WARNING. Mounting Instructions D103996X012 May DVC6200/DVC2000 Digital Valve Controller on Linear Actuator

Similar documents
WARNING. Mounting Instructions D103998X012 June DVC6200/DVC2000 Digital Valve Controller Linear Actuator Side Mount

WARNING. Mounting Instructions D103778X012 June 2013

Fisher FIELDVUE DVC6000 Digital Valve Controller Dimensions

Fisher FIELDVUE DVC6200 Digital Valve Controller / Magnet Assembly Dimensions

Zero Point Calibration HART Communicating Fisher FIELDVUE DVC6200 Digital Valve Controllers

Fisher 2052 Diaphragm Rotary Actuator

Fisher FIELDVUE DVC6200 Series Hazardous Area Approval Nameplates

M Series Manual Handwheel Gear Actuator

Fisher 1B and 1BR Constant Pressure Pump Governor Actuators

Fisher RSS Lined Globe Valve

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Fisher 656 Diaphragm Actuator

Baumann Sanitary Control Valve

Fisher EZ-Overtravel (EZ-OVT) Valve Trim

M Series Manual Handwheel Gear Actuator

Fisher 3024C Diaphragm Actuator

DVG/AF Variable Geometry Desuperheater

Fisher 377 Trip Valve

Baumann Mikroseal Control Valve

Fisher 644 and 645 Differential Pressure Pump Governors

Fisher VBL Volume Booster

Baumann Corrosion Resistant Control Valve

Fisher RSS Lined Globe Valve

Baumann Way Control Valve

Baumann Sanitary Angle Control Valve

Baumann Little Scotty Bronze Control Valve

Fisher VBL Volume Booster

Fisher 2052 Diaphragm Rotary Actuator

Baumann Sanitary Diaphragm Angle & In-Line Control Valve Instructions

Fisher 685 Piston Actuator

Fisher SS-263 Volume Booster

Fisher ENVIRO SEAL Packing System for Rotary Valves

Fisherr V150S Slurry Vee-Ball Control Valve NPS 3 through 12

Fisher TBX Hydro Plug Fixture

Fisher CVX Hydro Plug Fixture

Baumann Flexsleev Sanitary Control Valve

Baumann 24000F Wafer Control Valve

Type 644 and 645 Differential Pressure Pump Governors

Fisherr 2052 Diaphragm Rotary Actuator

Monitoring Health of External Solenoid Valve (SOV) with FIELDVUE DVC6200 SIS Digital Valve Controllers

Baumann Sanitary Angle Control Valve

Baumann Sanitary Diaphragm Angle and Inline Control Valve

Fisher 2625 and 2625NS Volume Boosters

Fisher 249 Cageless Displacer Sensors

Baumann 24000CVF Carbon & 24000SVF Stainless Steel Flanged Valve Instructions

Fisher D2T FloPro Control Valve

Fisher 1077 Manual Handwheel Rotary Actuator

Fisher eplug complete Rotary Control Valve and Actuator Package

Fisher EU and EW Valves NPS 12 through 24 x 20

Baumann Sanitary Control Valve

Fisher 685 Piston Actuator

Fisher 8590 High-Performance Butterfly Valve

Fisher 3024C Diaphragm Actuator

Fisherr 1051 and 1052 Diaphragm Rotary Actuators

Fisher 546 Electro Pneumatic Transducer

Fisher 377 Trip Valve

Baumann 24000C Carbon Steel Little Scotty Control Valve Instructions

Fisher POSI-SEAL A31A Cryogenic High Performance Butterfly Valve

Fisher POSI-SEAL A81 Rotary Valve (Obsolete Product)

Fisher 480 Series Yokeless Piston Actuators

Fisher 377 Trip Valve

Fisher 685SE and 685SR Piston Actuator

Baumann 24000S Stainless Steel Control Valve

Fisher D4 Control Valve Assembly

Fisher 657NS Diaphragm Actuators Size 40, 45, 70, and 80

Fisher 2052 Diaphragm Rotary Actuator

Fisher CCV-N Fuel Gas Control Valve

Fisher 1061 Pneumatic Piston Rotary Actuator with Style F & G Mounting Adaptations

Fisher 2625, 2625SST, and 2625NS Volume Boosters

Fisher V500 Rotary Control Valve

Baumann Pneumatic Actuators

Fisher 2625, 2625SST, and 2625NS Volume Boosters

Baumann Series Flexsleev Control Valve Instructions

Design D and DA Control Valves

Fisher DSV High Performance Digester Switching Valve

Baumann 24000CVF Carbon & 24000SVF Stainless Steel Flanged Control Valves

Fisher DSV High Performance Digester Switching Valve (Obsolete Product)

