Air Pressure Sensing Switch with Adjustable Set Point Range. Dimensions in Inches (Millimeters)

Similar documents
Powers TM Controls SW 141 Differential Static Airflow Switches

Differential Pressure Switch

60T Series Snap-Action Temperature Controls

Distributed By: M&M Control Service, Inc PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE #

Differential pressure switch for monitoring air pressure in HVAC systems.

60T Series Snap-Action Temperature Controls

Pneumatic Controls. Pneumatic Controls Sections

POWERS Controls No. 4 Pneumatic Damper Actuator

North American 1599 Electro-Hydraulic Gas Shutoff Valve Bulletin 1599

A25 Series Warm Air Control with Manual Reset

Pressure Switch SOR. Sifter ready to run: Adequate pressure to switch. Sifter not ready to run: Either loss of air pressure, or open guard.

Bourdon Tube Pressure Switches

P10 Series Low Range Pressure Controls

E. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment

ATP-2040 Electric Damper Actuator/Transmitter

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

SD-1250 and SD-1600 Series Smoke Dampers

P70, P72, and P170 Controls for Low Pressure Applications

Our new range of electromechanical pressure switches with fixed setting are compact, light and easy to install.

POWERS TM CONTROLS LC Pneumatic Damper Actuator

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

WARNING. Diode Package The Murphy diode package ( ) is designed to allow the fuel shutoff valve to be used with dual Magneto Ignition systems.

37T Series Moisture Resistant Temperature Controls

2006 Series Geared Rotary Limit Switches

AD-1251 Probe with Differential Pressure Transducer

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

Introduction to Johnson Controls Dampers

Powers TM Controls Three-way Electro-pneumatic (EP) Valve Model 2

FSAF24(-S) US, FSAF120(-S) US

100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE

SECTION METERS AND GAGES FOR PLUMBING PIPING

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*

Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with General Purpose, Watertight or Explosion-Proof Enclosures

M100F Incremental Motor Actuator R81F Interface Board

System 350 P352AB Electronic Pressure Control Series

Installation and Operation Instructions DLP Series

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

MC-351, 421, 431, MC-4311

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

Introduction. System Components

The installation and maintenance of this product must be done under the supervision of an experienced

Compact Low Pressure Sensor

Powers TM Controls SW 134 Pressure Electric Switch (Adjustable Differential)

Dissolved Oxygen Measurement System with Air Blast Cleaner

Pressure Control Type KPU

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

58T Series. Adjustable Temperature Controls. Adjustable Temperature Controls

Zone Valves and Parts (Honeywell)

Laboratory Exhaust Air Terminal

SECTION AIR TERMINAL UNITS

Instructions for Installation, Operation, Care and Maintenance

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

LF Series Spring Return Direct Coupled Actuator

The IAQ50 Air Damper/Monitor Installation and Maintenance Manual

Pressure Independent Control Valve Applications for Building Automation, Temperature Controls, and HVAC Two-Way Chilled Water Hot Water

Pressure Switch with Gauge for Pressure

RM-1200 Slim Round Control Damper

MS Application. Features. Proportional Valve Actuator General Instructions

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

VA-4233-GGx Series Electric Valve Actuators

Fan Powered Low Profile Variable Volume Terminal Units

Laboratory Exhaust Air Terminal

V-SENSOR LOW AIR VELOCITY SENSOR

Shock/Vibration Control Switches

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

TotalPac 3 Firecyle III Wet pipe Remote controlled system

ECLIPSE TURBO BLOWERS SERIES SMJ

SECTION 4.05 FUEL SYSTEM MAINTENANCE F18/H24 AND L36/P48 ENGINES

POWERS Controls. Technical Instructions Document No P25 AP December 3, No. 6 Pneumatic Damper Actuator.

P70, P72 and P170 Series Controls for High Pressure Applications

AV-8020 Series Floating Control Actuated Valve

Pressure Controls type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Damper Actuator Installation

50H Z VERSION. WindJet Air Knife Packages. Deliver superior blowing and drying performance in a complete, customizable package.

