Side Channel Pumps Self-priming, segmental type with verly low NPSH

Similar documents
SIHI prime - Side Channel Pumps Self-priming, segmental type with very low NPSH

Side Channel Pumps Self-priming, segmental type

SIHI prime - Side Channel Pumps Self-priming, segmental type

Product Reference Manual. FPD-xxxx. Experience In Motion

Side Channel Pumps CEH CEH 1202/ /7 TECHNICAL DATA. Temperature: max. 180 C Casing pressure: PN 40

Side channel pumps ADH/CDH AEH TECHNICAL DATA. Temperature: max. 120 C. PN 40 for AEH

Side Channel pumps Self-priming, segmental type

Side channel pump PN 40 SRZ. self-priming, according to DIN EN 734. Technical description

Liquid ring vacuum pumps with magnetic coupling

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

Norm-Centrifugal Pumps PN 10

High-pressure pumps Series HP49

Side channel pumps PN 16 SOH - SOHB - SOHM. Self-priming centrifugal pumps. Technical description

Side channel pumps PN 16 SOH - SOHB. Self-priming centrifugal pumps. Technical description

Liquid ring vacuum pumps

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

LPG Pump Catalogue. Auto Gas. Bottling. Transfer. Sterling Fluid Systems Group motralec

SIHI multi Type MSC. Modular multistage pumps. Description. Construction. Applications. Optional special designs. Materials.

Liquid ring compressors

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

Liquid ring vacuum pumps in compact design

Volute pumps for hot water up to 207 C

SIHI multi. Modular multistage pumps. Type MSL, MSM. Description. Construction. Applications. Technical Data. Options

Type ZEND. SIHI Model: ZEND / ZDND / ZHND Hot Water Transfer Pumps Product Reference Manual. Experience In Motion. FPD-xxxx

Volute pumps for heat carrier oils up to 350 C. SIHI SuperNova ZTND TECHNICAL DATA. Temperature: max. 350 C Casing pressure: PN 16

Volute pumps for hot water up to 230 C

Volute Casing Pump additional sizes to those of ISO 2858/EN 22858

Company name: BKB Building Solutions Created by: Michael Chlopek Phone: Date: 13/03/2017

Non-clogging Pump DBS TECHNICAL DATA. Output: up to 1200 m 3 /h. depending of the pump size and material execution

The Modular System SIHI ISOchem

XFLO XS SERIES. Single Stage Double Suction Split Casing Centrifugal Pump

Vertical multistage centrifugal pumps in ring-section design


Contents. Identification

SEMA Side channel pumps PN 25 (40) Glandless because of magnetic drive

Volute pumps for hot water

Non-clogging Pump DBS TECHNICAL DATA. Output: up to 1200 m 3 /h

PTB GLV. Vertical Centrifugal Pump

SIHI SuperNova. Volute casing pumps. Type ZLIC TECHNICAL DATA. 0B, 0C, 4B max. 120 C Casing pressure: PN 16 / PN 10 1)

High-pressure pumps Series HP45

Richter Sealless Chemical Magnetic Drive Pumps

General Catalog. A New Vision for Quality Pumps. General Catalog

RS Series Multi-stage, Ring Section Pump For Pressures to 1,500 PSI

Self-priming Centrifugal Pumps ACL

Single-stage centrifugal pumps to standards en 733 (nfe 44111) and iso 5199 Industry Agriculture - Heating

Multistage Pumps MP, MPA, MPB, MPV SIZES DN 40 - DN 125. Jansen Pompentechniek T: +31(0) E:

Volute Casing Centrifugal Pumps in In-line Design with Magnetic Drive. Series CNI-M

PA SERIES END SUCTION CENTRIFUGAL PUMP SINGLE STAGE BACK PULL-OUT DIN24255 THONG FATT JAYA MACHINERY HARDWARE SDN. BHD.

