testo 535 Instruction manual

Similar documents
testo 206 ph/ Temperature Measuring Instrument Bedienungsanleitung Instruction Manual

KANEAUTO 4-4 & KANE AUTO 5-4

Visit us at

Committing to the future. The digital manifold testo 550, ideal for all measurement work on refrigeration systems and heat pumps

Measuring Instruments for Pressure and Refrigeration

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

DT304. Digital Temperature Logger INSTRUCTION MANUAL

testo 108 Bedienungsanleitung Instruction manual Mode d emploi Manual de instrucciones Manuale di istruzioni Handleiding

testo 338 Portable Soot and Particulate Meter Versatile, digital display of particulates

SL101 Manual_SL101 User Manual 05/10/ :06 Page 1. Instruction Manual

Digital Formaldehyde Meter

OPERATING MANUAL EARTH RESISTANCE METER MRU-20

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

USER GUIDE. Model RH10 Hygro Thermometer. Humidity and Temperature Meter

Atlas 5. Instruction Manual. Handheld Indoor Air Quality Monitor. Measures CO2, Temperature and Humidity DISTRIBUTED BY

IAQ-CALC TM Indoor Air Quality Meter

IAQ-CALC TM Indoor Air Quality Meter

3550 series BATTERY HiTESTER

Indoor Air Quality Meter

Portable pressure calibrator, Wally Box III Model CPH7600

Visit us at

User's Guide. CO 2 Meter. Model CO250

EGQ 212: Duct transducer, CO 2 and temperature

RS MODEL 2030

Testing Instrumentation Gasboard 5020 for exhaust gases from petrol or LPG engines

INSTRUCTION MANUAL VISCOTESTER VT-05 / VT-06 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

USER MANUAL. Insulation Tester + DMM. Model MG320

Marin Control Digital

User Manual Rittal PMC UPS 6kVA

Flue Gas Analyzer IMR 1100F

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy

3. Packages 3.1 Characteristics Model number S4 (Package) Sensing element type Target gas VH Heater Voltage Electrical characteristics PH Powe

TESTO 350 Upgrades / Accessories / Spare Parts. Replacement Sensors

Overview. Application. Function. Design. Home

SPG-DIGI. Operating Instruction. Please read carefully before use!

Measuring Instruments for Pressure and Refrigeration

Measuring Instruments for Pressure and Refrigeration

500Z Owner's Manual & Troubleshooting

RAY COMPACT ENERGY METER MECHANICAL

Time Electronics. Calibration, Test and Measurement. Portable Process and Pressure Calibration Instruments

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

A2 Humidity Temperature Indicator SUPPLEMENTAL INSTRUCTIONS

Visit us at

Hand-Held Pressure Measuring Instrument "Manoport"

Model Battery Powered Milliohm Meter

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Slide Measuring Instrument GMG 200

ELPRO Lepenik & Co. d.o.o., Ob gozdu 7c, Rogoza, 2204 Miklavž na Dravskem polju, Slovenija tel:

1.Safe testing IMPORTANT:

CX-SERIES ADVANCED BATTERY CHARGER

D Dräger Alcotest 3000 Breath Alcohol Measuring Device

Mounting- and operating instructions Indoor Air Quality Guard LGW-13 CO 2 Detector

CO95. Carbon Monoxide Detector INSTRUCTION MANUAL ENGLISH Fax: (503)

Dräger EM200-E Diesel Exhaust Measurement

HYDRUS ULTRASONIC METER

PRODUCT CONFORMITY CERTIFICATE

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from DN 15mm qp 0,6m3/h up to DN 40mm qp 10m3/h

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

GE Measurement & Control

Short manual testo 610

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Quick Guide. brite Advanced Retail scale

one filter having K between 1.5 and 2.5 m -1

Three axis ( X, Y, Z ) electromagnetic field measurement 3 D EMF TESTER. Model : EMF-828

TABLE OF CONTENTS 1. FEATURES SPECIFICATIONS... 1

Instruction Manual PORTABLE ph METER D-71

True RMS Autoranging Multimeter

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Digital Insulation Resistance Testers. you can depend on

EiUK. Multi-Purpose Flue Gas Analyser. Service is what matters to most of us! Only 2 days turnaround

Autoranging Multimeter

i-stat 1 Analyzer 2 Before You Use the Analyzer

Temperature Calibrator

Installation and Connection: Installation and Operating Manual

Thermo-hygrometer-anemometer VT 210


Thermo-hygrometer-anemometer VT 210

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Instruction Manual. Vibration Calibrator VC20. Manfred Weber. Metra Mess- und Frequenztechnik in Radebeul e.k. Meissner Str D Radebeul