AP/UP, AP/MIL Series Magnetic Circuit Protectors

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit: Mid-West Instrument

P20, P21 Series Air Conditioning Limit Controls

MA-5200 Series MA-5300 Series

Powers TM Controls EA 338 Electronic Actuator

UNITED ELECTRIC 100 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches Adjustable Ranges 30 Vac to 5000 PSI, -180 to 650 o F

OpenAir Electronic Damper Actuators GLB Series Enhanced Non-spring Return Rotary

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC

Torque min. 35 in-lb, for control of air dampers

Powers Controls No. 4 Pneumatic Damper Actuator

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

T-1001 TYPE 1001 I/P & E/P TRANSDUCERS

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

VAV Terminal Unit Control Package

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

FOR USE IN SOLUTION AIR HANDLING UNITS

Differential Pressure Switch QBM81-

Actuators & Positioners Pneumatic Actuators Series UP1/2/3/4/5/6

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 123

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.

Transcription:

Cleveland Controls Division of UniControl Inc. Model AFS 222 Air Pressure Sensing Switch with Adjustable Set Point Range Application The Model AFS-222 is a general purpose proving switch designed for HVAC and Energy Management applications. It may be used to sense positive, negative, or differential air pressure. General Description & Operation The plated housing contains a diaphragm, a calibration spring and a snap-acting SPDT switch.the sample connections located on each side of the diaphragm accept ¼" OD metallic tubing via the integral compression ferrule and nut. An enclosure cover guards against accidental contact with the live switch terminal screws and the set point adjusting screw. The enclosure cover will accept a ½" conduit connection. Mounting (see Figure 1) Select a mounting location which is free from vibration. The AFS-222 (Figure 1) Distributed by: Dimensions in Inches (Millimeters) must be mounted with the diaphragm in any vertical plane in order to obtain the lowest specified operating set point. Avoid mounting with the sample line connections in the "up" position. Surface mount via the two 3 /16" diameter holes in the integral mounting bracket. The mounting holes are 3-7 /8" apart. Air Sampling Connection (see Figure 2) The AFS-222 is designed to accept firm-wall sample lines of ¼" OD tubing by means of ferrule and nut compression connections. For sample lines of up to 10 feet, ¼" OD tubing is acceptable. For lines up to 20 feet, use ¼" ID tubing. For lines up to 60 feet, use ½" ID tubing. A ¼" OD adapter, suitable for slip-on flexible tubing is available: order part number 18311.Locate the sampling probe a minimum of 1.5 duct diameters downstream from the air source. Install the sampling probe as close to the center of the airstream as possible. Refer to Figure 2 to identify the high pressure inlet (H) and the low pressure inlet (L). Select one of the five application options listed below (on page 2), and connect the sample lines as recommended. (Figure 2) Building Controls Connection Inc 755 Center Street, Unit 7 * Lewiston, NY 14092 Tel: (716) 754-2672 Fax: (716) 754-7384 Bulletin AFS222.05 1

(Figure 3) (Figure 4) POSITIVE PRESSURE ONLY: Connect the sample line to inlet H; inlet L remains open to the atmosphere. NEGATIVE PRESSURE ONLY: Connect the sample line to inlet L; inlet H remains open to the atmosphere. TWO NEGATIVE SAMPLES: Connect the higher negative sample to inlet L. Connect the lower negative sample to inlet H. TWO POSITIVE SAMPLES: Connect the higher positive sample to inlet H. Connect the lower positive sample to inlet L. ONE POSITIVE AND ONE NEGA- TIVE SAMPLE: Connect the positive sample to inlet H. Connect the negative sample to inlet L. Electrical Connections (see Figure 3) Before pressure is applied to the diaphragm, the switch contacts will be in the normally closed (NC) position.the snap switch has screw top terminals with cup washers. Wire alarm and control applications as shown in Figure 4. Field Adjustment The adjustment range of an AFS-222 Air Switch is 0.05 ±.02" w.c. to 12.0" w.c.. To adjust the set point, t urn the adjusting screw counterclockwise until motion has stopped. Next, turn the adjusting screw 4 complete turns in a clockwise direction to engage the spring. From this point, the next ten turns will be used for the actual calibration. Each full turn represents approximately 1.2" w.c. Please note: To properly calibrate an air switch, a digital manometer or other measuring device should be used to confirm the actual set point. Specifications Model AFS-222 Air Flow Switch Mounting Position: Mount with the diaphragm in any vertical plane. Set Point Range: 0.05 ± 0.02" w.c. to 12.0"w.c. Field Adjustable Operate Range : 0.07"w.c. to 12.0" w.c. Field Adjustable Release Range : 0.04"w.c. to 11.2" w.c. Approximate Switching Differential: Progressive, increasing from 0.02± 0.01 "w.c. at minimum set point to approximately 0.8 " w.c. at maximum set point. Measured Media: Air, or combustion by-products that will not degrade silicon. Maximum Pressure: ½ psi (0.03 bar) Operating Temperature Range: -40F to 180F (-40 to 82C) Life: 100,000 cycles minimum at 1/2 psi maximum pressure each cycle and at maximum rated electrical load. Electrical Rating: 300 VA pilot duty at 115 to 277 VAC, 15 amps noninductive to 277 VAC, 60 Hz. Contact Arrangement: SPDT Electrical Connections: Screw-type terminals with cup washers. Conduit Opening: 7 /8" diameter opening accepts ½" conduit. Sample Line Connectors: Male, externally threaded 7 /16" 24 UNS 2A thread, complete with nuts and selfaligning ferrules. Sample Line Connections: Connectors will accept ¼" OD rigid or semi-rigid tubing. Approval: UL, FM, CSA Shipping Weight: 1.2 lbs. Location of Sample Lines for Typical Applications Accessories P/N 18311 Slip-on ¼" OD Tubing Adapter, suitable for slipping on flexible plastic tubing. Sample line probes. Orifice plugs (pulsation dampers). Pressure Conversion Table 1" H 2 O = 0.0361 lbs./sq. in. or 0.0735 in. mercury 1" Hg. = 0.491 lbs./sq. in. or 13.6 in. water 1 psi = 27.7 in. water or 2.036 in. mercury AFS-222 Sensing Switches are manufactured by Cleveland Controls Div. of UniControl Inc. Bulletin AFS222.05

