10W LED Die Cast Small Rectangle Bulkhead Light

Similar documents
25W LED Cross Bezel Bulkhead Light

2x 10W LED Slimline Floodlight Twin Flood

18W Round LED Slimline Emergency Light

24 Hour Immersion Heater Time Controller

3000W Dusk to Dawn Light Controller

Adjustable Pneumatic Time Delay Switch

24 Hour Mechanical Time Switch with Voltage Free Contacts

Wireless Digital Room Thermostat with Night Set-Back

I n s t a llat ion & O p e r atin g In s truc t ions

18W Low Energy. instructions. Instructions

Model: ECO1FL Model: ECO2FL Model: ECO3FL. Installation & Operating Instructions ECO CFL Flood Light Uncontrolled

Dedicated PIR Light Controller c/w RF remote control for LEDPRO Floodlights

ECO CFL. with Photocell. Instructions. Model: ECO2DD Model: ECO3DD

Installation & Operating Instructions

Round Pattern 24 Hour Electromechanical Time Controllers with Half Day & Day Omit

INSTALLATION & OPERATING INSTRUCTIONS

INSTALLATION & MAINTENANCE MANUAL HBL

LED Area Light. This is the fixture of choice for all of our dealerships. Contact Us:

LED Area Light. scratch that. This is the fixture of choice for all of our dealerships. Contact Us:

ASSEMBLY & FITTING INSTRUCTIONS P-LUX3 LED TRI-SENSOR LANTERN

LED AC DRIVERLESS FLOODLIGHTS WITH PIR FOR MODEL: FLAC10BPIR, FLAC20BPIR, FLAC30BPIR & FLAC50BPIR

Doc Ref: WD027/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

MAINTAINED LED CIRCULAR EMERGENCY CEILING LIGHT

NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT

MAINTAINED LED DOUBLE SIDED SUSPENDED CEILING MOUNTED EMERGENCY LIGHT

Technical Data. Dimmer Switches - Push Type 881P/885P 882P 883P 884P

Specification Sheet for 2D LED Light

INFRESCO-S-4kW X20034 Issue: 7

Model: CF16MS / CF16CR / CF16WH CF28MS / CF28CR / CF28WH

icebreaker icebreaker A C G GE Lighting 2D lamps are fitted as standard. I44

MAINTAINED LED EMERGENCY CEILING MOUNT SPOTLIGHT

The following lighting types are NOT compatible with the TT- 402Wireless Inline Dimmers:

Technical Data. 45 Amp Switches. Brief product description: Features:

MANUFACTURED IN THE UK

2D products are warranted for one year, the expected life of the ballast and/or Emergency module is 5 years

Doc Ref: WD030/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

Technical Data. 13 Amp Fused Connection Units

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM RANGE INSTALLATION NON-EMERGENCY LUMINAIRES PRE INSTALLATION

Zone 1 Linear Range - Installation Guide

Museum Alkmaar - Alkmaar, Netherlands

Doc Ref: WD024/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

Technical Data. Round Pin And Export Socket Outlets. Brief product description: Features:

Technical Data. Round Pin And Export Socket Outlets. Brief product description: Features:

Floodlight Range Installation Guide

HR25 Solo. Installation and User Instructions. Through the Wall Heat Recovery Ventilators

MANUFACTURED IN THE UK

SWING ARM MAGNIFYING LAMP MODEL NO: SAM170

PIL0478 ISSUE 01/ 07/16

INSTALLATION INSTRUCTION MANUAL

RUNWAY WALL INTRODUCTION APPLICATION

pond and garden 3 x 1 watt / 5 x 1 watt

SPECIFICATION SHEET ORION ROAD LANTERN. IP66 RATED CRI. 230v /50hz

LED Emergency Luminaires

Installation & Operation Instructions. Deluxe LED Spot Light

EXI LED INTRODUCTION APPLICATION PRODUCT SPECIFICATION

LED emergency exit signage from Channel Safety Systems

CONTENT VIPP LAMPS : TIMELESS ILLUMINATION 4-5 IMPORTANT SAFETY INSTRUCTIONS 6-8 VIPP521 TABLE LAMP VIPP522 WALL LAMP 16-23

X20020 INFRESCO P 4kW Issue 4 User manual Date 16/02/16. Page 1 of 9 KEY FEATURES

Beam Type Lamp Type Gear Type. Rated Input Power

HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

FLC131 LED + Linear spread lens IO

Guidelines How To Wire DRH Modules

Motion and Light Sensor Kit LHBAS51

All our Eterna Emergency Exit Signage comply with current Exit Signage Regulations using the Signs Directive format.

CD100 Series. Operators Manual SINGLE COLUMN CARD DISPENSER

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

Operating Instruction for Downlights

OPERATION & MAINTENANCE INSTRUCTIONS

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM E1, E7, S1 and S7 Recessed Ceiling Luminaires

Applications. Standard Colors. Features. T1P Series LED Street Light (Ver2.0)

Battery Charger JCB- SCH20LI.2

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

PROFESSIONAL 270 o PIR MOTION DETECTOR

LED.Commercial 12W LED DD

IQL Helios Area-/Streetlight. User Manual

BBT007/ BBC007/ BBCD007 TOYOTA PRADO 90 Series

Installation Instructions

Installation Instructions

MAGNETO REPLACEMENT. Pre-Unit Twin Cylinder Motorcycles. ELECTRONIC IGNITION SYSTEM For 4 Stroke. With 12 VOLT Electrics, POS/ NEG Ground

Emergency lighting units EM powerled

Single gang PIR switch Replaces a standard light switch or dimmer Turns off automatically Turns on automatically Security mode Switches all lighting,

