Automotive Mobile LPSDR SDRAM

Similar documents
Mobile Low-Power SDR SDRAM

Mobile SDRAM AVM121632S- 32M X 16 bit AVM123216S- 16M X 32 bit

t WR = 2 CLK A2 Notes:

Notes: Clock Frequency (MHz) Target t RCD- t RP-CL t RCD (ns) t RP (ns) CL (ns) -6A

Notes: Clock Frequency (MHz) Target t RCD- t RP-CL t RCD (ns) t RP (ns) CL (ns) -6A

SDR SDRAM. MT48LC16M4A2 4 Meg x 4 x 4 Banks MT48LC8M8A2 2 Meg x 8 x 4 Banks MT48LC4M16A2 1 Meg x 16 x 4 Banks. Features. 64Mb: x4, x8, x16 SDRAM

SDR SDRAM. MT48LC8M8A2 2 Meg x 8 x 4 Banks MT48LC4M16A2 1 Meg x 16 x 4 Banks. Features. 64Mb: x8, x16 SDRAM. Features

SDR SDRAM. MT48LC2M32B2 512K x 32 x 4 Banks. Features. 64Mb: x32 SDRAM. Features

Notes: Clock Frequency (MHz) Target t RCD- t RP-CL t RCD (ns) t RP (ns) CL (ns) -6A E

Notes: Clock Frequency (MHz) Target t RCD- t RP-CL t RCD (ns) t RP (ns) CL (ns) A

SDR SDRAM. MT48LC32M4A2 8 Meg x 4 x 4 Banks MT48LC16M8A2 4 Meg x 8 x 4 Banks MT48LC8M16A2 2 Meg x 16 x 4 Banks. Features. 128Mb: x4, x8, x16 SDRAM

SYNCHRONOUS DRAM. 128Mb: x32 SDRAM. MT48LC4M32B2-1 Meg x 32 x 4 banks

Notes: Clock Frequency (MHz) Target t RCD- t RP-CL t RCD (ns) t RP (ns) CL (ns) -6A E

SDRAM AS4SD8M Mb: 8 Meg x 16 SDRAM Synchronous DRAM Memory. PIN ASSIGNMENT (Top View)

Notes: 1K A[9:0] Hold

DQ0 NC DQ1 DQ0 DQ2 DQ3 DQ Speed Grade

Notes: Frequency -7E 143 MHz 5.4ns 1.5ns 0.8ns MHz 5.4ns 1.5ns 0.8ns -7E 133 MHz 5.4ns 1.5ns 0.8ns MHz 6ns 1.5ns 0.

- DQ0 - NC DQ1 - NC - NC DQ0 - NC DQ2 DQ1 DQ CONFIGURATION. None SPEED GRADE

- - DQ0 NC DQ1 DQ0 DQ2 - NC DQ1 DQ3 NC - NC

AVS64( )L

- DQ0 - NC DQ1 - NC - NC DQ0 - NC DQ2 DQ1 DQ

- DQ0 - NC DQ1 - NC - NC DQ0 - NC DQ2 DQ1 DQ

Mobile Low-Power DDR SDRAM MT46H16M16LF 4 Meg x 16 x 4 Banks MT46H8M32LF 2 Meg x 32 x 4 Banks 256Mb: x16, x32 Mobile LPDDR SDRAM Features Features V D

- - DQ0 NC DQ1 DQ0 DQ2 - NC DQ1 DQ3 NC - NC

SDR SDRAM. MT48LC64M4A2 16 Meg x 4 x 4 banks MT48LC32M8A2 8 Meg x 8 x 4 banks MT48LC16M16A2 4 Meg x 16 x 4 banks. Features. 256Mb: x4, x8, x16 SDRAM

Features Table 2: Configuration Addressing Architecture 32 Meg x 6 6 Meg x 32 Reduced Page Size 6 Meg x 32 Configuration 8 Meg x 6 x 4 banks 4 Meg x 3

Automotive LPDDR SDRAM

HYB25D256400/800AT 256-MBit Double Data Rata SDRAM

Notes: Clock Frequency (MHz) Target t RCD- t RP-CL t RCD (ns) t RP (ns) CL (ns) -6A E

128Mb DDR SDRAM. Features. Description. REV 1.1 Oct, 2006

IS42S32200C1. 512K Bits x 32 Bits x 4 Banks (64-MBIT) SYNCHRONOUS DYNAMIC RAM

128Mb Synchronous DRAM. Features High Performance: Description. REV 1.0 May, 2001 NT5SV32M4CT NT5SV16M8CT NT5SV8M16CT

SYNCHRONOUS DRAM. 256Mb: x4, x8, x16 SDRAM 3.3V

IS42S32200L IS45S32200L

Mobile Low-Power DDR SDRAM

HYB25D256[400/800/160]B[T/C](L) 256-Mbit Double Data Rate SDRAM, Die Rev. B Data Sheet Jan. 2003, V1.1. Features. Description

SDR SDRAM. MT48LC64M4A2 16 Meg x 4 x 4 banks MT48LC32M8A2 8 Meg x 8 x 4 banks MT48LC16M16A2 4 Meg x 16 x 4 banks. Features. 256Mb: x4, x8, x16 SDRAM

Automotive SDR SDRAM. MT48LC64M4A2 16 Meg x 4 x 4 banks MT48LC32M8A2 8 Meg x 8 x 4 banks MT48LC16M16A2 4 Meg x 16 x 4 banks.

DOUBLE DATA RATE (DDR) SDRAM

IS42S Meg Bits x 16 Bits x 4 Banks (64-MBIT) SYNCHRONOUS DYNAMIC RAM FEATURES OVERVIEW. PIN CONFIGURATIONS 54-Pin TSOP (Type II)

Ordering Information. Row Address. Row Decoder. Buffer & Refresh Counter. Column. Address. Buffer & Refresh Counter

A48P4616B. 16M X 16 Bit DDR DRAM. Document Title 16M X 16 Bit DDR DRAM. Revision History. AMIC Technology, Corp. Rev. No. History Issue Date Remark

HYB25D256400B[T/C](L) HYB25D256800B[T/C](L) HYB25D256160B[T/C](L)

V58C2256(804/404/164)SH HIGH PERFORMANCE 256 Mbit DDR SDRAM 4 BANKS X 8Mbit X 8 (804) 4 BANKS X 4Mbit X 16 (164) 4 BANKS X 16Mbit X 4 (404)

ESMT M13L32321A -7.5BG2G DDR SDRAM. 512K x 32 Bit x 2 Banks Double Data Rate SDRAM. Features. Ordering Information

TC59SM816/08/04BFT/BFTL-70,-75,-80

PMD706416A. Document Title. 64Mb (4M x 16) DDR SDRAM (A die) Datasheet

PMD709408C/PMD709416C. Document Title. Revision History. 512Mb (64M x 8 / 32M x 16) DDR SDRAM C die Datasheet

ESMT M12L A (2A) SDRAM. 4M x 16 Bit x 4 Banks Synchronous DRAM ORDERING INFORMATION FEATURES GENERAL DESCRIPTION

V58C2512(804/164)SH HIGH PERFORMANCE 512 Mbit DDR SDRAM 4 BANKS X 16Mbit X 8 (804) 4 BANKS X 8Mbit X 16 (164) Description

ESMT M13S A (2K) DDR SDRAM. 4M x 16 Bit x 4 Banks Double Data Rate SDRAM. Features. Ordering Information

IS42S16400J IS45S16400J

TABLE OF CONTENTS 1. GENERAL DESCRIPTION FEATURES PIN DESCRIPTION Signal Descriptions BLOCK DIAGRAM...

SDRAM DEVICE OPERATION

OKI Semiconductor MD56V82160

Part No. Organization tck Frequency Package. Part No. Organization tck Frequency Package

PMS306416C. Document Title. 64Mb (4Mb x 16) SDRAM (C die) Datasheet

PMS306416B. Document Title. Revision History. 64Mb (4Mb x 16) SDRAM Datasheet

Advantage Memory Corporation reserves the right to change products and specifications without notice

Feature. 512Mb DDR SDRAM. REV 1.1 Jul CAS Latency Frequency NT5DS64M8DS NT5DS32M16DS CONSUMER DRAM. 2KB page size for all configurations.

Advantage Memory Corporation reserves the right to change products and specifications without notice

IS42S Meg x MBIT SYNCHRONOUS DRAM SEPTEMBER 2009

Revision History Revision 1.0 (August, 2003) - First release. Revision 1.1 (February, 2004) -Corrected typo.