Cleveland Controls Division of UniControl Inc. Model AFS 262 Air Pressure Sensing Switch with Adjustable Set Point Range Application The Model AFS-262 is a general purpose proving switch designed for HVAC and Energy Management applications. It may be used to sense positive, negative, or differential air pressure. General Description & Operation The plated housing contains a diaphragm, a calibration spring and a snap-acting SPDT switch.the sample connections located on each side of the diaphragm accept ¼" OD metallic tubing via the integral compression ferrule and nut. An enclosure cover guards against accidental contact with the live switch terminal screws and the set point adjusting screw. The enclosure cover will accept a ½" conduit connection. Mounting (see Figure 1) Select a mounting location which is free from vibration. The AFS-262 (Figure 1) Distributed by: Dimensions in Inches (Millimeters) must be mounted with the diaphragm in any vertical plane in order to obtain the lowest specified operating set point. Avoid mounting with the sample line connections in the "up" position. Surface mount via the two 3 /16" diameter holes in the integral mounting bracket. The mounting holes are 3-7 /8" apart. Air Sampling Connection (see Figure 2) The AFS-262 is designed to accept firm-wall sample lines of ¼" OD tubing by means of ferrule and nut compression connections. For sample lines of up to 10 feet, ¼" OD tubing is acceptable. For lines up to 20 feet, use ¼" ID tubing. For lines up to 60 feet, use ½" ID tubing. A ¼" OD adapter, suitable for slip-on flexible tubing is available: order part number 18311.Locate the sampling probe a minimum of 1.5 duct diameters downstream from the air source. Install the sampling probe as close to the center of the airstream as possible. Refer to Figure 2 to identify the high pressure inlet (H) and the low pressure inlet (L). Select one of the five application options listed below (on page 2), and connect the sample lines as recommended. (Figure 2) Building Controls Connection Inc 755 Center Street Unit 7 * Lewiston, NY 14092 Tel: (716) 754-2672 Fax: (716) 754-7384 Bulletin AFS262.05 1

