RLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22

Similar documents
EWE. Cooling fins. Ex de

EWE. Ex de. Cooling fins

SLEE. - Suitable for high (+55 C) and low (-50 C) temperatures - Elevated degree of protection IP67 - IIB + H2 marking (hydrogen) - Zones 1, 2, 21, 22

FHL. Ex d. Body in aluminium

EVE. Silicon gasket. Ex de

EXEL-L. Detail of the internal side. Transparent polycarbonate

EXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components

Ex d. S.1 series. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67. SSC series

AVN. - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C. Ex n. Stainless steel clips

YFC. Limit switch. Ex d. 24 operating head types

GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators

CCAI, CCAIF, CCAIF..H

M-0. M-0... series control, monitoring and signalling devices. Ex e

PY, SPY; FSQC, FP; EPC; AP

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

EJB. Ex d. Stainless steel bolts. - Zone 1, 2, 21, 22 - Group IIB+H2 - Aluminium junction boxes - Choice of 30 sizes - IP 66 / 67.

EJB. Ex d. Stainless steel bolts. - Zone 1, 2, 21, 22 - Group IIB+H2 - Aluminium junction boxes - Choice of 30 sizes - IP 66 / 67.

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

Junction boxes for control, monitoring and control panel Ex tb

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Floodlight Series 6121

Emergency Light Fitting for Fluorescent Lamps Series 6009

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Floodlight Series 6521/4

CTB. Ex e. Captive screws B.67. Detail of TIG welding of walls. Earth stud with cable anti-rotation bracket

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof

7 Lighting Technology

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

Compact Sheet-Steel Light Fittings Series 6114/1

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Linear Luminaire with LED Series EXLUX 6402/2

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Linear luminaire with LED Series EXLUX 6002

K: bracket type. L: pole type

L-3000, L-5, L-5R. - High efficiency - Smart energy saving - IP67 protection rating - Exceptional ergonomic design - Zone 0, 1, 2 L-5R L-5 L-3000

Operating Instructions

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Linear Luminaire with LED Series EXLUX 6002

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Operating Instructions

Explosion proof electric motor For Fuel dispensing application. Main characteristic

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

explosive environments Lighting

Sheet-Steel Light Fittings Series 6014 / 6414

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Floodlight LED Series 6525

Pendant Light Fitting IEC

Floodlight LED Series 6525

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

New products Ex Equipment 2015

Control Stations CP.../EFDCN

Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D

INSTRUCTION MANUAL (ATEX / IECEx)

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

Lighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof

Emergency Luminaire with LED Series EXLUX 6409/1

T U N N E L A N D U N D E R P A S S LIGHTING

Floodlight LED Series 6125

LED Linear Luminaire Series EXLUX 6402

Terminal Boxes Series 8125

INSTRUCTION MANUAL (ATEX / IECEx)

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Lighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22

7 Lighting Technology

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

Easy and safe installation

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

Compact Sheet-Steel Light Fittings Series 6114

EX-D ENCLOSURES AND DISTRIBUTIONS

P, I, A. Command and control stations Ex e

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Floodlight fittings HPS, MH or Halogen Floodlight fitting XSF, XQF, XEF - Zones 1, 2

Position Switches Series 8074/2

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22

ATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen

Zone 1 Linear Range - Installation Guide

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

7 Lighting Technology

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Terminal Boxes TNCN. Explosion protection Marking

Tank Inspection Lights Series 6122

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Unused flameproof threads for cable glands have to be closed with certified plugs.

ILED Aquarius Illuminated Windsock. User Manual

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Transcription:

Ex de RLFE Mounting bracket - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22 Stainless steel guard Ex e terminal housing B.1 ED.2018

RLFE series Lighting fixtures for discharge lamps up to 400W RLFE series lighting fixtures for discharge lamps are ideal for lighting large areas specifically in the chemical, on and off shore petrochemical industries. They are certified for use in Zones 1, 2, 21, 22 and comply with the 2014/34/UE directive. The body of the lighting fixture is made from low copper content aluminium alloy, the globe is made of borosilicate glass and has excellent thermal and mechanical properties. For this reason, the fixture can also be installed without a protective guard as specified in the relevant standards. In the RLFE series, the lamp and lamp holder are separated by a chamber housing the ballast and igniter that in turn are separated by a Ex e terminal box that is used to connect the lighting fixture to the power supply through a cable gland with an Ex (non barrier) seal as specified in EN/IEC 60079-14. The ease of access to the different chambers housing the electrical components means lower installation and maintenance costs and less wear and tear over time means a longer lifespan for the lamp. Ex de Application sectors Oil refineries Perimeter lighting Onshore plants Offshore plants Chemical and petrochemical plants Gas plants Naval installations 100% Cortem product CERTIFICATION DATA Classification: Group II Category 2GD Installation: zone 1 - zone 2 (Gas) zone 21 - zone 22 (Dust) Marking: II 2GD Ex e mb IIC T.. Gb - Ex tb IIIC T.. C Db IP66 Certification: ATEX ITS 12 ATEX 17645X IEC Ex ITS 12.0048X TR CU AVAILABLE All IEC Ex and TR CU certification data can be downloaded at www.cortemgroup.com Standards: CENELEC EN 60079-0: 2012, EN 60079-1: 2007, EN 60079-7: 2007, EN 60079-31: 2009 and EUROPEAN DIRECTIVE 2014/34/UE IEC 60079-0: 2011, IEC 60079-1:2007, IEC 60079-7:2006, IEC 60079-31: 2008 European Directive 2006/95 Low voltage European Directive 2004/108 Electromagnetic compatibility European Directive 2003/108 WEEE Waste electrical and electronic equipment European Directive 2011/64 RoHS Class temperature: See selection chart Ambient temperature: -20 C +60 C Degree of protection: IP66 ED.2018 B.2