Operation Manual MODEL EC331. Microcomputer Based Conductivity /Resistivity & Temperature Pocket Meter EC331

Data sheet MULTICAL 6L2. Data loggers Info loggers Data backup in case of power failure MID-2004/22/EC EN 1434

Instruction Manual. Coating Thickness Gauge. Optionally with Memory

MULTICAL 6M2. Data sheet

MOM2 Micro-ohmmeter APPLICATIONS DESCRIPTION. MOM2 Micro-ohmmeter. Up to 220 A. Battery supplied. Lightweight 1 kg. Safe test DualGround

HOBO Data Logging Rain Gauge (RG3 and RG3-M) Manual

MA-LINE INSTRUMENTS

KANE425. Flue Gas Analyser. Kane International Ltd Kane House, Swallowfield Welwyn Garden City Hertfordshire, AL7 1JG

717 Series. Pressure Calibrators. Instruction Sheet. Introduction

HOBO Data Logging Rain Gauge (RG3 and RG3-M) Manual

HDS 5812 Amplified pressure sensor

COMPONENT-TESTER INSTRUCTION MANUAL

SoilStik ph Meter PRODUCT MANUAL. Item # 2105

Axle Load Scale XTR686

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Illustrations. Contents. Burns Connection Head. Models #22, #23 & #24 with Battery Powered LCD Indicator Instruction Manual

MOM2 Micro-ohmmeter. MOM2 Micro-ohmmeter. Up to 220 A. Battery supplied. Lightweight 1 kg. Safe test DualGround. Auto range: 1 µω to 1000 mω

Transcription:

testo 535 Instruction manual en

Mains connection (mains unit no. 0554.0088) recommended for long-term measuring. 2 line display Hold/Max/Min button START/STOP ON/OFF button Screw-off battery compartment Please read prior to operation Probe holder used with accessory set 0554.0550 PRINT button Measuring instruments conform with EN 50 081-1 + EN 50 082-1 - Never measure on live parts - Observe sensor measuring ranges! Overheating may destroy probes. - Observe storage and transport temperature as well as the max. operating temperature (e.g. protect measuring instrument from direct sunlight). - Inexpert handling or use of force cancel your warranty claims! - If there is a change in the ambient temperature (change of location, e.g. inner/outer temperature) the measuring instrument will need an adaptation phase of several minutes. - The CO2 probe contains optical components. Please treat the probe like your camera. Strong vibrationa may chenge the manufacturer s calibration. Check the readings in fresh air: 350 to 450 ppm. It is recommended that the instrument is sent to a Testo service point for adjustment purpose. - The CO2 probe is permanently attached to the measuring instrument. Probes can only be changed at Testo service points. - Ensure the probe does not come into frequent contact with water otherwise the long-term stability will be affected. - If the level of high frequency is high, there may be deviation from the required characteristic in the frequency range from 40 to 1000 MHz. Operation Switch on instrument. After the instrument is switched on a short display and function test follows and the sensor has a warm-up phase of approx. 30 s. The instrument is then ready to operate. The CO2 concentration in the sensor needs approx. 1 minute to adapt to ambient conditions. This adaptation time can be shortened by swinging the probe gently back and forth. If the probe is subjected to condensation, this can lead to uncreased mesured values. 2 The probe should be held as far as possible from your body so as to eliminate the influences caused by the CO2 in your breath. Auto-Off function If the Auto-Off function is activated the instrument switches itself off automatically after 10 minutes of inactivity (except in the case of HOLD) and timed mean calculation. Changing the battery If"Bat" appears in the display, the battery will last approx. 1 hour out of a total lifetime of 4 hours, if referring to an alkali-manganese battery. The instrument will switch off automatically if there is not enough power. Unscrew the battery compartment, remove the used battery and put in new battery, type 9V (IEC 6 F 22). (Observe polarisation). User settings remain intact if the instrument is not longer than 3 minutes without power. Instructions for disposal: Only empty batteries should be disposed. The batteries should be placed in plastic bags to prevent short-circuits. Technical data - testo 535 Sensor: 2 channel infrared absorption principle Measuring range: 0 to 9,999 ppm CO2 (0 to 0,999 vol.% CO2) Accuracy: 0 to 5000 ppm: (at 23 C *) ± (50 ppm +2 % of m.v.) 5000 to 9,999 ppm: ±(100 ppm +3 % of m.v.) Resolution: 1 ppm or 0.001 vol.% Ambient temperature: 0 to +50 C Storage temp.: -20 to +50 C Battery lifetime: >4h (9 V block, Al-Mn) Switchover: ppm / vol. % Display: LCD (11 mm digit height) Housing: ABS Dimensions: 190 x 57 x 42 mm Weight: Approx. 300 g Ambient humidity: 0 to 99 %RH not subjected to condensation Warranty testo 535 meas. instr...2 years Probe...1 year * Temp. coefficient: ± (1 ppm + 0,4 % of meas.) / C

