MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Similar documents
TripleLynx Inverter Range MAKING MODERN LIVING POSSIBLE. The benchmark solar inverter from Danfoss 3 phase Transformerless 8, 10, 12.

SolarMax 330TS-SV. The all-round solution for large-scale PV installations.

SolarMax 50TS/80TS/100TS/300TS. Ready for the future.

photovoltaikforum.com

Installation Instructions Bus Bar Kit for 6-pulse, 4-drive System VLT Series FC 102, FC 202, and FC 302. Description. Kit Part Number.

ABB central inverters PVS to 1000 kw

Manual. BlueSolar Grid Inverter 1500 / / / / / 230

GEatom306KHF-5U Three-phase Grid-Tied Battery Inverter. Version 1.1. Global Mainstream Dynamic Energy Technology Ltd. 1

Control Card VLT FC Series

SolarMax 20C/25C/30C/35C. Proven reliability.

ABB central inverters PVS to 1000 kw

ABB central inverters PVS to 2091 kva

PV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control

SolarMax S series (Australia) Maximising solar plant yields can be so easy.

Installation Instructions 300 A Current Sensor Kit for D1h/D3h/D5h/D6h Enclosure Sizes VLT Series FC 102, FC 103, FC 202, and FC 302

SolarMax MT series. The power pack for maximum yields.

ABB central inverters PVS to 2000 kva

User Manual Solar Charge Controller 3KW

Installation Instructions In-bottom/Out-back Cooling Kit for E4h Drives VLT FC Series FC 102, FC 103, FC 202, and FC 302

User Manual. Solar Charge Controller 3KW

Changing pistons APP and APP 16-22

SolarMax MT series The all-rounder for trade and industry

T Series (N6052T) Solar Battery Hybrid System. Installation Manual Version 1.1

ABB central inverters ULTRA-750/1100/ kW to 1560kW

Installation Guide. VLT Real-time Clock MCB 117 VLT HVAC Drive FC 102, VLT Refrigeration Drive FC 103, VLT AQUA Drive FC 202, VLT AutomationDrive

SolarMax S series (United Kingdom) Maximising solar plant yields can be so easy.

Installation Instructions 500 A Current Sensor Kit for F1 F4/F8 F13 Enclosure Sizes VLT Series FC 102, FC 202, and FC 302

HANGKAI GROUP HOYMILES MICRO-INVERTER MI-250

3 Phase Power Systems - Designed for Canada

500 / 630 / 720 / 760 / 800 / 850 / 900

Appendix: Safety and application notes for... 15

Pre-announcement. Transformerless Solar Inverters

Energy Storage System for Home

Fuse state indicator MEg72. User manual

KCR1. Kiln Controller Handbook. Kilncare Ltd. The Kiln Works 907 Leek New Road Baddeley Green Stoke-on-Trent Staffordshire, ST2 7HQ United Kingdom

Installation Instructions 500 A Current Sensor Kit for D2h/D4h/D7h/D8h Enclosure Sizes VLT Series FC 102, FC 103, FC 202, and FC 302

Green Inverters from. Solar inverters. for Asia. Solar inverters. for Europe. Solar inverters. for America. Solar inverters.

Energy Storage System for Home. High Efficiency - Peak efficiency 97.3% Bi-directional DC-DC converter

Photovoltaics. MPI Hybrid Series

Installation Guide. DEVIreg 527. Electronic Time Regulator.

97.3% The Danfoss DLX PV inverter Series Performance and flexibility in a user friendly design. For residential installations from 2.0 kw to 4.

PV Inverter SUNNY BOY 3300/3800

Technical specifications

SolarMax P series The power package for residential solar plants

OPERATIONS MANUAL CR Thermoreactor

Sunny Tripower CORE1.