参考資料 PRELIMINARY DATA SHEET. 128M bits SDRAM. EDS1216AGTA (8M words 16 bits) DQ7 VDD LDQM /WE /CAS /RAS /CS BA0 BA1 A10 A0 A1 A2 A3 VDD

2M 4 BANKS 16 BITS SDRAM

Advantage Memory Corporation reserves the right to change products and specifications without notice

EM828164PAY-xxUx. Document Title. Revision History. 1 Rev M: 8M x 16 Mobile SDRAM. 128M: 8M x 16 Mobile SDRAM. Revision No.

128Mb Synchronous DRAM Specification

IS42S32160B IS45S32160B

8. OPERATION Read Operation Write Operation Precharge... 18

Shrink-TSOP. M464S3323CN0 SDRAM SODIMM 32Mx64 SDRAM SODIMM based on stsop2 16Mx8, 4Banks, 4K Refresh, 3.3V SDRAMs with SPD. Pin. Front. Pin.

128Mb Synchronous DRAM Specification

512K 2 BANKS 16 BITS SDRAM

V58C SJ HIGH PERFORMANCE 256 Mbit DDR SDRAM 4 BANKS X 4Mbit X 16. Description

HY[B/I]25D512400C[C/E/F/T](L) HY[B/I]25D512800C[C/E/F/T](L) HY[B/I]25D512160C[C/E/F/T](L)

Revision History. REV. 0.1 June Revision 0.0 (May, 1999) PC133 first published.

M464S1724CT1 SDRAM SODIMM 16Mx64 SDRAM SODIMM based on 8Mx16,4Banks,4K Refresh,3.3V Synchronous DRAMs with SPD. Pin. Pin. Back. Front DQ53 DQ54 DQ55

DQ18 DQ19 VDD DQ20 NC *VREF **CKE1 VSS DQ21 DQ22 DQ23 VSS DQ24 DQ25 DQ26 DQ27 VDD DQ28 DQ29 DQ30 DQ31 VSS **CLK2 NC NC SDA SCL VDD

1. GENERAL DESCRIPTION

PT483208FHG PT481616FHG

DATA SHEET. 512M bits SDRAM. EDS5104ABTA (128M words 4 bits) EDS5108ABTA (64M words 8 bits) EDS5116ABTA (32M words 16 bits) EOL Product VDD NC DQ0

256Mbit SDRAM. 8M x 8bit x 4 Banks Synchronous DRAM LVTTL. Revision 0.1 Sept. 2001

512 Mbit DDR SDRAM. This preliminary data sheet contains product specifications which are subject to change without notice.

IS42S32400B. 4Meg x MBIT SYNCHRONOUS DRAM

IS42S86400B IS42S16320B, IS45S16320B

W948D6KBHX. 256Mb Mobile LPDDR. Table of Contents- Publication Release Date: May 25, 2017 Revision: A

Mar.2016 SCB25D512800AE(F) SCB25D AE(F) 512Mbit DDR SDRAM EU RoHS Compliant Products. Data Sheet. Rev. C

1M 4 BANKS 16 BITS SDRAM

Feature. 512Mb LPDDR SDRAM

DS1230Y/AB 256k Nonvolatile SRAM

TS1SSG S (TS16MSS64V6G)

DS1250W 3.3V 4096k Nonvolatile SRAM

512K 4 BANKS 32BITS SDRAM

IS42S81600D IS42S16800D

DS1643/DS1643P Nonvolatile Timekeeping RAM

1M 4 BANKS 32BITS SDRAM

4 M 4 BANKS 16 BITS SDRAM

M52D128168A (2E) BALL CONFIGURATION (TOP VIEW) (BGA54, 8mmX8mmX1mm Body, 0.8mm Ball Pitch) VDDQ VDDQ VSSQ DQ6 DQ5 CAS BA0

512K 4 BANKS 32BITS SDRAM

1M 4 BANKS 32BIT SDRAM

Transcription:

Automotive Mobile LPSDR SDRAM MT48H32M6LF 8 Meg x 6 x 4 Banks MT48H6M32LF/LG 4 Meg x 32 x 4 Banks 52Mb: x6, x32 Automotive Mobile LPSDR SDRAM Features Features V DD /V D =.7.95V Fully synchronous; all signals registered on positive edge of system clock Internal, pipelined operation; column address can be changed every clock cycle Four internal banks for concurrent operation Programmable burst lengths:, 2, 4, 8, and continuous Auto precharge, includes concurrent auto precharge Auto refresh and self refresh modes LVTTL-compatible inputs and outputs On-chip temperature sensor to control self refresh rate Partial-array self refresh PASR Deep power-down DPD Selectable output drive strength DS 64ms refresh period; 32ms for automotive temperature Options V DD /V D :.8V/.8V ing Standard addressing option LF Reduced page size option LG Configuration 32 Meg x 6 8 Meg x 6 x 4 banks Marking H 32M6 6 Meg x 32 4 Meg x 32 x 4 banks 6M32 Plastic green packages 54-ball VFBGA 8mm x 8mm 2 B4 9-ball VFBGA 8mm x 3mm 3 B5 Timing cycle time 6ns at CL = 3-6 7.5ns at CL = 3-75 Power Standard I DD2 /I DD7 None Low-power I DD2 /I DD7 L Automotive certification Package-level burn-in A Operating temperature range Industrial 4 C to +85 C IT Automotive 4 C to +5 C AT Revision :C Notes:. Contact factory for availability. 2. Available only for x6 configuration. 3. Available only for x32 configuration. Table : Configuration ing Architecture 32 Meg x 6 6 Meg x 32 6 Meg x 32 Reduced Page Size Option Number of banks 4 4 4 Bank address balls BA, BA BA, BA BA, BA address balls A[2:] A[2:] A[3:] Column address balls A[9:] A[8:] A[7:] Note:. Contact factory for availability. Products and specifications discussed herein are subject to change by Micron without notice.

Features Table 2: Key Timing Parameters Clock Rate MHz Access Time Speed Grade CL = 2 CL = 3 CL = 2 CL = 3-6 4 66 8ns 5ns Note: -75 4 33 8ns 5.4ns. CL = CAS READ latency. Figure : 52Mb LPSDR Part Numbering MT 48 H 6M32 LF B5-6 A AT :C Micron Technology Product Family 48 = Mobile LPSDR SDRAM Operating Voltage H =.8V/.8V Configuration 32M6 = 32 Meg x 6 6M32 = 6 Meg x 32 ing LF = Standard addressing LG = Reduced page size Design Revision :C = Device generation Operating Temperature IT = Industrial 4 C to +85 C AT = Automotive 4 C to +5 C Automotive Certification A = Package-level burn-in Low Power Blank = Standard I DD2 /I DD7 L = Low-power I DD2 /I DD7 Cycle Time -6 = 6ns, t CK CL = 3-75 = 7.5ns, t CK CL = 3 Package Codes B4 = 8mm x 8mm, VFBGA, green B5 = 8mm x 3mm, VFBGA, green FBGA Part Marking Decoder Due to space limitations, FBGA-packaged components have an abbreviated part marking that is different from the part number. Micron s FBGA part marking decoder is available at www.micron.com/decoder. 2

Features Contents Important Notes and Warnings... 7 General Description... 7 Functional Block Diagram... 9 Ball Assignments and Descriptions... Package Dimensions... 3 Electrical Specifications... 5 Absolute Maximum Ratings... 5 Electrical Specifications I DD Parameters... 7 Electrical Specifications AC Operating Conditions... 2 Output Drive Characteristics... 24 Functional Description... 27 s... 28 COMMAND INHIBIT... 29 NO OPERATION... 29 LOAD MODE REGISTER LMR... 29 ACTIVE... 29 READ... 3 WRITE... 3 PRECHARGE... 32 BURST TERMINATE... 32 AUTO REFRESH... 32 SELF REFRESH... 33 DEEP POWER-DOWN... 33 Truth Tables... 34 Initialization... 39 Mode Register... 4 Burst Length... 42 Burst Type... 42 CAS Latency... 44 Operating Mode... 44 Write Burst Mode... 44 Extended Mode Register... 45 Temperature-Compensated Self Refresh... 45 Partial-Array Self Refresh... 46 Output Drive Strength... 46 Bank/ Activation... 47 READ Operation... 48 WRITE Operation... 57 Burst Read/Single Write... 64 PRECHARGE Operation... 65 Auto Precharge... 65 AUTO REFRESH Operation... 77 SELF REFRESH Operation... 79 Power-Down... 8 Deep Power-Down... 82 Clock Suspend... 83 Revision History... 86 Rev. C 6/8... 86 Rev. B /3... 86 Rev. A 2/3... 86 3