(Figure 3) (Figure 4) POSITIVE PRESSURE ONLY: Connect the sample line to inlet H; inlet L remains open to the atmosphere. NEGATIVE PRESSURE ONLY: Connect the sample line to inlet L; inlet H remains open to the atmosphere. TWO NEGATIVE SAMPLES: Connect the higher negative sample to inlet L. Connect the lower negative sample to inlet H. TWO POSITIVE SAMPLES: Connect the higher positive sample to inlet H. Connect the lower positive sample to inlet L. ONE POSITIVE AND ONE NEGA- TIVE SAMPLE: Connect the positive sample to inlet H. Connect the negative sample to inlet L. Electrical Connections (see Figure 3) Before pressure is applied to the diaphragm, the switch contacts will be in the normally closed (NC) position.the snap switch has screw top terminals with cup washers. Wire alarm and control applications as shown in Figure 4. Field Adjustment The adjustment range of an AFS-262 Air Switch is 0.05 ±.02" w.c. to 2.0" w.c.. To adjust the set point, t urn the adjusting screw counterclockwise until motion has stopped. Next, turn the adjusting screw 4 complete turns in a clockwise direction to engage the spring. From this point, the next ten turns will be used for the actual calibration. Each full turn represents approximately 0.2" w.c. Please note: To properly calibrate an air switch, a digital manometer or other measuring device should be used to confirm the actual set point. Specifications Model AFS-262 Air Flow Switch Mounting Position: Mount with the diaphragm in any vertical plane. Set Point Range: 0.05 ± 0.02" w.c. to 2.0"w.c. Field Adjustable Operate Range : 0.07"w.c. to 2.0" w.c. Field Adjustable Release Range : 0.04"w.c. to 1.9" w.c. Approximate Switching Differential: Progressive, increasing from 0.02± 0.01 "w.c. at minimum set point to approximately 0.1 " w.c. at maximum set point. Measured Media: Air, or combustion by-products that will not degrade silicone. Maximum Pressure: ½ psi (0.03 bar) Operating Temperature Range: -40F to 180F (-40 to 82C) Life: 100,000 cycles minimum at 1/2 psi maximum pressure each cycle and at maximum rated electrical load. Electrical Rating: 300 VA pilot duty at 115 to 277 VAC, 15 amps noninductive to 277 VAC, 60 Hz. Contact Arrangement: SPDT Electrical Connections: Screw-type terminals with cup washers. Conduit Opening: 7 /8" diameter opening accepts ½" conduit. Sample Line Connectors: Male, externally threaded 7 /16" 24 UNS 2A thread, complete with nuts and selfaligning ferrules. Sample Line Connections: Connectors will accept ¼" OD rigid or semi-rigid tubing. Approval: UL, FM, CSA, CE Shipping Weight: 1.2 lbs. Location of Sample Lines for Typical Applications Accessories P/N 18311 Slip-on ¼" OD Tubing Adapter, suitable for slipping on flexible plastic tubing. Sample line probes. Orifice plugs (pulsation dampers). Pressure Conversion Table 1" H 2 O = 0.0361 lbs./sq. in. or 0.0735 in. mercury 1" Hg. = 0.491 lbs./sq. in. or 13.6 in. water 1 psi = 27.7 in. water or 2.036 in. mercury AFS-262 Sensing Switches are manufactured by Cleveland Controls Div. of UniControl Inc. Bulletin AFS262.05 2

Cleveland Controls Division of UniControl Inc. Model AFS 460 ADJUSTABLE SET POINT AIR PRESSURE SENSING SWITCH WITH MANUAL RESET APPLICATION The Model AFS-460 is a general purpose proving switch designed to require manual operator reset following actuation. It can be used to sense positive, negative, or differential air pressure in HVAC and Energy Management applications which require operator interface. General Description & Operation The plated housing contains a diaphragm, a calibration spring and a snap-acting SPST NC switch with manual reset button. The sample connections located on each side of the diaphragm accept 0.25" OD metallic tubing via the integral compression ferrule and nut. An enclosure cover protects the operator from accidental contact with the live switch terminal screws and the set point adjusting screw. The enclosure cover accepts a 0.5" conduit connection. MOUNTING (SEE FIGURE 1) Select a mounting location which is free from vibration. The AFS-460 must be mounted with the diaphragm in any vertical plane in order to obtain the lowest specified operating set point. Avoid mounting with the sample line connections in the "up" position. Surface mount via the two 3/16" diameter holes in the integral mounting bracket. The mounting holes are 3 7/8" apart. (Figure 1) AIR SAMPLING CONNECTION (SEE FIGURE 2) The AFS-460 is designed to accept firmwall sample lines of ¼" OD tubing by means of ferrule and nut compression connections. An optional ¼" adapter, suitable for slip-on flexible tubing is available: order part number 18311. For sample lines of up to 10 feet, ¼" OD tubing is acceptable. For lines up to 20 feet, use ¼" ID tubing. For lines up to 60 feet, use ½" ID tubing. Locate the sampling probe a minimum of 1.5 duct diameters downstream from the air source. Install the sampling probe as close to the center of the airstream as possible. Refer to Figure 2 to identify the high pressure inlet (H) and the low pressure inlet (L). Select one of the five application options listed on page 2, and connect the sample lines as recommended. POSITIVE PRESSURE ONLY: Connect the sample line to inlet H; inlet L remains open to the atmosphere. NEGATIVE PRESSURE ONLY: Connect the sample line to inlet L; inlet H remains open to the atmosphere. TWO NEGATIVE SAMPLES: Connect the higher negative sample to inlet L. Connect the lower negative sample to inlet H. TWO POSITIVE SAMPLES: Connect the higher positive sample to inlet H. Connect the lower positive sample to inlet L. ONE POSITIVE AND ONE NEGATIVE SAMPLE: Connect the positive sample to inlet H. Connect the negative sample to inlet L. Bulletin AFS460.06 Cleveland Controls DIVISION OF UNICONTROL INC. 1111 Brookpark Rd Cleveland OH 44109 Tel: 216-398-0330 Fax: 216-398-8558 Email:saleshvac@unicontrolinc.com Web page: http://www.clevelandcontrols.com Are you reading a FAX or a COPY of this bulletin? DOWNLOAD the fullcolor PDF version of this and other literature at our website!