The sun as power station

Technical Documentation

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

SP PRO ABB Managed AC Coupling

GRUNDFOS DATA BOOKLET. Grundfos RSI. Renewable solar inverter for pump control kw

Retrofit to Single phase / Three phase PV system Micro-grid, UPS, Peak shift, Pure off-grid retrofitting etc multi-working

OHY3P kW Hybrid Inverter (3-Phase) USER MANUAL V2.0

TECHNICAL SPECIFICATION FOR ENERGY STORAGE SYSTEM REV 6.0

String Inverter (SUN KTL-A)

User Manual. SP10000 Premium

ABB string inverters PVI-3.8/4.6-I-OUTD 3.8 to 4.6 kw

ABB string inverters UNO-DM-1.2/2.0/3.3/4.0/4.6/5.0-TL-PLUS-Q 1.2 to 5.0 kw

Appendix: Safety and application notes for 19

Power Conversion System The Best Technology for your photovoltaic and storage system

CPS Energy Balancer. Version: 1.0

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Instruction Manual. Harmonic Filter AHF 005/010. Drives Solutions

Overview of types. Technical data. Safety notes

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Extended Battery Cabinet for Nfinity

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

ADDENDUM to INSTALLATION INSTRUCTIONS for Grant Solar Pump Station

Steca Elektronik SOLARIX PLI

Sunny Tripower. Can do everything that we can

User Manual. Hybrid 4KW PV Inverter. Version: 1.2

INSTRUCTION & INSTALLATION

Advanced efficiency, precision cooling Design an HVAC system like no other

Central Inverter SUNNY CENTRAL 500HE-20/630HE-20/720HE-20/ 760HE-20/800HE-20

MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13.

Central Inverter SUNNY CENTRAL 500CP-JP / 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900 CP XT

Application. Battery. Public Grid GS HYBRID INVERTER

Aurora Wind Interface Box

1. Introduction OHY1P kW Hybrid Inverter USER MANUAL V2.0

DBC-1 DEIF Battery Charger

Advanced efficiency, precision cooling Design an HVAC system like no other

& Operation Manual. Growatt 10000HY. Installation GR-UM-A03-A-00

MASTERYS IP+ 10 to 80 kva

HOYMILES MICRO-IVERTER MI-250

Green Power 2.0 MASTERYS GP

Operating Instructions (Translation)

Wind Energy System.

i-energy i-micro inverter GT260

Benefits, typical uses

SonoMeter 30 Energy Meters

Renewable Solar Inverter, RSI

ORVALDI Solar Infini 5kW

Advanced efficiency, precision cooling Design an HVAC system like no other

Commercial 1000VDC String Inverter XGI Installation and Operation Guide Models: XGI XGI

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

Get ready for rising energy challenges. This is where xstorage Home can help

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

MERU Solar Off-Grid Inverters

Electrical data Nominal voltage AC 24 V Nominal voltage frequency

Transcription:

MAKING MODERN LIVING POSSIBLE UniLynx Indoor Installation Manual ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Contents Contents 1. Introduction 2 Introduction 2 Installation Sequence 2 Important Safety Information 3 DC-switch (PV-load switch) 4 Inverter Overview 4 2. Installation and Setup 5 Installation and Setup 5 Mounting and Removal 6 How to Open the Inverter 7 Connection of Strings 8 AC Connection 9 3. Specifications 12 Specifications 12 L00410293-06_02 1

1. Introduction 1 1. Introduction 1.1. Introduction This manual describes the installation and set-up of Danfoss photovoltaic inverters. All persons installing inverters must be trained in and have experience with the general safety rules to be observed when working on electrical equipment. Installation personnel should also be familiar with local requirements, rules and regulations as well as safety requirements. The ULX inverter is a transformer-based inverter with galvanic isolation. Illustration 1.1: ULX Indoor Range 1.1.1. Installation Sequence 1. Read the manual, pay special attention to the section on safety. 2. Install the inverter according to Chapter 2. 3. Install AC, see section on AC Connection. 4. Install PV. Remember the terminal block if parallel connection is required, see section Connection of Strings (see also How to Open the Inverter). 5. Turn on AC at the mains switch. 6. Set language and country as prompted by the display. 7. Turn on PV by turning the DC-switch on. 8. The inverter is now ready for operation. 2 L00410293-06_02

