Model 990 & 990V INSTALLATIONS AND OPERATING INSTRUCTIONS

Similar documents
Model 990DS INSTALLATIONS AND OPERATING INSTRUCTIONS

LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart

Installation, Operation, and Maintenance Manual Outdoor Glycol Feed System JWOP /055/100

IMPORTANT OPERATING CONDITIONS. Failure to comply with any of these conditions invalidates the warranty. STANDARD CONFIGURATIONS

PRODUCT: 1500 SERIES MOBILE EXPLOSION PROOF PAGE 1 REV "BLADE MASTER" AC-EP-SINGLE PHASE-1.5 HP OPERATING AND MAINTENANCE INSTRUCTIONS

07 Oil Change & Diesel Transfer Pumps

END SUCTION CENTRIFUGAL PUMPS

END SUCTION CENTRIFUGAL PUMPS

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS

07 Oil Change & Diesel Transfer Pumps

NECO Pumping Systems

Model &

Hydraulic Pump Troubleshooting P & BDP Series Models

Portable Filter Carts Models 5MF and 10MF

100 Gallon Skid Sprayer

Operating Manual for Rotary Gear Pumps CMI, S.A. (Mendaro, Guipuzkoa, Spain)

Pump Operating and Maintenance Manual - Models

HIGH VISCOSITY FILTER SYSTEMS

Operating and Installation Instructions

Operation and Maintenance. S100 Series Centrifugal Fire Pumps. Table of Contents. Visit us at F /22/02 6/21/18

Operating Instructions & Parts Manual

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery

Regenerative Turbine Pumps

Models

Self-Priming Close-Coupled Centrifugal Pumps In 316 Stainless Steel, Bronze and Cast Iron

Operating instructions Form no safety definitions

Tank Sealcoating Spray Systems

Installation & Operating Manual

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 10 Apparatus Service Tests Revised

30,000 lb. HEAVY DUTY PPF 195 POST PULLER

G E N E S I S S T O R M SPECIALIZED TOP OFF AND REPLENISHMENT MODULE

S200-P Series Centrifugal Fire Pumps Operation and Maintenance Instructions

Installation, Operation, Repair and Parts Manual

SHURflo Self-Priming Close-Coupled Centrifugal Pumps In 316 Stainless Steel, Bronze and Cast Iron

F PRO. 12 Volt Electric Sprayer. Part #AS76 Copyright 2014 by Hydro-Force Rev. 1/14

Low Profile J Series Power Unit with Vane Pump

Portable Filter Carts 10MFP with Moduflow

100 Gallon 4- Wheel Sprayer

8000 / 10,000 / 12,000

BSM ROTARY GEAR PUMPS

Voltmaster Centrifugal Trash Pumps

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

SHURflo Pedestal-Mount Centrifugal Pumps

MASTER COALESCER JR & PORTABLE MASTER COALESCER JR AIR PUMP MODEL INSTALLATION MANUAL

3" & 4" Cast Iron Self-Priming Centrifugal Pump Instruction Manual

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

SHURflo Close-Coupled Centrifugal Pumps

Operating Instructions & Parts Manual

Close-Coupled Centrifugal Pumps 316 Stainless Steel, Bronze and Cast Iron Models

Guardian Portable Filtration System

READ AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting

1600 PSI ELECTRIC PRESSURE WASHER

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

GROUP 3B CLEANER AIR SYSTEM CONTENTS

08 general Purpose Pumps

OWNER S MANUAL WARNING

100 Gallon Skid Sprayer

D-04/G-04 Maintenance

Portable Sealcoating Spray Systems

BOILER FEED SYSTEM OPERATION AND MAINTENANCE MANUAL

OWNER S MANUAL STOP. Models: Blade Master 1.5 HP 1500 Series Stationary Transfer Pump 1.5 Pump, Single Phase AC 110/220V, Non-Explosion proof

REPAIR SEALS AND OPTIONS

HL Series Centrifugal Fire Pumps Operation and Maintenance Instructions

Principals of Operation... 1 Rotary Vane Priming Pump VPE and VPES... 2 Rotary Vane Priming Pump VPO and VPOS Priming Valve...

