VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE (LTP) 400/ ,8 62,3/49,9 68,6/54,9 99,17

Similar documents
VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 41,8/33,4 46,0/36,8 64,02 400/ ,8 41,8/33,4 46,0/36,8 66,42

TECHNICAL SPECIFICATIONS

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 85,0/68,0 93,5/74,8 130,23 400/ ,8 85,0/68,0 93,5/74,8 135,12

Code: VOLVO TAD 734 GE MECC-ALTE ECO 38-1LN. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 250,0/200,0 275,0/220,0 397,4

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 172,9/138,3 190,6/152,5 265,44 400/ ,8 172,9/138,3 190,6/152,5 275,4

Code: KOHLER KDI1903M MECC-ALTE ECP 28-M/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 18,9/15,2 20,8/16,6 30,07

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 450,0/360,0 495,0/396,0 689,46 400/ ,8 450,0/360,0 495,0/396,0 715,32

Code: DEUTZ BF4M 1013 FC MECC-ALTE ECP 34-1L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP)

Code: VOLVO TAD 731 GE MECC-ALTE ECP 34-2L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 150,0/120,0 165,0/132,0 238,44

VOLTAGE HZ PHASE COS PRP KVA/KW LTP KVA/KW AMPERAGE A

ENGINE MAKE MODEL CONTINUOUS POWER PERKINS 2206A-E15TAG2 STAND-BY POWER

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 102,6/82,1 113,0/90,4 157,32 400/ ,8 102,6/82,1 113,0/90,4 163,22

Code: KOHLER KDW 1404 ZANARDI ATO 28-1VS/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 10,0/8,0 11,0/8,8 15,9

1 / Genset general description

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3

1 / Genset general description

1 / Genset general description

DGP-25 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

DGL 6 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GBW22Y. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

Standby Amper VOLTAGE

GBW22P. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

GSW80P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Technical specification

GMS-015Y. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GE.PK.022/020.SS+0_all

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

HFW-85 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Standard soundproofing Powered by FPT_IVECO

GSW150P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GE.VO.360/325.SS+0_all

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

GSW35Y. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Power kva 9,3 10 Power kw 9,3 10 Rated Speed r.p.m Standard Voltage V 240 Rated at power factor Cos Phi 1

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

,QGXVWULDO#*HQVHW. 3RZHU#5DWLQJ 4833#USP283#+] 4;33#USP293#+] 3ULPH 27.5kVA, 22.0kW 32.5kVA, 25.9kW 6WDQGE\ 30.0kVA, 24.1kW 35.5kVA, 28.

Standby Amper VOLTAGE

PRAMAC GBW 45. Main features. GBW Series. Item code: SB450TPAY kw. Standby power LTP. 34 kw. Rated prime power (PRP)

Standby Amper VOLTAGE

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

GCW22P (ALT. LSM) Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

GMR - 67P 67P 09/05/2016 GMR - 067P

WPS20/S EP Series. Features:

Subsidiaries: PORTUGAL POLAND GERMANY UK SINGAPORE UAE PANAMA DOMINICAN REPUBLIC ARGENTINA ANGOLA SOUTH AFRICA

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

WPS350/S EP Series. Features:

GSW500DO. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Alpha SERIES LWA 10(A)*, LWA 15(A), LWA 20(A), LWA 27(A) 50 Hz; 1500 r/min; power outputs: kva 60 Hz; 1800 r/min; power outputs:

This generator set is manufactured in facilities certified to ISO Voltage kva kw kva kw Amp 400/

JCB Diesel Generator Technical Specifications G45QX. Electrical. Prime

Large autonomy Safety Ease of handling Silent. 18,0/14,4 20,0/16,0 Yanmar 4TNE88PG. 18,5/14,8 19,6/15,7 Deutz F3M 1011 F

JCB Diesel Generator Technical Specifications G331QX. Electrical. Prime

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

WPS100/S EP Series. Features:

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

HDW-200 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by DOOSAN

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

SIVASA Doosan Series. SD250 Technical Data

Generating Rates SERVICE PRP STANDBY. HEAVY RANGE Container Powered by MTU

JCB Diesel Generator Technical Specifications G31RX. Electrical. Prime

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

WPS60/S EP Series. Features:

TPD2250H6.3 TECHNICAL DATA

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

HFW-350 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

WPS250/S EP Series. Features:

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

HFW-350 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

The enginewithintegrated water cooling

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

LWALR LIQUID COOLED LONG RUNNING GENSETS

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by YANMAR

50 Hz kva & PORTABLE RANGE. Rev. 0 07/05/2015

Power kva 11,5 12,4 Power kw 9,2 9,9 Rated Speed r.p.m Standard Voltage V 230/115 Rated at power factor Cos Phi 0,8

GSW145I. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GMS - 560V 06/05/2016 GMS - 560V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

YOUR POWER PARTNER. Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw 400/ ,

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

Standby Amper VOLTAGE

WPS150/S EP Series. Features:

Transcription:

Genset with manual control panel. Image for guidance purposes. ENGINE ALTERNATOR MAKE KOHLER MAKE MODEL KDI3404TM MODEL CONTINUOUS POWER: (PRP Prime Power norma ISO 8528-1) STAND-BY POWER: (LTP Limited Time Power norma ISO 8528-1) 60 kva 66 kva MECC-ALTE ECP32-2M/4B VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE (LTP) 400/230 50 3 0,8 62,3/49,9 68,6/54,9 99,17

