KEOR HPE UPS. 3 PHASE UPS from 60 to 300 kw

Similar documents
KEOR T. 3 PHASE UPS from 10 to 120 kva

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

TRIMOD HE UPS. MODULAR THREE-PHASE UPS from 10 to 80 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Keor MOD THREE-PHASE MODULAR UPS. up to 250 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL INFRASTRUCTURES

60 to 160 kva.

UPS. MODULAR from 10 to 60kVA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

UPS UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

MEGALINE UPS MODULAR SINGLE-PHASE from 1250 to VA

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

Galaxy VM. From 160 kva to 1000 kva, 160 kva or 200 kva modular approach. Three-phase power protection

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

DPA 250 S4 (50 kw 1,500 kw) The most energy-lean UPS on the market MODULAR THREE-PHASE UPS SYSTEMS. The most energy-lean UPS on the market

Galaxy VM. From 160 kva to 1000 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity. schneider-electric.

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

UPS. MEGALINE UPS MODULAR SINGLE-PHASE from 1250 to VA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

PowerValue 11/31 T kva

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

D Series: UPS UPTO - 300KVA - Three / Three Phase

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

TECHNICAL DATA SHEET KVA UPS Systemss

» Sophisticated» Reliable» Intelligent

Galaxy VM. From 160 kva to 1000 kva Three-phase power protection. apc.com/products

Features and benefits. Applications

Three-phase UPS system DPA UPScale ST kw The modular UPS designed for lowand medium-power applications

Technical Data Sheets

Technical Data Sheets

MGE TM Galaxy TM 7000

MKN-DSP SERIES - THREE PHASE

Technical Data Sheets

Technical Data Sheets

Onfiniti. 1 Phase UPS

MGE TM Galaxy TM 7000 GFC

DRX. MCCBs for residential and commercial SYSTEMS FOR ELECTRICAL INSTALLATIONS & INFORMATION NETWORKS.

Symmetra PX. Industry-leading efficiency, availability, and performance for small, medium, and large data centers and mission critical environments

Technical Data Sheets

3ph UPS NS3000 series kVA

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Liebert GXT-MT 1-3kVA UPS. Power Protection for Business Critical Continuity

Industrial PFC UPS System

Smart-UPS On-Line Lithium Ion UPS 230V. Single-phase, double conversion online UPS with Li-Ion batteries and advanced management features

Master Plus kva

Technical Data Sheets

PowerWave 33 Efficient power protection for today s IT and process-related work environments

HAIRF UPS. X5 Series KVA

Features and Benefits

On-line, Single Phase, Double Conversion UPS

magellan commercial UPS solutions Magellan Power Modular - Flexible UPS

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

01 RX3 2014_Cover-Front.pdf 1 6/24/ :08:02 PM

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

YOUR POWER IN SAFE HANDS. E Series UPS

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

Three-phase UPS system. DPA UPScale ST kw Best-in-class modular UPS for maximum availability

» Eco-Friendly. » Intelligent» Space Saving

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

POWER kva

Food power. ABB s rugged UPS PowerLine DPA ensures food and beverage production facilities keep running

Liebert NX TM. 250kVA kVA Transformer-free. High Efficiency, Scalable On-line UPS

POWER kva

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

TLE Series UPS 400/500 kw With eboost Technology

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

Technical data sheets

Master MPS kva kva 3:1 3:3 VFI TYPE

Series 120/120VAC Universal Tower/Rack Mount

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Master MPS kva kva 3:1 3:3 VFI TYPE

TLE Series UPS 160/200/225/250 kw with eboost Technology

Green Power 2.0 MASTERYS GP

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Motor Protection Circuit Breaker

Options & service. Additional 9355 options. Proven warranty and support services. Extensive service options for enhanced reliability.

