IMPORTANT Please make certain that persons who are to use this equipment thoroughly read and understand this user s manual prior to operation

Similar documents
Gasoline Inverter Generator

KING CANADA 950W PORTABLE GENERATOR MODEL: KCG-951G INSTRUCTION MANUAL COPYRIGHT 2011 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC.

CG3500i Inverter generator Owner s/user s Manual

GEN3500 i 3,000 MAX WATTS INVERTER GENERATOR INSTRUCTION MANUAL

GEN2000 i 2,000 MAX WATTS INVERTER GENERATOR INSTRUCTION MANUAL

Petrol Inverter Generator USER MANUAL

3kW GENERATOR. Owner s Manual

GEN3500 i 3,500 MAX WATTS INVERTER GENERATOR INSTRUCTION MANUAL

PORTABLE INVERTER GENERATOR MODEL

1200W INVERTER GENERATOR

950 Watts (104609) /1200Watts (104610) /2000Watts (104611) PORTABLE INVERTER GENERATORS. MODELS #104609, # and #

INVERTER GENERATOR P2000i

GASOLINE GENERATOR SET SPG8000 PORTABLE GENERATOR INSTRUCTION MANUAL IMPORTANT!

Generator OWNER S MANUAL. Read this manual carefully before operating this machine. PRO 2.8 i 7VU L1

YK1900i DIGITAL INVERTER GASOLINE GENERATOR OWNER S MANUAL PLEASE READ THIS MANUAL CAREFULLY. IT CONTAINS IMPORTANT SAFETY INFORMATION.

1100W PORTABLE GENERATOR

Engines Original Instructions Model: DG350

No part of this publication may be reproduced without written permission.

Owner s Manual ELECTRIC GENERADORS R7100DP / G7100G

720W PORTABLE GENERATOR

AG-HA-2500N GASOLINE GENERATOR

Make/Type/Size/Model Honda Generator EB 3500X & EB5000X Operators Manual Open Well Ventilated Area to Start & Shut Down Machine

Owner s/operator s Manual

Genquip Gi1000 Digital Inverter Petrol Generator. Owners Manual

INSPECTION/ADJUSTMENT

GENERATOR MODEL NO: FG3005 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0413

3. INSPECTION/ADJUSTMENT

WARNING: Read these instructions before using the machine GENERATOR MODEL NO: IG3500F PART NO: OPERATION & MAINTENANCE INSTRUCTIONS

GENERATOR MODEL NO: FG3000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0609

LAWN MOWER OWNER S MANUAL

8500M INDUSTRIAL GASOLINE GENERATOR OPERATOR S MANUAL

LDG6000SA DIESEL GENERATOR OWNERS MANUAL

AIR-COOLED DIESEL GENERATOR OWNERʼS MANUAL. This manual contains important safety information. TDG2500E TDGW7000E TDG7000SE TDG4500E


Part No FJ180V KAI. 4-stroke air-cooled gasoline engine OWNER, S MANUAL

Owner s Manual Model IN2500i

3. INSPECTION/ADJUSTMENT

Commercial Series Generator Operator Manual (with Kohler Command series engines)

GENERATOR MODEL NO: FG2500 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0114

Owner s Manual PORTABLE GENERATOR. Model: PR2800 PR6500

1-1/2 DIAMETER WATER PUMP

Owner s Manual. GENERATOR EU1000i. o2013 Honda Motor Co., Ltd. -All Rights Reserved. See page 84 for Initial Use Instructions

5.5KVA GENERATOR MODEL NO: PG6500DVES OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0616

Water pump Owner's Manual

Owner s Manual. GENERATOR EB2000i. o2013 Honda Motor Co., Ltd. -All Rights Reserved. See page 78 for Initial Use Instructions

3. INSPECTION/ADJUSTMENT

GX120 GX160 GX200 OWNER S MANUAL 32ZH X32-ZH Serial number and engine type HONDA EUROPE N.V.(EEC)

3KVA DUAL VOLTAGE GENERATOR MODEL NO: PG3800DV

This manual covers the operation and maintenance of water pump: 25ZB21-1.2Q

Owner s Manual. GENERATOR EU3000is. o Honda Motor Co., Ltd. -All Rights Reserved. See page 85 for Initial Use Instructions

142F 144F GASOLINE ENGINE SM-142F-01A INSTRUCTION MANUAL

9500M. WARNING American Fab of SC, LLC Travelers Rest, SC OPERATOR S MANUAL INDUSTRIAL GASOLINE GENERATOR

Operation Manual. 196cc HP GASOLINE ENGINE. Model #

CROMTECH GENERATORS OPERATION & INSTRUCTION MANUAL. Thank you for your selection of a CROMTECH Generator.

