Autoplex Specifications

Similar documents
ChemWell Replacement Parts & Accessories

DxC 700 AU Job Aid Booklet

prepare CALIBRAtIon PHOTO MANUAL FOR BACTIQUANT -WATER HIGH VOLUME PACKAGING 3. Use a black cuvette and a standard 4. Press CAL 5.

DYNABLOT Plus. Operating and maintenance manual. Instrument for the immunoblot processing. Rev. 8

AssayMAP 96AM Wash Station. Maintenance Guide

Standard Operating Procedure for Detecting MEA Triazine in a Crude Oil Matrix using LONESTAR TM

AssayMAP 96AM Wash Station. Maintenance Guide

MODEL 905V OPERATING INSTRUCTIONS

Ion PGM System with Reagent and Wash Bottles attached

Dilutor Module for TriPlus RSH

Troubleshooting. This section outlines procedures for troubleshooting problems with the operation of the system:

LED TROUBLESHOOTING. Controller Version L610 Rev 7M or newer (manufactured after 1/21/15)

HOW TO REPLACE THE ICHEMVELOCITY WASTE FILTER AND PERFORM THE WASTE LINE FLUSH FOR BECKMAN UA CALL CENTER USE

402 Dilutor Dispenser User s Guide

Eppendorf Repeater Pro Instruction Manual Manual de Instrucciones

Appendix B Print Head Maintenance Document Number: Released: Subject: Description: Materials: 0.1Cleaning Fluid Usage 0.1.

HPLC Model 210D. UV detector lamp switch. Rheodyne 7725i injection valve. Prime/purge valve. Column. compartment. thumbscrews. Storage.

Troubleshooting. CryoSmart 1 - CryoSmart 20

SERVICE MANUAL AC920 / AC970EO+

Physiological Calibration Standard II Calibration standard physiological fluid CALIBRATION STANDARD PROTEIN

Genesys 20 Calibration and Maintenance

We re Going Global. Washing walls, wall wash sounds the same? Yes, they do but they couldn t be more different.

Equipment Maintenance: Impact on Efficiency. Matt Killen, LACAP, Baton Rouge, LA

Prospenser. User Manual Mode d emploi Bedienungsanleitung Manual Usuario. For capacities of 2.5 ml 5 ml 10 ml 30 ml and 50 ml

VITLAB Dispenser. Standard Operating Procedure (SOP)

NovoCyte Flow Cytometer. Maintenance Guide

Agilent 7696A Sample Prep WorkBench Automated Sample Preparation for the GC Analysis of Biodiesel Using Method EN14105:2011

Preventive Maintenance...

Digital Burette. Assembly and operating instructions. For capacities of 30ml & 50ml

User Manual Electronic Titrator

INSTRUCTION MANUAL. Mi490 Peroxide value. Milwaukee Lab Photometer. Test Equipment Depot Washington Street Melrose, MA 02176

GeneXpert Maintenance

Micro 215 Liquid Handler User's Guide

SmartChip MyDesign Kit User Manual

FULL AUTOMATIC ASPHALTENE ANALYZER APD-500A USER S GUIDE

Micro-Injection System

Needle OD (mm) Needle ID (mm) Needle Gauge

FTM-L SERIES SINGLE OR TWIN DIRECT STEAM MIXER KETTLE COMPLETE WITH HYDRAULIC POWER TILT BRIDGE PARTS AND SERVICE MANUAL

QUALITY ASSURANCE & LAB ACCREDITATION

SETTING ZERO S cont. IF THE ZERO REPEATS WITHIN +/- 1.0 LB THEN YOU ARE READY TO CHECK SPRINGS. PAGE 4 OF 9

SPE-DEX 4790 Solid Phase Extraction System

User Maintenance Kit

Miniature Inert PTFE Isolation Valves. Physical Properties Electrical Performance Characteristics

Daily T-Jet2 TM Maintenance Procedures January 2007 Ver1.1

Dispensette. Testing Instructions (SOP) 1. Introduction. May 2009

S 1125 HPLC Pump System

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

BE 20 IMI Cornelius Orange Juice Dispenser Model Quest Elite QLT 2000

IT SIMPLY WORKS. WARRANTY LINE. // Products and accessories for A/C and cooling systems

Operation Manual BOTTLE TOP DISPENSER

CRD600 Automatic Fitting Inserter

Electrophoresis Sample Handler

Statim G4 Error Codes

Operation Guide. Operation Guide. Winnebago Hydraulic Leveling Systems by Kwikee. Introduction. Table of Content WARNINGS

Atomic Absorption Spectroscopy

Automatic Pill Dispenser. (Model 3/07) Instructions

P249E-CLOSED LOOP SCR REDUCTANT INJECTION CONTROL AT LIMIT - FLOW TOO HIGH

CRD610 Automatic Fitting Inserter

The Importance of Liquid Handling Details and Their Impact on your Assays

ppbrae & MiniRAE 2000 Service Training Firmware v 1.25(rev B)

NEW HPLC - SYSTEM LINE

Agilent 7693A Automated Liquid Sampler

VOC Duct and Rough Service Sensor

SD Bendix M-21 and M-22 AntiLock Modulator Assembly DESCRIPTION M-21 MODULATOR M-22 MODULATOR

