The complete offer Enclosed switch-disconnectors / Isolators

Similar documents
Enclosed switches and safety switches Main Catalogue. 2CMC341002D0002 January 2009

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Enclosed Switches and Safety Switches

AC Switches: ML & MN Series DC Switches: MDC1A Series

I Ex-Safety switches I

Brocure panorama. Switches for photovoltaic applications Disconnect switches OTDC and OTDCP

KATKO Safety Switches:

ATX PRE Series 125 Amp Plugs and Sockets Increased Safety

Low Voltage Products. Enclosed switches. Brochure OT_KSE 1 GB 05_02 1SCC340007C0201

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Switches Section 1. Load Break Switches. Accessories for Load Break Switches. 4 Pole Part Price Each Reference

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA

ATX PRE Series 63 Amp Plugs and Sockets Increased Safety

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Rotating Power AC Motors and Generators

PRE Series 125 Amp Plugs and Sockets Increased Safety

Low Voltage Products. Breakers and Switches for the HVAC segment

Switch Disconnectors

SWITCH DISCONNECTORS PLANET -SWITCH.

ATX DPD Series Distribution Panelboards Flameproof

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

PKZ and PKE motor-protective circuit-breakers

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

SAFETY SWITCHES / ISOLATORS A TECHNICAL DATA

WLP Disconnect Switches for Solar and other Applications

Enclosed DC rated switch-disconnectors OTDCP from 16 to 32 Amperes

I Ex-safety switches I

PRE Series 63 Amp Plugs and Sockets Increased Safety

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Plugs & Sockets PRE Series: 16 A Plugs and Sockets Increased Safety

SACE Tmax XT. New low voltage moulded-case circuit-breakers up to 250A.

D509E. Manual Motor - Starters

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

SIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

Switch-disconnectors OTDC and OTDCP

Application Mini Contactors for Motors and Resistive Loads

DisconnectSwitches16Ato250A Enclosed,DoorMountandPanelMountDisconnects 3,4,and6PoleModels 3PadlockableHandle Styles Add-onPowerContacts Auxiliary

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

TUNNEL54. Safety and fire resistance VENTILATION LIGHTING

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

Safety Switches Series 8537

PowerLine OS Switch Fuses A, 690V

NPA-CP. Pendant control station OPTIONS FEATURES CERTIFICATIONS

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC

FONTECK INDUSTRIES Glasblazerstraat 12E, 2984 BL Ridderkerk, The Netherlands Tel: +31 (0) Fax: +31 (0)

Enclosed switch & safety enclosure. for local and safety breaking applications

C E R T I F I C A T E O F C O M P L I A N C E

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

Contents. Volume 5 Motor Control and Protection CA E December

Move to modern enclosed disconnect switch technology. Enclosed disconnect switches eot Manual motor controllers

Medium Voltage Metal-Enclosed Switches

Compact Load Break Switches 16A to 125A

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC

IP41. Enclosed Switchgear. Hinged Lid IP41 Enclosures. for technical support call: +44(0) General Description.

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

Arc flash hazard mitigation

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

MS General Information Extended Product Type: MS

TeSys Enclosed Starters. Let TeSys watch over your machinery

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

SERIES D DISCONNECTS SWITCHES. 16 Amp Amp 600 & 1000 Volt. Featuring:

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

10 Load and Motor Switchgear

SIRCO M and MV Universal load break switches from 16 to 160 A

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

A compact range of Switch-Disconnectors with the capacity to add auxiliary and neutral block options to the basic load break switch block.

NPA-CP Pendant Control Station

Operating voltage 120, 230 V AC Air volume 24 m³/h (14.1 CFM) Rated power 13 W Size 1

Product Specification Sheet #3LD2.1

SECTION PANELBOARDS

Ø64 LOAD BREAK SWITCHES Ø4.5 Ø12 Ø48. Panel Door

Position Switches Series 8060/2

FONTECK INDUSTRIES Glasblazerstraat 12E, 2984 BL Ridderkerk, The Netherlands Tel: +31 (0) Fax: +31 (0)

E 90 range of fuse disconnectors and fuseholders Uncompromising performance

INDUSTRIAL PLUGS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates

Main current switches >180 A are realized in metal enclosures. Internationally approved.