GENERATOR MODEL NO: FG4050ES / FG5100ES OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS0310

Gasoline Engine Owner s Manual

Indicates an impending dangerous situation. If this one is not prevented, it can cause death or severe injuries for the user..

AIR CLEANER GENERAL REMOVAL. 1CAUTION Do not run engine without filter element in place. Debris could be drawn into the engine causing damage.

Engine Owner s Manual. Models sx4000, i4000, i4500, i5000, i5500, i7000 & i7000xt. Operating & Maintenance Instructions

4000W GASOLINE DIGITAL INvERTER GENERATOR

1000 RATED WATTS/1200 MAXIMUM WATTS PORTABLE POWER GENERATOR

800W Generator. Original manual AFTER SALES SUPPORT MODEL: WGG-800, 07/2012, 7597

Owner s Manual. GENERATOR EU2000i. o Honda Motor Co., Ltd. -All Rights Reserved. See page 82 for Initial Use Instructions

IMPORTANT INFORMATION

The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

Owner s Manual. 100 Amp. DC WELDER 600W GENERATOR GASOLINE 6.5HP

Owner, s Manual WATER PUMP WT20X WT30X WT40X. C 2012 Honda Motor Co., Ltd. -All Rights Reserved

PETROL INVERTER GENERATOR. Models HY1000Si - HY2000Si

WUXI KIPOR POWER CO., LTD. DIGITAL INVERTER GENERATOR

Genquip Gi2000 Digital Inverter Petrol Generator. Owner s Manual

WUXI KIPOR POWER CO., LTD. DIGITAL INVERTER GENERATOR

IMPORTANT INFORMATION

7000 RATED WATTS/8750 MAXIMUM WATTS PORTABLE POWER GENERATOR

MODEL: AG-HA-950D GENERATOR OWNER S MANUAL

Gasoline Engine GE208 OWNER S MANUAL MODEL NO.

Inverter Generator. specification

2000 WATT DIGITAL GENERATOR

GASOLINE GENERATOR SET USER S MANUAL

HOFFMANN POWER PRODUCTS PARTS LIST 2014

These labels warn you of potential hazards that can cause serious injury. Read them carefully.

OWNER S MANUAL. 2.4kVA Portable Petrol Inverter Generator

FORZA BOLT OUTBOARD MOTOR OWNER S MANUAL

Genquip Gi3300ER DSP Inverter Generator. Owner s Manual GENQUIP GI3300ER DSP INVERTER GENERATOR PAGE 1

PW2750 HOT WATER HI PRESSURE WASHER INSTRUCTION MANUAL

The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

Earth Auger MAG500 MAG500RS

operation manual Model Numbers MC3100PR MC6500ER MC9000ER

Owner s Manual PUMP WB20XT/WB30XT. 201 Honda Motor Co., Ltd. All Rights Reserved

QUESTIONS? Contact your Honda dealer. There is a dealer locator at powerequipment.honda.com

Owner s Manual. GENERATOR EU3000i. o2009 Honda Motor Co., Ltd. -All Rights Reserved. See page 83 for Initial Use Instructions

5625W GASOLINE GENERATOR WITH WHEEL KIT

3. INSPECTION/ADJUSTMENT

SMQGZ F-02 PORTABLE WATER PUMP QGZ F INSTRUCTION MANUAL

800 RATED WATTS/900 MAXIMUM WATTS PORTABLE POWER GENERATOR

WARNING! Ensure that there are no naked flames around the product! Do not smoke while filling fuel and oil!