General Purpose Pumps - Introduction

PROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS

#9040 FUEL TANK SWEEPER

Hydraulic PTO Flow Device

CIRRUS AIRPLANE MAINTENANCE MANUAL MODELS SR22 AND SR22T CHAPTER 28-00: FUEL GENERAL. Fuel 28-00: FUEL. 1. General

User and maintenance instructions. Fluid evacuator plus. Model MV7201. Date of issue November Form number Version 2

Installation Operation Maintenance ADDENDUM

P300 Metering Pump. Installation & Service P A WANNER ENGINEERING, INC.

Installation Operation and Maintenance Manual

PW-E1S 5,000 psi 5HP ELECTRIC POWER UNIT OPERATION MANUAL

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET

Bronze Plate-Mount Rotary Close-Coupled External Gear Pumps

Regenerative Turbine Pumps

GARDEN HOSE UTILITY PUMP

k. Components not properly adjusted. Refer to machine technical manual for proper adjustment of components.

Regenerative Turbine Pumps

OWNER`S MANUAL BLAZEMASTER. B & BM Series. Engine Drive Pumps for Fire Fighting & Water Transfer

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

Rancher Hydraulic Chute Owner s Manual.

DP3 Pump. 3:1, Air-operated, Oil. General. Operation. Technical Data. Installation R0 10/09. 35a 35b 35c

New & Improved VariFlo Plural Component Equipment. Low Pressure Polymer Dispensing Equipment

Troubleshooting WARNING

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

Water Treatment Plant Maintenance Considerations. Operation and Maintenance. Types of Maintenance 5/1/15

Ford Racing BOSS 302 Engine Oil Cooler (11-14 GT)

TABLE OF CONTENTS Service Information 2 Quick Start Instructions 4-5 Introduction 6 Specifications 6 Controls and Terminology

Installation, Operating and Maintenance Manual

1/2 HP SUMP PUMP OWNER'S MANUAL

GENERATOR MODEL NO: FG3000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0609

Wilfley. Model. Technical Handbook. Centrifugal Slurry Pump

TurboWerx Spartan-series TWX V Electric Scavenge Pump

Features and Benefits Wide Bottom: Translucent Bottle: 2 1/2 Gallon Bottle: Removable Bottle: Large cap: 15 Feet of Coiled Hose:

Fueltec Models 950AW & 955SS Mobile Fuel Tank Cleaning Systems

Pneumatic High-Viscosity Filtration System Instruction Manual

EQUALIZER SYSTEMS County Road 3 Elkhart, IN Fax

Transcription:

Model 990 & 990V Advanced Marine Technologies, Inc. 212 Yacht Club Drive Saint Augustine FL 32084 866-922-4804 904-829-1800 FAX 904-829-2800 pumps@x-change-r.com www.x-change-r.com INSTALLATIONS AND OPERATING INSTRUCTIONS

2 1.0 DESCRIPTION The Models 990 & 990V were designed specifically for larger diesel vessels with multiple engines. Particularly, the 990 & 990V were designed to service a vessel s two main diesel engines, each transmission or gear and one or two generators. However, the system is capable of servicing any combination up to eight engines. The oil flow from each main engine is controlled by a separate manifold valve which designates the flow from the engine, its transmission and a designated generator(s). 2.0 CONSTRUCTION The 990 & 990V are constructed with the highest quality materials selected for both wear and resistance and service life. The 990 & 990V utilize a heavy-duty reversible bronze body motor and rotary gear pump which has self-lubricating carbon bearings and drip-proof lip seals. Powered by a single phase, 1/3 HP 115V/60(Hz) or 230V/60(Hz) corrosion resistant motor which is overload protected, the pump is driven directly from the motor shaft by means of a flexible coupling. The motor is controlled by a three pole, double throw switch with FILL-OFF- DRAIN positions. Housed in an easy to clean enclosure allows direct access to the motor, pump and manifold system. 3.0 SPECIFICATIONS 990 Phase HP Voltage Width Height Depth Weight GPM 1 1/3 115V 14 12 7.5 27 lb. 4* 1 1/3 230V 14 12 7.5 27 lb. 4* 990V Phase HP Voltage Width Height Depth Weight GPM 1 1/3 114V 18 12 7.5 28 lb. 4* 1 1/3 230V 18 12 7.5 28 lb. 4* *Flow rates are approximate and may vary due to the temperature and/or viscosity of the oil. 4.0 LOCATION AND INSTALLATION This is a permanent system for mounting on a horizontal surface in the engine room. The system should be located in a readily accessible location to allow easy operation and service. The Models 990 & 990V have excellent priming characteristics and is capable of lifting liquids on the suction side as high as 15 feet. However, as a general rule, the suction lift should be kept as limited as possible by placing the system as central to all engine sources as possible. Installing the unit requires general knowledge of engine service and electrical wiring skills. If you are not familiar with these techniques, it is recommended an experienced marine mechanic be engaged to install the X-Change-R. The Models 990 & 990V are delivered with