Features List of Figures Figure : 52Mb LPSDR Part Numbering... 2 Figure 2: Functional Block Diagram... 9 Figure 3: 54-Ball VFBGA Top View... Figure 4: 9-Ball VFBGA Top View... Figure 5: 54-Ball VFBGA 8mm x 8mm... 3 Figure 6: 9-Ball VFBGA 8mm x 3mm... 4 Figure 7: Typical Self Refresh Current vs. Temperature... 2 Figure 8: ACTIVE... 29 Figure 9: READ... 3 Figure : WRITE... 3 Figure : PRECHARGE... 32 Figure 2: Initialize and Load Mode Register... 4 Figure 3: Mode Register Definition... 4 Figure 4: CAS Latency... 44 Figure 5: Extended Mode Register Definition... 45 Figure 6: Example: Meeting t RCD MIN When 2 < t RCD MIN/ t CK < 3... 47 Figure 7: Consecutive READ Bursts... 49 Figure 8: Random READ Accesses... 5 Figure 9: READ-to-WRITE... 5 Figure 2: READ-to-WRITE With Extra Clock Cycle... 52 Figure 2: READ-to-PRECHARGE... 52 Figure 22: Terminating a READ Burst... 53 Figure 23: Alternating Bank Read Accesses... 54 Figure 24: READ Continuous Page Burst... 55 Figure 25: READ M Operation... 56 Figure 26: WRITE Burst... 57 Figure 27: WRITE-to-WRITE... 58 Figure 28: Random WRITE Cycles... 59 Figure 29: WRITE-to-READ... 59 Figure 3: WRITE-to-PRECHARGE... 6 Figure 3: Terminating a WRITE Burst... 6 Figure 32: Alternating Bank Write Accesses... 62 Figure 33: WRITE Continuous Page Burst... 63 Figure 34: WRITE M Operation... 64 Figure 35: READ With Auto Precharge Interrupted by a READ... 66 Figure 36: READ With Auto Precharge Interrupted by a WRITE... 67 Figure 37: READ With Auto Precharge... 68 Figure 38: READ Without Auto Precharge... 69 Figure 39: Single READ With Auto Precharge... 7 Figure 4: Single READ Without Auto Precharge... 7 Figure 4: WRITE With Auto Precharge Interrupted by a READ... 72 Figure 42: WRITE With Auto Precharge Interrupted by a WRITE... 72 Figure 43: WRITE With Auto Precharge... 73 Figure 44: WRITE Without Auto Precharge... 74 Figure 45: Single WRITE With Auto Precharge... 75 Figure 46: Single WRITE Without Auto Precharge... 76 Figure 47: Auto Refresh Mode... 78 Figure 48: Self Refresh Mode... 8 Figure 49: Power-Down Mode... 8 Figure 5: Clock Suspend During WRITE Burst... 83 4

Features Figure 5: Clock Suspend During READ Burst... 84 Figure 52: Clock Suspend Mode... 85 5

Features List of Tables Table : Configuration ing... Table 2: Key Timing Parameters... 2 Table 3: VFBGA Ball Descriptions... 2 Table 4: Absolute Maximum Ratings... 5 Table 5: DC Electrical Characteristics and Operating Conditions... 5 Table 6: Capacitance... 6 Table 7: I DD Specifications and Conditions, 4 C to 85 C x6... 7 Table 8: I DD Specifications and Conditions, 4 C to 85 C x32... 7 Table 9: I DD Specifications and Conditions,, 4 C to +5 C x6... 8 Table : I DD Specifications and Conditions, 4 C to +5 C x32... 8 Table : I DD7 Specifications and Conditions x6 and x32... 9 Table 2: Electrical Characteristics and Recommended AC Operating Conditions... 2 Table 3: AC Functional Characteristics... 22 Table 4: Target Output Drive Characteristics Full Strength... 24 Table 5: Target Output Drive Characteristics Three-Quarter Strength... 25 Table 6: Target Output Drive Characteristics One-Half Strength... 26 Table 7: Truth Table s and M Operation... 28 Table 8: Truth Table Current State Bank n, to Bank n... 34 Table 9: Truth Table Current State Bank n, to Bank m... 36 Table 2: Truth Table CKE... 38 Table 2: Burst Definition Table... 43 6

Important Notes and Warnings Micron Technology, Inc. "Micron" reserves the right to make changes to information published in this document, including without limitation specifications and product descriptions. This document supersedes and replaces all information supplied prior to the publication hereof. You may not rely on any information set forth in this document if you obtain the product described herein from any unauthorized distributor or other source not authorized by Micron. Automotive Applications. Products are not designed or intended for use in automotive applications unless specifically designated by Micron as automotive-grade by their respective data sheets. Distributor and customer/distributor shall assume the sole risk and liability for and shall indemnify and hold Micron harmless against all claims, costs, damages, and expenses and reasonable attorneys' fees arising out of, directly or indirectly, any claim of product liability, personal injury, death, or property damage resulting directly or indirectly from any use of nonautomotive-grade products in automotive applications. Customer/distributor shall ensure that the terms and conditions of sale between customer/distributor and any customer of distributor/customer state that Micron products are not designed or intended for use in automotive applications unless specifically designated by Micron as automotive-grade by their respective data sheets and 2 require such customer of distributor/customer to indemnify and hold Micron harmless against all claims, costs, damages, and expenses and reasonable attorneys' fees arising out of, directly or indirectly, any claim of product liability, personal injury, death, or property damage resulting from any use of non-automotive-grade products in automotive applications. Critical Applications. Products are not authorized for use in applications in which failure of the Micron component could result, directly or indirectly in death, personal injury, or severe property or environmental damage "Critical Applications". Customer must protect against death, personal injury, and severe property and environmental damage by incorporating safety design measures into customer's applications to ensure that failure of the Micron component will not result in such harms. Should customer or distributor purchase, use, or sell any Micron component for any critical application, customer and distributor shall indemnify and hold harmless Micron and its subsidiaries, subcontractors, and affiliates and the directors, officers, and employees of each against all claims, costs, damages, and expenses and reasonable attorneys' fees arising out of, directly or indirectly, any claim of product liability, personal injury, or death arising in any way out of such critical application, whether or not Micron or its subsidiaries, subcontractors, or affiliates were negligent in the design, manufacture, or warning of the Micron product. Customer Responsibility. Customers are responsible for the design, manufacture, and operation of their systems, applications, and products using Micron products. ALL SEMICONDUCTOR PRODUCTS HAVE INHERENT FAIL- URE RATES AND LIMITED USEFUL LIVES. IT IS THE CUSTOMER'S SOLE RESPONSIBILITY TO DETERMINE WHETHER THE MICRON PRODUCT IS SUITABLE AND FIT FOR THE CUSTOMER'S SYSTEM, APPLICATION, OR PRODUCT. Customers must ensure that adequate design, manufacturing, and operating safeguards are included in customer's applications and products to eliminate the risk that personal injury, death, or severe property or environmental damages will result from failure of any semiconductor component. Limited Warranty. In no event shall Micron be liable for any indirect, incidental, punitive, special or consequential damages including without limitation lost profits, lost savings, business interruption, costs related to the removal or replacement of any products or rework charges whether or not such damages are based on tort, warranty, breach of contract or other legal theory, unless explicitly stated in a written agreement executed by Micron's duly authorized representative. General Description 52Mb: x6, x32 Automotive Mobile LPSDR SDRAM Important Notes and Warnings The 52Mb Mobile LPSDR is a high-speed CMOS, dynamic random-access memory containing 536,87,92-bits. It is internally configured as a quad-bank DRAM with a synchronous interface all signals are registered on the positive edge of the clock signal,. Each of the x6 s 34,27,728-bit banks is organized as 892 rows by K columns by 6 bits. Each of the x32 s 34,27,728-bit banks is organized as 892 rows by 52 col- 7