Three Phase UPS Systems Range: 10 to 500kVA

PowerFlex 6000 Medium Voltage AC Drives

Technical Data Sheets

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Master Plus kva

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

Symmetra PX 96/160. Scalable from 16 kw to 160 kw Modular, scalable, high-efficiency power protection for data centers

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

Symmetra PX 250/500. Scalable from 100 kva kw to 500 kw, parallel capable up to 2,000 kw

Master MPS kva kva 3:1 3:3 VFI TYPE

Est ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA

Transcription:

KEOR HPE UPS 3 PHASE UPS from 60 to 300 kw

POWER PARTNER IN BUSINESS CONTINUITY 3 decades of experience in UPS industry Among top 3 UPS companies in India Installation base of >1million UPS systems* 254 service centers & 44 sales offices pan India 5 world class manufacturing units With an experience of over 3 decades in the UPS industry, Numeric has envisioned and relentlessly strived to offer reliable power quality solutions to its customers. Numeric is among the top 3 UPS Companies in India. With solutions from supporting a desktop PC to a large MW range mission critical power requirement, we have been serving thousands of satisfied customers across various market segments in India. Our customers include leading organizations from various market segments such as IT, Healthcare, Banking, Education & Research, Telecom, Industries, Government, etc. Our installation base, over the last decade, is more than 1 million active UPS s across market segments. With 5 world class manufacturing units located in Chennai and Sinnar, we are poised to meet the diversified needs of our customers. We provide 24/7 customer support through a wide and robust service and support system, which provides power continuity uptime and productivity to our customer s businesses. Our network of 254 service centers and 44 sales offices is the largest UPS service support network in India. More than 900 factory-trained service professionals are stationed in those locations to maintain UPS uptime. Numeric has been a part of the Legrand group since the 2012. Legrand, a global specialist in Electrical and Digital building infrastructure is a 5B organization operating across 180 countries. Today, Numeric provides complete solutions in UPS across Line Interactive, 1 Phase, 3 Phase and Modular UPS s. Global expertise and local knowledge make us a truly GLOCAL company. *over one decade. 2

KEOR HPE 300kW THE UPS WITH POWER UP TO www.numericups.com CONVENTIONAL UPS

KEOR HPE 3 PHASE UPS HIGH EFFICIENCY AND LOW TCO KEOR HPE is designed to reduce TCO. High efficiency double conversion, Transformer-free architecture and Internal battery option reduces commissioning costs and footprint. The technology conversion control dramatically reduces maintenance costs, extending all critical components and battery s life. 4

Power factor 1 Thanks to unity power factor design. The new KEOR HPE UPS guarantee maximum real power; 11% more than competitor products offering 0.9 power factor, fully 25% more than those of 0.8 power factor. Input phase auto correction UPS rectifier is designed to operate in mains even during the mains input phase reversal, avoid discharge of batteries, which increases life cycle of the batteries. Backfeed protection Backfeed energy detection circuit, as option for total upstream protection and operator safety. Internal battery 60 and 80 kw models can allow to obtain backup time up to 12 minutes. COMPACT SIZE AND ONE CABINET FOR 60 TO 160 kw CONFIGURATIONS www.numericups.com CONVENTIONAL UPS 5

KEOR HPE FRONT-ACCESS INSTALLATION AND MAINTENANCE The KEOR HPE UPS is designed to be installed and maintained completely from the front. All circuit breakers and communication ports are on UPS front side. A practical interior door allows you to reach even the parts installed on the bottom of the UPS, in order to have maximum access to all components. 6

Communication ports The communication ports are in the internal door and are available in the most common protocols: relay contact, ModBus-RTU by RS485, ModBus TCP/ IP SNMP by Ethernet. Internal front access All parts are accessible from the front, to speed up installation and maintenance. Cooling system The optimised cooling system, placed in the upper part of the UPS, enables to position the UPS against the wall without affecting performance. www.numericups.com WWW.UPS.LEGRAND.COM CONVENTIONAL UPS

KEOR HPE OPTIMIZED BATTERY MANAGEMENT Protecting capital expenditure on batteries, ensuring full availability of mission critical applications can only be achieved by keeping them in perfect condition. KEOR HPE comes with advanced charging and battery managing features, providing best battery performance and extended lifetime. 8

Intermittent charging With adjustable charging cycle to extend battery operating life and to achieve maximum energy savings. Easy access to the optional internal batteries Access to the battery is on the side, the trays can be extracted and inclined to facilitate the connection and substitution. Automatic setting of battery charging current with DCM function With feeding priority to output loads, ensuring low charging times for long autonomy applications. Battery charging voltage temperature compensation To prevent excess battery charging and overheating. Temperature sensor included in all units. Automatic and manual battery test To detect any battery performance deterioration. www.numericups.com CONVENTIONAL UPS 9

