CFU. Compact Filter Unit. hyprofiltration.com/cfu

Similar documents
Filter Cart. hyprofiltration.com/fc

FSL. High Viscosity Filtration Systems. hyprofiltration.com/fsl

LF(M) High Viscosity Filter Assemblies. hyprofiltration.com/lf

LF(M) High Viscosity Filter Assemblies. hyprofiltration.com/lf

PFH. High Pressure In-line Filter Assemblies. hyprofiltration.com/pfh

HY-PRO FILTRATION. FSL Filter Unit Flow rate up to 22 gpm (83 lpm)

HY-PRO FILTRATION. FSL Filter Unit Flow rate up to 22 gpm (83 lpm)

LF/LFM - Low Pressure High Flow Assemblies LF flow rate to 560 lpm, 150 gpm / LFM flow rate to lpm, 4500 gpm.

FCL Filter Cart Flow rate up to 22 gpm (82 lpm)

Portable Filter Carts and Kidney Loop Systems

FLUID HANDLING: Drum Filter Cart

FLUID HANDLING: Drum Filter Cart

Fluid Handling: Panel Unit

Off-Line Filtration OFF-LINE FILTRATION

Portable Filter Carts Models 5MF and 10MF

PORTABLE LUBRICATION MANAGEMENT CATALOG. ForFluids.com

Hydraulic & Lubrication Filters

LT Series Lubricant Management System (LT-LMS)

Series RFL In-Line Filter

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

[You may download this article at: ]

MATERIALS CARTRIDGES PRESSURES VALUES TESTS CARRIED OUT ON FILTER ELEMENTS

SPIN-ON FILTERS & ELEMENTS

HIGH PRESSURE FILTERS DFFX Series Reverse Flow Differential Pressure Optimized Filters 6090 psi up to 160 gpm

Low Pressure Filters

MEDIUM PRESSURE FILTERS

OFFLINE FILTRATION SYSTEMS

FPK04 Max Flow: 100 gpm (379 lpm)

Fluid Handling Products. Fluid Handling a proactive approach to contamination control. Portable Filtration. Dedicated Filtration

Portable Filter Carts 10MFP with Moduflow

HYDRAULIC AND LUBE OIL FILTERS RFM Series

LOW PRESSURE FILTERS RFM Series In-Tank Return Line Filters 145 psi up to 224 gpm

Spin-on filter according to Bosch Rexroth standard: Type 50 SL 30 to 80D. Features. Contents. RE Edition:

IXON PUMPS. Innovative Fluid Transfer, Filtration, and Tank Cleaning Systems

Filtering elements differential collapsing pressure tested in compliance with ISO 2941:

LOW PRESSURE FILTERS RF Series In-tank / Inline Filters 360 psi up to 400 gpm

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

FILTER ELEMENTS. Overview of Elements PN# / / FIL

10 Hydraulic Filters

HIGH PRESSURE FILTERS Series HF2P

Series RFLD Duplex In-Line Filter

PT Series Tank Top Filters

PRODUCT BROCHURE. Innovative Fluid Transfer, Filtration, and Tank Cleaning Systems

Portable Filter Carts. Models 5MFP & 10MFP with Modufl ow and Intelli-Cart

HIGH PRESSURE FILTERS

PLC-3000 zfa01. Portable Fluid Analysis. Global Filtration Technology

Low & High Pressure ProGuard Filters

Low Pressure Filters

HMK05/25 DURAMAX Spin-Ons

10 Hydraulic Filters

HIGH PRESSURE FILTERS

Duplex Pressure Filters

Fluid Cooling Industrial COLW Series

Low Pressure Filters. Low Pressure Filters LOW PRESSURE FILTERS

IXON PUMPS. Innovative Fluid Transfer, Filtration, and Tank Cleaning Systems

FPK02 In-Line Cartridge Filters

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS DF/DFF 1500 Series Inline Filters 6090 psi up to 250 gpm

HPK04 Max Flow: 120 gpm (454 lpm)

Medium Pressure Filters

Filter solutions for Danfoss PAH, APP and CLP pumps

HIGH PRESSURE FILTERS

Portable Hydraulic Filtration Systems. Guardian. MAX 15 I/min - 2 bar. Portable filtration systems

P.C. Priority Flow Control Valve Series J02D3. General Description

Guardian Portable Filtration System

Moduflow. ILP and RFP Low Pressure Filters. Series

HIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm

Spin-on filter according to Bosch Rexroth standard. Type 7 SL ; 7 SLS Features. Contents. RE Edition: Replaces: 01.