Changing the settings - Configuration START/STOP button: keep pressed when switching on. The following settings can be changed: Date Time Auto ON BAT 01:01 1998 00:00 ppm 1013 hpa Auto-OFF function activated Battery in instrument Next position Next position Next position Auto OFF Auto-OFF function not activated ACCU Rechargeable battery in instrument 01:01 1998 00:00 Vol% 1013 hpa Measuring mode Set value Set value Set value Pressure compensation Please note that the CO2 reading depends on the absolute air pressure. This effect is compensated in the instrument. To do this, enter the correct air pressure (See Changing the settings - Configuration). The air pressure depends on the height of the location above (See the Barometric height formula table on the next page) and weather influences. Example: You are located at a height of 800 m above sea level where you have a mean annual air pressure of 920 hpa. According to the barometer (1003 hpa) and the height correction of the barometer (to 1013 hpa) the mean annual air pressure has to be reduced by 10 (910 hpa air pressure). Memory function for current, maximum and minimum values The following displays appear when this button is pressed again and again: 1st press: HOLD - 2nd press: MAX - 3rd press: MIN - 4th press: - 5th press: - 6th press: - Readings are frozen in display Displays saved max. values Displays saved min. values Multi-point mean calculation Timed mean calculation Return to measuring mode Important note: The min/max values are measured from the time the instrument is switched on. The values are reset if the instrument is switched off and then on again. Printout A printout of the reading with date and time can be activated by pressing the PRINT button. The max, min and mean values also appear on the printout of a multi-point or timed mean calculation. If a reading was frozen at a certain point in the display via the HOLD button, this reading appears in the printout with the time and date when the reading was frozen. 3

Mean calculation 4x Multi-point mean calculation 1310 0 Save required readings by pressing button. 1310 1450 0 3 7 Call up reading by pressing button. 0 3 7 This procedure can be repeated 999 times. The number of readings saved is counted in the display. Timed mean calculation 1310 1310 00:00 The clock starts to run in the display. Once the measurement has run for as long as required, press the Start/Stop button. The duration of the measurement can be extended by further Start/Stop intervals lasting up to a total of 99 hours and 59 minutes. The mean of the readings are taken over a certain period of time. The mean and duration are shown. 1450 1 : 2 5 1 : 2 5 Return to measuring mode Table: barometric height formula 4

Error messages Error message Cause Remedy in display Probe out of order Measuring range is exceeded. The readings lie outside the maximum measuring range Please contact the Testo service point Measuring range is exceeded. Does not damage probe. Ordering data testo 535 measuring instrument and accessories Part no. testo 535, CO2 measuring instrument for measuring the quality of ambient air, with securely attached probe, instruction manual, batteries and calibration protocol 0560.5350 TopSafe (indestructible protection case) with bench stand and belt clip, to protect instrument from impact, dirt... 0516.0183 9 V rechargeable battery, instead of battery 0515.0025 Recharger for 9 V rechargable battery, for external recharging of 0515.0025 battery 0554.0025 Plug-in mains unit for mains operation 0554.0088 Accessory set (for measuring instrument without TopSafe): belt clip, wall holder and carrying loop 0554.0550 Plastic case for storing measuring instrument, accessories, probes Testo log printer and accessories 0516.3250 Printer and accessories Testo log printer, prints measured data with date and time Part no. 0554.0545 Recharger with 4 NC rechargeable batteries for the Testo log printer, rechargeable batteries are recharged externally 0554.0110 Printer paper for Testo log printer (6 rolls) 0554.0569 5

testo AG Postfach 11 40, 79849 Lenzkirch Testo-Straße 1, 79853 Lenzkirch Telefon: (07653) 681-0 Fax: (07653) 681-100 E-Mail: info@testo.de Internet: http://www.testo.com 0973.5350/01/T/wh/08.08.2008