KEOR HPE INNOVATIVE OPERATING MODE 10

Set the best mode of operation for any application according to mains quality, load immunity grade to mains disturbances and system features, to always deliver the best reliable quality power at the highest efficiency. On-line double conversion VFI (Voltage Frequency Independent) double conversion total protection with up to 96% efficiency thanks to our Green Conversion patented technology. Smart ECO mode suitable for stable mains, in VFD (Voltage Frequency Dependent) mode of operation, achieving 98% efficiency. Cold Start Designed to start the UPS on battery mode when mains not available as an optional feature www.numericups.com CONVENTIONAL UPS 11

KEOR HPE 60-80-100-125-160-200-250-300 Conventional UPS - 3 Phase On-line double conversion VFI n KEOR HPE 60-80-100-125-160 Pack Cat.Nos. UPS (without batteries) Nominal power kva Weight (kg) Dimensions W x D x H (mm) 1 7206 701 60 kva 250 560 x 940 x 1800 1 7206 702 80 kva 300 560 x 940 x 1800 1 7206 703 100 kva 320 560 x 940 x 1800 1 7208 704 125 kva 360 560 x 940 x 1800 1 7208 705 160 kva 380 560 x 940 x 1800 1 7208 706 200 kva 720 850 x 900 x 1975 1 7208 707 250 kva 800 850 x 900 x 1975 1 7208 708 300 kva 900 850 x 900 x 1975 Empty battery cabinet for estimated backup time of appx 15 min Nominal power kva Dimensions W x D x H (mm) 2 7218 804 60 kva 770 x 450 x 1300 2 7218 805 80 kva 1150 x 370 x 1900 2 7218 806 100 kva 1150 x 425 x 1900 2 7218 806 125 kva 1150 x 425 x 1900 2 7218 807 160 kva 1180 x 460 x 1900 4 7218 806 200 kva 1150 x 425 x 1900 2 7218 809 250 kva 1375 x 575 x 1900 4 7218 808 300 kva 1340 x 470 x 1900 Empty battery cabinet for estimated backup time of appx 30 min Nominal power kva Dimensions W x D x H (mm) 2 7218 805 60 kva 1150 x 370 x 1900 2 7218 807 80 kva 1180 x 460 x 1900 2 7218 807 100 kva 1180 x 460 x 1900 2 7218 809 125 kva 1240 x 575 x 1900 4 7218 807 160 kva 1180 x 460 x 1900 5 7218 806 200 kva 1150 x 425 x 1900 4 7218 809 250 kva 1375 x 575 x 1900 4 7218 809 300 kva 1375 x 575 x 1900 Note: Battery disconnector will be external & not part of battery cabinet General Tolerance for dimension ± 2 mm Communication accessories Description 1 7218 631 CS 141 SK Professional (SNMP only) 1 7218 632 CS 141 B SK Standard (SNMP with sensor) 1 7218 633 CS 141 M SK Industrial (SNMP with MODBUS) Options Description Serial interface RS-485 ModBus Parallel card interface KIT Load-sync card interface kit Built-in Isolation transformer Wall mounted fused switch box Built - in battery for 60 & 80 kva - backup < 12 min n KEOR HPE 200-250-300 12