Ultipleat SRT Filters

Medium Pressure Filters

Pneumatic High-Viscosity Filtration System Instruction Manual

12CS/50CS Series Coreless Medium Pressure Filters

Mobile Hydraulic Pumps T6G, T67G, T6ZC. Denison Vane Technology, fixed displacement

J Series Filters HIGH PRESSURE FILTERS. J88 Mini In-Line (Replaceable Filter) J85 Tee-Type. J82 Mini In-Line. J83 In-Line

Your Partner in Filtration

VARNA Products. >80psi / 5.5bar 30-80psi / bar >3ft / 1m 3/4" (-12) 250 f / 120 c Oil Viscosity Range cst cst

Inline filter with filter element according to DIN 24550

Line filter with filter element according to DIN 24550

DVX-DUPL DFS DVF-64, DVF-65 DVX. CLEANDiesel Vessels, Housings & Skid Systems DVF-64, DVF-65, DVX, DV, DVF, DFS

Inline filter with filter element according to DIN 24550

OUT (419) (610)

TTF/BGTS Series. Return In-Tank Filters. Global Filtration Technology

Block mounting filter, for lateral flange-mounting

FPG-MDS PRESSURE FILTERS MATERIALS PRESSURE BYPASS VALVE WORKING TEMPERATURE COMPATIBILITY (ISO 2943) HYDRAULIC DIAGRAM.

HIGH PERFORMANCE FILTERS INDUSTRIAL HYDRAULIC AND LUBRICATION APPLICATIONS

Moduflow Series IL2/RF2/CF2 Low Pressure Filters

BGT Series. Low Pressure Filters

Coolers. OK Series. Air Cooled Oil Coolers Hydraulic Symbol OK 1-11 OKF Cooling Systems Catalog. Applications

PRPM2-A. = 5.5 Nm (4.1 lb.-ft.) (qual. 8.8 Nm (6.5 lb.-ft.) for socket cap screws. = 50 Nm (36.9 lb.-ft.) for cartridges

12CS/50CS Series. Coreless Spin-on Filters

Inline filter with filter element according to DIN 24550

Oil Solutions. TTF/BGTS Series Return In-Tank Filters. Global Filtration Technology. Filtration.

Off-Line Filtration Unit

Low Pressure Filters

SPIN-ON FILTER - LOW PRESSURE LINE

PRESSURE FILTERS FOR MODULAR STACKING. Series DF-Z Pressures to 4500 psi Flows to 10 gpm APPLICATION PRODUCT FEATURES FILTER ELEMENTS

The Leader in Visual Lubrication Systems

Deister Machine Company, Inc. Heavy Duty System Saver Operating Instructions

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

Transcription:

CFU Compact Filter Unit Bigger isn t always better. The Compact Filter Unit provides you with the best filtration at a size you can take anywhere. Tried and true, the CFU is the ultimate filtration system in power and mobility. And with easy to change Spin-On elements or heavy duty MF3s, you can rest easy knowing your filtration will always exceed your expectations.

Small size, huge results. Designed specifically for limited space operations, the CFU maximizes power in a minimal package. Use the ergonomic handle to hoist the CFU to provide filtration directly within turbine nacelles or filter straight from the barrel to take out contaminants before they can ever reach your equipment. The first stage of success. Staged filtration allows a range of media selections for particulate and water removal to deliver ISO Codes right on target. Choose from six element configurations to get the perfect CFU for your toughest contamination problems. Media matters. DFE rated filter elements stay true to efficiency ratings and ensure the highest level of particulate capture and retention capabilities. And with media options down to β2.5 [C] = 1000 you can be sure contamination stays exactly where you want it: out of your fluid. Redefines standard filtration. Knowledge of your system is the ultimate tool in the fight against contamination. With upstream and downstream sample ports located on every machine, the standard CFUs are anything but standard. Different by design. Built from lightweight aluminum and engineered for portability, the CFU is perfectly designed to filter new fluids during transfer and top-off bulk oil before use. For fluids already in service, use the CFU to flush them through the high efficiency elements for unparalleled levels of fluid cleanliness. Completely customizable. Every CFU can be specifically tailored to the job at hand so you get the perfect solution to suit your needs. With a variety of flow rates and power options, even the ability to color coordinate each CFU to your existing safety standards, the possibilities are endless for what you can do with the CFU.

