All-in-one Storage Hybrid System The priority of power supply for battery and AC can be settable; There is no gap to switch between on-grid and off-grid in 0ms,and it will never go offline; Efficient Built-in lithium battery, and the capacity of.-kwh can be configured. Smart Reliable The mode of on-grid and off-grid can be automatically determined and then it can be connected to the smart grid to realize the function of peak-saving and valley-filling and self-use; A variety of communication modules, such as RS8*, CAN*(with lithium battery), Wifi (optional); The charging and discharging time of the machine can be settable; The capacity of grid-connected output power can be settable. Professional energy management system, three-stage charging function, and compatible with lead-acid and lithium battery; To adjust the charging current via various battery types; Friendly man-machine interface, and with. inch LCD display; P protection level. Negative Positive CAN COM 8 8 PV RS8
Specification BDKTL-TD BDKTL-TD DC input (PV) Max. DC input power (W) 00 00 Max. DC input voltage(v) 0 Starting voltage (V) / Min. operation voltage (V) 00/80 0~0 MPPT Range (V) Max. input current (A) A A Number of MPPT /String per MPPT / / Short circuit current (A).. 000 00 AC output (grid) Rated power (W) 08/0/0/0 single phase Rated grid voltage (V) 0/0 Rated grid frequency (Hz) 80~0 voltage range (V) ~/~ voltage frequency (Hz) Rated output current (A) 0 0.99 (±0.9adjustable) Power factor %(ar rated power) THDi Max. efficiency 9.0% 9.0% Euro-efficiency 9.0% 9% AC output () Rated output power (VA) 000 000 08/0/0/0 ±% Rated output voltage (V) 0/0 ±0.% Rated output frequency (Hz) Off-network switching time 0ms Voltage harmonic distortion %(rated power) 0%/0S Peak power/duration Battery 8 Rated voltage (V) 0-0 Voltage range(settable) (V) Lithium battery or Lead-acid battery Battery type.kwh-kwh(adjustable Battery capacity Max. charging current(settable) (A) 0 00 Max. discharging current(settable)(a) 0 00 Max. efficiency 9% Others Isolation method (photovoltaic side) Not isolation Isolation method (battery side) High-frequency isolation Range of working temperature - ~ +0 0 derating begins Cooling method topology Degree of protection /Altitude (m) Relative humidity Air cooling IP/ <000m; 0~9%, no condensation Noise (db) 0 Protection PV array insulation protection, PV array leakage current protection, Ground fault monitoring, monitoring, Island protection, DC monitoring, Short current protection etc. Display LCD Communication interface Dimension (H x W x D mm) Weight (kg) Installation standard Ground fault alarm Safe certificate /EMC certificates Factory warranty (years 00*0*0 98. Standing VDE-AR-N0 AS/NZS.:0 NB/T 00-0 Built-in buzzer IEC 09-00 IEC 09-0 EN 000--: 00 (standard) / (optional)
US000B Lithium Iron Phosphate Battery Features Support parallel application; The maximum charge and discharge rate reaches C; Awarded by TUV (IEC9),CE, and UN8.; With various communication modules: RS-8, CAN. And we can know of the station of battery whenever through such monitoring modes; Real-time monitoring, providing short circuit protection, reverse connection protection, high voltage protection, low voltage protection, charge over current protection, discharge over current protection, over charge protection and over discharge protection, high temperature protection as so on. US000B Lithium Iron Phosphate Battery 0-8-9-9 0- - Ground 8 CAN 0- Negative POWER(ON/OFF) 9 RS8 IN+ GND N0 COM - Positive Power LED 0 Link Port 0 8 9 Soft-start Switch Link Port NO COM NO COM ADD Status LED RS
Specification Items Remarks Standard voltage 8V Rated capacity 0Ah Charging ways 0.C constantly charging to stop value 0.0C Size(mm): 0*0*89 Weight(kg): Rated discharging value A Discharge voltage(v) ~V Charge Voltage (V).~ Discharging protection current A Rated charging current Charging protection current 00A Charge max voltage poing ±0.V Delay s protection, delay min after protection and recovery of discharging current immediately Suggest charging voltage.±0.v.±0.v Charge min voltage Work temperature Delay s protection, delay min after protection and recovery of charging current immediately 00A Charge Discharge Commnication -0~0-0~0 RS,RS8,Can TUV/CE/Un8./TLC Life humidity Storage temperature Circles >0years ( /F) %~9% - ~ 000
Work Mode PV grid-connected mode: PV to Battery to PV & Battery grid-connected mode: PV & Battery to Battery grid-connected mode: Battery to PV & Battery Charging mode: PV & to Battery Line Charging mode: to Battery PV Charging mode: PV to Battery Discharge mode: Battery to