AUTOMATE ARC CORD LIFT MOTORS

Similar documents
AUTOMATE VT 1.0 ARC VENETIAN BLIND TILT MOTOR

AVOUTLET.com SELECTABLE RPM

AUTOMATE Li-ion ARC TUBULAR MOTOR

AUTOMATE AC MECHANICAL LIMIT TUBULAR MOTOR

AUTOMATE FT MOTOR INSTRUCTIONS

MOTORIZED ROLLER SHADES PROGRAMMING GUIDE OTTO 30 OTTO DC2

MOTORIZED ROLLER SHADES PROGRAMMING GUIDE OTTO RECHARGE OTTO RECHARGE PLUS OTTO RECHARGE MAX

AUTOMATE Li-ion Solar Charging Power Panel

MOTORIZED ROLLER SHADES OTTO WIRED 6 PROGRAMMING GUIDE

Remote Programming Guide

7C MERGER M40/50RF SYSTEM INSTALLERS GUIDE

Sonesse 30 WireFree RTS. Instructions

M40/50RF System - Installers Guide

ADVANCED MOTORIZATION TECHNOLOGY AUTOMATE. rolleaseacmeda.com

ADVANCED MOTORIZATION TECHNOLOGY AUTOMATE. rolleaseacmeda.com

G+ LOCKSET. User Guide

Dry Contact Closure Interface

Sectional And Tilting Door Opener

X Cube Lift. Model: XCU 190 XCU 180 Installation Instructions

Sectional and Tilting Door Opener

GEIGER GJ56.. AIR (GJ56.. F03) for Venetian blinds

WireFree. Battery Powered Motorisation For Interior Window Coverings

Porte 300 Users Manual Swing Gate Opener 24V DC for residential use only

Porte 150 Users Manual Swing Gate Opener 24V DC

ROMANS. SS38 Chain Control

Scissor Lift Model : SC60 SC40 Installation Instructions

AXA DALI P20. DALI Broadcast Controller. Installation Manual

Auto-Lift Operating System

PowerPlex 40V MAX Standard Battery Pack/Charger

Installation and User Manual. with RAIN SENSOR.

Eff. date June 15, Updated

MP V 8A Electronic Smart Charger. Instruction and Information Manual

Sectional and Tilting Door Opener Installation Instructions and User Guide

Made to Measure Window Furnishings

p wered BLINDS control at your fingertips Installation, Programming & Operation Guide 12Vdc Powered Roman Blind

INSTALLATION INSTRUCTIONS. - Spring Loaded Tube - Beaded Chain Loop - Cordless

DUETTE POWERRISE SHADES

Instruction Manual MB4 Rolling garage door opener

R3 Roller Garage Door Opener

SECTIONAL AND TILTING DOOR OPENER INSTALLATION INSTRUCTIONS AND USER GUIDE. Comfort 800E/1000E

9-I DUETTE SHADES POWERVIEW MOTORISATION

Solar & Roller Shades

Instruction Manual LA-SDO1 Sectional garage door opener

Owner and Operating Manual for

Reliable. Affordable. Rechargeable.

MB V 3-IN-1 JUMP STARTER WITH SPIRAL WOUND BATTERY

Instruction manual Electric glass door lock Touch-to-open

INSTALLING YOUR MOTORIZED ROLLER/SOLAR SHADE

OpenEVSE - 40A Charging Station

LUXAFLEX DUETTE Shades with Hard-Wired Motorisation. Installation Operation Care

15Amp Intelligent Battery Charger Suitable for SLA, Gel, Maintenance Free, AGM, Deep Cycle batteries

Rolling Door Opener INSTALLATION INSTRUCTION AND OWNERS MANUAL

RECHARGEABLE PORTABLE EVAPORATIVE COOLER

Pedelec Operating Instructions Pedelec handleiding Pédélec manuel

WheelieSafe. WheelieSafe. User Manual. Motorized Trolley. Distributor:

FREEWAY RANGE OWNERS MANUAL. All PowaKaddy electric trolleys have been awarded the Quiet Mark by the Noise Abatement Society

c-go 24V/6A 24V/8A 24V/12A

STRX-9 100% TAKE CONTROL INSTRUCTION MANUAL READY-TO-RUN. w/ Adult Supervision

C3 Operating Instructions

Serena Remote Controlled Shades

Roll Up WireFree IR. Installation instructions

EDR G /03

Solar & Roller Shades

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

GENERAL SAFETY... 3 PARTS LIST...

