AL-KO HYDRAULIC STATIONS HYDRO-OPT S and AL-KO HYDRO-OPT M SMART ENERGY SAVING.
SIMPLE INGENIOUS QUALITY MAKES SAVING ENERGY A PIECE OF CAKE Whether for structural reasons or due to the quality of exhaust air: wherever supply air and exhaust air must be kept separate, a hydraulic station is necessary in terms of energy. The hydraulic station impresses with its simple, compact design and technical ingenuity. You can connect AL-KO HYDROOPT S from all sides without specialist knowledge. Simply direct the brine flow directly to the station. Operation occurs with set volume flow via the Danfoss-branded frequency inverter. No complex instrumentation and control. Factory-fitted for installation and commissioning. Without compromising quality. www.al-ko.com
BENEFITS: I Ideal price-to-performance ratio I Compact, small footprint of 0.5 m² I Can be installed from internal height of the ventilation system of 918 mm I No I&C system; controlled via brand frequency converter I Can be connected with multiple functions I Quick and easy commissioning without expert knowledge I Identical in look and feel to AL-KO AT EASY and AT FLEX 2 I 3
THE SUM OF INGENIOUS DETAILS ROBUST, INGENIOUS AND ECONOMICAL AL-KO HYDRO OPT S provides everything you need to save energy where supply air and exhaust air units are installed separately. AL-KO HYDRO OPT S is ingeniously designed. For you this means: no elaborate I&C connection, no expensive skilled personnel, no complex maintenance. I Compact design I All models have the same outer dimensions I Can be installed in the ventilation system from an internal height of 918 mm I Flexible planning of the installation location I Runs with set volume flow thanks to the Danfoss-branded frequency converter I Works without complex instrumentation and control system I External control via 0-10 V setpoint signal possible I Simple commissioning without specialist personnel www.al-ko.com
I Rapid inspection and commissioning I Display the brine flow by pressing the handle I Multifunctional connection options from front, back, top and bottom I Complete decoupling of the air conditioning and ventilation system as needed by simply moving a lever I Secure screw connection of all components I Quick and easy maintenance TECHNICAL DATA Model Media volume flow Connections dp tot. vol min dp tot. vol max Pump D/380-415 YV Danfoss FU 102 frequency converter from vol min to vol max Exhaust air DN (IG) Supply air DN (IG) kpa max. * kpa max. * P2 (in kw) Rated current (A) kw S 0.5 0.35 m³/h 0.55 m³/h 20 20 275 248 0.37 1.00 1.1 S 1.5 0.56 m³/h 1.50 m³/h 20 20 415 235 0.37 1.00 1.1 S 3.5 1.51 m³/h 3.50 m³/h 32 25 593 347 1.1 2.50 1.1 S 6.5 3.51 m³/h 6.50 m³/h 40 32 488 307 1.5 3.15 1.5 S 11 6.51 m³/h 11.0 m³/h 50 40 500 322 2.2 4.45 2.2 4 I 5
THE PERFECT SOLUTION FOR EVERY NEED AND AL-KO HYDROOPT M is the simply ingenious solution if you need a hydraulic station in the region of 0.35 to 11 m³/h that is simple to operate and install and that works reliably with the desired volume flow. AL-KO HYDROOPT M is the right choice if you need a hydraulic station that dynamically and autonomously optimises the brine flow rate and thus the efficiency. (Fig. right) www.al-ko.com
AL-KO HYDROOPT M TECHNICAL DATA Model Media volume flow Connections from vol min to vol max Exhaust air DN (IG) Supply air DN (IG) M 2 0.5 m³/h 1.9 m³/h 32 32 M 5 2.0 m³/h 4.9 m³/h 40 40 M 10 5.0 m³/h 9.9 m³/h 50 50 M 15 10.0 m³/h 14.9 m³/h 65 65 M 25 15.0 m³/h 25.0 m³/h 80 80 COMPARISON OF AL-KO HYDRO OPT S AND AL-KO HYDRO OPT M Feature AL-KO HYDRO OPT S AL-KO HYDRO OPT M Number of supply air units 1 1 Number of exhaust air units 1 3 Control system Integrated in frequency converter (FC) Switch cabinet with controller and FC Power control with pump and valve Power control dependent on air volume Externally via central ventilation control system Control via separate pressure sensor on the supply air fan Enabling and trouble signal Control 0-10 V System pressure monitoring Shutdown Warning and shutdown Anti-frosting control system Bus connection Modbus RTU, extra Bacnet MSTP card Extra cards Bacnet IP, Modbus RTU, LON Pump Controllable, with air bleed valve Controllable, with blockage protection and air bleed valve. Optional dual pump Feed and return temperature indicator Flow rate measurement Mechanical Electrical Temperature display and antifreeze warning in feed Pressure gauge Dirt filter Expansion vessel and safety valve Filling and draining device 6 I 7
Figures show configuration examples which are not available in every market. Please ask your AL-KO advisor. AL-KO THERM GMBH Ventilation and Air-Conditioning Technology Hauptstraße 248 250 89343 Jettingen-Scheppach Germany Tel. +49 8225 39-0 Fax +49 8225 39-2113 klima.technik@al-ko.de www.al-ko.com Provided by your AL-KO partner: Subject to modifications in response to technical developments. No liability accepted for mistakes and printing errors. As of 10/2015