CLIMATE. Climate and temperature chambers.

Similar documents
ENVIRONMENTAL TESTING

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

RENTING OF CLIMATIC TEST SYSTEMS

EMC and Durability Lab, HCL Technologies Ltd., #73-74, South Phase, Ambattur Industrial Estate, Chennai

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Services Transport and PackagingTests Optimizationof Packagings Environmental Simulation Tests, Design Testing IP-Testing Packaging Validation and Pac

TESTS, MEASUREMENTS, ANALYSIS VIBRATION AND PRESSURE TESTS ENVIRONMENTAL AND CORROSION TESTS

Pneumatic Timer. TECHNICAL DATA Display digit roll s, s or s, depending on version Operating pressure 2...

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

TEMPERATURE - HUMIDITY VAISALA HMP155

Salt Spray Chamber HKT 1000

ISO INTERNATIONAL STANDARD. Road vehicles Environmental conditions and testing for electrical and electronic equipment Part 4: Climatic loads

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. AUTO TECHNOLOGY COMPANY Progress Drive Strongsville, OH Kevin Smith MECHANICAL

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

High Performance Thermal Circuit Breaker

Cyclic Corrosion Test CORR Series

Electrical Control Valves Series EX4, EX5, EX6, EX7 & EX8

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

3 Pin Schuko Converter Plug Technical Data & Fitting Instructions

Proportional pressure relief valve, pilot-operated, with anti-cavitation function, decreasing characteristic curve Type KBVS.2DB

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. AUTO TECHNOLOGY COMPANY Progress Drive Strongsville, OH Kevin Smith MECHANICAL

Industrial plug-in connectors HEAVYCON EVO. efficient at a twist of the wrist

Product Specification AMP Mini CT DC Drawer Connector, 1.5 mm Pitch Lead Free Version

Product Data Sheet ACi 4420 MLR

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Cetemet, your ally for your innovative ideas

POWER for AIRCRAFT GSE

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Model Travel CV-7A CVM-7A CV-7B CVM-7B CV-9A CVM-9A CV-9B CVM-9B CV-11A CVM-11A X-axis (left and right) mm Y-axis (back and

Zwick. Materials testing. Product Information LTM 5/10 electro-dynamic testing machine

Law 10/91 and DPR 412/93 require that the hot water temperature at the point of use is 48 C + 5 and require the insulation of all piping.

CHAPTER 4 : RESISTANCE TO PROGRESS OF A VEHICLE - MEASUREMENT METHOD ON THE ROAD - SIMULATION ON A CHASSIS DYNAMOMETER

Shenzhen Alpha Inverter Co., Ltd. ALPHA6300V Series Special AC Drive for Tension Control

Differential pressure sensor

LVElectric Motors Basics

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Draft ETSI EN V2.3.7 ( )

MERU Solar Off-Grid Inverters

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Protection and control VIP30, VIP35. Relays technical manual

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

ACCELERATED CORROSION TEST CHAMBERS

POWER kva

PRODUCT SPECIFICATION

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

Environmental Chamber

Product Data Sheet ACi 4420 HHR

DIESEL GENERATOR SET MTU 16V4000 DS2500

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

Cyclic Corrosion Chamber C.C.T AUTO Series

CERTIFICATE of QUALITY TEST

Dynamic climate chambers. MK MKF MKT MKFT series

Product Data Sheet DV5214 NU

NEMA Frame. W Premium Brake Motors NEMA. Foot Mounted 3PH, 60 Hz Aluminum Construction /5T 4.5

Technical data sheet. Technical data. Safety notes

DIESEL GENERATOR SET MTU 16V4000 DS2500

Series ISA. Air Catch Sensor. For Detection of Work Presence

POWER kva

EX4 / EX5 / EX6 / EX7 / EX8 Electrical Control Valves

ETSI EN V2.2.2 ( )

Final draft ETSI EN V2.2.1 ( )

EFFEKTA Power Supplies

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Power consumption Operation At rest Wire sizing. Auxiliary switch. EMC Low-voltage directive. Non-operating temperature range 40...