Fisher 685SE and 685SR Piston Actuators

Fisher WhisperFlo Aerodynamic Noise Attenuation Trim

Fisher V150S Slurry Vee-Ball Control Valve

Fisher CV500 Rotary Control Valve

Fisher 657 and 667 Diaphragm Actuators

Fisher 667NS Diaphragm Actuators Size 40, 45, 70, and 80

Fisher L3 Pneumatic Level Controller

L3 Pneumatic Level Controller

Bettis M11 Manual Hydraulic Override System Operating Instructions for HD, T, and G Series Pneumatic and Hydraulic Actuators

Fisher Multi-Port Flow Selector Valve

Fisher CAV4 Control Valve

Fisher V250 Ball Valve

Fisher A31A Cryogenic High Performance Butterfly Valve

Fisher 3660 and 3661 Positioners

Fisher 8580 Rotary Valve

Fisher 9500 Butterfly Control Valve

Fisher A31D Double-Flange High-Performance Butterfly Valve

Fisher L2e Electric Level Controller

Fisherr easy -et Cryogenic Sliding -Stem Control Valves

Fisher A31D Double-Flange High-Performance Butterfly Valve

Fisher i2p 100 Electro Pneumatic Transducer

Connectors for Diagnostic Testing with the FlowScanner Valve Diagnostic System

Fisher Whisper Trim III Cages

Transcription:

Use these instructions to mount a FIELDVUE to a. WARNING Avoid personal injury or property damage from sudden release of process pressure or bursting of parts. Before performing any maintenance operations: Always wear protective clothing, gloves, and eyewear. Do not remove the actuator from the valve while the valve is still pressurized. Disconnect any operating lines providing air pressure, electric power, or a control signal to the actuator. Be sure the actuator cannot suddenly open or close the valve. Use bypass valves or completely shut off the process to isolate the valve from process pressure. Relieve process pressure from both sides of the valve. Vent the pneumatic actuator loading pressure and relieve any actuator spring precompression. Use lock-out procedures to be sure that the above measures stay in effect while you work on the equipment. Check with your process or safety engineer for any additional measures that must be taken to protect against process media. 1. Isolate the control valve from the process line pressure and release pressure from both sides of the valve body. Shut off all pressure lines to the actuator, releasing all pressure from the actuator. Use lock-out procedures to be sure that the above measures stay in effect while you work on the equipment. 2. Attach connector arm assembly to stem block using provided fasteners (including spacers and stud bolts, if applicable). The visual aids in this document are for general reference representation only. Refer to the appropriate actuator instruction manual for actuator installation, operation, maintenance, and parts identification as this manual may or may not include all components shown for kit installation. 1

For fork-style connector arms remove the nuts and indicator disk from the stem. Place the fork-style extension arm flush with the bottom of the stem block onto the stem. Reattach the indicator disk and nuts. 3. Loosely attach array to extension arm using provided fasteners. (Array not included with kit) 2

4. Attach extension arm with array assembly to connector arm. 5. Attach mounting plate to actuator using provided hardware (including stud bolts, spacers, and L-brackets, if applicable). 3

6. Attach aligning template to mounting plate. Adjust height of array until the middle line of the aligning template is level with the corresponding line of the array relative to stem block position. ***Care needs to be taken to ensure that line the index marks on the array do not move outside of the center index mark on the alignment template*** 4

7. Attach insert assembly into the magnet housing slot on the back of the device using the provided 3m adhesive strip. 8. Remove aligning template. Attach device to mounting bracket using provided fasteners. 5

9. Attach remote mount air filter regulator (if applicable). Final Assembly 6

Air Filter Regulator DVC6200 Shield Alignment Template Extension Arm Spacer Connector Arm Insert Assembly U-Bracket Common Mounting Bracket Linear Feedback Array DVC2000 Mounting Plate 7

Neither Emerson, Emerson Process Management, Fisher, nor any of their affiliated entities assumes responsibility for the selection, use and maintenance of any product. Responsibility for the selection, use and maintenance of any product remains with the purchaser and end user. Fisherand FIELDVUE are marks owned by Fisher Controls International LLC, a member of the Emerson Process Management business unit of Emerson Electric Co. Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson Process Management Marshalltown, Iowa 50158 USA Sorocaba, 18087 Brazil Chatham, Kent ME4 4QZ UK Dubai, United Arab Emirates Singapore 128461 Singapore 2014 Fisher Controls International LLC. All right reserved. 8