1. Introduction 1.1.2. Important Safety Information 1 Safety information important for human safety. Violation of warnings may result in injury to persons or death. Information important for the protection of property. Violation of this type of information may cause damage and loss of property. Note: Useful additional information or Tips and Tricks on specific subjects. Read this before installing, operating or maintaining the inverter. Before installation: Check for damage to inverter and packaging. If you are in doubt, please contact your supplier before installing the inverter. Check the voltages of the solar modules and make sure they are within the limits of the Danfoss inverter specifications before connecting them to the inverter (see section Connection of Strings ). Installation: Only trained and authorised personnel familiar with local electrical codes may install the inverter. For optimum safety, please follow the steps described in this manual. Keep in mind that the inverter has two voltage carrying sides, the PV input and the AC grid. Disconnecting the inverter: Always disconnect the AC line first! Afterwards disconnect the PV lines. Note that the inverter can still be charged with very high voltages at hazardous levels even when it is disconnected from grid/mains and solar modules. Wait at least 15 min. before proceeding, after having disconnected from grid and PV panels. Operating the inverter: Before connecting the AC grid to the inverter, make sure that the installation cover is mounted again. The inverter must not be open during operation. Maintenance and modification: Only authorised personnel are allowed to repair or modify the inverter. To ensure optimum safety for user and environment, only the original spare parts available from your supplier should be used. Functional safety parameters: Unauthorised changes of functional safety parameters may cause injury or accidents to people or inverter. Additionally it will lead to the cancelling of all inverter operating approval certificates. The Danfoss inverters in the ULX range are all designed according to the German VDE0126-1-1 (February 2006) standard. If non-original spare parts are used, the compliance with CE guidelines in respect of electrical safety, EMC and machine safety is not guaranteed. L00410293-06_02 3

1. Introduction 1 1.1.3. DC-switch (PV-load switch) DC-switch (PV-load switch), for safe disconnection of DC current. Illustration 1.2: DC-switch (PV-load switch) 1.1.4. Inverter Overview Connection Area Illustration 1.3: Inverter Overview - Indoor 1. AC connection 2. RS485 3. PV connection 4 L00410293-06_02

2. Installation and Setup 2. Installation and Setup 2.1. Installation and Setup 2 This manual provides information about all aspects concerning the inverter and legislative requirements known at the time of writing. However, always check the local requirements and ensure that the inverter is installed and operated in accordance with these requirements. Before installation, always check the packaging and inverter for damage. A suitable environment for Danfoss inverters is specified in the environmental class IE34, in accordance with IEC 721-3-3, with the following exceptions: Indoor mounting Temperature range: 25 to 60 C Humidity: 0-95%, no condensation Enclosure IP 21: No spraying water Vibration: 1G Choosing the Installation Place The inverter must be mounted on a wall to ensure an adequate flow of air to the cooling element on the back side of the inverter. If it is not possible to mount the inverter on a wall, it must be secured on a plate that is at least as large as the inverter. Use a wall that is sufficiently flat and firm to carry the inverter weight. Do not install the inverter on flammable surfaces (wood or similar) or close to flammable materials. Illustration 2.1: Installation Dimensions L00410293-06_02 5

2. Installation and Setup 2 Illustration 2.2: Installation Patterns Inverter type Weight, kg Dimensions, L W H, mm ULX 1800i 14 kg 369 386 188 ULX 3000i / 3600i 20 kg 498 386 188 ULX 5400i 23 kg 631 386 188 Table 2.1: Inverter Weight and Dimensions 2.1.1. Mounting and Removal Wall Bracket The wall bracket is fixed to the wall with four screws, with a maximum diameter of 8 mm. Select the appropriate screw type and dimensions for the wall material and inverter size. Make sure that the wall construction, screw type, and wall plugs are capable of securely carrying the weight of the inverter and wall bracket. Illustration 2.3: Wall Bracket 6 L00410293-06_02

2. Installation and Setup Mounting Slide the inverter upwards until the inverter snaps into the wall bracket top slots, and lower the inverter until it rests in the wall bracket slots (1). Push the bottom end of the inverter against the wall until the lock spring snaps in place (2). Check that the inverter is now securely fixed to the wall bracket. 2 Illustration 2.4: Mounting Removal Insert a screwdriver or similar into the wall bracket side slot (1). Move the screwdriver upwards while pulling the inverter away from the wall until the lock spring disengages. Pull the inverter bottom end away from the wall (2). Slide the inverter upwards until it disengages from the wall bracket and remove it from the wall (3). Illustration 2.5: Removal 2.1.2. How to Open the Inverter Follow the steps below to open the inverter: 1. Unscrew the screw in the DC-switch and remove the knob. 2. Unscrew the 2 screws holding the cover in place. 3. Pull the cover upwards. 4. Tilt and pull up and away from the inverter. 5. Unplug the earth cable before removing the cable cover. Illustration 2.6: How to Open the Inverter Follow the procedure below to close the inverter: 1. Go through the above steps in the reverse order. L00410293-06_02 7