CFU Quick Guide CFUN model shown (2x MF3 in series) Closed ergonomic handle for easy lifting/hoisting Gear pump CFU inlet Filter assembly ΔP gauge Inlet sample port Outlet sample port CFU outlet MF3 Filter Assembly 8 bowl with HP60L8 series filter element Electric motor Lightweight aluminum frame Non-slip rubber feet CFUL (2x HP409 in series) CFUD (2x HP75 in parallel) CFUS (2x HP75 in series)

Filter Sizing Guidelines Filter Sizing Guidelines and Viscosity Conversion Effective filter sizing requires consideration of flow rate, viscosity (operating and cold start), fluid type and degree of filtration. When properly sized, bypass during cold start can be avoided/minimized and optimum element efficiency and life achieved. The filter assembly differential pressure values provided for sizing differ for each media code, and assume 32 cst (150 SUS) viscosity and 0.86 fluid specific gravity. Use the following steps to calculate clean element assembly pressure drop. Calculate ΔP coefficient for actual viscosity Using Saybolt Universal Seconds (SUS) Actual Operating Viscosity 1 (SUS) Actual Specific Gravity ΔP Coefficient = X 150 0.86 Using Centistokes (cst) ΔP Coefficient = Actual Operating Viscosity 1 (cst) Actual Specific Gravity X 32 0.86 Calculate actual clean filter assembly ΔP at both operating and cold start viscosity Actual Assembly Clean ΔP = Flow Rate X ΔP Coefficient (from calculation above) X Assembly ΔP Factor (from sizing table) Sizing recommendations to optimize performance and permit future flexibility To avoid or minimize bypass during cold start the actual assembly clean ΔP calculation should be repeated for start-up conditions if cold starts are frequent. Actual assembly clean ΔP should not exceed 10% of bypass P gauge/indicator set point at normal operating viscosity. If suitable assembly size is approaching the upper limit of the recommended flow rate at the desired degree of filtration consider increasing the assembly to the next larger size if a finer degree of filtration might be preferred in the future. This practice allows the future flexibility to enhance fluid cleanliness without compromising clean ΔP or filter element life. Once a suitable filter assembly size is determined consider increasing the assembly to the next larger size to optimize filter element life and avoid bypass during cold start. When using water glycol or other specified synthetics we recommend increasing the filter assembly by 1~2 sizes.

CFU Filter Sizing Guidelines MF3 Options ΔP Factors 1 Series Length Units Media 1M 3M 6M 12M 16M 25M **W MF3 L8 psid/gpm 0.324 0.252 0.206 0.156 0.151 0.143 0.026 bard/lpm 0.006 0.005 0.004 0.003 0.003 0.003 0.000 S75-76 Options ΔP Factors 1 Series Length Units Media 1M 3M 6M 12M 16M 25M **W S75 L8 psid/gpm 0.183 0.155 0.120 0.107 0.105 0.101 0.018 bard/lpm 0.003 0.003 0.002 0.002 0.002 0.002 0.000 S75D L8 psid/gpm 0.092 0.077 0.060 0.054 0.053 0.051 0.009 bard/lpm 0.002 0.001 0.001 0.001 0.001 0.001 0.000 Series Length Units Media 3A 6A 12A 25A 3C 10C 25C S75 L8 psid/gpm 0.172 0.133 0.119 0.113 0.247 0.161 0.157 bard/lpm 0.003 0.002 0.002 0.002 0.005 0.003 0.003 S75D L8 psid/gpm 0.086 0.067 0.060 0.056 0.124 0.081 0.078 bard/lpm 0.002 0.001 0.001 0.001 0.002 0.001 0.001 S409 Options ΔP Factors 1 Series Length Units Media 1M 3M 6M 10M 25M 25A **W S409 L9 psid/gpm 0.296 0.250 0.194 0.174 0.170 0.187 0.031 bard/lpm 0.005 0.005 0.004 0.003 0.003 0.003 0.001 1 Max flow rates and ΔP factors assume υ = 150 SUS, 32 cst. See filter assembly sizing guideline for viscosity conversion formula.

