n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

Similar documents
n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

Product Specifications

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA

Series 120/120VAC Universal Tower/Rack Mount

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

On-line, Single Phase, Double Conversion UPS

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

WHY STACO ENERGY PRODUCTS?

MGE TM Galaxy TM 7000

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

G V Series UNINTERRUPTIBLE POWER SYSTEMS. Phone: Fax: Web:

PowerWave 33 Efficient power protection for today s IT and process-related work environments

MGE TM Galaxy TM 7000 GFC

TLE Series UPS 400/500 kw With eboost Technology

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

TECHNICAL DATA SHEET KVA UPS Systemss

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Technical Data Sheets

TLE Series UPS 160/200/225/250 kw with eboost Technology

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

MKN-DSP SERIES - THREE PHASE

TLE Series UPS 750/1000 kw With eboost Technology

D Series: UPS UPTO - 300KVA - Three / Three Phase

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution

G9000 UNINTERRUPTIBLE POWER SYSTEMS

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

EFFEKTA Power Supplies

GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE POWER SUPPLY

PowerValue 11/31 T kva

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

Green Power 2.0 MASTERYS GP

G9000 UNINTERRUPTIBLE POWER SYSTEMS

Three-phase UPS system DPA UPScale ST kw The modular UPS designed for lowand medium-power applications

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

Technical Data Sheets

Technical Data Sheets

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

POWER kva

LIEBERT APM 3-PHASE UPS: 15-90KVA/KW, 60HZ, VAC, SINGLE & DUAL INPUT - SITE PLANNING DATA

Industrial PFC UPS System

Technical Data Sheets

TOSHIBA /20/25/30/50kVA Internal Battery GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE POWER SUPPLY

POWER kva

Illuminator Series CR NEMA 3R

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE POWER SUPPLY

MASTERYS IP+ 10 to 80 kva

Master Plus kva

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Galaxy VM. From 160 kva to 1000 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity. schneider-electric.

Features and Benefits

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

1.1 GENERAL CHARACTERISTICS

TOSHIBA G , 750kVA

Technical Data Sheets

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

Technical Data Sheets

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

Symmetra PX 250/500. Scalable from 100 kva kw to 500 kw, parallel capable up to 2,000 kw

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

3 Uninterruptible Power Systems

Three-phase UPS system. DPA UPScale ST kw Best-in-class modular UPS for maximum availability

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 10KW 33KW Systems

Galaxy VM. From 160 kva to 1000 kva Three-phase power protection. apc.com/products

Liebert. FP 50Z kva

60 to 160 kva.

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 40KW 55KW Systems

Symmetra PX. Industry-leading efficiency, availability, and performance for small, medium, and large data centers and mission critical environments

3 Uninterruptible Power Systems

EATON 9315 UPS 200 TO 300 KVA Specifications

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Standalone three-phase UPS system. PowerWave kw Unmatched power performance

Technical Data Sheets

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

Galaxy VM. From 160 kva to 1000 kva, 160 kva or 200 kva modular approach. Three-phase power protection

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

Liebert NX TM. 250kVA kVA Transformer-free. High Efficiency, Scalable On-line UPS

Est FlexiPower Mini UPS FPX Mini kVA

ConceptpowerTM Modular kVA

GUIDE SPECIFICATIONS 15-45kVA and 15-90kVA Scalable Three-Phase Uninterruptible Power System 1.0 GENERAL

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

SITE PLANNING DATA LIEBERT EXM 3-PHASE UPS: KVA/KW, 60HZ, VAC, SINGLE INPUT

Options & service. Additional 9355 options. Proven warranty and support services. Extensive service options for enhanced reliability.

Three Phase UPS Systems Range: 10 to 500kVA

Features and Benefits

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

Transcription:

80-125 kva/kw E Three-Phase Double-Conversion On-Line Full Four Year Warranty www.stacoenergy.com Up to 99% Efficient n Lower energy costs and carbon footprint Compact & Reliable n Requires either front, top or bottom access, so it can be placed against a wall to minimize footprint n Cooler operation extends internal component life AC Input Performance n High input power factor of 0.99 n Low input current distortion of 3% n Power walk-in function that ensures progressive rectifier start-up 3 Level IGBT Switching and DPS Processing n Reduces the impact of the on the local supply n Simplifies installation where there is limited power capacity in the form of available electrical supply rating or generator size Single or Dual Input Configuration n Main power and secondary emergency standby power increase resilience of single or parallel system configuration High Performance Input Filtering n Protects upstream power supply sources from harmonics and reactive power generated by the loads Menu Select Display n User friendly display is easy to see and intuitive to use Parallel up to 8 Units n Provides redundancy for mission critical applications with no additional hardware Seismic Certified n Equipped with proper anchorage for seismic applications; Seismic certificates available upon request Worldwide Service Program n Factory trained service personnel maximize equipment life n Full start-up service & preventive maintenance lowers cost of ownership Your Tailored Power Solutions Provider TM