TeSys Enclosed Starters. Let TeSys ensure safety in your simple motor applications

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators

Low Voltage Switches. Enclosed switches - eot Manual motor controllers and disconnects

LOAD BREAK SWITCHES AND SWITCH FUSES

Position Switches Series 8070/2

Phelan. Electromec ELECTROMEC LOAD BREAK SWITCHES. APPROVALS For Canada and US APPLICATIONS DESIGN FEATURES

XACA871 pendant control station XAC-A - 8 pushbuttons

Technical Brochure. Rotary Type Installation Switches A, 500 V. Brochure OT_M 22 GB D Low Voltage Products

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN

Rossi S.p.A a company of the Habasit Group -Copyright: all right reserved- Author: R&D - Electric Motors Division 1

Catalog. Industrial Plugs & Sockets

Unicode 2 Series Pre-Drilled Control Stations Increased Safety Polyamide, Fiberglass Reinforced Polyester, 316L Stainless Steel, Aluminum

BARON-MAX V Range Vertical Machining Centers Powerful Machines, Simple User Friendly Programming At a Very Affordable Pricing

Transcription:

June 2009 The complete offer Enclosed switch-disconnectors / Isolators May 29, 2009 Slide 1

Contents Why use enclosed switch-disconnectors Applications and application demands The ABB products and features Technical documentation Conclusion Link to flash-plugin May 29, 2009 Slide 2

Why use enclosed switch-disconnectors Local isolation Main switch Control switch Fireman switch Etc. May 29, 2009 Slide 3

Why use enclosed switch-disconnectors Personal safety Maintenance isolation Electrical isolation Safety standards Machine Directive EN60204 Definitions Machine Directive EN60204 May 29, 2009 Slide 4

Where to find the applications Air conditioners / chillers Elevators Ventilation fans Lighting Corn drier Conveyor belts Car washing machines Washing machines Restaurant kitchens Electrical distribution systems May 29, 2009 Slide 7

Example of industrial application May 29, 2009 Slide 8

Example of industrial application May 29, 2009 Slide 9

Example of industrial application May 29, 2009 Slide 10

Example of industrial application May 29, 2009 Slide 11

Example of solar application May 29, 2009 Slide 12

Example of application May 29, 2009 Slide 13

Example of application Local isolation May 29, 2009 Slide 14

Example of application Main switch May 29, 2009 Slide 15

Example of application Control switch May 29, 2009 Slide 16

Example of application Fireman switch Fireman switch May 29, 2009 Slide 17

Ratings to utilization categories Enclosed switch-disconnectors AC-21A AC-22A AC-23A Utilization categories AC Utilization categories DC May 29, 2009 Slide 18

The complete range Switch disconnectors / Isolators EN 60947-3, Ue 400 V Ie AC-21, 22A 25 40 63 80 100 125 160 270 315 500 630 720 1000 1250 1600 May 29, 2009 Slide 21 Ie AC-23A 16 32 45 75 80 90 125 250 315 500 630 720 800 1000 1250 Plastic BW,P BW,P P P P P Aluminum KSE KSE KSE KSE KSE KSE KSE KSE KSE KSE Steel sheet L, L, L, L, L, L, Stainless sheet R R R R R R

Wide range of functions 2, 3, 4 and 6 pole Auxiliary blocks Early brake and late make auxiliary contact for electrical interlocking All enclosed switches can be fitted with additional contact blocks. May 29, 2009 Slide 22

Early brake, late make May 29, 2009 Slide 23

Enclosed change-over switch May 29, 2009 Slide 24

For safety and reliability Front operated High quality enclosure material Plastic Steel Aluminum Stainless steel AISI 304 Acid proof steel AISI 316 AC-22A = <1600A AC-23A = <1250A May 29, 2009 Slide 25

For safety and reliability Side operated Handle, axis & insert is one system, factory assembled by ABB Knockouts for padlock in I position AC-22A = < 40A AC-23A = < 25A High quality enclosure material Aluminum Plastic/PBT Properties of plastic material May 29, 2009 Slide 26

For safety and reliability Padlockable in the Off position as standard Shackle for up to 6 padlocks May 29, 2009 Slide 28

For safety and reliability To prevent personal injury in case of short circuit when operating the switch On all aluminum enclosures with Ie > 160 A On all steel sheet enclosures with Ie > 125 A May 29, 2009 Slide 29

For the user Easy installation Clear marking of ratings Threaded cable entries Knockouts on plastic enclosures Drilling plan on the backside Clear molded position indication (I-O) May 29, 2009 Slide 30

Approvals and certificates Standards EN 60947-3 UL ATEX EMC Environment declaration CE declaration of conformity May 29, 2009 Slide 32

Technical documentation Available on Internet and in ABB Library Dimension drawings and drilling plans Selection tool Circuit diagrams Operating instructions Approvals/certificates Printed materials/sales documentation For more information please visit : www.abb.com www.switchselector.com May 29, 2009 Slide 33

ABB Your local partner globally Complete range of products Availability all around the world Local sales companies in over 130 countries May 29, 2009 Slide 34

Conclusion A safe solution For a wide range of applications Designed for safe and easy use Corresponding to international standards May 29, 2009 Slide 35