DIESEL GENERATOR SET MTU 20V4000 DS4000

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

500 / 630 / 720 / 760 / 800 / 850 / 900

Product Data Sheet 8314 HR-197

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT

MV2 SERIES: MV204 / MV205 MV214 / MV215 MV234 / MV235

Datasheet. Pitch Motor PMSM SP260B8

TURQUOISE STROKE SWITCHES

ETSI EN V2.1.2 ( )

Compressor Enclosures. Motorised Sliding Doors. Air Handling Units, Ventilation Systems & Ducting. IP56 Genset Enclosures for offshore application

Test Stand For Air Turbine Starters >TATS4<

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

Datasheet. Pitch Motor PMSM SP190C8

Batteries. Batteries. Accessories Guide Technical specifications are subject to change 2-27

MODEL FP-10. Read Instructions Carefully! CURTIS INSTRUMENTS, INC Kisco Ave. Mount Kisco, New York

TS Temperature Sensor and Transducers. Product Bulletin. Wide range of mounting types and signal outputs

Datasheet. Pitch Motor PMSM SP190F8

Differential Pressure Sensors

Company name: BKB Building Solutions Created by: Michael Chlopek Phone: Date: 14/03/2017

DIESEL GENERATOR SET MTU 12V4000 DS1750

Company name: GRUNDFOS (Singapore) Pte. Ltd. Created by: Angie Ang Phone: Date: 23/03/2017

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing. Non-operating temperature

Electrical Control Valves

product specification

UX series. Value model UX300. Offer max. value for small parts up to Ø400 x 352 mm / 100 kg. Motor FANUC = F SIEMENS = S HEIDENHAIN = X / Y / Z (kw) F

Actuator LA35. Data sheet LINAK.COM/TECHLINE

SCAL THERMAL SHOCK NERGY SAVING A STEP FURTHER ENVIRONMENTAL SIMULATION

Product Data Sheet 4184 NXHH

CM5-5 A-R-A-E-AVBE F-A-A-N

Transcription:

Climate and temperature chambers. The Environmental Competence Centre has a number of climate chambers at its disposal to carry out low and high temperature tests, as well as a number of combined climate chambers for low temperatures at high levels of relative humidity. Climate tests are normally carried out according to specific standards such as MIL-STD- 810, MIL-STD-202,IEC-60068, DNV GNV IEC-60529 etc. Temperature/Humidity Chamber Espec 125 Manufacturer: Espec, type PR-2KP -20 C up to +100 C Relative humidity: 20% up to 98% ±0.3 C Humidity accuracy: ±2.5% 1 C/min 3,5 C/min Dimensions of test area: 50 x 50 x 40 cm 2 x 5 cm Microprocessor.

Temperature/Humidity Chamber Espec 800 Manufacturer: Espec, type PL-4ST -40 C up to +100 C Relative humidity: 20% up to 98% ±0.3 C Humidity accuracy: ±2.5% 1 C/min 3,1 C/min Dimensions of test area: 100 x 100 x 80 cm 2 x 10 cm Microprocessor.

Temperature/Humidity Chamber Espec 1100 Manufacturer: Espec, type ARS-1100-75 C up to +180 C Relative humidity: 10% up to 98% ±0.3 C Humidity accuracy: ±2.5% 4.7 C/min 4.1 C/min Dimensions of test area: 110 x 100 x 100 cm 1 x 5 cm 1 x 10 cm Microprocessor.

Temperature/Humidity Chamber CTS TS-70/350 Manufacturer: CTS, type TS-70/ 350-70 C up to +180 C Relative humidity: 10% up to 98% ±0.5 C Humidity accuracy: ±3.0% 2.5 C/min 3.0 C/min Dimensions of test area: 65 x 72 x 75 cm 2 x 10 cm Microprocessor.

Temperature Chamber Espec ARG-680 Manufacturer: Espec, type ARG 680-75 C up to +180 C ±0.5 C 4.2 C/min 6.0 C/min Dimensions of test area: 85 x 100 x 80 cm 2 x 10 cm Microprocessor.

Temperature Chamber CTS TS -70/1250-15 Manufacturer: CTS, type -70/1250-15ARG 680-70 C up to +180 C ±0.3 C 15 C/min 15 C/min Dimensions of test area: 100 x 140 x 87 cm 2 x 10 cm 1 x 5 cm Microprocessor.