General Description umns by 32 bits. In the reduced page size option, each of the x32 s 34,27,728-bit banks is organized as 6,384 rows by 256 columns by 32 bits. Mobile LPSDR offers substantial advances in DRAM operating performance, including the ability to synchronously burst data at a high data rate with automatic column-address generation, the ability to interleave between internal banks in order to hide precharge time, and the capability to randomly change column addresses on each clock cycle during a burst access. Note:. Throughout the data sheet, various figures and text refer to s as. should be interpreted as any and all collectively, unless specifically stated otherwise. Additionally, the x6 is divided into two bytes: the lower byte and the upper byte. For the lower byte [7:], M refers to LM. For the upper byte [5:8], M refers to UM. The x32 is divided into four bytes. For [7:], M refers to M. For [5:8], M refers to M. For [23:6], M refers to M2, and for [3:24], M refers to M3. 2. Complete functionality is described throughout the document; any page or diagram may have been simplified to convey a topic and may not be inclusive of all requirements. 3. Any specific requirement takes precedence over a general statement. 8

Functional Block Diagram Functional Block Diagram Figure 2: Functional Block Diagram CKE CS# WE# CAS# RAS# decode Control logic Bank Bank2Bank3 BA BA Bank 2 3 EXT mode register Mode register Refresh counter address MUX Bank row address latch and decoder Bank memory array Sense amplifiers n Data output register M BA, BA register 2 2 Bank control logic I/O gating M mask logic read data latch write drivers n Data input register n Column/ address counter/ latch Column decoder 9

Ball Assignments and Descriptions 52Mb: x6, x32 Automotive Mobile LPSDR SDRAM Ball Assignments and Descriptions Figure 3: 54-Ball VFBGA Top View 2 3 4 5 6 7 8 9 A V SS 5 V SSQ V D V DD B 4 3 V D V SSQ 2 C 2 V SSQ V D 4 3 D 9 V D V SSQ 6 5 E 8 DNU V SS V DD LM 7 F UM CKE CAS# RAS# WE# G A2 A A9 BA BA CS# H A8 A7 A6 A A A J V SS A5 A4 A3 A2 V DD Note:. The E2 pin must be connected to V SS, V SSQ, or left floating.

Ball Assignments and Descriptions Figure 4: 9-Ball VFBGA Top View 2 3 4 5 6 7 8 9 A 26 24 V SS V DD 23 2 A B 28 V D V SSQ V D V SSQ 9 B C V SSQ 27 25 22 2 V D C D V SSQ 29 3 7 8 V D D E V D 3 NC NC 6 V SSQ E F V SS M3 A3 A2 M2 V DD F G A4 A5 A6 A A A G H A7 A8 A2 A3 BA A H J CKE A9 BA CS# RAS# J K M DNU NC CAS# WE# M K L V D 8 V SS V DD 7 V SSQ L M V SSQ 9 6 5 V D M N V SSQ 2 4 3 V D N P V D V SSQ V D V SSQ 4 P R 3 5 V SS V DD 2 R Note:. The K2 pin must be connected to V SS, V SSQ, or left floating.

Ball Assignments and Descriptions Table 3: VFBGA Ball Descriptions Symbol Type Description Input Clock: is driven by the system clock. All SDRAM input signals are sampled on the positive edge of. also increments the internal burst counter and controls the output registers. CKE Input Clock enable: CKE activates HIGH and deactivates LOW the signal. Deactivating the clock provides precharge power-down and SELF REFRESH operation all banks idle, active power-down row active in any bank, deep power-down all banks idle, or CLOCK SUSPEND operation burst/access in progress. CKE is synchronous except after the device enters powerdown and self refresh modes, where CKE becomes asynchronous until after exiting the same mode. The input buffers, including, are disabled during power-down and self refresh modes, providing low standby power. CS# Input Chip select: CS# enables registered LOW and disables registered HIGH the command decoder. All commands are masked when CS# is registered HIGH. CS# provides for external bank selection on systems with multiple banks. CS# is considered part of the command code. CAS#, RAS#, WE# LM, UM 54-ball M[3:] 9-ball Input Input inputs: RAS#, CAS#, and WE# along with CS# define the command being entered. Input/Output mask: M is sampled HIGH and is an input mask signal for write accesses and an output enable signal for read accesses. Input data is masked during a WRITE cycle. The output buffers are High-Z two-clock latency during a READ cycle. For the x6, LM corresponds to [7:] and UM corresponds to [6:8]. For the x32, M corresponds to [7:], M corresponds to [5:8], M2 corresponds to [23:6], and M3 corresponds to [3:24]. M[3:] or LM and UM if x6 are considered same state when referenced as M. BA, BA Input Bank address inputs: BA and BA define to which bank the ACTIVE, READ, WRITE, or PRE- CHARGE command is being applied. BA and BA become Don t Care when registering an ALL BANK PRECHARGE A HIGH. A[3:] Input inputs: es are sampled during the ACTIVE command row and READ/WRITE command [column; column address A[9:] x6; with A defining auto precharge] to select one location out of the memory array in the respective bank. A is sampled during a PRE- CHARGE command to determine if all banks are to be precharged A HIGH or bank selected by BA, BA. The address inputs also provide the op-code during a LOAD MODE REGIS- TER command. The maximum address range is dependent upon configuration. Unused address pins become RFU. [3:] I/O Data input/output: Data bus. V D Supply power: Provide isolated power to for improved noise immunity. V SSQ Supply ground: Provide isolated ground to for improved noise immunity. V DD Supply Core power supply. V SS Supply Ground. DNU Do not use: Must be grounded or left floating. NC Internally not connected. These balls can be left unconnected but it is recommended that they be connected to V SS. Note:. Balls marked RFU may or may not be connected internally. These balls should not be used. Contact the factory for details. 2

Package Dimensions Package Dimensions Figure 5: 54-Ball VFBGA 8mm x 8mm Seating plane.2 A A.65 ±. 54X Ø.45 Solder ball material: SAC35 or SAC5. Dimensions apply to solder balls postreflow on Ø.4 SMD ball pads. 9 8 7 3 2 A Ball A ID Ball A ID B C 6.4 CTR D E F G 8 ±.5.8 TYP H J.8 TYP 6.4 CTR 8 ±.5 MAX.25 MIN Note:. All dimensions are in millimeters. 3

Package Dimensions Figure 6: 9-Ball VFBGA 8mm x 3mm Seating plane.2 A A.65 ±.5 9X Ø.45 Solder ball material: SAC5 98.5% Sn, % Ag,.5% Cu. Dimensions apply to solder balls postreflow on Ø.4 SMD ball pads..2 CTR.8 TYP 9 8 7 3 2 A B C D E F G H J K L M N P R Ball A ID 3 ±. Ball A ID.8 TYP 6.4 CTR. MAX.275 MIN 8 ±. Note:. All dimensions are in millimeters. 4

Electrical Specifications Electrical Specifications Absolute Maximum Ratings Stresses greater than those listed may cause permanent damage to the device. This is a stress rating only, and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability. Table 4: Absolute Maximum Ratings Voltage/Temperature Symbol Min Max Units Voltage on V DD /V D supply relative to V SS V DD /V D.5 2.4 V Voltage on inputs, NC or I/O balls relative to V SS V IN.5 2.4 Storage temperature plastic T STG 55 5 C Note:. V DD and V D must be within 3mV of each other at all times. V D must not exceed V DD. Table 5: DC Electrical Characteristics and Operating Conditions Notes and 2 apply to all parameters and conditions; V DD /V D =.7.95V Parameter/Condition Symbol Min Max Units Notes Supply voltage V DD.7.95 V I/O supply voltage V D.7.95 V Input high voltage: Logic ; All inputs V IH.8 V D V D +.3 V 3 Input low voltage: Logic ; All inputs V IL.3 +.3 V 3 Output high voltage V OH.9 V D V 4 Output low voltage V OL.2 V 4 Input leakage current: Any input V V IN V DD All other balls not under test = V I I.. μa Output leakage current: are disabled; V V OUT V D I OZ.5.5 μa Operating temperature Industrial T A 4 85 C Automotive T A 4 5 C Notes:. All voltages referenced to V SS. 2. A full initialization sequence is required before proper device operation is ensured. 3. V IH,max overshoot: V IH,max = V D + 2V for a pulse width 3ns, and the pulse width cannot be greater than one- third of the cycle rate. V IL undershoot: V IL,min = 2V for a pulse width 3ns. 4. I OUT = 4mA for full drive strength. Other drive strengths require appropriate scale. 5