CFU Specifications Dimensions 1 Connections Operating Temperature ΔP Indicator Trigger Filter Assembly Bypass Materials of Construction Electric Motor Electric Connection Pump Pneumatic Option Air Consumption Media Description Replacement Elements Height 21 (54 cm) Inlet ¾ male JIC with 37 flare Fluid Temperature 30 F to 225 F (0 C to 105 C) Length 21 (54 cm) Outlet ½ male JIC with 37 flare 22 psi (1.5 bar). Consult factory for other options. 25 psid (1.7 bard). Consult factory for other options. Frame Powder coated aluminum TEFC, 56C frame ½ hp, 1450-1750 RPM Filter Assembly Aluminum head 15 (4.6 m) cord included installed on machine. 2 Width 12 (31 cm) Hoses Reinforced synthetic Positive displacement gear pump with relief valve. Maximum pressure on pump inlet 15 psi (1 bar). Consult factory for higher pressures. ~15 cfm @ 60 psi 3 M G8 Dualglass, our latest generation of DFE rated, high performance glass media for all hydraulic & lubrication fluids. βx [C] = 1000 (βx = 200) Weight 47 lbs (21 kg) Hoses ¾ x 8 ft (2.4 m) suction female JIC or BSPP swivel ½ x 8 ft (2.4 m) discharge female JIC or BSPP swivel Ambient Temperature -4 F to 104 F (-20C to 40C) A G8 Dualglass high performance media combined with water removal scrim. βx [C] = 1000 (βx = 200) Wands Stainless steel W Stainless steel wire mesh media βx [C] = 2 (βx = 2) Element Bypass Valve Nylon To determine replacement elements, use corresponding codes from your equipment part number: Model CFUD CFUH CFUL CFUM CFUN CFUS Filter Element Part Number HP75L8 [Media Selection Code] [Seal Code] HP75L8 [Media Selection Code] [Seal Code] HP409L9 [Media Selection Code] [Seal Code] HP60L8 [Media Selection Code] [Seal Code] HP60L8 [Media Selection Code] [Seal Code] HP75L8 [Media Selection Code] [Seal Code] Example HP75L8 12MB HP75L8 3ME-WS HP409L 9 40WV HP60L8 16MB HP60L8 6AV HP75L8 25MV Viscosity Max viscosity rated for 200 cst. 4 Fluid Compatibility Hazardous Environment Options Petroleum and mineral based fluids (standard). For specified synthetics contact factory for compatibility with fluorocarbon seal option. For phosphate ester (P9) or skydrol fluid (S9) compatibility select fluid compatibility from special options. Select pneumatic powered unit (Power Option 00) or explosion proof NEC Article 501, Class 1, Division 1, Group C+D. Call for IEC, Atex or other requirements. If Explosion Proof option (X--) selected, no electrical cord will be included. 1 Dimensions are approximations taken from base model and will vary according to options chosen. 2 Selecting pneumatic power option removes electric cord. 3 Air consumption values are estimated maximums and will vary with regulator setting. 4 When sized and installed appropriately. Contact factory for applications above 200 cst for sizing requirements.