PN 16 Volute Centrifugal Pumps (depending on materials up to PN 25) according to EN 22858/ISO 2858 and EN ISO 5199

Volute Casing Centrifugal Pumps in High Temperature Design with Magnetic Drive. Series CNH-ML

Axial geteilte Spiral-gehӓusepumpen Axial split case pumps ASE ( ) PUMPS I MOTORS I SYSTEMS I SERVICES

Normpumpen nach DIN EN 733 einschl Standard horizontal pumps to DIN EN 733 NORMA J ( ) PUMPS I MOTORS I SYSTEMS I SERVICES

Chemical Motor Pump Unit BN

PN 16/PN 25 Volute Centrifugal-Pumps for Heat Transfer Media Thermal Oil up to 400 C Hot Water up to 207 C

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN. Heavy Duty, Multi-Stage, API 610 Process Pump

G&L Series MPVN. High Pressure Multi-Stage Pumps. Goulds Pumps. ITT Industries

CENTRIFUGAL PUMP TYPE SLM NV TO DIN EN AND DIN EN ISO SEALLESS WITH MAGNET DRIVE

Lowara. Centrifugal Electric Pumps Manufactured in AISI 316 Stainless Steel in Compliance with EN 733. SH Series. 60 Hz

Series PRODUCTS. self-priming Horizontal screw pump for non lubricating liquids. Water. Seawater. Heavy fuel oils. Bilge/Ballast pumps

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN. Heavy Duty, Multi-Stage, API 610 Process Pump

RS Multi-Stage, Ring Section Pumps

Data sheet. Page: 1 / 5 ETN GG A 11GA201502B. Operating data. Design. Requested developed head m. Efficiency 74.

NC State University Design and Construction Guidelines Division 23 Hydronic Pumps

Heat Transfer Fluid / Hot Water Pump HPK-L. Type Series Booklet

Volute Casing Centrifugal Pumps PN 16 for Heat Transfer Oils up to 350 C Series NTT Pump dimensions acc. to DIN EN 733 with additional sizes

CPS. Horizontal Split Case Centrifugal Pump

Volute Casing Centrifugal Pumps PN 16 for heat-transfer liquids Heat-transfer oil up to 350 C Hot water up to183 C

Etanorm SYT Type Series Booklet


General. Shaft Seal. Nozzle Orientations. Field of Application. Design. Drive. Bearings. Product Catalogue

PROCESS PUMPS MODEL V200 ANSI B73.2

Volute Casing Centrifugal Pumps according to EN 22858, ISO 2858 with Magnetic Drive. Series CNH-M

CombiChem. Centrifugal pumps according to ISO 5199 and ISO 2858 / EN (DIN 24256)

Supply plus delivery pressure must not exceed the admissible internal pump pressure.

TECHNICAL BROCHURE BMPVN MPVN HIGH PRESSURE MULTI-STAGE PUMPS

Pumps Motors ISO 9001 Company

NB /193 A-F2-A-BAQE

Combi Modular System. Standardised centrifugal pumps EN 733 EN ISO 5199 API 610

CENTRIFUGAL PUMP TYPE SLM NV TO DIN EN ISO 2858 AND DIN EN ISO 15783

Lowara. Centrifugal electric pumps made of AISI 316 stainless steel in compliance with EN 733. SH Series. 50 Hz

The e-nsc End Suction Pump Series

Dry installed end-suction pumps, LSN-series. according to ISO 2858 / ISO 5199

Volute Casing Pumps LSN. according to iso 2828 / iso Jansen Pompentechniek T: +31(0) E:

Elite. KSB Australia Pty Ltd. Centrifugal Pump

Technical data 50 & 60 Hz. Vertical centrifugal pumps Series: DPLHS

Multistage Pumps. Vogel Series P, PVa, MP 300

NK /310A2F1AE-SBAQE

Data sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design

MTB /183 A-F-A-BQQV 400D-2 11kW

VM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz

Boiler Feed Booster Pump YNK. Type Series Booklet

Data sheet. Customer item no.: Communication dated: Number: ES Doc. no.: Item no.: 100 Quantity: 1 Date: 19/03/2015 Page: 1 / 6

Grupa Powen-Wafapomp SA. Pumps for Power and Heat Supplying Industries catalogue

LPCD. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

NK40-160/172A1F2AE-SBAQE

GRUNDFOS DATA BOOKLET SP A, SP. Submersible pumps, motors and accessories 50 Hz

Submersible Long Shaft Pumps for the Chemical Industry Type NCT/NMT

NB /438 A-F1-A-GQQE

CR10-07 A-FJ-A-E-HQQE 3x400D 50 HZ

TOE-GN / GA / GI Series. Heat transfer pumps for heat transfer oils up to 350 C and hot water up to 160 C

Transcription:

