Job Name: Tag# Submittal Data Sheet FTX30NVJU / RX30NMVJU 2.5-Ton Wall Mounted eat Pump System Efficiency SEER EER eating 17.5 9.85 SPF COP 9.3 2.92 Performance (Btu/hr) Rated (Min/Max) Sensible @ ARI Standard Operating Range Extended Operating Range* 31,400 (10,200 / 31,400) 21,030 50 F 115 F -4 F 115 F Rated Conditions: Indoor: 80 F DB/67 F WB Outdoor: 95 F DB/75 F WB *With field settings and wind baffle eating (Btu/hr) Complete warranty details available from your local dealer or at www.daikincomfort.com. Warranty registration not required to receive the 10-Year parts limited warranty for residential or commercial installations. 890 L 572 eating M 727 SL 512 960 L 629 M 791 SL 544 Outdoor Specifications Airflow Rate (cfm) Sound Pressure Level (dba) Dimensions ( W D) (in) Weight (Lbs) ermetically Sealed Swing Type R-410A 3.64 PVE (FVC50K) 2,528 1: Rated eating Conditions: Outdoor: 47 F DB/43 F WB Outdoor: 17 F DB/15 F WB Outdoor: 5 F DB/5 F WB 3: Rated eating Conditions: Sound (dba) 53 / 47 / 40 / 37 53 / 46 / 38 / 35 / M / L / SL Dimensions ( W D) (in) 13-3/8 47-1/4 10-3/16 Weight (Lbs) 38 Compressor Refrigerant Factory Charge (Lbs) Refrigerant Oil 34,800 (10,200 / 34,800) 22,400 15,550 5 65 F 2: Rated eating Conditions: Indoor Specifications Airflow Rate (cfm) 1:@ 47 Rated (Min/Max) 2: @ 17 Rated 3: @ 5 Max Operating Range eating 2,274 56 / 58 28-15/16 34-1/4 12-5/8 133 Electrical System MCA System MFA Compressor RLA Outdoor fan motor FLA Outdoor fan motor W Indoor fan motor FLA Indoor fan motor W 208/60/1 19.8 20 18.25.62 93.37 64 230/60/1 19.8 20 18.25.62 93.37 64 MFA: Max. fuse amps MCA: Min. circuit amps (A) FLA: Full load amps (A) RLA: Rated load amps (A) W: Fan motor rated output (W) Piping Liquid (in) Gas (in) Drain (in) Max. Interunit Piping Length (ft) Max. Interunit eight Difference (ft) Chargeless (ft) Additional Charge of Refrigerant (oz/ft) 1/4 5/8 5/8 98.4 65.625 32.8.32 Daikin North America LLC 5151 San Felipe, Suite 500 ouston, TX 77056 Submittal Revision Date: May 2018 Page 1 of 4
FTX30NVJU Dimensional Data Daikin North America LLC 5151 San Felipe, Suite 500 ouston, TX 77056 Submittal Revision Date: May 2018 Page 2 of 4
RX30NMVJU Dimensional Data Daikin North America LLC 5151 San Felipe, Suite 500 ouston, TX 77056 Submittal Revision Date: May 2018 Page 3 of 4
Optional Accessories Indoor Unit Included Part Number Description BRP072A43 Wireless Interface Adapter BRC944B2-A08 Wired Remote Controller kit BRCW901A08 Wired Remote Controller Cable 25 ft (included in above kit) BRCW901A03 Wired Remote Controller Cable 10 ft DACA-TS1-1 Daikin ENVi Intelligent Thermostat Kit DACA-CP1-1 Inline Condensate Pump (Fits inside all Daikin wall & floor mount units) DACA-CP4-1 External Condensate Pump KRP928BB2S Interface Adaptor for DIII-NET Outdoor Unit Included Part Number Description KE063A4E Drain Pan eater (RX) KPW063A4 Air Adjustment Grille (RX & RK) KKG063A42 Back protection wire net Daikin North America LLC 5151 San Felipe, Suite 500 ouston, TX 77056 Submittal Revision Date: May 2018 Page 4 of 4