CFU Part Number Builder CFU - - Model Flow Rate Power Options Hose Connection Special Options Media 1 Media 2 Seal Model Filter Assemblies Filter Elements D H 1 L M 1 N S 1 x S75D Spin-On filter assembly 1 x S75 Spin-On filter assembly 2 x S409 Spin-On filter assemblies 1 x MF3 cartridge housing 2 x MF3 cartridge housings 2 x S75 Spin-On filter assemblies 2 x HP75L8-*** filter elements in parallel flow 1 x HP75L8-*** filter element 2 x HP409L9-*** filter elements in series flow 1 x HP60L8-*** filter element 2 x HP60L8-*** filter elements in series flow 2 x HP75L8-*** filter elements in series flow Flow Rate 2 05 1 2 5 0.5 gpm (1.7 lpm) 1 gpm (3.7 lpm) 2 gpm (7.5 lpm) 5 gpm (18.9 lpm) Power Options Contact factory for options not listed 60 Hz, 1750 RPM 50 Hz, 1450 RPM Pneumatic 12 22 120 V ac, 1P 208-230 V ac, 1P 11 21 110 V ac, 1P 220 V ac, 1P 00 Pneumatically driven air motor & PD pump. FRL & flow meter included. Explosion proof - Class 1, Division 1, Group C+D per NEC 501 Ready for outdoor use X 3 Add X prefix to power option listed above. Not available with (00) Pneumatic Option. Hose Connection G S W Female BSPP swivel hose ends, no wands Female JIC swivel hose ends, no wands Female JIC swivel hose ends, with wands Special Options B C G 3 J M Complete filter bypass line CE marked for machinery safety directive 2006/42/EC Spill retention pan with fork guides (industrial coated steel) Add pressure gauge between pump & filter assembly Total system flow meter (120 cst max) N O 3 P9 4 S9 5 Z PM-1 ready (plumbing only) On-board PM-1 particle monitor & clean oil indicator light Phosphate ester fluid compatibility modification Skydrol fluid compatibility modification On site start-up training Media Selection G8 Dualglass G8 Dualglass + water removal Stainless wire mesh 1M 3M 6M β2.5 [C] = 1000, β1 = 200 β5 [C] = 1000, β3 = 200 β7 [C] = 1000, β6 = 200 3A 6A 12A 6 β5 [C] = 1000, β3 = 200 β7 [C] = 1000, β6 = 200 β12 [C] = 1000, β12 = 200 25W 40W 74W 25μ nominal 40μ nominal 74μ nominal 12M 6 16M 25M β12 [C] = 1000, β12 = 200 β17 [C] = 1000, β17 = 200 β22 [C] = 1000, β25 = 200 25A β22 [C] = 1000, β25 = 200 149W 149μ nominal Seals B V E-WS 7 Nitrile (Buna) Fluorocarbon EPR seals + stainless steel support mesh 1 When selected, omit Media 2 option from part number builder. 2 Nominal flow rates at 60 Hz motor speeds. 3 Significant size/weight increase when selected. Contact factory for specifications. 4 When selected, must be paired with Seal option V. Contact factory for more information or assistance in fluid compatibility. 5 When selected, must be paired with Seal option E-WS. Contact factory for more information or assistance in fluid compatibility. 6 When Model L selected, use 10M or 10A for respective media code in place of 12M or 12A. 7 Only available in 3M media for HP75L8 series elements.

Filtration starts with the filter. Lower ISO Codes: Lower Total Cost of Ownership Hy-Pro filter elements deliver lower operating ISO Codes so you know your fluids are always clean, meaning lower total cost of ownership and reducing element consumption, downtime, repairs, and efficiency losses. Advanced Media Options DFE glass media maintaining efficiency to β0.7[c] > 1000, Dualglass + water removal media to remove free and emulsified water, stainless wire mesh for coarse filtration applications, and Dynafuzz stainless fiber media for EHC and aerospace applications. DFE Rated Filter Elements DFE is Hy-Pro s proprietary testing process which extends ISO 16889 Multi Pass testing to include real world, dynamic conditions and ensures that our filter elements excel in your most demanding hydraulic and lube applications. Delivery in days, not weeks From a massive inventory of ready-toship filter elements to flexible manufacturing processes, Hy-Pro is equipped for incredibly fast response time to ensure you get your filter elements and protect your uptime. Upgrade Your Filtration Keeping fluids clean results in big reliability gains and upgrading to Hy-Pro filter elements is the first step to clean oil and improved efficiency. More than just filtration Purchasing Hy-Pro filter elements means you not only get the best filters, you also get the unrivaled support, training, knowledge and expertise of the Hy-Pro team working shoulder-to-shoulder with you to eliminate fluid contamination. Want to find out more? Get in touch. hyprofiltration.com info@hyprofiltration.com +1 317 849 3535 2016 Hy-Pro Corporation. All rights reserved. MK TLITFCE-CFU-022117-BC