Side Channel Pumps Self-priming, segmental type with verly low NPSH CEH Sizes 1201 6108, 1202/5 6108/5, 1202/7 6107/7 Technical data Capacity: Delivery head: Speed: max. 35 m³/h max. 354 m max. 1800 1/min Temperature: max. 120 C max. 180 C for high temperature design (higher temperatures upon request) Casing pressure: PN 40 Shaft sealing: Stuffing box or mechanical seal Flange connections: DIN 2501 / PN 40 Direction of rotation: anti-clockwise (when seen from the drive end) Application The SIHI CEH pump is a self-priming side channel pump capable of handling gas along with the medium and operates at a low noise level. The CEH pumps are used for problem-free pumping of clean liquids at unfavourable suction side conditions. They are also very suitable for positive suction heads below 0.5m. The different material possibilities with uniform dimensions and performance characteristics as well as the standard exchangeable components, make the CEH particularly recommendable for applications in the pharmaceutical, chemical or petrochemical market as well as in the plastic or oil industry. Because of its low NPSH and positive suction head the CEH is very suitable for the pumping of liquefied gasses and liquids under vapour pressure like condensate, refrigerant, boiler feed water or LPG. The pumps of the CEH /7 series have a retaining stage to avoid the dry running by controlling the liquid level in the pump. This design is especially developed for the handling of liquids under vapour pressure or when pumping from underground tanks. The series CEH /5 are used for bottom off-loading of liquids under vapour pressure. Design Pumps of the series CEH have a segmental type construction with open vane wheel impellers. The construction of the CEH pump is a so-called centrifugal combined system. This combination pump is suited with a centrifugal stage in serial connection before the side channel stages to obtain a more favourable NPSH. The program comprises 6 sizes each with 1-8 stages. The existing material design allows an optimum rating for the respectively desired performance range and the pumping medium. Pumps of the series CEH /7 are equal to the CEH series but equipped with a retaining stage. This program comprises 6 sizes with 2-7 stages. The series CEH /5 have also 6 sizes but with 2-8 stages. The applied hydraulic components are from our Modular Side Channel system (interchangeability of parts). Construction Casing pressure Maximum 40 bar from -40 C up to +120 C. Maximum 32 bar from +120 C up to +180 C. Pressure stages for temperature as per DIN EN 1333. Please observe Technical rules and safety regulations. Casing pressure = inlet pressure + delivery head at minimum pump capacity. Position of branches Axial suction branch, discharge branch points radially upwards. Flanges The flanges correspond to DIN EN 1092-2 / PN 40. Flange design as per DIN 2512 with groove or drilled according to ANSI 150 or 300 lbs is basically possible. Bearing One grease lubricated ball bearing according to DIN 625 and one liquid surrounded sleeve bearing (design A). The ball bearing is greased for life. Direction of rotation Anti-clockwise, when looking from the drive end. Shaft sealing The shaft can be sealed by a stuffing box or a mechanical seal conform DIN EN 12756. The shaft sealing is also available in a design suitable for heating or cooling of the stuffing box or the mechanical seal. Double mechanical seal (back-to-back as well as tandem) or a quench design with throttle bush are available upon request. The CEH can also be supplied with a magnetic coupling (for information see the separate catalogue). PUMP TECHNOLOGY CEH 133.51301.60.01 E 05/2015

Material design Cast iron and ductile iron Pos. Components Material design 0A 0B 0F 1A 1B 1F 1060 Suction casing EN-GJL-250 EN-GJS-400-18-LT 1070 Discharge casing EN-GJL-250 EN-GJS-400-18-LT 1080 1090 1140 1141 Intermediate piece EN-GJL-250 EN-GJS-400-18-LT 2100 Shaft X 20 Cr 13 2310 Impeller EN-GJL-250 2350 Vane wheel impeller CuZn40Al2 G-X 3 CrNiMoCuN 26 6 3 3 PAEK 3500 Bearing housing EN-GJL-250 CuZn40Al2 G-X 3 CrNiMoCuN 26 6 3 3 4410 Mechanical seal casing EN-GJL-250 EN-GJS-400-18-LT 4510 Stuffing box casing EN-GJL-250 EN-GJS-400-18-LT 0241 Bearing bush CY 10 C / Carbon Antimony* * Bearing bush in carbon antimony is used only in the high temperature design. This high temperature design is also provided with cup springs and a cooled stuffing box or cooled mechanical seal. PAEK Stainless steel Pos. Components Material design 1060 Suction casing G-X 6 CrNiMo 18 10 1070 Discharge casing G-X 6 CrNiMo 18 10 1080 1090 1140 1141 Intermediate piece G-X 6 CrNiMo 18 10 2100 Shaft X 5 CrNiMo 17 12 2 2310 Impeller G-X 3 CrNiMoNb 18 10 2350 Vane wheel impeller G-X 3 CrNiMoCuN 26 6 3 3 PAEK 3500 Bearing housing EN-GJL-250 coated 4410 Mechanical seal casing G-X 6 CrNiMo 18 10 0241 Bearing bush CY 10 C / Carbon Antimony * 4B * Bearing bush in carbon antimony is used only in the high temperature design. This high temperature design is also provided with cup springs and a cooled stuffing box or cooled mechanical seal. 4F Casing seal The casing seal can be sealed with a liquid compound or soft Teflon. Drive By lelectrica motor, type of construction IM B3. For LPG, EExe or Eex d(e) motors are available. 2