INSTRUCTIONS 1kW Propane Autonomous Power Unit Kit

500Wi Digital Inverter Generator By POWERHOUSE

9000RC INDUSTRIAL GASOLINE GENERATOR OPERATOR S MANUAL

Owner s Manual. GENERATOR EU6500is. o2007 Honda Motor Co., Ltd. -All Rights Reserved. See page 78 for instructions on assembling your generator

GENERATOR MODEL NO: DG6000DVES OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1216

Transcription:

IMPORTANT Please make certain that persons who are to use this equipment thoroughly read and understand this user s manual prior to operation USER S MANUAL

OUTDOOR USE ONLY! PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THE MACHINE. 1. SAFETY INFORMATION 1. GENERAtoR LocAtioN NEVER operate the generator inside any building, including garages, basements, crawlspaces and sheds, enclosure or compartments, including the generator compartment of a recreational vehicle or trailer. Please consult your local authority. In some areas, generators must be registered with the local utility. Generators used at construction sites may be subject to additional rules and regulations. Generators should be on a flat, level surface at all times, including times of nonoperation. Generators must have at least five feet of clearance from all combustible material. In addition to clearance from all combustible material, generators must also have at least three feet of clearance on all sides to allow for adequate cooling, maintenance and servicing. Generators should never be started or operated in the back of a SUV, camper, trailer, in the bed of a truck (regular, flat or otherwise), under staircases/stairwells, next to walls or buildings, or in any other location that will not allow for adequate cooling of the generator and/or the muffler. DO NOT contain generators during operation. Allow generators to properly cool before transport, re-fueling, or storage. Place the generator in a well-ventilated area. DO NOT place the generator near vents or intakes where exhaust fumes could be drawn into occupied or confined spaces. Carefully consider wind direction when positioning generator for operation. 2. EXHAUST FUMES ARE POISONOUS Never operate the engine in a closed area or it may cause unconsciousness and death within a short time. Operate the engine in a well ventilated area. 3. FUEL IS HIGHLY FLAMMAE AND POISONOUS Always turn off the engine when refueling Never refuel while smoking or in the vicinity of an open flame. Take care not to spill any fuel on the engine or muffler when refueling. If you swallow any fuel, inhale fuel vapor, or allow any to get in your eyes, see your doctor immediately. If any fuel spills on your skin or clothing, immediately wash with soap and water and change your clothes. When operating or transporting the machine, be sure it is kept upright. If it tilts, fuel may leak from the carburetor or fuel tank.

4. ENGINE AND MUFFLER MAY BE HOT Place the machine in a place where pedestrians or children are not likely to touch the machine. Avoid placing any flammable materials near the exhaust outlet during operation. Keep the machine at least 1 m ( 3 ft ) from buildings or other equipment, or the engine may overheat. Avoid operating the engine with a dust cover. Be sure to carry the generator only by its carrying handle. Put the machine on flat ground, to allow proper air flow for cooling. 5. ELECTRIC SHOCK PREVENTION Never operate the engine in rain or snow. Never touch the machine with wet hands NOTE: Use ground (earth) lead of sufficient current capacity. Diameter: 0.12mm (0.005 in)/ampere EX: 10 Ampere --1.2mm (0.055 in) cool air cool air hot hot 6. CONNECTION NOTES Avoid connecting the generator to commercial power outlet. Avoid connecting the generator in parallel with any other generator.

2. CONTROL FUNCTION (1) Fuel tank (2) Fuel tank cap (3) Fuel filter (4) Carrying handle (5) Muffler (6) Spark plug (7) Choke lever (8) Recoil starter (9) Fuel cock (10) Brake lever 15 1 2 3 4 (11) Wheel (12) Oil filler cap (13) Air filter (14) Fuel pump (15) Battery (16) Oil Alert (17) Overload indicator light (18) AC pilot light (19) Smart throttle (20) Info panel (21) DC circuit breaker (22) Ignition switch (23) DC receptacle (24) Ground (earth) terminal (25) AC receptacle L5-30R (26) AC receptacle 5-20R (27) Parallel connection socket (28)Parallel connection control socket 5 6 7 8 9 10 11 19 20 16 17 18 V A KW HZ AC 120V AC 120V MODE 28 27 12 13 14 L 5-3 0 R DC PROTECTOR STOP RUN DC12V 5A 3 0 A1 2 5 V 21 22 23 25 26 24 START

1. OIL WARNING SYSTEM When the oil level falls below the lower level, the engine stops automatically. Unless you refill with oil, the engine will not start again. 2. ENGINE SWITCH The engine switch controls the ignition system. (1) ON (run) Ignition circuit is switched on. The engine can be started. (2) STOP Ignition circuit is switched off. The engine will not run. (3) START Starting circuit is switched on. The starter motor starts. 3. SMART THROTTLE SWITCH When the Smart throttle switch is turned ON, the economy control unit controls the engine speed according to the connected load. The results are better fuel efficiency and less noise. 4. DC CIRCUIT PROTECTOR The DC circuit protector turns off automatically when the load exceeds the generators rated output. CAUTION: Reduce the load to within specified generator rated output if the DC circuit protector turns off. 5. FUEL COCK The fuel cock is used to supply fuel from the tank to the carburetor.