GEIGER-GJ56.. with mechanical end stop For Venetian blinds and exterior blinds

Solar & Roller Shades

SL2380. Installer s guide. Owner skit. Blind control device Battery module.

Adjustable speed for opening and closing Possibility to set different speed levels for opening and closing.

IMPORTANT SAFEGUARDS

R18SPL. ORIGINAL INSTRUCTIONS 18V Dual Power LED Spotlight

Universal Battery Charger Cat. No.: Instruction Manual

Battery Charger JCB- SCH20LI.2

FOR New Electric Kit and Remote Control Installation

smithandnoble.com

STEP BY STEP INSTALLATION INSTRUCTIONS. Honeycomb Shades. Motivia Motorization

GEIGER-GJ5610v1 with mechanical end stop For Venetian blinds and exterior blinds for 100 V power supply

Oscillating Tower Fan with Remote Control

TWO-WAY LED AUTOMATIC TRANSMISSION REMOTE STARTER. User Guide WARNING

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

INSTRUCTIONS. Power Panel. Installation Instructions

Instruction Manual LA-SDO1 Sectional garage door opener

Table Of Contents. Motor Selection Guide Installation Instructions Operators 20-32

RLM36X40H25 ORIGINAL INSTRUCTIONS. Cordless Lawn Mower

Instruction Manual 03

INSTALLATION INSTRUCTIONS SLIDING SHUTTER MOTOR

Solar Powered Wireless Temperature Station & Sensor

P1110-EVAL-PS. PowerSpot RF Wireless Power Development Kit for Battery Recharging. User Manual

TRACER. User Manual. Model: PFBD97

Digital Electronic Torque Wrench. Operating Manual. Model 60648

STL K-Force 18 and Micro 14 LED Mini Light Bar

STL Ceptor Series Running Board Light Stick

Battery-Powered Motorized System

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

CAUTION. Disconnect Power

TWO-WAY LED MANUAL TRANSMISSION REMOTE STARTER. User Guide WARNING

GLM SERIES CONTROL Users Manual Rev:

Types of Doors that can be automated using the digi.one: Sectional overhead doors, single/double, steel or timber. Tip up doors, steel or timber.

CordLift WireFree CL32 RTS. Tilt WireFree RTS. Roll Up WireFree RTS. HOME MOTION by

300 Amp Battery Jumper

Transcription:

AUTOMATE ARC CORD LIFT MOTORS Part number Description MTDCRF-CL-0.6-50 CL 0.6Nm Cord Lift Motor MT01-3001-069001 CL 0.8Nm Cord Lift Motor 433 MHZ BI-DIRECTIONAL ELECTRONIC LIMIT SELECTABLE RPM FAVORITE POSITION LEVEL CONTROL AUTOMATE ARC Cord Lift motors enable motorized function of shades utilizing cord take up systems. The Leveling Control allows for precise positioning of individual or multiple shades ensuring perfect alignment every time. Additionally, a favorite position can be pre-set and recalled at any time. FEATURES: Smart Home Control IOT Integration Electronic Limits 433 MHz Bi-Directional RF Communication CL Motor_PRGM_GL_v1.0 DEC 2017 Leveling Control 3 x Selectable Rpm Favorite Position Roller & Tilt Modes.