Sectional drawing and parts list CEH with stuffing box 0241 Bearing bush 1060 Suction casing 1070 Discharge casing 1080 Intermediate piece 1081 Retaining stage 1090 Suction intermediate piece 1140 Discharge intermediate piece 1141 Discharge intermediate piece 2100 Shaft 2310 Impeller 2350 Vane wheel impeller 3500 Bearing housing 4330 Mechanical seal 4410 Mechanical seal casing 4420 Cooling insert 4510 Stuffing box casing 4610 Stuffing box CEH with mechanical seal Unbalanced as well as balanced mechanical seals are available. Cooled stuffing box CEH /7 with retaining stage Cooled mechanical seal 3

Performance range General conditions Liquid: Water Density: 1 kg/dm³ Viscosity: 1 cst Temperature: 20 C Atmospheric pressure: 1013 mbar Characteristic tolerances Measuring standard According to ISO 5198. = Maximum for CEH /7 (with retaining stage) = Minimum for CEH /5 (e.g. LPG handling), CEH/7 The NPSH curve is suitable for liquids without gas. When using a liquid containing das (e.g. water 20 C) a safety margin of 1 m has to added. 4

CEH 1200 and CEH 1200/5 size kw kw 2) size plate B BDS 2) Pump set a b2 c d e1 e2 v f1 h3 m1 m2 w* w1 1201 0.37 71 P007 39 317 350 285 110 135 609 570 68 18 195 20 15-9 238 204 0.55 80 P008 45 297 400 265 120 140 643 640 0.55 0.55 80 47 P008 297 20 15 400 265 120 140 1202 0.75 0.75 80 68 76 20 44 229-9 272 238 677 640 1.1 1.0 90S P241 56 330 25 19 480 290 125 165 735 730 0.75 0.75 80 P210 52 300 420 260 115 711 650 1203 1.1 1.0 90S 68 76 22 58 263 25 19-9 165 306 272 P241 330 480 290 125 1.5 1.35 90L 62 769 730 1.1 1.0 90S 60 P241 68 76 330 480 290 125 1204 1.5 1.35 90L 24 64 297 25 19-9 165 340 306 803 730 2.2 2.0 100L P272 80 88 75 360 540 320 140 844 820 1.1 1.0 90S 66 68 76 837 1205 1.5 1.35 90L P272 26 70 331 360 25 19 540 320 140-9 165 374 340 820 2.2 2.0 100L 80 88 77 878 1.5 1.35 90L P272 68 76 72 360 19 540 320 140 165 871 820 1206 2.2 2.0 100L 28 84 365 25-9 408 374 P015 80 88 361 15 600 325 160 150 3.0 2.5 100L 85 912 1.5 1.35 90L 68 76 74 905 1207 2.2 2.0 100L P015 30 86 399 361 25 15 600 325 160-9 150 442 408 80 88 946 3.0 2.5 100L 87 1208 2.2 2.0 100L 88 P015 80 88 32 3.0 2.5 100L 89 433 361 25 15 600 325 160-9 150 476 442 980 * Dimensions depend upon the motor brand. Not for design CEH /5, 2) for EExe II T3 motors, 3) A safety margin of 1 m has to be added when using a liquid containing gas. The weight for stainless steel will be approximately 6% higher. 5