RLFE series Lighting fixtures for discharge lamps up to 400W Ex d ORIGINAL PRODUCT MECHANICAL FEATURES Body: Globe: Gaskets: Guard: Bolts and screws: Entries: Coating: Low copper content aluminium alloy Fitted with cooling fins for better heat dissipation Shock and temperature resistant borosilicate glass sealed with aluminium shade ring Acid, hydrocarbon and high temperature resistant silicone Electro-polished stainless steel. Stainless steel 2 x ISO M25 entries. Lighting fixture kit with PLG2IB plug and REV2IB cable gland Polyester coating Ral 7035 (light grey) : The STANDARD of the aluminium alloy used by Cortem has passed the tests required by standards EN60068-2-30 (hot/humid cycles) and EN60068-2-11 (salt mist tests) ELECTRICAL FEATURES Lamp holder: E27 or E40 ceramic Ballast: Electromechanical Rated voltage: 230 V AC Rated frequency: 50 Hz Connection: Direct connection to the terminal board L, N, Pe. Section 4mm 2, suitable for input/output Power factor: 0.96 Wiring: Silicone rubber cables with glass braid protection against high temperatures ACCESSORIES AVAILABLE / SPECIAL REQUESTS Discharge lamp Different rated voltages External reflector B.3 ED.2018

RLFE series selection chart Code Dimensions mm A A1 øb C Lamp type Lamp holder Watt Class Ta=+60 C Max surface temp. C RLFE-80N1 425 495 236 250 Sodium vapour E 27 70 T4 113 10,5 425x250x250 Weight kg mm Ex de RLFE-80N2 425 495 236 250 Sodium vapour E 40 100 T4 125 10,5 425x250x250 RLFE-80N4 425 495 236 250 Sodium vapour E 40 150 T4 125 10,5 425x250x250 RLFE-80IM1 425 495 236 250 Metal halide E 27 70 T4 113 10,5 425x250x250 RLFE-80IM2 425 495 236 250 Metal halide E 27 100 T4 125 10,5 425x250x250 RLFE-80IM4 425 495 236 250 Metal halide E 27 150 T4 125 10,5 425x250x250 RLFE-100N5 480 565 310 325 Sodium vapour E 40 250 T4 132 19 480x325x325 RLFE-100IM5 480 565 310 325 Metal halide E 40 250 T4 132 19 480x325x325 RLFE-110N6 575 645 310 325 Sodium vapour E 40 400 T4 129 22 475x325x325 RLFE-110IM6 575 645 310 325 Metal halide E 40 400 T4 129 22 475x325x325 DIMENSIONAL DRAWING DON T FORGET TO ORDER THE ACCESSORIES Esempio: Tipo Armatura UBD5G Example: Type of lighting + + altro... vedi legenda EWL fixture Lamp Dome reflector -80+ Cavallotto per montaggio + a palo + other... see key LAMP400WHQL G110-672 RLFE-110F5 ACCESSORIO RICAMBIO ACCESSORY ED.2018 B.4

RLFE series Accessories and spare parts available on request Ex d ILLUSTRATION DESCRIPTION MODEL FEATURES CODE KEY 70 W (SE70W) LAMPNAV70WPLUS E27 100 W (SE100W) LAMPNAV100WPLUS High pressure sodium vapour lamp 150 W (SE150W) LAMPNAV150WPLUS ACCESSORY E40 250 W (SE250W) LAMPNAV250WPLUS 400 W (SE400W) LAMPNAV400WPLUS 70 W (ME70W) LAMP70WJM E27 100 W (ME100W) LAMP100WJM Metal halide lamp 150 W (ME150W) LAMP150WJM ACCESSORY 250 W (ME250W) LAMP250WJM E40 400 W (ME400W) LAMP400WJM RLFE-80 White painted aluminium G80-672D Dome reflector RLFE-100 Contact our Sales Office for availability ACCESSORY RLFE-110 Contact our Sales Office for availability B.5 ED.2018

RLFE series Accessories and spare parts available on request ILLUSTRATION DESCRIPTION MODEL FEATURES CODE KEY Ex d RLFE-80 G70-0417 Protective guard Material: RLFE-100 Electro-polished stainless G100-0417 steel RLFE-110 G110-0417 RLFE-80 G1-670 Mounting bracket RLFE-100 RLFE-110 Material: galvanised steel G2-670 E27 (RLFE-80) 250V 4A PORT E-27/X Ceramic lamp holder E27 250V 4A PORT E-27 E40 750V 16A PORT E-40 Igniter 50-400W R100 Cable gland ISO M25 (std. range cable 11 20) NAV25IB Metal capacitor Ballast for sodium vapour and metal halide lamp 7 μf F-70 8 μfv F-80 10 μf F-125 12 μf F-12 20 μf F-20 70 W W R-70NAAP 100 W R-100NA 150 W R-150NA 250 W R-250NA 400 W (sodio) 400 W (ioduri) R-400NA R-400 ED.2018 B.6

Installation and mounting methods Ex d Example of pole mounting Example of wall mounting Pole Ø1 1/2 Example of ceiling mounting B.7 ED.2018

Ex d ED.2018 B.8