11 (5) Process connection mteril 20 CrNi (stinless steel) (6) lectricl connection 36 Round plug M12 x 1 (7) xtr codes 000 None 100 Customer-specific defult setting (specify prmeters in plin text) 591 Choke in the pressure chnnel 624 Oil nd grese free This JUMO product is licensed under United Sttes nd Cndin ptents. Purchsers of the JUMO product outside of the United Sttes nd Cnd should dvise JUMO of ny plnned sles of products incorporting the JUMO product into the United Sttes nd Cnd. Fctory setting the nlog output cn be configured by the user. (1) (2) (3) (4) (5) (6) (7) Order code - - - - - / Order exmple 405054/000-465 - 471-521 - 20-36 / 100 Stock version Delivery within 3 working dys fter receipt of order Type Version Prt no. 405054/000-468-475-504-20-36/000 0 to 600 br rel., 1x PNP switching output nd 4 to 20 ma, 00573780 Accessories Item Prt no. Cble socket, stright, 4-pin, M12 x 1, with 2 m PVC cble 00404585 Cble socket, ngled, 4-pin, M12 x 1, with 2 m PVC cble 00409334 JUMO DLOS CD setup progrm 405050 00522384 PC interfce with USB/TTL converter 00456352 Y trnsmitter cble, 5-pin 00507861 Combintion tool 00526614 Mesuring device holder for wll nd 2" pipe 00597711 Configurtion with the setup progrm cn only tke plce in conjunction with these ccessory prts.