CEH 3100 and CEH 3100/5 size kw kw 2) size plate B BDS 2) Pump Set a b2 c d e1 e2 v f1 h3 m1 m2 w* w1 0.75 80 P008 60 297 20 15 400 265 120 152 691 640 3101 68 31 213-13 261 227 1.1 90S P241 67 330 25 19 480 290 125 177 749 730 1.1 1.0 90S 72 P241 68 78 330 480 290 125 789 730 3102 1.5 1.35 90L 34 74 253 25 19-13 177 301 267 2.2 2.0 100L P272 80 88 81 360 540 320 140 830 820 2.2 2.0 100L 89 3103 P272 80 88 38 293 360 25 19 540 320 140-13 177 341 307 870 820 3.0 2.5 100L 90 2.2 2.0 100L 93 P272 360 19 540 320 140 177 910 820 3104 3.0 2.5 100L 80 88 42 94 333 25-13 381 347 4.0 3.6 112M P015 117 361 15 600 325 160 162 931 3.0 2.5 100L 102 950 P015 80 88 600 160 162 3105 4.0 3.6 112M 45 120 373 361 25 15 325-13 421 387 971 5.5 5.0 132S 95 103 158 700 200 192 1047 1100 4.0 3.6 112M P015 80 88 123 600 160 162 1011 3106 5.5 5.0 132S 48 161 413 361 25 15 325-13 461 427 1087 95 103 700 200 192 1100 7.5 6.8 132M 171 1113 4.0 3.6 112M 80 88 143 172 1051 3107 5.5 5.0 132S 52 165 453 361 25 15 700 325 200-13 501 467 1127 1100 95 103 192 7.5 6.8 132M 205 1153 5.5 5.0 132S 198 1167 361 25 15 700 325 200 192 1100 3108 7.5 6.8 132M 95 103 55 208 493-13 541 507 1193 11.0 10.0 160M P436 253 540 30 24 840 490 215 240 1285 1270 * Dimensions depend upon the motor brand. Not for design CEH /5, 2) for EExe II T3 motors, 3) A safety margin of 1 m has to be added when using a liquid containing gas. The weight for stainless steel will be approximately 6% higher. 6

CEH 3600 and CEH 3600/5 size kw kw 2) size plate B BDS 2) Pump Set a b2 c d e1 e2 v f1 h3 m1 m2 w* w1 0.75 80 P008 55 297 20 15 400 265 120 152 691 640 3601 1.1 90S 68 31 67 213-13 261 227 P241 330 25 19 480 290 125 177 749 730 1.5 90L 74 1.5 1.35 90L P241 68 76 74 330 480 290 125 789 730 3602 34 253 25 19-13 177 301 267 2.2 2.0 100L P272 80 88 89 360 540 320 140 830 820 2.2 2.0 100L 89 870 3603 3.0 2.5 100L P272 80 88 38 101 293 360 25 19 540 320 140-13 177 341 307 820 4.0 3.6 112M 119 891 3.0 2.5 100L P272 105 360 19 540 320 140 177 910 820 80 88 3604 4.0 3.6 112M 42 117 333 25-13 162 381 347 931 P015 361 15 600 325 160 5.5 5.0 132S 95 103 152 182 1007 3.0 2.5 100L 102 950 P015 80 88 600 160 162 3605 4.0 3.6 112M 45 120 373 361 25 15 325-13 421 387 971 5.5 5.0 132S 95 103 171 700 200 192 1047 1100 4.0 3.6 112M P015 80 88 123 600 160 162 1011 3606 5.5 5.0 132S 48 161 413 361 25 15 325-13 461 427 1087 95 103 700 200 192 1100 7.5 6.8 132M 171 1113 5.5 5.0 132S 165 1127 3607 95 103 52 453 361 25 15 700 325 200-13 192 501 467 1100 7.5 6.8 132M 168 1153 5.5 5.0 132S 161 1167 361 25 15 700 325 200 192 1100 3608 7.5 6.8 132M 95 103 55 171 493-13 541 507 1193 11.0 10.0 160M P436 254 540 30 24 840 490 215 240 1285 1270 * Dimensions depend upon the motor brand. Not for design CEH /5, 2) for EExe II T3 motors, 3) A safety margin of 1 m has to be added when using a liquid containing gas. The weight for stainless steel will be approximately 6% higher. 7