.6 REMOTE CONTROL SWITCH The remote control switch controls the ignition system ON The starter motor starts. OFF The engine will not run. 7. BRAKE LEVER The function of brake lever is to prevent the generator from moving. Brake lever is not working, generator can move. Brake lever is working, generator can t move. OFF 1 ON ON OFF OFF ON 2 3. PRE-OPERATION CHECK CAUTION: Add more than 1.32 gal of fuel for the first time to use this machine. Pre-operation checks should be made each time the generator is used. 1. CHECK ENGINE FUEL Make sure there is sufficient fuel in the tank. If fuel is low, refill with unleaded automotive gasoline. Be sure to use the fuel filter screen on the fuel filter neck. Recommended fuel: 87 octane+. Do not use gasoline containing more than 10% ethanol. Gasoline containing higher levels of ethanol is corrosive and attracts moisture, which can cause start or running problems, and in some cases damage the generators fuel system. Damage to generator from ethanol enriched fuels is not covered by warranty. WARNING: Refuel in well-ventilated area before starting the generator. If engine has been running, allow it to cool before restarting. Do not refill tank while engine is running or hot. Close fuel cock before refueling with fuel. Be careful not to admit dust, dirt, water or other foreign objects into fuel. Do not fill above the top of the fuel filter or it may overflow when the fuel heats up later and expands. Wipe off spilt fuel thoroughly before starting engine. Keep away from open flames.

2. CHECK ENGINE OIL Make sure the engine oil is at the upper level of the oil filler hole. Add oil as necessary. Remove oil filler cap and check the engine oil level. If oil level is below the lower level line, refill with suitable oil to upper level line. Do not screw in the oil filler cap when checking oil level. Change oil if contaminated. Oil capacity. Recommended engine oil: API Service SJ 3. GROUND (Earth) Make sure to ground (earth) the generator. 4.CONNECT BATTERY (for electric starting system) Loosen the screw and remove the battery cover. Clamp the red wire to the positive (+) terminal and the black wire to the negative (-) terminal of the battery. Do not reverse these positions. Be sure the battery is installed on the battery mount tray securely. Install the cover and tighten the screw. UPPER LEVEL CAUTION: Recommended battery: 12V6AH

4. OPERATION WARNING: The generator has been shipped without engine oil. Fill with oil or it will not start. Do not tilt the generator when adding engine oil. This could result in overfilling and damage to the engine 1. STARTING THE ENGINE NOTE: Before starting the engine, do not connect the electric apparatus. ON A Recoil start 1. Turn the fuel cock lever to the ON position. Press primer bulb. 2. Turn the engine switch to the ON or RUN position. 3. Turn the choke lever to the position. Not necessary if the engine is started using the remote. 4. Pull the starter handle slowly until resistance is felt. This is the Compression point. Return the handle to its original position and pull swiftly. Do not fully pull out the rope. After starting, allow the starter handle to return to its original position while still holding the handle. Grasp the carrying handle firmly to prevent the generator from falling over when pulling the recoil starter. 5. Warm up the engine. 6. Turn the choke lever back to the operating position. Not necessary if the engine is electric type. 7. Warm up the engine without a load for a few minutes. B Electric start 1. Turn the fuel cock lever to the ON position. 2. Turn the engine switch to the START position. 3. Turn on CHOKE. 4. Turn the engine switch to the RUN position 5. Warm up the engine without a load for a few minutes. 6. Turn CHOKE off. ENGINE SWITCH STOP RUN START