(Figure 2) (Figure 3) (Figure 4) ELECTRICAL CONNECTIONS (SEE FIGURE 3) Before pressure is applied to the diaphragm, the switch contacts will be in the normally closed (NC) position. The snap switch has screw top terminals with cup washers. Wire alarm and control applications as shown in Figure 4. FIELD ADJUSTMENT The adjustment range of an AFS-460 Air Switch is 0.4" ± 0.02" w.c. to 12.0" w.c. To adjust the set point, turn the adjusting screw counterclockwise until motion has stopped. Next, turn the adjusting screw four complete turns in a clockwise direction to engage the spring. From this point, the next ten turns will be used for the actual calibration. Each full turn represents approximately 1.16" w.c. Please note: To properly calibrate an air switch, a digital manometer or other measuring device should be used to confirm the actual set point. SPECIFICATIONS MODEL AFS-460 AIR PRESSURE SENSING SWITCH WITH MANUAL RESET FEATURE Mounting Position (in order to meet lowest operating specifications): Mount with the diaphragm in any vertical plane. Set Point Range: 0.40 ± 0.06"w.c. to 12.0"w.c. Field Adjustable Operate Range : 0.46"w.c. to 12.0" w.c. Field Adjustable Release Range : 0.46"w.c. to 11.2" w.c. Approximate Switch Differential: Progressive, increasing from approximately 0.06± 0.01"w.c. at minimum set point, to approximately 0.8"w.c. at maximum set point. Measured Media: Air, or combustion by-products that will not degrade silicone. Maximum Pressure: ½ psi (0.03 bar) Life: Exceeds UL-recognized mechanical endurance test of 6,000 cycles minimum at 0.5 psi maximum pressure each cycle and at maximum electrical load. Electrical Rating: @ 60 Hz. 15 amp 125, 250, or 277 VAC ¼ hp 125 V AC, ½Hp 250 VAC, ½ amp 125 V DC, ¼ amp 250 V DC. Contact Arrangement: SPST NC (manual reset). Electrical Connections: Screw top terminals with cup washers. Conduit Opening: 7/8" diameter opening accepts ½" conduit. Sample Line Connectors: Male, externally threaded 7/16" 24 UNS 2A thread, complete with nuts and selfaligning ferrules. Sample Line Connections: Connectors will accept ¼" OD rigid or semi-rigid tubing. Approval and Recognition: UL, CSA, CE. Shipping Weight: 1.2 lbs. Accessories: P/N 18311 Slip-on ¼" OD Tubing Adapter, suitable for slipping on flexible plastic tubing. Sample line probes. Orifice plugs (pulsation dampers). Nominal Dimensions in Inches (Millimeters)