KEOR HPE 60-80-100-125-160-200-250-300 Conventional UPS - 3 Phase On-line double conversion VFI Characteristics General characteristics 60 80 100 125 160 200 250 300 Nominal power (kva) 60 80 100 125 160 200 250 300 Active power (kw) 60 80 100 125 160 200 250 300 Technology On-line double conversion VFI-SS-111 Waveform Sinusoidal Architecture Conventional UPS, parallelable up to 6 units Input characteristics Input voltage 380-400-415 V 3Ph+N Input frequency 50-60 Hz (45 65Hz) Input voltage range 400 V -20% / + 15% THD of input current < 3% Input power factor > 0.99 Output characteristics Output voltage 380, 400, 415 V 3Ph+N selected Efficiency up to 96% Output frequency (nominal) 50 /60 Hz C res t fac tor 3:1 THD of output voltage <1% (with linear load), <5% (with non-linear load) O utput voltage toleranc e ± 1% (with balance load) O verload c apac ity 10 minutes at 125%, 30 seconds at 150%, 0.1 seconds >150% Efficiency in Eco mode 98% Bypass Built-in Automatic and Maintenance By-pass Batteries Battery type VRLA - AGM Maintenance-free Lead Acid Batteries B attery tes t Automatic or manual Communication and management LCD Display Four LED s to show status at a glance. Four menu-driven interface buttons Touch Screen display Communication Ports Voltage free relay contacts, RS485 ModBus-RTU, Ethernet ModBus over IP or SNMP protocol (slot SNMP optional) Audible Alarm Acoustic alarms and warnings, configurable delays Emergency Power Off (EPO) Yes Remote Management Available Battery temperature probe Yes Physical characteristics Dimensions W x D x H (mm) 560 x 940 x 1800 850 x 900 x 1975 Net Weight (kg) 250 300 320 360 380 720 850 900 Ambient conditions Operating temperature ( C) 0 40 Relative humidity (%) < 95% not condensing Protection index IP20 Noise at 1 m (dba) < 60 < 65 Certifications Complies to EN 62040-1, EN 62040-2, EN 62040-3 R eferenc e produc t s tandards UE Note: As standard specifications are subject to change due to continuous development. Please check for confirmation in the publication General Tolerance for dimension ± 2 mm www.numericups.com CONVENTIONAL UPS 13

Customer services Reliable Excellent Tailor-made Directly present in 254 locations across India to ensure quick support, a team of 900 factory qualified engineers are available 24/7/365 to support your UPS system to ensure availability to the most critical loads. Numeric competitive edge lies in its ability to provide high valueadded UPS systems and service for customers. For Numeric, creating value means providing solutions with low energy consumption. The Legrand Group also provides all products required for electrical and digital building installations, particularly as an integrated system, with solution to fit customer needs. We offer a complete range of specific solutions and services to meet customer requirements: - Technical pre-sales support - UPS sizing and solution - Supervision of installation, testing and commissioning. - Operator training - Site audits - Warranty extension offers - Annual maintenance contract 14

SERVICES Support SITE INSPECTION, INSTALLATION SUPERVISION. We perform a comprehensive check of the UPS environment to ensure safety and fault-free operation. Our technical experts give manufacturer s recommendations to the site engineer or electrical contractors, and supervise the UPS installation before load power-up. SITE TEST, COMMISSIONING. Our Service Engineers conduct rigorous site tests and full setting-up of the UPS system before going live. They also configure the UPS according to your requirements. Commissioning operations for all UPS are carried out by qualified engineers to guarantee seamless start-up. After the final handing over of the UPS system, installation report is delivered to you. Training TRAINING We offer on-site training to ensure your equipment s safe and efficient operation. Troubleshooting courses are also available in our plants for intensive hands-on practice on UPS training equipment. Maintenance PREVENTIVE MAINTENANCE Electronic equipment and power systems, such as UPS, contain life-limited components and parts that must be replaced according to the manufacturer s specifications. To ensure optimal performance and to protect your critical application from potential downtime, it is crucial to perform preventive maintenance operations on a regular basis and replace parts when needed. Our Service Contracts with PM include cleaning, UPS measurements, functional tests, technical reports if required, battery health checkup and software upgrades. A Preventive Maintenance Plan is one of the most cost-effective actions that can preserve your initial investment and ensure your business continuity. CORRECTIVE MAINTENANCE, EMERGENCY CALL In the event of an Emergency Call, our engineers and spare-parts stocks strategically located as close as possible to your location, provide an intervention time with 24/7/365 assistance. After connecting a laptop to your UPS, a very powerful diagnostic software helps our engineer to identify the fault, thus ensuring short MTTR (Mean Time To Repair). Corrective actions are performed such as part replacement, adjustments to return the UPS system back to normal operation. www.numericups.com CONVENTIONAL UPS 15