4. OPERATION (Continued) C Remote start 1. Turn the fuel cock lever to the ON position. 2. Turn the engine switch to the RUN position. 3. Slowly click the ON button twice. 4. Warm up the engine without a load for a few minutes. 2. USING ELECTRIC POWER 1. AC APPLICATION (a) Check the Info panel for proper voltage. (b) Turn off the switch(es) of the electrical appliance(s) before connecting to the generator. (c) Insert the plug(s) of the electrical appliance(s) into the receptacle. CAUTION: Be sure the electric apparatus is turned off before plugging in. Be sure the total load is within generator rated output. Be sure the socket load current is within socket rated current. The smart throttle switch must be turned to OFF when using electric devices that require a large starting current, such as a compressor or submersible pump. ENGINE SWITCH STOP STOP RUN ENGINE SWITCH START RUN START ENGINE SWITCH STOP RUN START 2. OVERLOAD INDICATOR LIGHT The overload indicator light comes on when an overload of a connected electrical device is detected, the inverter unit overheats, or the AC output voltage rises. The electronic breaker will then activate, stopping power to the generation in order to protect the generator and any connected electric devices. The output pilot light (green) will flicker and the overload indicator light (red) will turn on, then the engine will stop running. If so please follow the following steps: (a) Turn off any connected electric devices and stop the engine (b) Reduce the total wattage of connected electric devices within the application range. (c) Check for blockages in the cooling air inlet and around the control unit. If any blockages are found, remove. (d) After checking, restart the engine. ON ON OFF OFF ON

CAUTION: The generator AC output automatically resets when the engine is stopped and then restarted. The overload indicator light may come on for a few seconds at first when using electric devices that require a large starting current, such as a compressor or a submersible pump. However, this is not a malfunction. 3. DC APPLICATION (option) This usage is applicable to 12V battery charging only. (a) Charging instruction for battery Disconnect the leads for the battery. Loosen battery filler cap. If the battery fluid is low level, Fill distilled water to the upper limit. Measure the specific gravity for the battery fluid by using the hydrometer, and calculate the charging time in according with the table shown on right side. The specific gravity for the fully charged battery shall be within 1.26 to 1.28. It is recommended to confirm every an hour. (b) Connect between the DC output socket and the battery terminals using the charging leads. The leads shall be connected making sure of the (+) and (-) polarity. (c) The DC circuit protector is to be set to ON after confirming the connection, if the protector is in OFF position. Aim for specific gravity and charging time Specific gravity 68 F 1.30 1.26 1.22 1.18 1.14 1.10 1.06 0 Battery capacity 1. 30AH 20HR 2. 35AH 20HR 3. 47AH 20HR 1 2 2 4 6 charging time Hr 3 8 10 CAUTION: Be sure the smart throttle switch is turned off while charging the battery. * Always charge per battery manufacture recommendations.

3. STOPPING THE ENGINE 1. Turn off the power switch of the electric apparatus or disconnect any electric devices. 2. Turn the engine switch to STOP position. Click remote switch to the OFF position. 3. Turn the fuel cock lever to OFF. 4. Allow engine to cool before restarting. ENGINE SWITCH STOP RUN START ON ON OFF OFF OFF OFF

5. PERIODIC MAINTENANCE 1) MAINTENANCE CHART Regular maintenance is most important for the best performance and safe operation. The maintenance schedule applies to normal operating conditions. If you operate your generator under unusual or harsh conditions, such as sustained high-load or high-temperature operation, or use it in dusty conditions, service interval time will decrease. If used in dusty/harsh environments, clean out generator by removing side panels and using compressed air. Item Remarks Pre-operation check (daily) Spark Plug Check condition adjust gap and clean. Initial 1 month or 20 Hr Every 3 months or 50Hr Every 6 months or100hr Replace if necessary. Engine Check oil level Oil Replace Oil Clean oil filter Air Filter Fuel Filter Choke Valve Clearance Fuel Line Exhaust System Carburetor Cooling system Starting system Idle speed Fittings / Fasteners Crankcase breather Generator Clean. Replace if necessary. Clean fuel cock filter. Replace if necessary Check choke operation Check and adjust when engine is cold. Check fuel hose for crack or damage. Replace if necessary. Check for leakage. Re-tighten or replace gasket if necessary Check muffler screen. Clean / replace if necessary. Check choke operation Check fan damage. Check recoil starter operation. Check and adjust engine idle speed Check all fittings and fasteners correct if necessary. Check breather hose for cracks or damage. Replace if necessary Check the pilot light comes on Every 12 months or100hr