Electrical Specifications Table 6: Capacitance Note applies to all parameters and conditions Parameter Symbol Min Max Units Input capacitance: C L 2. 5. pf Input capacitance: All other input-only balls C L2 2. 5. pf Input/output capacitance: C L 2.5 6. pf Note:. This parameter is sampled. V DD, V D =.8V; TA = 25 C; ball under test biased at.9v, f = MHz. 6

Electrical Specifications I DD Parameters 52Mb: x6, x32 Automotive Mobile LPSDR SDRAM Electrical Specifications I DD Parameters Table 7: I DD Specifications and Conditions, 4 C to 85 C x6 Note applies to all parameters and conditions; V DD /V D =.7.95V Parameter/Condition Operating current: Active mode; Burst = ; READ or WRITE; t RC = t RC MIN Symbol Max -6-75 Units Notes I DD 9 8 ma 2, 3, 4 Standby current: Power-down mode; All banks idle; CKE = LOW I DD2P 3 3 μa 5 Standby current: Non-power-down mode; All banks idle; CKE = HIGH I DD2N ma 3 Standby current: Active mode; CKE = LOW; CS# = HIGH; All banks active; No accesses in progress Standby current: Active mode; CKE = HIGH; CS# = HIGH; All banks active after t RCD met; No accesses in progress Operating current: Burst mode; READ or WRITE; All banks active, half of toggling every cycle I DD3P 5 5 ma 4, 6 I DD3N 2 8 ma 3, 4, 6 I DD4 9 ma 2, 3, 4 Auto refresh current: CKE = HIGH; CS# = HIGH t RFC = ns I DD5 95 95 ma 2, 3, 4, 6 t RFC = 7.825μs I DD6 3 3 ma 2, 3, 4, 7 Deep power-down I ZZ μa 5, 8 Table 8: I DD Specifications and Conditions, 4 C to 85 C x32 Note applies to all parameters and conditions; V DD /V D =.7.95V Parameter/Condition Operating current: Active mode; Burst = ; READ or WRITE; t RC = t RC MIN Symbol Max -6-75 Units Notes I DD 9 8 ma 2, 3, 4 Standby current: Power-down mode; All banks idle; CKE = LOW I DD2P 3 3 μa 5 Standby current: Non-power-down mode; All banks idle; CKE = HIGH Standby current: Active mode; CKE = LOW; CS# = HIGH; All banks active; No accesses in progress Standby current: Active mode; CKE = HIGH; CS# = HIGH; All banks active after t RCD met; No accesses in progress Operating current: Burst mode; READ or WRITE; All banks active, half toggling every cycle Auto refresh current: CKE = HIGH; CS# = HIGH I DD2N ma 3 I DD3P 5 5 ma 4, 6 I DD3N 2 8 ma 3, 4, 6 I DD4 5 95 ma 2, 3, 4 t RFC = ns I DD5 95 95 ma 2, 3, 4, 6 t RFC = 7.825μs I DD6 3 3 ma 2, 3, 4, 7 Deep power-down I ZZ μa 5, 8 7

Electrical Specifications I DD Parameters Table 9: I DD Specifications and Conditions,, 4 C to +5 C x6 Note applies to all parameters and conditions; V DD /V D =.7.95V Parameter/Condition Operating current: Active mode; Burst = ; READ or WRITE; t RC = t RC MIN Symbol Max -6-75 Units Notes I DD 9 8 ma 2, 3, 4 Standby current: Power-down mode; All banks idle; CKE = LOW I DD2P 6 6 μa 5 Standby current: Non-power-down mode; All banks idle; CKE = HIGH I DD2N 6 6 ma 3 Standby current: Active mode; CKE = LOW; CS# = HIGH; All banks active; No accesses in progress Standby current: Active mode; CKE = HIGH; CS# = HIGH; All banks active after t RCD met; No accesses in progress Operating current: Burst mode; READ or WRITE; All banks active, half of toggling every cycle I DD3P 6 6 ma 4, 6 I DD3N 2 9 ma 3, 4, 6 I DD4 9 ma 2, 3, 4 Auto refresh current: CKE = HIGH; CS# = HIGH t RFC = ns I DD5 95 95 ma 2, 3, 4, 6 t RFC = 7.825μs I DD6 8 8 ma 2, 3, 4, 7 Deep power-down I ZZ 5 5 μa 5, 8 Table : I DD Specifications and Conditions, 4 C to +5 C x32 Note applies to all parameters and conditions; V DD /V D =.7.95V Parameter/Condition Operating current: Active mode; Burst = ; READ or WRITE; t RC = t RC MIN Symbol Max -6-75 Units Notes I DD 9 8 ma 2, 3, 4 Standby current: Power-down mode; All banks idle; CKE = LOW I DD2P 6 6 μa 5 Standby current: Non-power-down mode; All banks idle; CKE = HIGH Standby current: Active mode; CKE = LOW; CS# = HIGH; All banks active; No accesses in progress Standby current: Active mode; CKE = HIGH; CS# = HIGH; All banks active after t RCD met; No accesses in progress Operating current: Burst mode; READ or WRITE; All banks active, half toggling every cycle Auto refresh current: CKE = HIGH; CS# = HIGH I DD2N 6 6 ma 3 I DD3P 6 6 ma 4, 6 I DD3N 2 9 ma 3, 4, 6 I DD4 5 95 ma 2, 3, 4 t RFC = ns I DD5 95 95 ma 2, 3, 4, 6 t RFC = 7.825μs I DD6 8 8 ma 2, 3, 4, 7 Deep power-down I ZZ 5 5 μa 5, 8 8

Electrical Specifications I DD Parameters Table : I DD7 Specifications and Conditions x6 and x32 Notes, 5, 9, and apply to all parameters and conditions; V DD /V D =.7.95V Parameter/Condition Symbol Low Power Standard Units Self refresh CKE = LOW; t CK = t CK MIN; and control inputs are stable; Data bus inputs are stable Notes: Full array, 5 C I DD7 N/A N/A μa Full array, 85 C TBD 7 μa Full array, 45 C TBD 39 μa Half array, 85 C TBD 52 μa Half array, 45 C TBD 3 μa /4 array, 85 C TBD 43 μa /4 array, 45 C TBD 275 μa /8 array, 85 C TBD 43 μa /8 array, 45 C TBD 275 μa /6 array, 85 C TBD 375 μa /6 array, 45 C TBD 25 μa. A full initialization sequence is required before proper device operation is ensured. 2. I DD is dependent on output loading and cycle rates. Specified values are obtained with minimum cycle time and the outputs open. 3. The I DD current will increase or decrease proportionally according to the amount of frequency alteration for the test condition. 4. transitions average one transition every two clocks. 5. Measurement is taken 5ms after entering into this operating mode to allow tester measuring unit settling time. 6. Other input signals are allowed to transition no more than once every two clocks and are otherwise at valid V IH or V IL levels. 7. CKE is HIGH during REFRESH command period t RFC MIN else CKE is LOW. 8. Typical values at 25 C not a maximum value. 9. Enables on-die refresh and address counters.. Values for I DD7 85 C full array and partial array are guaranteed for the entire temperature range. All other I DD7 values are estimated.. Self refresh is not supported for AT 85 C to 5 C operation. 9

Electrical Specifications I DD Parameters Figure 7: Typical Self Refresh Current vs. Temperature I DD6 µa 5 45 4 35 3 25 2 5 5 Full Half Quarter Eighth Sixteenth 4 25 45 6 75 85 9 2

Electrical Specifications AC Operating Conditions Electrical Specifications AC Operating Conditions Table 2: Electrical Characteristics and Recommended AC Operating Conditions Notes 5 apply to all parameters and conditions AC Characteristics -6-75 Parameter Symbol Min Max Min Max Unit Notes Access time from positive edge CL = 3 t AC 5 5.4 ns CL = 2 8 8 hold time t AH ns setup time t AS.5.5 ns high-level width t CH 2.5 2.5 ns low-level width t CL 2.5 2.5 ns Clock cycle time CL = 3 t CK 6 7.5 ns 6 CL = 2 9.6 9.6 CKE hold time t CKH ns CKE setup time t CKS.5.5 ns CS#, RAS#, CAS#, WE#, M hold time t CMH ns CS#, RAS#, CAS#, WE#, M setup time t CMS.5.5 ns Data-in hold time t DH ns Data-in setup time t DS.5.5 ns Data-out High-Z time CL = 3 t HZ 5 5.4 ns 7 CL = 2 8 8 ns Data-out Low-Z time t LZ ns Data-out hold time load t OH 2.5 2.5 ns Data-out hold time no load t OHn.8.8 ns ACTIVE-to-PRECHARGE command t RAS 42 2, 45 2, ns ACTIVE-to-ACTIVE command period t RC 6 67.5 ns 8 ACTIVE-to-READ or WRITE delay t RCD 8 9.2 ns Refresh period 892 rows t REF 64 64 ms 9, 8 AUTO REFRESH period t RFC 72 72 ns PRECHARGE command period t RP 8 9.2 ns ACTIVE bank a to ACTIVE bank b command t RRD 2 2 t CK Transition time t T.3.2.3.2 ns WRITE recovery time t WR 5 5 ns Exit SELF REFRESH-to-ACTIVE command t XSR 2 2 ns 2 2