ENGINE CHARACTERISTICS MAKE KOHLER MODEL KDI3404TM GENERAL DATA Power PRP (kwm) Power LTP (kwm) No. cylinders Cylinder capacity (L) Diameter per stroke (mm) Compression ratio Cooling system Injection Suction Series regulator Fly wheel coupling 55.40 61.00 4 3.359 96 x 116 - LIQUID DIRECT TURBO MECHANICAL 3-11,5" Lubrication system Oil capacity (L) Oil consumption (%) Min. alarm oil pressure (bar) 15.60 0.10 - Ventilation system Air cooling flow (m3/h) Combustion air flow (m3/h) Max. back pressure for fan (mbar) 6120 331.00 - Exhaust system Exhaust gas flow (m3/h) Exhaust back pressure (mbar) Temp. exhaust gases (ºC)) 291 90 650 Electrical system VDC (V) Battery (Ah) Engine start-up (kw) 12 90 -

ALTERNATOR CHARACTERISTICS MAKE MECC-ALTE MODEL ECP32-2M/4B GENERAL DATA Power PRP (kva) Power LTP (kva) Efficiency Alt. 3/4 % Efficiency Alt. 4/4 % No. Poles Voltage regulator No. wires Insulation Xd (%) X d (%) X Degree of protection 63.00 71.00 90.50 90.00 4 DSR 12 H 293.10 14.60 8.57 IP23 GENERATOR SET CONSUMPTION % POWER USED LITRES/HOUR 50% 8.20 75% 11.50 100% 14.60 DIMENSIONS, CAPACITIES, APPROXIMATE WEIGHT DIMENSIONS (MM) LENGTH WIDTH HEIGHT 2500 1100 1455 FUEL TANK (LITRES) WEIGHT (KG) 85 1300 NOISE LEVEL (db (A)) 64dB(A)@7m

INMESOL GENERATOR SET GENERAL DESCRIPTION The INMESOL generator set is an electrical energy generating machine which is used in places where there is no mains supply or when there is a MAINS failure. The mobile elements, distribution belt, fan, etc., and those parts which reach high temperatures during operation, exhaust manifold, etc, include their corresponding protections, in compliance with the requirements of the Machinery Directive 2006/42. REGULATIONS The machine holds the CE marking, and the corresponding Declaration of Conformity is issued with each of them, in which it specifies that the machine complies with R.D 842/2002 Low Voltage Regulations and with the European Directives: 2006/42 on Safety in Machinery. 2006/95/CE on Electrical Safety. 2004/108/CE on Electromagnetic Compatibility. 2005/88/CE on NOISE EMISSIONS by equipment for outdoor use (for SOUNDPROOF GENERATOR SETS).

SCOPE OF SUPPLY INDUSTRIAL RANGE Engine/alternator monobloc directly connected and installed via silent blocks on a frame made from high tensile electro welded steel profiles that are treated with degreasing liquids and aplicated with a phosphate coat and polyester (QUALICOAT) paint. Canopy of steel sheet sound proofed with fireproof rockwool, and treated with degreasing liquids and aplicated with a phosphate coat and polyester (QUALICOAT) paint. Fuel tank integrated in the base frame provided with fuel level jauge and fuel connections to the engine. Engine with mechanical engine driven pusher fan. Residencial silencer with -35 db(a) noise reduction with exhaust tube and protection cap. Electric control cubicle with control module including protection and reading of electrical meassures engine instrumentation fuel level and engine running hours, etc. Termal and magnetic circuit breaker and termal and magnetic circuit breaker and earth fault relay. Battery charge alternator. Starter battery complete with cables to the engine and pole protection. Installation prepared for earthing spike (spike not included). Security protection for heat and moving parts as well as live electrical components. External emergency stop push button. Manual engine oil extraction pump. Self excited and auto regulated alternator. Integrated lifting hook for single point lifting with crane, gensets up to 450 kva (Except in swing-out cover model) Preparate for extended fuel tank, fully bomded for leakage protection. Base frame is prepared for trailer kit installation. Standard electronic speed governor on engines from 220 kva (LTP) and up. Horizontal outlet for hot air OPTIONS Battery charger Coolant preheating AMF/ATS panel to turn a manual gen set to automatic version (consult the last page)

DSE 3110 MANUAL CONTROL PANEL MANUAL CONTROL, PROTECTION AND DISTRIBUTION panel, assembled on the generator set in metal cabinet with a DSE 3110 engine protection unit. Image for guidance purposes. It has the following: 1 2 3 STARTER SWITCH EMERGENCY STOP PUSHBUTTON MEASURING INSTRUMENTS: Analogue ammeters Analogue voltmeter Fuel level indicator. Digital Hz display and hour meter (DSE 3110)

DSE 3110 MANUAL CONTROL PANEL 4 SET CONTROL AND ENGINE PROTECTION: DSE 3110, allows: START AND STOP the set MANUALLY. Possibility of doing it AUTOMATICALLY via START ON SIGNAL Digital readings of the operating hours and the Frequency Controls the main characteristics of the engine, causing an alarm or stopping the machine: 1. Low and High Voltage (STOP) 2. Low and High Frequency and Speed (STOP) 3. Low Oil Pressure and High Coolant Temperature (STOP) 4. Failure of the Alternator Battery-Charger (ALARM) 5. Low fuel level (ALARM) 5 MAGNETO. PROTECTION (A) EARTH LEAK PROTECTION DISTRIBUTION 100A, 4P Electronic, adjustable CEE5P125A+CEE5P16A+S chuko

DSE 3110 MANUAL CONTROL PANEL 6 OPTIONAL: AUTOMATIC PANEL FOR MANUAL GENERATOR: ATS DSE 334 This panel provides the manual control generator with a reserve operation from the Mains, as the ATS sends the command to start and stop the generator, when it detects a supply failure and when the Mains is restored. Cubicle composed of the electronic control module which is detecting a mains failure and of 2 contactors mechanically and electrically interlocked or a motorized switch controlled by the above electronic controller who are realizing the change of supply from the GEN SET or the MAINS to the load.