FirstLine PE In the event of an AC power failure, the FirstLine PE will automatically transfer to battery power and continue to provide power without any interruption for the full amount of time you select. When power returns, the FirstLine PE will automatically recharge the batteries for the next unexpected power outage or disturbance. AC Input Performance FirstLine PE is a further evolution of the FirstLine series with the added advantages offered by a 3 level switching rectifier and inverter. This feature reduces the impact of the on the local supply and simplifies installation where there is limited power capacity in the form of available electrical supply rating or generator size. The FirstLine PE provides: n Low input current distortion < = 3% n High input power factor 0.99 n Power walk-in function that ensures progressive rectifier start up n Delayed start up phased with the return of mains power supply, when several are connected in the system. n High energy efficiency, 96% at full load. FirstLine PE also performs the role of a high performance filter, protecting its upstream power supply sources from any harmonics and reactive power generated by the loads powered. Flexibility FirstLine PE can be supplied from two separate power sources (main power and a second emergency standby source) which helps increase the resilience of parallel system configurations. FirstLine PE Main Characteristics n Efficieny 96% at full load and up to 99% in ECO / hot standby Mode n Reduced weight n Battery Temp Sensor Module monitors the battery internal cabinet environmental conditions of one (1) Battery Cabinet connected to the and displayed on the front mimic panel. The entire FirstLine PE range is suitable for a wide range of applications thanks to the flexibility of configurations, accessories, options, and choice of performance levels. The is compatible with capacitive loads, such as blade servers, without any reduction in active power, ranging from 0.9 lead to 0.8 lag and up to 0.8 capacitive power with a low derating equal to 15% of the active power (kw). Efficient and reliable power supply for mission critical applications is guaranteed by operating in redundancy and power parallel mode with up to 8 units (N+1), and by the Dual Bus System and Dynamic Dual Bus system configurations. Other Options Remote Status Panel provides fault indication for System Normal, Alarm, Shutdown Imminent, Mains Failure, Load on Service, and Inverter Fault. Top or Side Cable Entry A side-car cabinet expansion is offered to accommodate top or side incoming cable entry. External Maintenance Bypass, 3 Breaker with Electronic Interlocks Make-Before-Break, Line Up and Match wrap-around MBP for total isolation during maintenance or removal of the. Power Distribution Unit (PDU) PDU provides 208/120 output distribution capabilities to peripheral devices. Up to (4) 42 Pole Panelboards or Sub-Feed Circuit Breakers available. Battery Monitoring System (BMS) The FirstLine BMS systems provide monitoring and record battery cycle data of each battery string or jar. Factory installed for easy commissioning. Harsh Environment Enclosure and accessories mounted and pre-wired internal, with AC cooling inside any NEMA (12, 3R, 4X) type enclosure. Seismic Withstand Certification Site specific seismic certification and documentation. All units come standard with bolt down capability. Start-Up Service, Preventative Maintenance Programs A wide range of service programs are available to suit all user requirements. Consult factory. www.stacoenergy.com

Battery Care System FirstLine PE uses the Battery Care System which optimizes battery performance while extending battery life. Front Panel Display Color touch screen display with integrated 4 channel oscilloscope for troubleshooting input, output, and DC signal without any use of special software or encrypted tools. Allows analysis of 3 phase voltage, current, frequency, DC link voltage and DC current within the chassis. FirstLine PE shown with optional side car Detection of the input failure from the generator. Input voltage and frequency shown for easy understanding of why the accessed the battery backup circuit. Applications n Data Centers n Computer Networks n Industrial Process Manufacturing n Hospitals/Medical n Education/Research n Laboratories, Bio-Tech n Pharmaceuticals/Chemical n Critical Power Management Requirements n Any areas needing computer grade power and a high level of available power Four Year Warranty Electronics: A full Four Year On-site Warranty (Continental U.S.) Battery: Three (3) Year Full, Limited Warranty, on the Battery System ensures that your batteries are protected from system failure now and in the future. (Warranty provided by battery manufacturer.) Extended warranties, customized service plans and preventative maintenance are also available. Please refer to our warranty statement for complete details. Staco Energy Products Co.