Electrical Specifications AC Operating Conditions Table 3: AC Functional Characteristics Notes 5 apply to all parameters and conditions Parameter Symbol -6-75 Units Notes Last data-in to burst STOP command t BDL t CK 3 READ/WRITE command to READ/WRITE command t CCD t CK 3 Last data-in to new READ/WRITE command t CDL t CK 4 CKE to clock disable or power-down entry mode t CKED t CK 4 Data-in to ACTIVE command t DAL 5 5 t CK 5, 7 Data-in to PRECHARGE command t DPL 2 2 t CK 6, 7 M to input data delay t D t CK 3 M to data mask during WRITEs t M t CK 3 M to data High-Z during READs t Z 2 2 t CK 3 WRITE command to input data delay t DWD t CK 3 LOAD MODE REGISTER command to ACTIVE or REFRESH command t MRD 2 2 t CK CKE to clock enable or power-down exit mode t PED t CK 4 Last data-in to PRECHARGE command t RDL 2 2 t CK 6, 7 Data-out High-Z from PRECHARGE command CL = 3 t ROH 3 3 t CK 3 CL = 2 2 2 t CK Notes:. A full initialization sequence is required before proper device operation is ensured. 2. The minimum specifications are used only to indicate cycle time at which proper operation over the full temperature range 4 C T A +85 C industrial temperature and 4 C T A +5 C automotive temperature is ensured. 3. In addition to meeting the transition rate specification, the clock and CKE must transit between V IH and V IL or between V IL and V IH in a monotonic manner. 4. Outputs measured for.8v at.9v with equivalent load: Q 2pF Test loads with full driver strength. Performance will vary with actual system bus capacitive loading, termination, and programmed drive strength. 5. AC timing tests have V IL and V IH with timing referenced to V IH/2 = crossover point. If the input transition time is longer than t Tmax, then the timing is referenced at V IL,max and V IH,min and no longer at the V IH /2 crossover point. 6. The clock frequency must remain constant stable clock is defined as a signal cycling within timing constraints specified for the clock ball during access or precharge states READ, WRITE, including t WR, and PRECHARGE commands. CKE may be used to reduce the data rate. 7. t HZ defines the time at which the output achieves the open circuit condition, it is not a reference to V OH or V OL. The last valid data element will meet t OH before going High-Z. 8. DRAM devices should be evenly addressed when being accessed. Disproportionate accesses to a particular row address may result in reduction of the product lifetime. 9. This device requires 892 AUTO REFRESH cycles every 64ms t REF. Providing a distributed AUTO REFRESH command every 7.825μs meets the refresh requirement and ensures that each row is refreshed. Alternatively, 892 AUTO REFRESH commands can be issued in a burst at the minimum cycle rate t RFC, once every 64ms. 22

Electrical Specifications AC Operating Conditions. AC characteristics assume t T = ns. For command and address input slew rates <.5V/ns, timing must be derated. Input setup times require an additional 5ps for each mv/ns reduction in slew rate. Input hold times remain unchanged. If the slew rate exceeds 4.5V/ns, functionality is uncertain.. For auto precharge mode, the precharge timing budget t RP begins at t RP t CKns, after the first clock delay and after the last WRITE is executed. 2. must be toggled a minimum of two times during this period. 3. Required clocks are specified by JEDEC functionality and are not dependent on any timing parameter. 4. Timing is specified by t CKS. Clocks specified as a reference only at minimum cycle rate. 5. Timing is specified by t WR plus t RP. Clocks specified as a reference only at minimum cycle rate. 6. Timing is specified by t WR. 7. Based on t CK MIN, CL = 3. 8. For the automotive temperature parts, t REF = t REF/2. 23

Output Drive Characteristics 52Mb: x6, x32 Automotive Mobile LPSDR SDRAM Output Drive Characteristics Table 4: Target Output Drive Characteristics Full Strength Notes 2 apply to all parameters and conditions; characteristics are specified under best and worst process variations/ conditions Voltage V Pull-Down Current ma Pull-Up Current ma Min Max Min Max...... 2.8 8.53 2.8 8.53.2 5.6 26.8 5.6 26.8.3 8.4 32.8 8.4 32.8.4.2 37.5.2 37.5.5 4. 4. 4. 4..6 6.8 42.5 6.8 42.5.7 9.6 44.57 9.6 44.57.8 22.4 46.5 22.4 46.5.85 23.8 47.48 23.8 47.48.9 23.8 48.5 23.8 48.5.95 23.8 49.4 23.8 49.4. 23.8 5.5 23.8 5.5. 23.8 5.35 23.8 5.35.2 23.8 52.65 23.8 52.65.3 23.8 53.95 23.8 53.95.4 23.8 55.25 23.8 55.25.5 23.8 56.55 23.8 56.55.6 23.8 57.85 23.8 57.85.7 23.8 59.5 23.8 59.5.8 6.45 6.45.9 6.75 6.75 Notes:. Table values based on nominal impedance of 25Ω full drive strength at V D /2. 2. The full variation in drive current, from minimum to maximum due to process, voltage, and temperature will lie within the outer bounding lines of the I-V curves. 24

Output Drive Characteristics Table 5: Target Output Drive Characteristics Three-Quarter Strength Notes and 2 apply to all parameters and conditions; characteristics are specified under best and worst process variations/ conditions Voltage V Pull-Down Current ma Pull-Up Current ma Min Max Min Max.......96 2.97.96 2.97.2 3.92 8.76 3.92 8.76.3 5.88 22.96 5.88 22.96.4 7.84 25.94 7.84 25.94.5 9.8 28. 9.8 28..6.76 29.75.76 29.75.7 3.72 3.2 3.72 3.2.8 5.68 32.55 5.68 32.55.85 6.66 33.24 6.66 33.24.9 6.66 33.95 6.66 33.95.95 6.66 34.58 6.66 34.58. 6.66 35.4 6.66 35.4. 6.66 35.95 6.66 35.95.2 6.66 36.86 6.66 36.86.3 6.66 37.77 6.66 37.77.4 6.66 38.68 6.66 38.68.5 6.66 39.59 6.66 39.59.6 6.66 4.5 6.66 4.5.7 6.66 4.4 6.66 4.4.8 42.32 42.32.9 43.23 43.23 Notes:. Table values based on nominal impedance of 37Ω three-quarter drive strength at V D /2. 2. The full variation in drive current, from minimum to maximum due to process, voltage, and temperature will lie within the outer bounding lines of the I-V curves. 25

Output Drive Characteristics Table 6: Target Output Drive Characteristics One-Half Strength Notes 3 apply to all parameters and conditions; characteristics are specified under best and worst process variations/ conditions Voltage V Pull-Down Current ma Pull-Up Current ma Min Max Min Max.......27 8.42.27 8.42.2 2.55 2.3 2.55 2.3.3 3.82 4.95 3.82 4.95.4 5.9 6.84 5.9 6.84.5 6.36 8.2 6.36 8.2.6 7.64 9.3 7.64 9.3.7 8.9 2.3 8.9 2.3.8.6 2.2.6 2.2.85.8 2.6.8 2.6.9.8 22..8 22..95.8 22.45.8 22.45..8 22.73.8 22.73..8 23.2.8 23.2.2.8 23.67.8 23.67.3.8 24.4.8 24.4.4.8 24.6.8 24.6.5.8 25.8.8 25.8.6.8 25.54.8 25.54.7.8 26..8 26..8 26.48 26.48.9 26.95 26.95 Notes:. Table values based on nominal impedance of 55Ω one-half drive strength at V D /2. 2. The full variation in drive current, from minimum to maximum due to process, voltage, and temperature will lie within the outer bounding lines of the I-V curves. 3. The I-V curve for one-quarter drive strength is approximately 5% of one-half drive strength. 26