2. ENGINE OIL REPLACEMENT 1. Place the machine on a level surface and warm up the engine for several minutes. Then stop the engine and turn the fuel cock knob to OFF. 2. Loosen the screw and remove the cover. 3. Remove the oil filler cap 4. Place an oil pan under the engine. Tilt the generator to drain the oil completely 5. Replace the generator on a level surface. 6. Add engine oil to the upper level. 6.5. DO NOT screw in dipstick when checking oil level 7. Install the oil filler cap 8. Install the cover and tighten the screw Recommended engine oil. API Service SJ CAUTION: Be sure no foreign material enters the crankcase. Do not tilt the generator when adding engine oil. This could result in overfilling and damage to the engine Clean the oil filter every 100hrs. UPPER LEVEL 3. AIR FILTER Maintaining an air cleaner in proper condition is very important. Dirt induced through improperly installed, improperly serviced, or inadequate elements damages and wears out engines. Keep the element always clean. 1. Remove the cover. 2. Remove the air filter cover and element. 3. Wash the element in solvent and dry. 4. Oil the element and squeeze out excess oil. The element should be wet but not dripping. 5. Insert the element into the air filter. 6. Install the cover OIL FILTER

4. CLEANING AND ADJUSTING SPARK PLUG 1. Remove the cover. 2. Check for discoloration and remove the carbon. 3. Check the spark plug type and gap. 4. Install the spark plug. 5. Install the cover WARNING: A loose spark plug can overheat and damage the engine. Standard electrode color: Tan Color Standard Spark Plug: A7RTC Torch Spark Plug Gap: 1.0-1.3 mm (0.039-0.051 in) 5. FUEL TANK FILTER 1. Remove the fuel tank cap and filter. 2. Clean the filter with solvent. If damaged, replace. 3. Wipe the filter and insert it. WARNING: Be sure the tank cap is tightened securely. 6. MUFFLER SCREEN 1. Remove the cover. 2. Remove the muffler screen. 3. Use the flathead screw driver to pry the spark arrester out from the muffler 4. Remove the carbon deposits on the muffler screen and spark arrester using a wire brush. 5. Install the muffler screen. 6. Install the cover WARNING: The engine and muffler will be very hot after the engine has been run. Avoid touching the engine and muffler while they are still hot with any part of your body or clothing during inspection or repair.

6. TROUE SHOOTING (1) Engine won t start 1. Fuel systems No fuel supplied to combustion chamber. No fuel in tank.supply fuel. Fuel in tank.fuel cock knob to ON. Clogged fuel line.clean fuel line. clogged carburetor.clean carburetor. Allow hot engine to cool before restarting. (2) Engine oil system Insufficient Oil level is low.add engine oil. (3) Electrical systems Poor spark Spark plug dirty with carbon or wet. Remove carbon or wipe spark plug dry. Faulty ignition system.consult dealer. (4) Compression insufficient Worn out piston and cylinder.consult dealer. (5) Generator won t produce power Circuit breaker (AC) to OFF Stop the engine, then restart. Circuit breaker (DC) to OFF Press to reset the DC protector (6) Generator output will be reduced in high altitude conditions and while using E10 fuel. For best performance use non-ethanol blended fuel.

7. STORAGE Long term storage(90+ days) of your machine will require some preventive procedures to guard against deterioration. Note: Do not use plastic sheet as a dust cover. A nonporous cover will trap moisture promoting rust and corrosion. 1.DRAIN THE FUEL 1. Remove the fuel tank cap, drain the fuel from the fuel tank 2. Remove the cover, drain fuel from the carburetor by loosening the drain screw. 2. ENGINE 1. Remove the spark plug, pour in about one tablespoon of SAE 10W30 or 20W40 motor oil into the spark plug hole and reinstall the spark plug. 2. Use the recoil starter to turn the engine over several times (with ignition off). 3. pull the recoil starter until you feel compression. 4. Stop pulling. 5. Clean exterior of the generator and apply a rust inhibitor. 6. Store the generator in a dry, well-ventilated place, with a cover placed over it. 7. The generator must remain in a vertical position. 8. Remove battery and use a battery maintainer for motorcycle batteries. 3. Short term storage 1. Add fuel stabilizer immediately to fresh fuel in a canister. Mix well before fueling up generator. 2. Allow generator to run at least 10 minutes to allow treated gasoline to replace the untreated gasoline in the fuel system. 3. Turn off fuel valve and allow generator to continue running till it runs out of gasoline. Turn off generators ignition system. 4. Top off fuel tank with treated gasoline. Air in the fuel tank will promote fuel deterioration.