2. Installation and Setup 2 2.1.3. Connection of Strings The screw terminals must only be used for the Master/Slave set. Do NOT use them for connection of PV modules. The screw terminals will not be disconnected from the inverter by the DC-switch. Illustration 2.7: PV Connection Note: Make sure PV wires from solar panels are connected to the inverter with the correct polarity. The inverter does not suffer any damage, but it will not generate power until the polarity is corrected. The max. input voltage, as defined in the specifications, shall be higher than the Standard Test Condition (STC) open circuit voltage for the PV modules / array multiplied with a factor of 1.13. Please observe that thin film modules may produce a higher voltage and current output before initial degradation, and ensure UOC, STC x 1.13 UMAX, inv is also valid in this case. Individual Configuration Individual configuration is used when PV panels have different angles, orientation, or are of varying types. This is the default setting Parallel Configuration Parallel configuration is used when all PV panels are identical both in type and in system installation. Master/Slave set for parallel configuration. Illustration 2.8: Parallel Configuration The inverter runs an automatic PV configuration test just after connection to grid. During this test the configuration of the PV modules is determined. The status of the test and the result can be 8 L00410293-06_02

2. Installation and Setup found in menu B in the display. The inverter will always run according to the configuration of the PV modules. 2.1.4. AC Connection The inverter must be connected to the earth wire in order to prevent injury to the user. Make sure the AC grid is switched off at the mains breaker before connecting the mains cable. 2 Ensure that the power supply is disengaged using the power disconnect switch before connecting the power cable. When connecting the power cable to the socket, ensure that all cables are firmly attached to prevent bad connections. Connection to the AC grid is established by means of an AC connector. The connector is located on the cabinet exterior. Installation of the AC Connector: First slide pressure screw and seal ring over the cable. Connect individual cores to bush insert row by row: - Connect PE earth conductor to screw terminal with earthing symbol. - Connect zero conductor N to screw terminal. - Connect phase L to screw terminal L Check that cores are connected properly. Slide the cap over the bush insert until locking catch is in correct position. Now slide seal ring into the cap, and tighten the pressure screw. Illustration 2.9: AC Cable L00410293-06_02 9

2. Installation and Setup AC Cable Requirements 2 A total loss of 1% is recommended when dimensioning the AC cables, between the inverters and energy-meter. The cable cross-sections specified below are recommended for cable lengths up to 10 m. Specification ULX 1800i ULX 3000i / 3600i ULX 5400i When selecting cable for the AC installation, ensure to comply with local and national regulations. Recommended minimum cable requirements (PVC coated wire) > 1.5 mm 2 double insulated, approved house wiring cable > 2.5 mm 2 double insulated, approved house wiring cable > 4.0 mm 2 double insulated, approved house wiring cable Indoor use 500 [V] 500 [V] 500 [V] Temperature range 0 - +60 C 0 - +60 C 0 - +60 C Extended temperature 0 - +90 C 0 - +90 C 0 - +90 C range Indoors max. 10 mm 10 mm 10 mm Table 2.2: AC Cable Requirements Fuses The main purpose of the fuse is to protect the installation against short circuits. It is recommended to use a slow fuse, class C. When selecting the fuse for the AC installation, ensure to comply with local and national regulations. Specification ULX 1800i ULX 3000i / 3600i ULX 5400i Fuse Current 16A 16A 25A Voltage 240V 240V 240V Table 2.3: Recommended fuses An automatic test of the inverter can be initialised by using the Inverter Autotest Software. Please read the Autotest manual before initialising the software. Software and manual are available free of charge, please contact your supplier for further information. The software is used in conjunction with an RS485 to USB converter in order to communicate between inverter and PC. Such a converter can be purchased at any retailer of computer equipment. Note: This is an international inverter. The inverter is approved and certified to run in 16 countries. The inverter has not had country settings specified. It will not run before this has been done. Check that all connections have the correct polarity and that cables are securely fastened. Turn on the AC grid. The display will now prompt for Language. Press to scroll down through the languages. Select language by pressing OK. The display will now show Country in the language chosen previously. Illustration 2.10: Language 10 L00410293-06_02