Functional Description 52Mb: x6, x32 Automotive Mobile LPSDR SDRAM Functional Description Mobile LPSDR devices are quad-bank DRAM that operate at.8v and include a synchronous interface. All signals are registered on the positive edge of the clock signal,. Read and write accesses to the device are burst oriented; accesses start at a selected location and continue for a programmed number of locations in a programmed sequence. Accesses begin with the registration of an ACTIVE command, followed by a READ or WRITE command. The address bits registered coincident with the ACTIVE command are used to select the bank and row to be accessed BA and BA select the bank. The address bits registered coincident with the READ or WRITE command are used to select the starting column location for the burst access. The device provides for programmable READ or WRITE burst lengths. An auto precharge function may be enabled to provide a self-timed row precharge that is initiated at the end of the burst sequence. The device uses an internal pipelined architecture that enables changing the column address on every clock cycle to achieve high-speed, fully random access. Precharging one bank while accessing one of the other three banks will hide the precharge cycles. The device is designed to operate in.8v memory systems. An auto refresh mode is provided, along with power-saving, power-down, and deep power-down modes. All inputs and outputs are LVTTL-compatible. The device offers substantial advances in DRAM operating performance, including the ability to synchronously burst data at a high data rate with automatic column-address generation, the ability to interleave between internal banks in order to hide precharge time, and the capability to randomly change column addresses on each clock cycle during a burst access. 27

s s The following table provides a quick reference of available commands, followed by a written description of each command. Additional Truth Tables Table 8 page 34, Table 9 page 36, and Table 2 page 38 provide current state/next state information. Table 7: Truth Table s and M Operation Note applies to all parameters and conditions Name Function CS# RAS# CAS# WE# M ADDR Notes COMMAND INHIBIT H X X X X X X NO OPERATION L H H H X X X ACTIVE select bank and activate row L L H H X Bank/row X 2 READ select bank and column, and start READ burst L H L H L/H Bank/col X 3 WRITE select bank and column, and start WRITE burst L H L L L/H Bank/col Valid 3 BURST TERMINATE or deep power-down enter deep power-down mode L H H L X X X 4, 5 PRECHARGE Deactivate row in bank or banks L L H L X Code X 6 AUTO REFRESH or SELF REFRESH enter self refresh mode L L L H X X X 7, 8 LOAD MODE REGISTER L L L L X Op-code X 9 Write enable/output enable X X X X L X Active Write inhibit/output High-Z X X X X H X High-Z Notes:. CKE is HIGH for all commands shown except SELF REFRESH and DEEP POWER-DOWN. 2. A[:n] provide row address where An is the most significant address bit, BA and BA determine which bank is made active. 3. A[:i] provide column address where i = the most significant column address for a given device configuration. A HIGH enables the auto precharge feature nonpersistent, while A LOW disables the auto precharge feature. BA and BA determine which bank is being read from or written to. 4. This command is BURST TERMINATE when CKE is HIGH and DEEP POWER-DOWN when CKE is LOW. 5. The purpose of the BURST TERMINATE command is to stop a data burst, thus the command could coincide with data on the bus. However, the column reads a Don t Care state to illustrate that the BURST TERMINATE command can occur when there is no data present. 6. A LOW: BA, BA determine the bank being precharged. A HIGH: all banks precharged and BA, BA are Don t Care. 7. This command is AUTO REFRESH if CKE is HIGH, SELF REFRESH if CKE is LOW. 8. Internal refresh counter controls row addressing; all inputs and I/Os are Don t Care except for CKE. 9. A[:] define the op-code written to the mode register.. Activates or deactivates the during WRITEs zero-clock delay and READs two-clock delay. 28

COMMAND INHIBIT NO OPERATION LOAD MODE REGISTER LMR 52Mb: x6, x32 Automotive Mobile LPSDR SDRAM s The COMMAND INHIBIT function prevents new commands from being executed by the device, regardless of whether the signal is enabled. The device is effectively deselected. Operations already in progress are not affected. The NO OPERATION command is used to perform a to the selected device CS# is LOW. This prevents unwanted commands from being registered during idle or wait states. Operations already in progress are not affected. The mode registers are loaded via inputs A[n:] where An is the most significant address term, BA, and BAsee Mode Register page 4. The LOAD MODE REGISTER command can only be issued when all banks are idle and a subsequent executable command cannot be issued until t MRD is met. ACTIVE The ACTIVE command is used to activate a row in a particular bank for a subsequent access. The value on the BA, BA inputs selects the bank, and the address provided selects the row. This row remains active for accesses until a PRECHARGE command is issued to that bank. A PRECHARGE command must be issued before opening a different row in the same bank. Figure 8: ACTIVE CKE HIGH CS# RAS# CAS# WE# address BA, BA Bank address Don t Care 29

s READ The READ command is used to initiate a burst read access to an active row. The values on the BA and BA inputs select the bank; the address provided selects the starting column location. The value on input A determines whether auto precharge is used. If auto precharge is selected, the row being accessed is precharged at the end of the READ burst; if auto precharge is not selected, the row remains open for subsequent accesses. Read data appears on the subject to the logic level on the M inputs two clocks earlier. If a given M signal was registered HIGH, the corresponding will be High- Z two clocks later; if the M signal was registered LOW, the will provide valid data. Figure 9: READ CKE HIGH CS# RAS# CAS# WE# Column address A EN AP DIS AP BA, BA Bank address Don t Care Note:. EN AP = enable auto precharge, DIS AP = disable auto precharge. 3

s WRITE The WRITE command is used to initiate a burst write access to an active row. The values on the BA and BA inputs select the bank; the address provided selects the starting column location. The value on input A determines whether auto precharge is used. If auto precharge is selected, the row being accessed is precharged at the end of the write burst; if auto precharge is not selected, the row remains open for subsequent accesses. Input data appearing on the is written to the memory array, subject to the M input logic level appearing coincident with the data. If a given M signal is registered LOW, the corresponding data is written to memory; if the M signal is registered HIGH, the corresponding data inputs are ignored and a WRITE is not executed to that byte/column location. Figure : WRITE CKE HIGH CS# RAS# CAS# WE# Column address A EN AP DIS AP BA, BA Bank address Valid address Don t Care Note:. EN AP = enable auto precharge, DIS AP = disable auto precharge. 3

s PRECHARGE The PRECHARGE command is used to deactivate the open row in a particular bank or the open row in all banks. The banks will be available for a subsequent row access a specified time t RP after the PRECHARGE command is issued. Input A determines whether one or all banks are to be precharged, and in the case where only one bank is precharged, inputs BA and BA select the bank. Otherwise BA and BA are treated as Don t Care. After a bank has been precharged, it is in the idle state and must be activated prior to any READ or WRITE commands are issued to that bank. Figure : PRECHARGE CKE HIGH CS# RAS# CAS# WE# A All banks Bank selected BA, BA Bank address Valid address Don t Care BURST TERMINATE AUTO REFRESH The BURST TERMINATE command is used to truncate either fixed-length or continuous page bursts. The most recently registered READ or WRITE command prior to the BURST TERMINATE command is truncated. AUTO REFRESH is used during normal operation and is analogous to CAS#-BEFORE- RAS# CBR REFRESH in FPM/EDO DRAM. ing is generated by the internal refresh controller. This makes the address bits Don t Care during an AUTO REFRESH command. 32

s SELF REFRESH The SELF REFRESH command is used to place the device in self refresh mode. The self refresh mode is used to retain data in the SDRAM while the rest of the system is powered down. When in self refresh mode, the device retains data without external clocking. The SELF REFRESH command is initiated like an AUTO REFRESH command, except that CKE is disabled LOW. After the SELF REFRESH command is registered, the inputs become Don t Care, with the exception of CKE, which must remain LOW. DEEP POWER-DOWN The DEEP POWER-DOWN DPD command is used to enter deep power-down mode, achieving maximum power reduction by eliminating the power to the memory array. To enter DPD, all banks must be idle. While CKE is LOW, hold CS# and WE# LOW, and hold RAS# and CAS# HIGH at the rising edge of the clock. To exit DPD, assert CKE HIGH. 33