Temperature shock facility. Temperature shock tests are carried out amongst others on electronic components and composite products that can be subject to rapid changes in temperature. These tests also give more insight in properties and ageing of the devices examined. Temperature Chamber Weiss, TS130 Manufacturer: Dimensions of test area: Change time Hot/cold chamber: Weiss, type TS130-80 C up to +180 C ±1.0 C 30 C/min 30 C/min 45 x 50 x 60 cm Top, 1 x 5 cm Microprocessor. ±5 sec

Salt fog chamber. Corrosion tests are carried out on products, which will be subjected to sea and industrial climates. The climate chambers allow reproducible and quickened corrosion tests to be carried out according to international specifications. These tests determine corrosion resistance or can help with the application of corrosion protective measures. In the salt mist chamber, constant salt sprinkling tests, as well as test with sprinkle intervals (0-60 min) can be carried out. These tests are performed according to international specifications, like ASTM-117B, MIL-STD-810 and 202, IEC-68 and DIN-50021. In addition the condensation water test according to DIN-50017 can be carried out. Salt spray Chamber SC1000: Manufacturer : Dimensions test area: Weiss, type SC1000 156 x 59 x 70 cm Salt spray +50 C Condense + 45 C ±1 C 1 C/min 3.5 C/min microprocessor 2 x 1 cm

Temperature Vacuum Chamber. The temperature vacuum chamber is intended for carrying out tests on products in the field of extreme cold temperatures in combination with low pressure. Temperature vacuum tests are, amongst others, carried out to simulate air transport conditions for example in accordance with MIL 810 and IEC. Manufacturer : VACUUM SPECIALS Test area dimensions : 0,5 m x 0,5 m x 0,5 m (l x w x h) Maximum load : 20 kg Temperature range : -55 C up to +80 C Temperature accuracy : ± 1 C Min pressure : 10 mbar Max. cooling cap. : 80W Available: Mains power supply: 230 V (50 Hz) Feed through openings and windows

Large climate chamber 1. The large climate chamber is intended for carrying out tests on larger products and systems in the field of extreme temperatures and adjustable relative humidity. In addition solar radiation (1250W/m2) is possible. Climate tests are, amongst others, carried out under the authority of defence, car and aviation industry. Products tested are amongst others, radar systems, shelters, aggregates and vehicles. Manufacturer: Imtech Test area dimensions: 8 m x 6 m x 4.5 m (l x w x h), Entrance: 4.5 m x 4.5 m Entrance lock gate: 1m x 1,95 m Maximum floor load: 1000 kg/m2-60 C till +90 C Climate range: 0-60 C 10-100%RH Dew point range: 1 C till +60 C ±1 C Relative humidity accuracy: ±3% Air speed: 1 m/s Max cooling capacity at -40 C: 30 kw Max cooling capacity at +50 C: 60 kw

Available: Cooling-water: Compressed air: Vehicle exhaust gas removal: Mains power supply : Max mains supply power : 120l/min 300 m3/hr (fresh air) 380 V (50 Hz) 440 V (60 Hz) 416 V (400 Hz) 5 kva (50 Hz) 48 kva (60 Hz) 45 kva (400 Hz) Feed through openings and windows Advanced temperature and humidity control

Large climate chamber 2. Manufacturer: WEISS Test area dimensions: 3 m x 2,5 m x 3 m (l x w x h) Entrance: 1,6 m x 2,5 Entrance lock gate: 0,9m x 2 m Maximum floor load: 250 kg (each wheel) Maximum floor load: 3000 kg/m2 (equal loaded) -40 C till +100 C Dew point range: +5 C till +60 C ±1 C Relative humidity accuracy: ±5% Max cooling capacity: + 50 C < T < 0 C: Linear decreasing from 12 down to 10 kw + 0 C < T < - 30 C: Linear decreasing from 10 down to 2 kw - 30 C < T < -40 C: Linear decreasing from 2 down to 0 kw

Available: Cooling-water: Compressed air Exhaust of fumes Mains power supply : Max mains supply power : 120l/min 380 V (50 Hz) 440 V (60 Hz) 416 V (400 Hz) 5 kva (50 Hz) 48 kva (60 Hz) 45 kva (400 Hz) Feed through openings and windows Advanced temperature and humidity control

Degrees of protection provided by enclosures[ IP Code]. The extent of protection provided by an enclosure against access to hazardous parts, against. Ingress of solid foreign objects and/or against ingress of water and verified by standardized test methods. such as IEC 60529 IP 3X several probes available IPX5,12.5l/min, several water probes available

IPX6 100 l/min Drip-Box