SPECIFICATION 149.5 cc 5.4 HP / 5500 rpm 6.4 Liters / 1.69 gal 4.8 hours (100% load) 6.7 hours (50% load) 0.95 Quarts / 0.9 Liters 24.2 x13.5 x19.9 25.2 x14.2 x21.3 37 kgs/81.6 lbs 40 kgs/88.2 lbs

WIRING DIAGRAM 2600i M R R 0 0 W PI BU W BREAKER Y/G Main winding Stepping motor Control winding R W W R Invert cell R BU 0 W R R GR BU Y/G O W R P Economic switch OUTPUT OVERLOAD LOW OIL Oil sensor Ignition winding W R Spring winding P High pressure wrap Spark plug R Gr Engine switch BATTERY FUSE 3A RECTIFIER R W FUSE 3A BU BU BREAKER DC winding BU BU Y/G ENGINE SWITCH CONTINUTY

Replacement Parts Part # Description 2786-01 Parallel Cable 2786-02 Spring of oil-filter 2786-03 Oil Strainer 2786-04 Oil Filter 2786-05 Air Filter 2786-06 Fuel Strainer 2786-07 Fuel Filter 2786-08 Fuel Tubes set 2786-09 Spark Arrestor 2786-10 Muffler Gasket 2786-11 Carburetor 2786-12 Recoil Starter 2786-13 Ignition Controller 2786-14 Wireless remote and receiver 2786-15 Starting relay 2786-16 Fuel Pump 2786-17 Battery 2786-18 Gas Cap 2786-19 Handle*2 2786-20 Pull Start side panel 2786-21 Other side panel 2786-22 Rear Panel 2786-23 Wheel 2786-24 Top Panel/door 2786-25 Oil Cap 2786-26 Decal Set 2786-27 Battery hold down strap 2786-28 Ignition Key 2786-29 Spark Plug 2786-30 Choke assy 2786-31 Battery charging cord 2786-32 Inverter assy 2786-33 Ignition coil 2786-34 Control panel assy 2786-35 Wheel's brake 2786-36 Hardware set

2786 Generator wearing parts list No. Item Qty (pc/set) Pictures No. Item Qty (pc/set) Pictures 1 Spark plug A7RTC 1 12 R ecoil starter 1set 2 Oil filler cap Oring 1 13 Lgnition controller IC-2500 1 3 Oil strainer 1 4 Oil filter 1set 14 Remote& Wireless receiver 1set 5 Air filter Assy 1set 15 Starting reply 1set 16 Quadripuntal fuel pump 1set 6 Fuel strainer 1 7 Fuel filter 1 Note: Customer can easy to replaced all wearing parts. 8 Fuel tubes 1 9 Spark attestor 1 10 Muffler gasket 1 11 Carburetor 1set

2786 Wearing parts replacement instructions 1. Spark Plug A7RTC Replacement 1. Generator ready 2. Remove top cover 3. Pull spark plug cover out Generator 4. Install top cover tightly 5. Push spark plug cover back tightly Check gap 1~1.3mm Customized wrench in tooling bag, when you open carton you will see the tool bag 6. Use tools to unscrew spark plug 7. Take spark plug out 8. Check spark plug condition, adjust gap and clean, replaced if necessary 9. Re-install spark plug back tightly 2. If oil warning light on, fill Oil Below is how to fill Oil Unscrew 2bolts with red circle Replaced the Oring if necessary Add engine oil to the upper level line Install the oil filler cap 5ghtly Push cover upward then removed it Unscrew oil filler cap Remove oil filler cap 1. Remove right side cover 2. Remove oil filler cap 3. Check oil level and add oil. DO NOT screw in cap when checking oil. 4. Install right side cover tightly 5. Install the oil filler cap tightly

3: Oil strainer replacement Check oil strainer clean or not, replaced it if necessary Removed oil strainer cap Oil strainer cap cover in geneator bo1om Unscrew oil strainer cap 1. Remove oil strainer cap cover 4: Fuel bulb replacement 2. Remove oil strainer cap 3. Take oil strainer out 4. Install oil strainer cover tightly 5. Install oil strainer cap tightly Unscrew 2bolts with red circle Push cover upward then removed it Push fuel bulb bracket then pull fuel bulb outward Pull fuel bulb out Take fuel bulb out and check inside. inspect if clean /bo5om for leakage or not. Replaced it if necessary 1. Remove right side cover 2. Take fuel bulb out 3. Check fuel bulb. 4. Clean or replace. 5. Reinstall fuel bulb onto generator. 6. Reconnect fuel bulb. 5: Air filter assy replacement Unscrew 2bolts with red circle Push cover upward then removed it Unscrew 3bolts with red circle Pull air filter assy outward Open air filter cover Take foam out, clean or replaced it if necessary 1. Remove right side cover 2. Unscrew 3 bolts 3. Pull air filter assy outward 4. Open air filter cover 3. Check foam. Clean or replace if necessary 4. Install right side cover tightly. 5. Tighten air filter cover. 6. Close air filter cover 7. Reinstall air filter.