Truth Tables Truth Tables Table 8: Truth Table Current State Bank n, to Bank n Notes 6 apply to all parameters and conditions Current State CS# RAS# CAS# WE# /Action Notes Any H X X X COMMAND INHIBIT /continue previous operation L H H H NO OPERATION /continue previous operation Idle L L H H ACTIVE select and activate row L L L H AUTO REFRESH 7 L L L L LOAD MODE REGISTER 7 L L H L PRECHARGE 8 active L H L H READ select column and start READ burst 9 Read auto precharge disabled Write auto precharge disabled L H L L WRITE select column and start WRITE burst 9 L L H L PRECHARGE deactivate row in bank or banks L H L H READ select column and start new READ burst 9 L H L L WRITE select column and start WRITE burst 9 L L H L PRECHARGE truncate READ burst, start PRECHARGE L H H L BURST TERMINATE 9, L H L H READ select column and start READ burst 9 L H L L WRITE select column and start new WRITE burst 9 L L H L PRECHARGE truncate WRITE burst, start PRECHARGE L H H L BURST TERMINATE 9, Notes:. This table applies when CKE n- was HIGH and CKE n is HIGH see Table 2 page 38 and after t XSR has been met if the previous state was self refresh. 2. This table is bank-specific, except where noted for example, the current state is for a specific bank and the commands shown can be issued to that bank when in that state. Exceptions are covered below. 3. Current state definitions: Idle: The bank has been precharged, and t RP has been met. active: A row in the bank has been activated, and t RCD has been met. No data bursts/accesses and no register accesses are in progress. Read: A READ burst has been initiated, with auto precharge disabled, and has not yet terminated or been terminated. Write: A WRITE burst has been initiated, with auto precharge disabled, and has not yet terminated or been terminated. 4. The following states must not be interrupted by a command issued to the same bank. COMMAND INHIBIT or commands, or supported commands to the other bank should be issued on any clock edge occurring during these states. Supported commands to any other bank are determined by the bank s current state and the conditions described in this and the following table. Precharging: Starts with registration of a PRECHARGE command and ends when t RP is met. After t RP is met, the bank will be in the idle state. activating: Starts with registration of an ACTIVE command and ends when t RCD is met. After t RCD is met, the bank will be in the row active state. 34

Truth Tables Read with auto precharge enabled: Starts with registration of a READ command with auto precharge enabled and ends when t RP has been met. After t RP is met, the bank will be in the idle state. Write with auto precharge enabled: Starts with registration of a WRITE command with auto precharge enabled and ends when t RP has been met. After t RP is met, the bank will be in the idle state. 5. The following states must not be interrupted by any executable command; COMMAND INHIBIT or commands must be applied on each positive clock edge during these states. Refreshing: Starts with registration of an AUTO REFRESH command and ends when t RFC is met. After t RFC is met, the device will be in the all banks idle state. Accessing mode register: Starts with registration of a LOAD MODE REGISTER command and ends when t MRD has been met. After t MRD is met, the device will be in the all banks idle state. Precharging all: Starts with registration of a PRECHARGE ALL command and ends when t RP is met. After t RP is met, all banks will be in the idle state. 6. All states and sequences not shown are illegal or reserved. 7. Not bank specific; requires that all banks are idle. 8. Does not affect the state of the bank and acts as a to that bank. 9. READs or WRITEs listed in the /Action column include READs or WRITEs with auto precharge enabled and READs or WRITEs with auto precharge disabled.. May or may not be bank specific; if all banks need to be precharged, each must be in a valid state for precharging.. This command is BURST TERMINATE when CKE is HIGH and DEEP POWER-DOWN when CKE is LOW. 35

Truth Tables Table 9: Truth Table Current State Bank n, to Bank m Notes 6 apply to all parameters and conditions Current State CS# RAS# CAS# WE# /Action Notes Any H X X X COMMAND INHIBIT /continue previous operation L H H H NO OPERATION /continue previous operation Idle X X X X Any command otherwise supported for bank m activating, active, or precharging Read auto precharge disabled Write auto precharge disabled Read with auto precharge Write with auto precharge L L H H ACTIVE select and activate row L H L H READ select column and start READ burst 7 L H L L WRITE select column and start WRITE burst 7 L L H L PRECHARGE L L H H ACTIVE select and activate row L H L H READ select column and start new READ burst 7, L H L L WRITE select column and start WRITE burst 7, L L H L PRECHARGE 9 L L H H ACTIVE select and activate row L H L H READ select column and start READ burst 7, 2 L H L L WRITE select column and start new WRITE burst 7, 3 L L H L PRECHARGE 9 L L H H ACTIVE select and activate row L H L H READ select column and start new READ burst 7, 8, 4 L H L L WRITE select column and start WRITE burst 7, 8, 5 L L H L PRECHARGE 9 L L H H ACTIVE select and activate row L H L H READ select column and start READ burst 7, 8, 6 L H L L WRITE select column and start new WRITE burst 7, 8, 7 L L H L PRECHARGE 9 Notes:. This table applies when CKE n- was HIGH and CKE n is HIGH Table 2 page 38, and after t XSR has been met if the previous state was self refresh. 2. This table describes alternate bank operation, except where noted; for example, the current state is for bank n and the commands shown can be issued to bank m, assuming that bank m is in such a state that the given command is supported. Exceptions are covered below. 3. Current state definitions: Idle: The bank has been precharged, and t RP has been met. active: A row in the bank has been activated, and t RCD has been met. No data bursts/accesses and no register accesses are in progress. Read: A READ burst has been initiated, with auto precharge disabled, and has not yet terminated or been terminated. Write: A WRITE burst has been initiated, with auto precharge disabled, and has not yet terminated or been terminated. 36

Truth Tables Read with auto precharge enabled: Starts with registration of a READ command with auto precharge enabled and ends when t RP has been met. After t RP is met, the bank will be in the idle state. Write with auto precharge enabled: Starts with registration of a WRITE command with auto precharge enabled and ends when t RP has been met. After t RP is met, the bank will be in the idle state. 4. AUTO REFRESH, SELF REFRESH, and LOAD MODE REGISTER commands can only be issued when all banks are idle. 5. A BURST TERMINATE command cannot be issued to another bank; it applies to the bank represented by the current state only. 6. All states and sequences not shown are illegal or reserved. 7. READs or WRITEs to bank m listed in the /Action column include READs or WRITEs with auto precharge enabled and READs or WRITEs with auto precharge disabled. 8. Concurrent auto precharge: Bank n will initiate the auto precharge command when its burst has been interrupted by bank m burst. 9. The burst in bank n continues as initiated.. For a READ without auto precharge interrupted by a READ with or without auto precharge, the READ to bank m will interrupt the READ on bank n, CAS latency CL later.. For a READ without auto precharge interrupted by a WRITE with or without auto precharge, the WRITE to bank m will interrupt the READ on bank n when registered. M should be used one clock prior to the WRITE command to prevent bus contention. 2. For a WRITE without auto precharge interrupted by a READ with or without auto precharge, the READ to bank m will interrupt the WRITE on bank n when registered, with the data-out appearing CL later. The last valid WRITE to bank n will be data-in registered one clock prior to the READ to bank m. 3. For a WRITE without auto precharge interrupted by a WRITE with or without auto precharge, the WRITE to bank m will interrupt the WRITE on bank n when registered. The last valid WRITE to bank n will be data-in registered one clock prior to the READ to bank m. 4. For a READ with auto precharge interrupted by a READ with or without auto precharge, the READ to bank m will interrupt the READ on bank n, CL later. The PRE- CHARGE to bank n will begin when the READ to bank m is registered. 5. For a READ with auto precharge interrupted by a WRITE with or without auto precharge, the WRITE to bank m will interrupt the READ on bank n when registered. M should be used two clocks prior to the WRITE command to prevent bus contention. The PRECHARGE to bank n will begin when the WRITE to bank m is registered. 6. For a WRITE with auto precharge interrupted by a READ with or without auto precharge, the READ to bank m will interrupt the WRITE on bank n when registered, with the data-out appearing CL later. The PRECHARGE to bank n will begin after t WR is met, where t WR begins when the READ to bank m is registered. The last valid WRITE bank n will be data-in registered one clock prior to the READ to bank m. 7. For a WRITE with auto precharge interrupted by a WRITE with or without auto precharge, the WRITE to bank m will interrupt the WRITE on bank n when registered. The PRECHARGE to bank n will begin after t WR is met, where t WR begins when the WRITE to bank m is registered. The last valid WRITE to bank n will be data registered one clock to the WRITE to bank m. 37