APPLICATION Bulletin AFS460DSS.03 Cleveland Controls Model Division of UniControl Inc. AFS-460-DSS The Model AFS-460 DSS is a general purpose airflow proving switch designed for 120 VAC HVAC and Energy Management applications where dual manual reset switches with SPST contacts are needed. It may be used to sense positive, negative, or differential air pressure. GENERAL DESCRIPTION & OPERATION The plated housing contains a diaphragm, a calibration spring, and 2 snap-acting switches with a single manual reset button. The sample connections located on each side of the diaphragm accept.25" (6.35 mm) OD tubing via the integral compression ferrule and nut. An enclosure cover guards against accidental contact with the live switch terminal screws and the set point adjusting screw. The enclosure cover accepts two 0.5" (12.7 mm) conduit connections. The manual reset button is located on the top surface of the enclosure cover. MOUNTING (SEE FIGURE 1) Select a mounting location which is free from vibration. The AFS-460 DSS must be mounted with the diaphragm in any vertical plane in order to obtain the lowest specified operating set point. Avoid (Figure 1) ADJUSTABLE SET POINT AIR PRESSURE SENSING SWITCH WITH DUAL MANUAL RESET Cleveland Controls DIVISION OF UNICONTROL INC. 1111 Brookpark Rd Cleveland OH 44109 mounting with the sample line connections in the "up" position. Surface mount via the two 3/16" (4.75 mm) diameter holes in the integral mounting bracket. The mounting holes are 3-7/8" (98.4 mm) apart. AIR SAMPLING CONNECTION (SEE FIGURE 2) The AFS-460 DSS is designed to accept firm-wall sample lines of ¼" (6.35 mm) OD tubing by means of ferrule and nut compression connections. An optional ¼" (6.35 mm) adapter, suitable for slip-on flexible tubing is available. For sample lines of up to 10 feet (3.05 metres), ¼" (6.35 mm) OD tubing is acceptable. For lines up to 20 feet (6.1 metres), use ¼" (6.35 mm) ID tubing. For lines up to 60 feet (18.3 metres), use ½" (12.7 mm) ID tubing. Locate the sampling probe a minimum of 1.5 duct diameters downstream from the air source. Install the sampling Tel: 216-398-0330 Fax: 216-398-8558 Email:saleshvac@unicontrolinc.com Web page: http://www.clevelandcontrols.com probe as close to the center of the airstream as possible. Refer to Figure 2 to identify the high pressure inlet (H), and the low pressure inlet (L). Select one of the five application options listed below, and connect the sample lines as recommended.positive PRESSURE ONLY: Connect the sample line to inlet H; inlet L remains open to the atmosphere. NEGATIVE PRESSURE ONLY: Connect the sample line to inlet L; inlet H remains open to the atmosphere. TWO NEGATIVE SAMPLES: Connect the higher negative sample to inlet L. Connect the lower negative sample to inlet H. TWO POSITIVE SAMPLES: Connect the higher positive sample to inlet H. Connect the lower positive sample to inlet L. ONE POSITIVE AND ONE NEGATIVE SAMPLE: Connect the positive sample to inlet H. Connect the negative sample to inlet L. Are you reading a FAX or a COPY of this bulletin? DOWNLOAD the fullcolor PDF version of this and other literature at our website!