Job Name: Tag# Submittal Data Sheet FTX36NVJU / RX36NMVJU 3-Ton Wall Mounted eat Pump System Efficiency SEER EER eating 15.9 9.10 SPF COP 9.2 2.78 Performance (Btu/hr) Rated (Min/Max) Sensible @ ARI Standard Operating Range Extended Operating Range* 34,400 (10,200 / 34,400) 22,160 50 F 115 F -4 F 115 F Rated Conditions: Indoor: 80 F DB/67 F WB Outdoor: 95 F DB/75 F WB *With field settings and wind baffle eating (Btu/hr) Complete warranty details available from your local dealer or at www.daikincomfort.com. Warranty registration not required to receive the 10-Year parts limited warranty for residential or commercial installations. 915 L 572 960 L 629 M 791 SL 544 Sound (dba) 54 / 47 / 40 / 37 53 / 46 / 38 / 35 / M / L / SL Dimensions ( W D) (in) 13-3/8 47-1/4 10-3/16 Weight (Lbs) 38 Outdoor Specifications Compressor Refrigerant Factory Charge (Lbs) Refrigerant Oil Airflow Rate (cfm) Sound Pressure Level (dba) Dimensions ( W D) (in) Weight (Lbs) ermetically Sealed Swing Type R-410A 3.64 PVE (FVC50K) 2,811 1: Rated eating Conditions: Outdoor: 47 F DB/43 F WB Outdoor: 17 F DB/15 F WB Outdoor: 5 F DB/5 F WB 3: Rated eating Conditions: eating M 742 SL 512 36,000 (10,200 / 36,000) 22,800 15,740 5 65 F 2: Rated eating Conditions: Indoor Specifications Airflow Rate (cfm) 1:@ 47 Rated (Min/Max) 2: @ 17 Rated 3: @ 5 Max Operating Range eating 2,352 59 28-15/16 34-1/4 12-5/8 133 Electrical System MCA System MFA Compressor RLA Outdoor fan motor FLA Outdoor fan motor W Indoor fan motor FLA Indoor fan motor W 208/60/1 19.8 20 18.25.83 123.37 64 230/60/1 19.8 20 18.25.83 123.37 64 MFA: Max. fuse amps MCA: Min. circuit amps (A) FLA: Full load amps (A) RLA: Rated load amps (A) W: Fan motor rated output (W) Piping Liquid (in) Gas (in) Drain (in) Max. Interunit Piping Length (ft) Max. Interunit eight Difference (ft) Chargeless (ft) Additional Charge of Refrigerant (oz/ft) 1/4 5/8 5/8 98.4 65.625 32.8.32 Daikin North America LLC 5151 San Felipe, Suite 500 ouston, TX 77056 Submittal Revision Date: May 2018 Page 1 of 4
FTX36NVJU Dimensional Data Daikin North America LLC 5151 San Felipe, Suite 500 ouston, TX 77056 Submittal Revision Date: May 2018 Page 2 of 4
RX36NMVJU Dimensional Data Daikin North America LLC 5151 San Felipe, Suite 500 ouston, TX 77056 Submittal Revision Date: May 2018 Page 3 of 4
Optional Accessories Indoor Unit Included Part Number Description BRP072A43 Wireless Interface Adapter BRC944B2-A08 Wired Remote Controller kit BRCW901A08 Wired Remote Controller Cable 25 ft (included in above kit) BRCW901A03 Wired Remote Controller Cable 10ft DACA-TS1-1 Daikin ENVi Intelligent Thermostat Kit DACA-CP1-1 Inline Condensate Pump (Fits inside all Daikin wall & floor mount units) DACA-CP4-1 External Condensate Pump KRP928BB2S Interface Adaptor for DIII-NET Outdoor Unit Included Part Number Description KE063A4E Drain Pan eater (RX) KPW063A4 Air Adjustment Grille (RX & RK) KKG063A42 Back protection wire net Daikin North America LLC 5151 San Felipe, Suite 500 ouston, TX 77056 Submittal Revision Date: May 2018 Page 4 of 4