CEH 4100 and CEH 4100/5 size kw kw 2) size plate B BDS 2) Pump Set a b2 c d e1 e2 v f1 h3 m1 m2 w* w1 4101 1.5 90L P241 68 81 330 480 290 125 798 730 41 268 25 19-23 197 294 260 2.2 100L P272 80 95 360 540 320 140 839 820 2.2 2.0 100L 98 894 4102 3.0 2.5 100L P272 80 88 47 110 323 360 25 19 540 320 140-23 197 349 315 820 4.0 3.6 112M 128 915 4103 4.0 3.6 112M P015 80 128 600 160 182 970 88 53 378 361 25 15 325-23 404 370 5.5 5.0 132S 95 179 700 200 192 1046 1100 4104 5.5 5.0 132S 172 1101 95 103 59 433 361 25 15 700 325 200-23 192 459 425 1100 7.5 6.8 132M 182 1127 5.5 5.0 132S 178 1156 361 25 15 700 325 192 1100 4105 7.5 6.8 132M 95 103 65 181 488 200-23 514 480 1182 11.0 10.0 160M P385 264 490 30 24 740 440 240 1274 1140 4106 7.5 6.8 132M P385 196 490 740 440 200 212 1237 1140 95 103 70 543 30 24-23 569 535 11.0 10.0 160M P436 269 540 840 490 215 240 1329 1270 7.5 6.8 132M 202 212 1292 P436 95 103 540 30 24 840 490 215 1270 4107 11.0 10.0 160M 76 275 598-23 240 624 590 1384 15.0 13.5 160L P487 110 118 349 610 35 28 940 550 240 260 1446 1420 4108 11.0 10.0 160M 95 103 281 1439 P487 82 653 610 35 28 940 550 240-23 260 679 645 1420 15.0 13.5 160L 110 118 355 1501 * Dimensions depend upon the motor brand. Not for design CEH /5, 2) for EExe II T3 motors, 3) A safety margin of 1 m has to be added when using a liquid containing gas. The weight for stainless steel will be approximately 6% higher. 8

CEH 5100 and CEH 5100/5 size kw kw 2) size plate B BDS 2) Pump Set a b2 c d e1 e2 v f1 h3 m1 m2 w* w1 5101 3.0 100L P272 123 360 19 540 320 140 225 918 820 80 4.0 112M 60 162 305 25-28 353 315 939 P015 361 15 600 325 160 210 5.5 132S 95 170 1015 5.5 5.0 132S 183 1090 361 25 15 700 325 220 1100 5102 7.5 6.8 132M 95 103 70 193 380 200-28 428 390 1116 11.0 10.0 160M P385 269 490 30 24 740 440 240 1208 1140 5103 7.5 6.8 132M 196 361 25 15 700 325 220 1191 1100 95 103 200 11.0 10.0 160M P385 80 279 455 490 740 440-28 503 465 1283 1140 30 24 240 15.0 13.5 160L P436 110 118 353 540 840 490 215 1345 1270 5104 11.0 10.0 160M 95 103 289 1358 P436 90 530 540 30 24 840 490 215-28 240 578 540 1270 15.0 13.5 160L 110 118 363 1420 5105 15.0 13.5 160L 374 260 1495 110 118 18.5 15.0 180M P487 101 395 605 610 35 28 940 550 240-28 653 615 1420 280 1557 22.0 17.5 180L 125 135 415 5106 15.0 13.5 160L P487 384 610 940 550 240 260 1570 1420 110 118 18.5 15.0 180M 423 111 680 35 28-28 280 728 690 1632 22.0 17.0 180L P538 425 660 1060 600 280 1620 125 135 30.0 24.0 200L 506 300 1690 5107 18.5 15.0 180M 110 118 415 280 1707 22.0 17.5 180L P538 121 435 755 660 35 28 1060 600 280-28 803 765 1620 125 135 30.0 24.0 200L 516 300 1765 5108 22.0 17.5 180L P539 446 660 35 125 135 132 830 28 1060 600 280 280 1782 1620-28 878 840 30.0 24.0 200L S () 527 540 40 1200 490 300 300 1840 1800 * Dimensions depend upon the motor brand. Not for design CEH /5, 2) for EExe II T3 motors, 3) A safety margin of 1 m has to be added when using a liquid containing gas. The weight for stainless steel will be approximately 6% higher. 9