ELECTRICAL CONNECTIONS (SEE FIG. 3) Before pressure is applied to the diaphragm, the snap switch contacts will be in the normally closed (NC) position as shown in Fig. 3. The snap switches have screw top terminals with cup washers. Wire alarm and control applications as shown in Fig. 4. FIELD ADJUSTMENT: LEAD & LAG SNAP SWITCHES (SEE FIG. 4) The AFS-460-DSS Manual Reset Air Switch has a lead snap switch adjustment of 1.25" w.c. to 12.0" w.c. (31.8 mm w.c. to 305 mm w.c.) The set point adjusting screw is used to adjust the set point of the lead snap switch (Switch A, in Fig. 4). The lag snap switch (Switch B, in Fig. 4) operates after the lead snap switch at progressively increasing set point increments as indicated in Table 1, below. Note: if simultaneous operation of Switch A and Switch B is required, use Model AFS-460-136 or AFS-460-137. To adjust the set point of Switch A: Turn the adjusting screw counterclockwise until motion has stopped. Next, turn the adjusting screw four complete turns in a clockwise direction to engage the spring. From this point, the next ten turns will be used for the actual calibration. Each full turn represents approximately 1.0" w.c. (25.4 mm w.c.). Please note: To properly calibrate an air switch, a digital manometer or other measuring device should be used to confirm the actual set point. Nominal Dimensions in Inches (Millimeters) (Figure 2) (Figure 3) (Figure 4) SPECIFICATIONS MODEL AFS-460-DSS AIR PRESSURE SENSING SWITCH WITH MANUAL RESET & DUAL SPST-NC CONTACT ARRANGEMENT Mounting Position (in order to meet lowest operating specifications): Mount with the diaphragm in any vertical plane. Set Point Range: 1.25 ± 0.06"w.c. to 12.0"w.c. (31.8mm ±1.52mm w.c. to 305 mm w.c.) Field Adjustable Operate Range : 1.31"w.c. to 12.0" w.c. Field Adjustable Release Range : 1.31"w.c. to 11.2" w.c. Approximate Switch Differential: Progressive, increasing from approximately 0.06± 0.01"w.c. at minimum set point, to approximately 0.8"w.c. at maximum set point. Measured Media: Air, or combustion byproducts that will not degrade silicone. Maximum Pressure: ½ psi (0.03 bar; 3.45 kpa) Life: Exceeds UL-recognized mechanical endurance test of 6,000 cycles minimum at 0.5 psi (0.03 bar, 3.45 kpa) maximum pressure each cycle and at maximum electrical load. Electrical Rating: @ 60 Hz. 15 amp 125, 250, or 277 v AC ¼ hp 125 v AC, ½Hp 250 VAC, ½ amp 125 v DC, ¼ amp 250 v DC. 0.5 VA @ 24 v AC, 50/60 Hz. Contact Arrangement: 2 SPST NC (manual reset). Electrical Connections: Screw top terminals with cup washers. Conduit Opening: 7/8" diameter opening accepts ½" conduit. Sample Line Connectors: Male, externally threaded 7/16" 24 UNS 2A thread, complete with nuts and self-aligning ferrules. Sample Line Connections: Connectors will accept ¼" (6.35mm) OD rigid or semi-rigid tubing. Approval and Recognition: UL & CSA approved; CE pending. Shipping Weight: 1.2 lbs. TABLE 1 Lead Switch A Lag Switch B Set Point Set Point 1.25" - 3.00" w.c. ( 31.8-76.2 mm w.c.) 3.00" - 6.00" w.c. (76.2-152.4 mm w.c.) up to 5% after Switch A up to 10% after Switch A 6.00" - 9.00" w.c. (152.4-229 mm w.c.) 9.00-12.00" w.c. (229-305 mm w.c.) up to 15% after Switch A up to 35% after Switch A

Cleveland Controls Division of UniControl Inc. FOR AIR PRESSURE SENSING SWITCHES Sensing Probes Static Pressure (Aspiration) Probes Total Pressure (Impact) Probes Part Number Barbed End Dimension B Part Number Smooth OD Dimension B Dimension A Part Number Barbed End Dimension B Part Number Smooth OD Dimension B Dimension A 1.5 1.0 21397 1.75 21397-112 2.0.5 21116 1.25 21116-112 3.5 1.0 21398 1.75 21398-112 4.0.5 21117 1.25 21117-112 5.5 1.0 21399 1.75 21399-112 6.0.5 21118 1.25 21118-112 7.5 1.0 21400 1.75 21400-112 8.0.5 21119 1.25 21119-112 1.5 1.0 21401 1.75 21401-112 2.0.5 21120 1.25 21120-112 3.5 1.0 21402 1.75 21402-112 4.0.5 21121 1.25 21121-112 5.5 1.0 21403 1.75 21403-112 6.0.5 21122 1.25 21122-112 7.5 1.0 21404 1.75 21404-112 8.0.5 21123 1.25 21123-112 10.0.5 28527 1.25 28527-112 12.0.5 28528 1.25 28528-112 Bulletin AFS05.04 Cleveland Controls DIVISION OF UNICONTROL INC. Are you reading a FAX or a COPY of this bulletin? DOWNLOAD the fullcolor PDF version of this and other literature at our website!

RECOMMENDED PROBE LOCATIONS: 1. Position 5 to 8 diameters downstream from elbows, obstructions, or significant change in duct area. 2. Insert probe into duct perdendicular to airstream so that: Aspiration (static) probe tip opens parallel with airstream. Impact (total pressure) probe tip opens directly into the airstream. TYPICAL APPLICATIONS (SEE FIGS. 1-6): 1. Positive static pressure increases as the filter gets dirty. 2. Differential across filter changes as filter gets dirty. 3. Flow is reduced as filter gets dirty. 4. Fan operation or true air flow with little or no static pressure. 5. Negative pressure increases as the filter gets dirty. 6. Fan operation and true air flow: varying amounts of static pressure. Probes must be perpendicular to air flow.