Emergency lighting units EM powerled

Installation Instructions

BBT033/ BBC033/ BBCD033 TOYOTA HILUX 10/2011

CONGRATULATIONS ON THE PURCHASE OF YOUR THUNDER BAR DRIVING LIGHT

BBT020/ BBC020/ BBCD020 HOLDEN RODEO RA7 & ISUZU DMAX 07+ 2WD & 4WD Models

ETC310-FS LED

Battery Charger JCB-FCH12Li

MAGNETO REPLACEMENT TWIN CYLINDER MOTORCYCLES ELECTRONIC IGNITION SYSTEM FOR 4 STROKE WITH 6 VOLT ELECTRICS, POS/ NEG EARTH SYSTEM TYPE: PAMT1-6

Linear fittings EVTL Weatherproof LED fitting - Industrial applications

TANEK INTRODUCTION APPLICATION PRODUCT SPECIFICATION

Installation Instructions

SUBMERSIBLE WATER PUMP

POOL BARON Nicheless Color Changing LED Pool Light

ADEL - BARA NESO - NG

NOVO LIGHTED MIRROR. Installation Instructions

Emergency lighting units EM series

28W WORK LAMP Model: CTL28 Part No:

Transcription:

10W LED Die Cast Small Rectangle Bulkhead Light Model: LEDBHRE10W Installation & Operating Instructions

1. General Information These instructions should be read carefully and retained for further reference and maintenance. 2. Safety Before installation or maintenance, ensure the mains supply to the luminaire is switched off and the circuit supply fuses are removed or the circuit breaker turned off. It is recommended that a qualified electrician is consulted or used for the installation of this luminaire and install in accordance with the current IEE wiring and Building Regulations. Check that the total load on the circuit including when this luminaire is fitted does not exceed the rating of the circuit cable, fuse or circuit breaker. 1 3. Technical Specifications 230V AC 50 Hz This luminaire is of class I construction and must be earthed 10W LED non replaceable lamp Energy efficiency Class A Energy Usage: 10kWh/1000H Power Factor: Greater or equal to 0.5 Lumen Output: 700lm Colour Temperature: 5000K Operating Temperature: 0 C to +40 C IP65 Rated suitable for restricted external applications CE Certified EC Directives: Conforms to latest directives Dimensions (H x W x D): 218 x 133 x 57mm Mounting Hole Centres: 143mm x 70mm

Alternative bezels available in range (sold separately):- LEDBHRE10ELBH Small Rectangle Eyelid Bezel Horizontal LEDBHRE10ELBV Small Rectangle Eyelid Bezel Vertical LEDBHRE10GRB Small Rectangle Grill Bezel 2 4. Installation Ensure that the mains supply to the circuit breaker is switched off and the circuit supply fuses are removed or the circuit breaker turned OFF. Remove the front of the unit by undoing the 4 Pozi screws and then remove the bezel and lens with gasket. Turn the 2 central fasteners 90 degrees so they match with the slots, this will release the gear tray.

Carefully lift the gear tray and disconnect the 2 way plug. You can do this by holding down the locking bar on one half, at the same time grip the 2 release clips on opposite side and pull. This will disconnect the gear tray completely. 3 Locking bar Release clips Press locking bar with one hand, grip the release clips with the other and pull (push to reconnect). Mark the position of the mounting holes on the wall using the unit as a template (there are provision for 4 mounting holes) and drill the holes ensuring not to infringe with any gas/water pipes or electrical cables that may be hidden below the surface. Insert the rawl plugs into the holes. Pass the 230V 50Hz mains supply cable through the cable entry points on the wall plate, ensuring the grommet is used to maintain the IP rating of the luminaire. Fix the luminaire to the wall using the correct screws for the rawl plugs installed.

4 Terminate the supply cable into the terminal block (See section 5. Connection Diagram) ensuring correct polarity is observed and that all bare conductors are sleeved. Reconnect the 2 way plug the opposite way that was used to disconnect. This can be achieved by holding down the locking bar on one half, at the same time grip the 2 release clips on opposite side and push together. This will re-connect the gear tray. Position the gear tray over the 2 central fasteners. Turn them both 90 degrees so they are opposite to the slots locking the gear tray to the unit. Reposition the lens over the unit, taking care to ensure the gasket is in place. Secure the lens and bezel back into place using the 4 Pozi screws previously removed at the beginning of the installation. Make sure not to overtighten. Note: 4 Allen bolts are also supplied which can be used instead of the four Pozi screws if required. If used a 3mm Allen key is required. You are also able to change the bezel at this stage using one of the alternatives listed at the beginning of these instructions Sold separately.

5. Connection Diagram Connect the 230V 50Hz mains supply cable to the terminal block as marked below; L N 230V~50Hz MAINS SUPPLY 5 L E N ISOLATION SWITCH Live (Brown or Red) to Neutral (Blue or Black) to L N Earth (Green/Yellow) to 6. Operation Turn the power to the bulkhead ON and the unit will illuminate.

3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge. For years 2 and 3 or any difficulty in the first year, telephone the helpline on 020 8450 0515. Note: A proof of purchase is required in all cases. For all eligible replacements (where agreed by Timeguard) the customer is responsible for all shipping/postage charges outside of the UK. All shipping costs are to be paid in advance before a replacement is sent. 6

If you experience problems, do not immediately return the unit to the store. Telephone the Timeguard Customer Helpline; HELPLINE 020 8450 0515 or email helpline@timeguard.com Qualified Customer Support Co-ordinators will be on-line to assist in resolving your query. For a product brochure please contact: Timeguard Limited. Victory Park, 400 Edgware Road, London NW2 6ND Sales Office: 020 8452 1112 or email csc@timeguard.com www.timeguard.com 67.058.551 (Issue 1) Zerofour June 2016