CEH 6100 and CEH 6100/5 size kw kw 2) size plate B BDS 2) Pump Set a b2 c d e1 e2 v f1 h3 m1 m2 w* w1 6101 5.5 132S 206 1073 95 80 338 361 25 15 700 325 200-35 240 391 353 1100 7.5 132M 203 1099 6102 11.0 10.0 160M P385 95 103 291 490 740 440 200 1281 1140 92 428 30 24-35 260 481 443 15.0 13.5 160L P436 110 118 365 540 840 490 215 1343 1270 6103 18.5 15.0 180M 110 118 404 P487 105 22.0 17.5 180L 125 135 419 518 610 35 28 940 550 240-35 280 571 533 1495 1420 6104 22.0 17.5 180L P487 431 610 940 550 240 280 1585 1420 125 135 117 608 35 28-35 661 623 30.0 24.0 200L P538 512 660 1060 600 280 300 1643 1620 6105 30.0 24.0 200L 125 135 525 300 1733 P538 130 698 660 35 28 1060 600 280-35 751 713 1620 37.0 30.0 225S 140 152 594 325 1798 30.0 24.0 200L P538 125 135 537 660 35 1060 600 280 300 1823 1620 6106 37.0 30.0 225S 142 606 788 28-35 841 803 S609 140 152 730 40 1200 670 310 325 45.0 36.0 225M 670 1888 1820 30.0 24.0 200L S389 125 135 550 540 490 300 300 1913 1800 6107 37.0 30.0 225S 155 619 878 40 28 1200-35 931 893 S609 140 152 730 670 310 325 45.0 36.0 225M 683 1978 1820 37.0 30.0 225S 532 2003 14211 140 152 350 345 2000 6108 45.0 36.0 225M 167 630 968 740 40 28 1300 690-35 1021 983 2080 55.0 44.0 250M 14212 160-701 400 370 2125 2100 * Dimensions depend upon the motor brand. Not for design CEH /5, 2) for EExe II T3 motors, 3) A safety margin of 1 m has to be added when using a liquid containing gas. The weight for stainless steel will be approximately 6% higher. 10

CEH 1200/7 (with retaining stage) size kw size plate BDS Pump Set a b2 c d e1 e2 v f1 h3 m1 m2 w* w1 1202/7 0.55 Größe 80 52 P210 76 22 0.75 80 53 263 300 25 19 420 260 115-9 165 306 272 709 650 1203/7 0.75 80 54 743 P241 76 24 297 330 25 19 480 290 125-9 165 340 306 1.1 90S 64 796 730 1204/7 1.1 90S 70 P272 76 26 1.5 90L 71 331 360 25 19 540 320 140-9 165 374 340 930 820 1205/7 1.5 90L P272 76 73 360 19 540 320 140 165 864 28 365 25-9 408 374 2.0 100L P015 88 84 361 15 600 325 160 150 922 820 1206/7 1.5 90L 76 69 898 P015 30 399 361 25 15 600 325 160-9 150 442 408 2.0 100L 88 86 956 1207/7 1.5 90L 76 71 932 P015 32 433 361 25 15 600 325 160-9 150 476 442 2.0 100L 88 91 990 * Dimensions depend upon the motor brand A safety margin of 1 m has to be added when using a liquid containing gas. 11

CEH 3100/7 (with retaining stage) size kw size plate BDS Pump Set a b2 c d e1 e2 v f1 h3 m1 m2 w* w1 3102/7 1.5 Größe 90L 76 87 822 P272 38 293 360 25 19 540 320 140-13 177 341 307 2.0 100L 88 100 880 820 3103/7 2.0 100L 104 P272 88 42 2.5 100L 106 333 360 25 19 540 320 140-13 177 381 347 820 3104/7 2.5 100L 101 960 P015 88 45 373 361 25 15 600 325 160-13 162 421 387 3.6 112M 107 966 3105/7 2.5 100L 107 P015 88 48 413 361 25 15 600 325 160-13 162 461 427 1000 3.6 112M 110 1006 3106/7 3.6 112M 88 117 172 52 453 361 25 15 700 325 200-13 501 467 1046 1100 5.0 132S 103 151 192 1142 3107/7 3.6 112M 88 120 172 55 493 361 25 15 700 325 200-13 541 507 1086 1100 5.0 132S 103 154 192 1182 * Dimensions depend upon the motor brand A safety margin of 1 m has to be added when using a liquid containing gas. 12

CEH 3600/7 (with retaining stage) size kw size plate BDS Pump Set a b2 c d e1 e2 v f1 h3 m1 m2 w* w1 3602/7 1.5 Größe 90L 76 87 822 P272 38 293 360 25 19 540 320 140-13 177 341 307 2.0 100L 88 100 880 820 3603/7 2.0 100L 104 P272 88 42 2.5 100L 106 333 360 25 19 540 320 140-13 177 381 347 820 3604/7 2.5 100L 101 960 P015 88 45 373 361 25 15 600 325 160-13 162 421 387 3.6 112M 107 966 3605/7 2.5 100L 107 P015 88 48 413 361 25 15 600 325 160-13 162 461 427 1000 3.6 112M 110 1006 3606/7 3.6 112M 88 117 172 52 453 361 25 15 700 325 200-13 501 467 1046 1100 5.0 132S 103 151 192 1142 3607/7 3.6 112M 88 120 172 55 493 361 25 15 700 325 200-13 541 507 1086 1100 5.0 132S 103 154 192 1182 * Dimensions depend upon the motor brand A safety margin of 1 m has to be added when using a liquid containing gas. 13