Electrical Specifications Electrical Data Power (kva / kw) 80 / 80 100 / 100 125 / 125 INPUT Nominal voltage 480VAC 3 phase, 3-Wire + Grd. Nominal voltage range -30%, +15% Input frequency range From 45 to 65Hz Nominal input current 100 125 156 Maximum input current 112 145 181 Power factor at nominal voltage (480 V) and battery charged from 25% to 100% of the load > 0.99 Reflected Current Harmonic distortion (THDi) at 100% load 3% Rectifier Walk-in from 0 to 125 seconds (configurable) Rectifier Walk-in Delay from 0 to 600 seconds (configurable) D.C. INTERMEDIATE CIRCUIT Number of cells 240 INVERTER Static variation ± 1% Dynamic variation ± 5% Crest Factor 3:1 Voltage distortion with linear load 1% Voltage distortion with non-linear load < 3% Frequency stability with synchronized inverter to the by-pass network. ± 2% ( ± 1% to ± 6% from control panel) Frequency stability with not synchronized inverter to the by-pass line ± 0.1Hz Speed of frequency variation 1Hz/sec (parallel units can be calibrated from 0.1 to 1Hz/s) Phase voltage asymmetry with balanced and unbalanced load. 1% Phase displacement of the voltages with balanced and unbalanced loads. 120 ± 1 el Overload in referred to the nominal power 110% for 60 minutes, 125% for 10 minutes, 150% for 1 minute Inverter efficiency 96% BY-PASS Nominal voltage 480VAC 3-phase (without neutral) Nominal voltage tolerance ± 10% (up to ± 20% Programmable) Nominal frequency 50/60 Hz Frequency tolerance ± 5% Nominal (up to ± 10% Programmable) SYSTEM AC/AC efficiency at full load 96% Efficiency with in STAND-BY mode up to 99 % Full Load Heat Rejection BTU/hr 10,350 13,058 17,055 MECHANICAL Height x Width x Depth inches (mm) 70.98 x 27.56 x 32.24 [1803 x 700 x 819] with side car 70.98 x 43.58 x 32.24 [1803 x 1107 x 819] Weight lbs. / [kg] 991 / [450] with side car Minimum 1141 / [518] Maximum 1281 / [581] Freestanding NEMA 1 enclosure, powder coat painted black color with textured finish, bottom access for conduit entries ENVIRONMENTAL Ambient temperature -5 C to 40 C Storage temperature -25 C to 55 C Relative Humidity 0 ~ 95% non-condensing Altitude < 2000 meters Derate load capability above 1000 meters 1% per 100 meters Audible Noise 69 dba COMMUNICATIONS SNMP/WEB (Standard) SNMP Card with NetAgent Software Modbus (Standard) Monitoring via RS-485/RTU Protocol/Read Holding BACnet (Optional) TCIP & RS485 SNMP/WEB WiFi or Cellular (Optional) SNMP Card with NetAgent Software Modbus WiFi or Cellular (Optional) Monitoring Protocol/Read Holding BACnet WiFi or Cellular (Optional) TCIP FirstLine PE www.stacoenergy.com

FLE-XXX-01 Standard - Single Input Unit FLE-XXX-01 Standard - Dual Input Unit FLE-XXX-03 or Higher - Single Input with Optional Side Car 1 Touch Screen Color Display 2 EPO Switch 3 Dual Action & Redundant ON & OFF Switch a Secured Against Incidental Touch 4 Key Access Door Handle 5 Filtered Ventilation 6 Optional Side Car Shown with door open. Door is lockable. a Empty for Top Cable Entry Only b With 3 Breaker MBP (UL1778) c With 3 Breaker MBP & LB Breaker (UL1778) d With b. or c. plus SKRU 7 MBP Breaker with HASP 8 BIB Bypass Input Breaker 9 MIB Maintenance Isolation Breaker 10 Load Bank Breaker FirstLine PE 80 125 kva / kw Part Numbers FLE-XXX-03 or Higher - Dual Input with Side Car Model FLE-080-01 FLE-100-01 FLE-125-01 kva / kw 80kVA/80kW 100kVA/100kW 125kVA/125kW Standards l Underwriters Laboratories, Listed to UL1778 (Designed to 60950); c-ul to CSA C22.2 l NEMA PE-1 l ASME l ASA-C-39.1-1984 l FCC PT 15, Subpart J, Class B l National Electrical Code l IEEE 587 ANSI C 62.41-1980 l ISO 9001 l IBC (International Building Code) Ratings A-F, Site Specific FirstLine PE Up to Eight Units in Parallel Staco Energy Products Co.

Service Options Staco Service offers a wide range of planned maintenance and extended service options to maximize equipment life and reliability of your FirstLine. Through an extensive network of factory trained professionals you receive: Annual Service Plan 24/7 Emergency Service Preventive Maintenance Programs tailored to meet your needs About Staco Energy Products Since 1937, customers worldwide have been relying on Staco Energy Products Company to deliver voltage control and power quality solutions tailored to their needs. As a leading power quality resource, we offer our customers world-class support; from our thorough applications assessment, to our ability to design and deliver a solution that is tailored to the specific needs of our customers; through delivery and commissioning. Our professional, factory trained service team is in place to ensure that our customers revenues are protected, and their investment provides them with many years of trouble free operation. In addition to the FirstLine products we offer a wide array of power quality products, including: Uninterruptible Power Supplies Power Conditioners Voltage Regulators Power Factor Correction and Harmonic Mitigation Active Harmonic Filters Variable Transformers Custom Engineered Test Sets Staco develops total power solutions for OEM and end user applications. Represented locally by: Contact Us: US Toll Free: 866-261-1191 Phone: 937-253-1191 E-mail: sales@stacoenergy.com Your Tailored Power Solutions Provider TM 2017, Staco Energy Products Co. FL-PE_bro-170623 For more information about the FirstLine PE www.stacoenergy.com/