2. Installation and Setup Illustration 2.11: Country Press to scroll down through the list of countries. Select the country in which the inverter is installed by pressing OK. Confirm selection by pressing OK The settings for the selected country has now been activated, and the inverter is ready to energise the AC grid. 2 The inverter will start automatically if sufficient solar radiation is available. The start-up will take a few minutes. During this period, the inverter will carry out a self-test. The inverter only complies with local and national standards provided the correct country has been selected. If a different country than the one the inverter is installed in is chosen it can have serious consequences. L00410293-06_02 11

3. Specifications 3. Specifications 3.1. Specifications 3 Parameter Condition Specification UGRID AC grid voltage 180-270 V AC FGRID AC grid frequency Settings 50/60 Hz 46-55/55-65 HZ TMAX Max. operating temperature 60 C ambient TMIN Min. operating temperature -25 C ambient TNOM Nom. operating temperature Nominal power 25 C ambient Relative humidity 0-95% non condensing Enclosure rating IP 21 Acoustic noise SWL 45 dba PF Power factor P > 20 % 0.97 ITHD Total harmonic distortion PNOM < 5 % Safety class Complete inverter Class I Galvanic isolation class Communication interface Class II Input surge protection Common mode 4 kv Islanding protection U/F window Islanding detection ENS Options ENS acc. to VDE 0126-1-1 Limitation of 10 minutes mean 1% power loss in AC cable Acc. to EN50160 AC grid voltage Reverse polarity protection Integrated Overvoltage category According to IEC 60 664-1 III Pollution degree According to IEC 60 664-1 2 DC-switch Integrated. acc. to VDE 0100-712 Galvanic isolation Inverter Transformer with galvanic isolation Table 3.1: Specifications Parameter ULX 1800i ULX 3000i ULX 3600i ULX 5400i Input Nominal input power DC 1800 W 3000 W 3600 W 5400 W Max. power DC 1950 W 3200 W 3900 W 5850 W Starting capacity 20 W Power consumption (Off mode) <0.2 W Power consumption (Standby mode) 8 W Input voltage range (medium voltage version) 180-350 V Input voltage range (high voltage version) 260-500 V Input start-up voltage (medium/high voltage) 125 V / 250 V Max. input voltage range (medium/high voltage) Individual 450 V / 600 V string configuration Max. input voltage range (medium/high voltage) Parallel 410 V / 550V string configuration Max. input current at 40 C (medium voltage version) 10 A 2 x 10 A *) 2 x 10 A *) 3 x 10 A *) Max. input current at 40 C (high voltage version) 7 A 2 x 7 A *) 2 x 7 A *) 3 x 7 A *) Independent MPP trackers 1 2 2 3 Output Nominal output power at 25 C 1650 W 2750 W 3300 W 4600 W Max. output power (temperature dependent) 1800 W 3000 W 3600 W 5000/5400 W 1) Nominal output current 6.5 A 11.3 A 13 A 19 A Max. output current 8 A 13 A 15.5 A 23 A Max. efficiency 93.7 94.2 94.2 94.3 European efficiency, Master/Slave 91.6 92.9 93.4 93.4 Weight (incl. wall bracket) 14 kg 20 kg 20 kg 23 kg Dimensions L W H, mm (incl. wall bracket) 369 386 188 498 386 188 498 386 188 631 386 188 Table 3.2: Specification for ULX Inverters 1) Depending on country setting/adjustable. *) Max. 16 A per string. 12 L00410293-06_02

Danfoss Solar Inverters A/S Ulsnaes 1 DK-6300 Graasten Denmark Tel: +45 7488 1300 Fax: +45 7488 1301 E-mail: solar-inverters@danfoss.com www.solar-inverters.danfoss.com Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. Rev. date 2010-03-24 Lit. No. L00410293-06_02