Head Office 10 th Floor, Prestige Center Court, Office Block, Vijaya Forum Mall, 183, N.S.K Salai, Vadapalani, Chennai, Tamilnadu - 600 026. Phone: +91 44 4656 5555 Regional Offices Branch Offices Chandigarh SCO 4, First Floor, Sector 16, Panchkula, Chandigarh - 134 109. Phone : +91 93160 06215 New Delhi A 25, 1 st Floor, Mohan Co-Operative Industrial Estate, Mathura Road, New Delhi - 110 044. Phone : +91 11 26990028/29/30 Bhubaneswar N-2/72 Ground Floor, IRC Village, Nayapally, Bhubaneswar - 751 015. Phone: +91 674 255 0760 Kolkata Bhakta Tower, Plot No. KB22, 2 nd & 3 rd Floor, Salt Lake City, Sector - III, Kolkata - 700 098. Phone : +91 33 4021 3535/3536 Mumbai C/203, Corporate Avenue, Atul Projects, Near Mirador Hotel, Chakala, Andheri Ghatkopar Link Road, Andheri (East), Mumbai - 400 099. Phone : +91 22 3385 6201 Chennai 10 th Floor, Prestige Center Court, Office Block, Vijaya Forum Mall, 183, N.S.K Salai, Vadapalani, Chennai - 600 026. Phone : +91 44 3024 7236/200 Coimbatore No. B-15, Thirumalai Towers, No. 723, 4 th Floor, Avinashi Road, Coimbatore - 641 018. Phone : +91 422 420 4018 Hyderabad No. 205-208, 2 nd Floor, Block 2, White House Kundan Bag, Begumpet, Hyderabad - 500 016. Phone : +91 40 4567 1732 Bengaluru II Floor, AL-Latheef Building, 2/1, Union Street, Off: Infantry Road, Bengaluru 560 001. Phone : +91 80 2286 1081/78 Kochi Door No. 50/1107A9, JB Manjooran Estate, 3 rd Floor, Bye Pass Junction, Edappally, Kochi 682 024. Phone : +91 484 2801 921 Dehradun Plot No. 270, Ground Floor, Chaman Vihar, G.M.S. Road, Niranjanpur, Dehradun - 248 001. Phone : +91 135 272 9649 Lucknow 209/B, 2 nd Floor, Cyber Heights, Vibhuti Khand, Gomti Nagar, Lucknow - 226 018. Phone : +91 93352 01364 Jaipur Plot No. J-6, Scheme-12B, Sharma Colony, Bais Godown, Jaipur - 302 019. Phone : +91 141 221 9082 Guwahati House No 02, Rajgarh Girls High School Road (Behind Rajgarh Girls High School), Guwahati - 781 007. Phone : +91 361 245 0322/245 1987 Patna 204, Fraser Road, Hemplaza, 2 nd Floor, Patna - 800 001. Phone : +91 612 220 0657 Ranchi 202 & 203, Bardwan Compound, Lalpur, 2nd Floor, Ranchi - 834 001. Phone : +91 651 221 4071 Bhopal Plot No. 160, Devashish Complex, 2nd Floor, Zone-I, MP Nagar, Bhopal - 462 011. Phone : +91 755 276 4202 Nagpur Plot No.173, Ground Floor, Utkarsh Ashwini Appts, RPTS Road, Laxmi Nagar, Nagpur - 440 022. Phone : +91 712 228 6991/228 9668 Ahmedabad A-101/102, Mondeal Heights, Beside Hotel Novotel, Near Iscon Circle, S G Highway, Ahmedabad - 380 015. Phone : +91 79 6134 0555 Pune 302, 3 rd Floor, Swastik Chambers, Above ICICI Bank, Off Karve Road, Erandwane, Pune - 411 004. Phone : +91 84 5201 4036 Madurai Door. No.1, Pillayar Koil Street, S.S.Colony, Madurai - 625 016. Phone : +91 452 260 4555 NDM/MKT/CAT/3PH/07 JUN/18/-V2/0000 Sales - enquiry.numeric@numericups.com Service - support.numeric@numericups.com TOLL FREE NO : 1800 425 3266 www.numericups.com