Service Manual Gulf Stream Electronic Full Wall Slide Systems

Table top-mobile-power lift INSTRUCTIONS AND SPARE PARTS

VS403 INSTRUCTIONS FOR: VACUUM AND PRESSURE TEST / BRAKE BLEEDING UNIT MODEL: SAFETY INSTRUCTIONS INTRODUCTION & CONTENTS. fig.1

AgXcel GX5 Install Guide for Integration into Trimble. where precision meets the soil... PO Box 1611 Kearney, NE

Agilent 7693A Automated Liquid Sampler

MDP 1000 OPERATING INSTRUCTIONS PUMP MDP 1000 OPERATING INSTRUCTIONS

Product Loss During Retail Motor Fuel Dispenser Inspection

XP-300 MAINTENANCE LOG

DURAN GROUP DISPENSER & DURAN GROUP DISPENSER PRO. A safe and precise dispensing system

Mobile Column Lift Set

Newcastle Weighing Services Pty Ltd

PowerLevel s e r i e s

These protocols are compiled from the literature from Biacore AB. These protocols apply to the Biacore 2000/3000 instruments and software

Periodic Maintenance 7-1

Kelsey-Hayes Brake Pressure Differential Valve Rebuild

1. INTRODUCTION AND SYSTEM DESCRIPTION BLOCK DIAGRAM GENERAL INFORMATION GLOSSARY... 7

BAT/IS-system for Pore pressure measurement

Model : LMHS-60 Please read this manual carefully before using the instrument Labnics Equipment

economics and performance Spark Holland introduces OPTIMAS The optimum balance of BETTER SAMPLE CARE

RAPID OIL TEST GAUGE

WalkLAB Digital Dissolved Oxygen meter HD9030

7. OEM HANDLING INSTRUCTIONS FOR GXV340 GXV390 ENGINES

Technical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS)

Cold Vapor Mercury Apparatus* Purpose Figure 1 Cold Vapor Mercury Apparatus Assembly Overview

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

(2) Blank Cover Plates. (2) Light Plates. (2) J Bolts

NEW INSTRUMENT. 08th November / MKT. We announce the launching of the new member of the Biokit Elisa Instrumentation family: DS2

Rapid Digestor Fume Removal System

N E W! The next generation Digital Burette.

INSTALLATION INSTRUCTIONS UNIVERSAL HEADACHE RACK

235/235P Autoinjector User's Guide

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

9. WARRANTY INFORMATION

Glide-Line Lift and Rotate Unit (LRU)

MOOG Medical Devices Group Curlin 6000 Series Ambulatory Infusion Pump PATIENT GUIDE

Transcription:

Autoplex Specifications Autoplex G1 w/heating coil Stainless steel tip holds up to 150µl of liquid Probe tubing holds up to 3.18ml of liquid (length=88in, diameter=0.673mm/0.053in, 36.1µl/inch-high surface area) Autoplex G2 w/o heating coil Stainless steel tip holds up to 150µl liquid Probe tubing holds up to 2.35ml of liquid (length=65in, diameter=0.673mm/0.053in) System Reagent Usage/Content based on software settings when running a FULL plate assay (12 strips) Software Settings Strategy: Mode1 or Skip redundant wash probes is CHECKED and Save Reagent ON Probe Content: o Extra reagent used = 100µl x 12 = 1200µl = 1.2ml = 1.2ml + 9.6ml = 10.8ml o Max Probe Content = (extra reagent) + (strip 12 reagent volume dispensed) = 1.2ml + 0.8ml = 2.00ml Does NOT exceed probe capacity and Save Reagent OFF Probe Content: 160µl x 12 = 1920µl/1.92ml extra reagent used; total volume required = (extra reagent) + (reagent volume dispensed) = 1.92ml + 9.6ml = 11.52ml; max Probe volume = o Extra reagent used = 160µl x 12 = 1920µl = 1.92ml = 1.92ml + 9.6ml = 11.52ml o Max Probe Content = (extra reagent) + (strip 12 reagent volume dispensed) = 1.92ml + 0.8ml = 2.72ml Does EXCEED probe capacity Large syringe stroke error Error eliminated in software v.6.4.1.753 or later Software Settings Strategy: Mode0 or Skip redundant wash probes is NOT CHECKED and Save Reagent ON Probe Content: o Extra reagent used = 100µl x 12 = 1200µl = 1.2ml = 1.2ml + 9.6ml = 10.8ml o Max Probe Content = (strip 12 extra reagent) + (strip 12 reagent volume dispensed) = 100µl + 800µl = 900µl Does NOT exceed probe capacity and Save Reagent OFF Probe Content: o Extra reagent used = 160µl x 12 = 1920µl = 1.92ml = 1.92ml + 9.6ml = 11.52ml o Max Probe Content = (strip 12 extra reagent) + (reagent volume dispensed for strip 12) = 160µl + 800µl = 960µl Does NOT exceed probe capacity Plate Washer Tubing Volume o Bottle to Machine = 3.32ml o Valve System = 3.97ml o Valve system to Wash head = 6.27ml Total Tubing Volume = 13.56ml