2786 Wearing parts replacement instructions 6: Fuel strainer replacement Check fuel stainer. Clean, replaced if necessary 1. Remove fuel cap 2. Pull fuel stainer out upward 3. Check fuel strainer, clean or replace if necessary 4. Reinstall fuel strainer. 5. Reinstall fuel cover tightly. 7: Fuel filter replacement Unscrew 2bolts with red circle Pinch brackets then pull fuel tubes out Pinched brackets then pull fuel tubes out Push cover upward then remove it 1. Remove right side cover 2. Fuel filter. 3. Inspect fuel filter, replace if necessary. check fuel filter, replace if necessary 4. Install fuel filter back 5. Install fuel tubes back tightly. 6. Install right side cover back.

8: Fuel line tube replacement Pinch brackets then pull fuel tubes out Pinched brackets then pull fuel tubes out 1. Pinch brackets then pull tubes out, check tubes for leakage/cracking, replace it if necessary. 9: Spark arrestor replacement Unscrew spark a,estor then take it out Unscrew 4pcs bolts, take muffler cover off Spark arrestor Check spark arrestor, clean or replace if necessary 1. Take muffler cover off. 2. Unscrew spark arrestor, take it out to check and clean. 3. Install muffler cover tightly. 4. Reinstall spark arrestor tightly. 10: Muffler gasket replacement Unscrew 4pcs bolts, take muffler cover off Check muffler gasket, replaced if necessary 1. Take muffler cover out. 2. Unscrew muffler bolts, take muffler out 3. Install muffler cover tightly. 4. Install muffler back tightly.

2786 Wearing parts replacement instructions 11: Carburetor replacement Unscrew 2bolts with red circle Replaced new carburetor if necessary Find Carburetor Push cover upward then remove it Removed air filter assy first Pull carburetor outward 1. Remove right side cover 2. Remove air filter assy first 3. Take carburetor out. 4. Replaced with new carburetor if necessary 5. Install right side cover tightly. 6. Install air filter assy back tightly 7. Reinstall carburetor tightly 12: Recoil starter replacement Inverter assy Unscrew recoil starter moun0ng bolts then replace with new one Unscrew the bolt, let recoil handle back in inside Unscrew 4bolts,remove control panel Control panel 1. Remove control panel. 2. Remove inverter assy. 3. Remove hand backing cover. 4. Replaced recoil starter. 5. Install control panel back tightly. 6. Install inverter assy back tightly. 7. Pull recoil starter handle out then install hand back cover tightly. 8. Install new recoil starter tightly. 13: Ignition controller IC-2500 replacement Replaced new lgni-on controller if necessary Unscrew 4bolts,remove control panel 1. Remove control panel. 2. Remove old ignition controller. 3. Install control panel back tightly. 4. Install new ignition controller.

14: Wireless remote & receiver replacement Wireless receiver Unscrew 4bolts,remove control panel 1:Unscrew wireless receiver bracket bolts 2: Remove wireless receiver connect wires 3:Removed wireless receiver 1:Mount new wireless receiver 2: Connect new wireless receiver 3: Use new matching remote 1. Remove control panel. 2. Remove old wireless receiver. 3. Replace new wireless receiver & Remote. 4. Remount control panel back tightly. 5. Test new wireless receiver & remote. 6. Mount new wireless receiver back tightly 15: Starting relay replacement Unscrew 2bolts with red circle Push cover upward then removed it Star8ng relay 1:Remove connected wires 2:Remove moun3ng bolts 3:Take star3ng relay out 1:Mount new star.ng relay 2: Reconnect all wires 1. Remove left side cover. 2. Remove starting relay. 3. Replaced new starting relay 4. Install left side cover back 5. Install new starting relay back tightly 16: Quadripuntal fuel pump replacement Unscrew 2bolts with red circle Push cover upward then remove it Qudripuntal fuel pump 1:Unscrew qudripuntal fuel pump moun7ng bolts 2:Remove fuel tubes 3: Replace with new qudripuntal fuel pump 1. Remove right side cover 2. Remove fuel tubes,then take qudripuntal fuel pump out. 3. Install right side cover tightly. 4. Replace with new qudripuntal pump.