NOTES 2 Automate Programming Instructions ARC Cord Lift Motors ROLLEASE ACMEDA

CONTENTS 1 ASSEMBLY 5 1.1 0.6 Nm Motor 5 1.2 0.8 Nm Motor 6 2 WIRING 7 2.1 Power Option 7 3 P1 BUTTON FUNCTIONS 8 3.1 Motor State Test 8 3.2 Motor Configuration Options 8 4 INITIAL SET-UP 9 4.1 Pair Motor with controller 9 4.2 Check motor direction 9 4.3 Set limits 10 5 ADJUSTING LIMITS 11 5.1 Adjust upper limit 11 5.2 Adjust lower limit 11 6 ADDING OR REMOVING CONTROLLERS AND CHANNELS 12 6.1 Using motor P1 button 12 6.2 Using a pre-existing controller 12 7 FAVORITE POSITIONING 13 7.1 Set favorite position 13 7.2 Send shade to favorite position 13 7.3 Delete favorite position 13 8 ADJUSTING 0.8NM MOTOR SPEED 14 8.1 Increase or decrease 0.8Nm motor speed 14 9 TILT & ROLLER MODE 15 9.1 Enter tilt mode 15 9.2 Enter roller mode (Default) 15 10 SLEEP MODE 16 10.1 Enter sleep mode 16 10.2 Exit sleep mode 16 11 TROUBLESHOOTING 17 3 Automate Programming Instructions ARC Cord Lift Motors ROLLEASE ACMEDA

SAFETY INSTRUCTIONS WARNING: Important safety instructions to be read before installation. Incorrect installation can lead to serious injury and will void manufacturer s liability and warranty. CAUTION Do not expose to moisture or extreme temperatures. Do not allow children to play with this device. Use or modification outside the scope of this instruction manual will void warranty. Installation and programming to be performed by a suitably qualified installer. For use within tubular blinds. Ensure correct crown and drive adaptors are used for the intended system. Keep antenna straight and clear from metal objects Do not cut the antenna. Use only Rollease Acmeda hardware. Before installation, remove any unnecessary cords and disable any equipment not needed for powered operation. Ensure torque and operating time is compatible with end application. Do not expose the motor to water or install in humid or damp environments. Motor is to be installed in horizontal application only. Do not drill into motor body. The routing of cable through walls shall be protected by isolating bushes or grommets. Ensure power cable and aerial is clear and protected from moving parts. If cable or power connector is damaged do not use. Important safety instructions to be read prior to operation. It is important for the safety of persons to follow the enclosed instructions. Save these instructions for future reference. Persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge should not be allowed to use this product. Keep remote controls away from children. Frequently inspect for improper operation. Do not use if repair or adjustment is necessary. Keep motor away from acid and alkali. Do not force the motor drive. Keep clear when in operation. Do not dispose of in general waste. Please recycle batteries and damaged electrical products appropriately. 5005833 4 Automate Programming Instructions ARC Cord Lift Motors ROLLEASE ACMEDA

1 ASSEMBLY 1.1 0.6 Nm Motor The 0.6Nm Automate Cord Lift motor must be installed flush with the end cap. Step 1. Secure the shaft adapter to the shaft with a grub screw. Step 2. Attach Headrail Adapters to the motor (2 each required). Step 3. Attach the shaft with adapter to the Motor assembly. Step 4. Insert Motor assembly into the headrail. Ensure shaft adapter full engages motor drive recess. Step 5. Ensure power cord and antenna extend freely from the headrail. Anchor the Motor to the headrail. 5 Automate Programming Instructions ARC Cord Lift Motors ROLLEASE ACMEDA

1.2 0.8 Nm Motor The 0.8Nm Automate Cord Lift motor can be installed at any position inside the aluminum extrusion. Step 1. Secure the shaft adapter to the shaft with a grub screw (2 assemblies required). Step 2. Attach Headrail Adapters to the motor (2 each required). Step 3. Attach the shaft with adapter to the Motor assembly. Step 4. Insert Motor assembly into the headrail. Ensure shaft adapter fully engages with the motor drive recess. Step 5. Ensure power cord and antenna extend freely from the headrail. Anchor the Motor to the headrail where desired. 6 Automate Programming Instructions ARC Cord Lift Motors ROLLEASE ACMEDA