Start of the Day Routine Software v.6.4.1.745 and earlier o Lamps are turned on (LPON) o Photometer is blanked to air (RAIR) o Dilutor is initialized (syringes rehomed)(dini) o Probe washed 2x with 2ml water (total 4ml) (2x WPRB2000) o Plate Wash System is primed 2x with wash bottle fluid (2x 6ml = 12ml total) (2x WPRI) Software v.6.4.1.753 and later o Lamps are turned on (LPON) o Photometer is blanked to air (RAIR) o Dilutor is initialized (syringes rehomed)(dini) o Probe washed 4x with 2ml water (total 8ml) (4x WPRB2000) o Plate Wash System is primed 2x with wash bottle fluid (2x 6ml = 12ml total) (2x WPRI) Prime Syringe Routine Software v.6.4.1.745 and earlier o Probe washed 1x with 2ml water (total 2ml) (1x WPRB2000) Software v.6.4.1.753 and later o Probe washed 3x with 2ml water (total 6ml) (3x WPRB2000) Prime Wash/Rinse Bottle Routine All Software versions (to date) o Plate Wash System is primed 2x with bottle fluid (2x 6ml = 12ml total) (2x WPRI)

Autoplex Regular Maintenance Monobind Recommendations DAILY: Start of the Day Routine o Visually check the flow of fluids through the wash system and the probe. If the fluid flow is not steady and even, perform additional Prime Syringes and/or Prime Washer Wash Bottle End of the Day Routine WEEKLY: Waste Container: o Wash out the waste container prior to performing any other Plate Wash Apparatus o Prime/clean the wash system by washing a full plate; see steps below. o Procedure: 1) Place a blank or old/used, empty plate in the machine 2) In the Autoplex manager, go to tab 3 Confirm Layout 3) Next to the picture of the plate layout, select All Rows to select all rows of the plate 4) After verifying a plate is in the machine, press the Wash button at the bottom of the plate layout picture. 5) Wait for the machine to wash all 12 strips of the plate and proceed with remaining.

MONTHLY: Self Test o This is performed to check the performance of the instrument, including accuracy and precision. If the test fails, perform all of the below and re-run. If the test fails again after all the is performed, contact technical support. Alignment o Typically alignments hold for several months, but it is good practice to check these regularly. o The Alignments can be accessed under the Utilities menu.

o Probe vs. Rack 1/2: The probe should be set 1-2mm above the rack pins o Probe vs. Plate: The probe to plate dispense height should be set such that the probe lightly touches the center of the well bottom. o Washer vs. Plate: Check that the washer is level with respect to the well bottoms A-H. The wash head should be set to lightly tap the well bottoms during the alignment procedure. Wash Head o Remove the wash head and clean each probe with the cleaning needle provided in the spare parts kit. Then run DI water through both luer fittings of the wash head to clear/rinse out any residue and ensure a steady, even flow of fluid. o Re-attach the wash head properly and prime the wash system. Syringes o Remove both syringes and work them manually to check for even and sufficient amounts of resistance. Replace if too loose or uneven resistance. Alcohol Cleaning of System o Cleaning the system with 70% Isopropyl alcohol helps to clear the syringes and tubing of any air bubbles or contamination. This regular cleaning helps with accuracy and precision. An alternative 0.1N HCl solution can also be used for decontamination by following the same procedure below. o Procedure: Replace the Prime Bottle with a bottle containing 70% isopropyl alcohol. The press the Prime Syringes button found under the Routines menu. Repeat this three(3) times. When the cycle is complete, replace the 70% isopropyl alcohol bottle with the Prime Bottle containing fresh DI water and repeat the Prime Syringes function at least four(4) times.

Trouble-Shooting Monobind Recommendations RESULT: Bad Duplication Bubbles in samples Dispensing error. RESULT: High Background Contamination Insufficient Wash Step RESULT: High Absorbance over entire plate Dispensing error. Wash Step Contamination RESULT: Assay Drift Reagents/samples are not at room temperature Application is not up-to-date Use a pin or needle to burst. Perform extra Prime Syringes Perform Alcohol Cleaning as defined in the monthly Check the physical condition of the syringes Switch to Mode 0 or Skip redundant wash probes NOT checked Perform extra Prime Syringes Perform Alcohol Cleaning as defined in the monthly Add CleanProbe with 0.1N HCl (2000µl) after the Enzyme/Tracer reagent dispense Perform washer vs. plate alignment Prime plate wash apparatus as described in the weekly Clean the wash head as described in the monthly Increase the number of wash cycles performed Perform extra Prime Syringes Perform Alcohol Cleaning as defined in the monthly Check the physical condition of the syringes Increase the number of wash cycles performed Switch to Mode 0 or Skip redundant wash probes NOT checked Perform extra Prime Syringes Perform Alcohol Cleaning as defined in the monthly Add CleanProbe with 0.1N HCl after Enzyme/Tracer reagent dispense Dispense samples/reagents only when ALL are at room temperature to prevent variation of temperature throughout the plate wells Contact technical support for most up-to-date software and application files