CEH 4100/7 (with retaining stage) size kw size plate BDS Pump Set a b2 c d e1 e2 v f1 h3 m1 m2 w* w1 4102/7 2.5 Größe 100L 112 959 P015 88 53 378 361 25 15 600 325 160-23 182 404 370 3.6 112M 115 965 4103/7 3.6 112M P015 88 121 600 160 182 1020 59 433 361 25 15 325-23 459 425 5.0 132S 103 158 700 200 192 1116 1100 4104/7 3.6 112M 88 130 65 488 361 25 15 700 325 200-23 192 514 480 1075 1100 5.0 132S 103 164 1171 4105/7 5.0 132S 172 P385 103 70 543 490 30 24 740 440 200-23 212 569 535 1226 1140 6.8 132M 232 1237 4106/7 6.8 132M 248 212 P436 103 76 598 540 30 24 840 490 215-23 624 590 1292 1270 10.0 160M 278 240 1379 4107/7 6.8 132M P436 230 540 30 24 840 490 215 212 1347 1270 103 82 653-23 679 645 10.0 160M P487 296 610 35 28 940 550 240 260 1434 1420 * Dimensions depend upon the motor brand A safety margin of 1 m has to be added when using a liquid containing gas. 14

CEH 5100/7 (with retaining stage) size kw size plate BDS Pump Set a b2 c d e1 e2 v f1 h3 m1 m2 w* w1 5102/7 5.0 Größe 132S 180 103 80 455 361 25 15 700 325 200-28 220 503 465 1180 1100 6.8 132M 232 1191 5103/7 6.8 132M P385 252 490 740 440 200 1266 1140 103 90 530 30 24-28 240 578 540 10.0 160M P436 292 540 840 490 215 1353 1270 5104/7 10.0 160M 325 P487 103 101 605 610 35 28 940 550 240-28 260 653 615 1428 1420 13.5 160L 347 1472 5105/7 10.0 160M 103 335 1503 P487 610 940 550 240 260 1420 13.5 160L 111 357 680 35 28-28 728 690 1547 118 15.0 180M P538 395 660 1060 600 280 280 1640 1620 5106/7 13.5 160L 408 260 P538 118 121 755 660 35 28 1060 600 280-28 803 765 1622 1620 15.0 180M 429 280 1715 5107/7 15.0 180M 440 P538 118 132 17.5 180L 463 830 660 35 28 1060 600 280-28 280 878 840 1790 1620 * Dimensions depend upon the motor brand A safety margin of 1 m has to be added when using a liquid containing gas. 15

CEH 6100/7 (with retaining stage) size kw size plate BDS Pump Set a b2 c d e1 e2 v f1 h3 m1 m2 w* w1 6102/7 6.8 Größe 132M P385 267 490 740 440 200 1279 1140 103 105 518 30 24-35 260 571 533 10.0 160M P436 307 540 840 490 215 1366 1270 10.0 160M 103 331 1456 6103/7 13.5 160L P487 117 363 608 610 35 28 940 550 240-35 280 661 623 1500 1420 118 15.0 180M 384 1593 15.0 180M 439 118 6104/7 17.5 180L P538 130 461 698 660 35 28 1060 600 280-35 280 751 713 1683 1620 24.0 200L 135 540 300 1738 15.0 180M 450 118 6105/7 17.5 180L P538 142 473 788 660 35 28 1060 600 280-35 280 841 803 1773 1620 24.0 200L 135 485 300 1828 17.5 180L 118 391 S389 540 6106/7 155 878 40 28 1200 490 300 280 1863 1800 24.0 200L 135 470-35 300 931 893 1918 30.0 225S S609 152 620 730 670 310 325 2018 1820 24.0 200L S389 135 482 540 1200 490 300 300 2008 1800 6107/7 30.0 225S 167 532 968 40 28-35 1021 983 2003 14211 152 740 1300 609 350 345 2000 36.0 225M 630 2080 * Dimensions depend upon the motor brand A safety margin of 1 m has to be added when using a liquid containing gas. 16

Sterling SIHI GmbH Lindenstr. 170, 25524 Itzehoe, Germany Telephone +49 (0) 4821 771-01 Telefax +49 (0) 4821 771-274 www.sihi.com 17