2 WIRING 2.1 Power Option Automate DC motors are powered from a 12V DC power source. AA Battery wands, re-chargeable battery packs and A/C Adapters are available, with a variety of quick connect extension cords. For centralized installations, power supply range can be extended with 18/2 wire (not available through Rollease Acmeda). During operation, if voltage drops to less than 10V, the motor will beep 10 times to indicate a power supply issue. Motor will stop running when the voltage is lower than 7V and it will resume again when the voltage is greater than 7.5V. DC Power Supply Power Supply Motor MTBWAND18-25 Battery Tube for DCRF (no Battery) Motors MTDCPS-18-25 Power Supply for 18/25-CL/Tilt DCRF (no Bttry) Motor MTDCRF-CL-0.6-50 MT01-3001-069001 MTBPCKR-28 Rechargeable Battery Pack Extension Cables MTDC-CBLXT6 DC Battery Motor Cable extender 6 / 155mm MTDC-CBLXT48 DC Battery Motor Cable extender 48 / 1220mm MTDC-CBLXT96 DC Battery Motor Cable extender 96 / 2440mm Length 6 inch 48 inches 96 inches Ensure cable is kept clear of fabric. Ensure antenna is kept straight and away from metal objects. 7 Automate Programming Instructions ARC Cord Lift Motors ROLLEASE ACMEDA

3 P1 BUTTON FUNCTIONS 3.1 Motor State Test This table describes the function of a short P1 button press/release(<2 seconds) depending on current motor configuration. P1 Press Condition Function Achieved Visual Feedback Audible Feedback Function Described If limit is NOT set None No Action None No Action Short Press then Release If limits are set Operational control of motor, run to limit. Stop if running Motor runs None Operational control of motor after pairing and limit setting is completed first time (<2 sec) If motor is in Sleep Mode & limits are set (Refer to Sec.10) Wake and control Motor wakes and runs in a direction None Motor is restored from Sleep mode and RF control is active 3.2 Motor Configuration Options The P1 Button is utilized to administer motor configuration as described below and beginning in Section 4. Activate Pairing Mode Hold P1 P1 RELEASE P1 Sleep Mode 6 SECS RELEASE P1 Reverse Direction 0.6 Nm Motor 0.8 Nm Motor RELEASE P1 Reset To Factory Settings 14SECS 8 Automate Programming Instructions ARC Cord Lift Motors ROLLEASE ACMEDA

4 INITIAL SET-UP 4.1 Pair Motor with controller Select channel on controller. (Disregard if using single channel controller) Hold P1 button on motor head Hold STOP on controller IMPORTANT Consult user manual for your controller for information on selecting channel. RELEASE P1 Motor is now in setup mode and ready for setting limits. 4.2 Check motor direction To check travel direction of shade, press UP or DOWN on controller. To reverse shade direction, hold both UP and DOWN until motor responds Motor Reponse Reversing motor direction using this method is only possible during initial set-up, prior to first time limit setting, or after a re-set of motor 9 Automate Programming Instructions ARC Cord Lift Motors ROLLEASE ACMEDA

4.3 Set limits IMPORTANT Damage to shade may occur when operating motor prior to setting limits. Attention should be given. To save upper limit, hold UP and STOP. Move shade to the desired highest or lowest position by pressing the UP or DOWN buttons on controller. To save lower limit, hold DOWN and STOP. Quick Press = Step Long Press = Continuous Travel 5 SECS Initial set-up is now complete 10 Automate Programming Instructions ARC Cord Lift Motors ROLLEASE ACMEDA

5 ADJUSTING LIMITS 5.1 Adjust upper limit Hold UP and STOP on Controller until the motor responds. Move shade to the desired upper position by pressing the UP or DOWN button. To save upper limit, hold UP and STOP until the motor responds. SECS 5.2 Adjust lower limit Hold DOWN and STOP on controller. Move shade to the desired lowest position by pressing the UP or DOWN button To save lower limit, hold DOWN and STOP. SECS IMPORTANT Consult user manual for your controller or sensor. 11 Automate Programming Instructions ARC Cord Lift Motors ROLLEASE ACMEDA

6 ADDING OR REMOVING CONTROLLERS AND CHANNELS 6.1 Using motor P1 button Hold P1 button on motor head. Hold STOP on controller to add or remove RELEASE P1 6.2 Using a pre-existing controller A= Existing controller or channel (to keep) B= Controller or channel or add or remove Press P2 on existing controller. Press P2 on existing controller. Press P2 on new controller. 12 Automate Programming Instructions ARC Cord Lift Motors ROLLEASE ACMEDA

7 FAVORITE POSITIONING 7.1 Set favorite position Move shade to the desired position by pressing the UP or DOWN button on the controller. Press P2 on controller. Press STOP on controller. Press STOP on controller. 7.2 Send shade to favorite position Hold STOP on controller. 7.3 Delete favorite position Press P2 on controller. Press STOP on controller. Press STOP on controller. 13 Automate Programming Instructions ARC Cord Lift Motors ROLLEASE ACMEDA

8 ADJUSTING 0.8NM MOTOR SPEED 8.1 Increase or decrease 0.8Nm motor speed Press P2 on controller. Press DOWN Press DOWN IMPORTANT If motor does not react to speed adjustment, the maximum or minimum speed has already been reached. 14 Automate Programming Instructions ARC Cord Lift Motors ROLLEASE ACMEDA

9 TILT & ROLLER MODE 9.1 Enter tilt mode Hold UP and DOWN on controller. Press STOP 5 SECS For slat adjustment on Venetians. 9.2 Enter roller mode (Default) Hold UP and DOWN on controller. Press STOP 5 SECS 15 Automate Programming Instructions ARC Cord Lift Motors ROLLEASE ACMEDA

10 SLEEP MODE 10.1 Enter sleep mode Sleep mode is utilized to prevent a motor from moving during shipping of a fabricated shade. Hold P1 button on motor head. 6 SECS RELEASE P1 10.2 Exit sleep mode Exit sleep mode once shade is installed. PRESS & RELEASE P1 button on motor head. MOTOR RUNS TO LIMIT 16 Automate Programming Instructions ARC Cord Lift Motors ROLLEASE ACMEDA

11 TROUBLESHOOTING Problem Cause Remedy Motor is not responding Unable to adjust or set limits. Cannot program a single Motor (multiple motors respond) A / C Adapter not plugged in. Battery in motor is depleted Power failure Transmitter battery is discharged Battery is inserted incorrectly into transmitter Radio interference/shielding Receiver distance is too far from transmitter Incorrect wiring Remote is in a locked state. Multiple motors are paired to the same channel. Check motor to power cable connection and AC plug. Replace 8xAA alkaline batteries. Check power supply to motor is connected and active Replace battery Check battery polarity Ensure transmitter is positioned away from metal objects and the aerial on motor or receiver is kept straight and away from metal Move transmitter to a closer position Check that wiring is connected correctly (refer to motor installation instructions) Change remote status to an unlocked state Always reserve an individual channel for programming functions SYSTEM BEST PRACTICE - Provide an extra 15 channel remote in your multi motor projects, that provides individual control for each motor for programming purposes Place all other motors into sleep mode (ref to P1 function overview - section 3.2 and 10.1) 17 Automate Programming Instructions ARC Cord Lift Motors

ROLLEASE ACMEDA AUSTRALIA 110 Northcorp Boulevard, Broadmeadows VIC 3047 T +61 3 9355 0100 F +61 3 9355 0110 Queensland Branch Unit 2/62 Borthwick Avenue, Murarrie QLD 4172 ROLLEASE ACMEDA USA 200 Harvard Avenue Stamford, CT 06902 6320 T +1 203 964 1573 F +1 203 964 0513 ROLLEASE ACMEDA EUROPE Via Conca Del Naviglio 18, Milan (Lombardia) Italy T +39 02 8982 7317 F +39 02 8982 7317 info@rolleaseacmeda.com rolleaseacmeda.com 18 Automate Programming Instructions ARC Cord Lift Motors