3 the enclosure attached with access to the seven mounting holes on the backing plate. Secure the system to a flat surface through the mounting holes which accommodate ¼ X 20 mechanical screws. 5.0 ELECTRICAL WIRING REQUIREMENTS The Models 990 & 990V are designed for use with an 115V/60(Hz) or 230V/60(Hz) power source. The system is supplied with a 6 three conductor cord which allows for easy plug-in convenience to an engine room outlet. However, if preferred, the cord can be cut and hard wired to a panel breaker. When wiring the system, choose UL approved marine-grade wire and connectors. 6.0 INSTALLATION OF THE HOSES Because oil is a viscous fluid (particularly when cool) every attempt should be made to keep the length of the hose runs at a minimum. When changing engine oil or transmission oil, a small amount of waste oil will return to the system along with the fresh oil. This is acceptable for hose runs of 15 feet or less. Hose runs of 20 feet or more should be avoided, especially when connected to transmissions or small engines. Care should also be taken to avoid sharp bends in the hose and direct exposure to hot surface. When installing the hoses, design the layout symmetrically. It is easier to determine the location of the lines and presents a neat appearance. 6.1 Connecting Engine Oil Pan Hoses 1. Drain oil from each engine. 2. If the engines are not equipped with a factory installed oil pan drain hose, replace each oil pan drain plug with a drain hose assembly supplied by the engine manufacturer, or install a compatible fitting that will accommodate a ½ ID oil drain hose, an adapter may be required. 3. Connect properly measured lengths of approved ½ ID hose from each engine s oil pan drain to the appropriate manifold on the X-Change-R. 4. After completing the hose installation, carefully inspect the hose to insure 6.2 Connecting Transmission Hoses 1. Drain oil from each transmission. 2. If the transmissions are not equipped with a factory installed drain hose, replace each oil pan drain plug with a drain hose assembly supplied by the engine manufacturer, or install a compatible fitting that will accommodate a ½ ID oil drain hose. An adapter may be required.

4 3. Connect properly measured lengths of approved ½ ID hose from each transmission s oil pan drain to the appropriate manifold on the X-Change- R. 4. After completing the hose installation, carefully inspect the hose to insure 6.3 Connecting Generator Hose 1. Drain oil from each generator(s). 2. If the generator(s) is not equipped with a factory installed drain hose, replace the oil pan drain plug with a drain hose assembly supplied by the engine manufacturer, or install a compatible fitting that will accommodate a ½ ID oil drain hose, an adapter may be required. 3. Connect properly measured lengths of approved ½ ID hose from each engine s oil pan drain to the appropriate manifold on the X-Change-R. 4. After completing the hose installation, carefully inspect the hose to insure 6.4 Connecting Drain/Fill Clear Hose (Wand) 990 1. Connect the Drain/Fill Clear Hose (Wand) provided with your X-Change- R to the drain/fill outlet found on the left side of the unit. 6.5 Connecting Input / Output Valves 990V 1. Connect the Input / Output Valves to either New/Used Oil Reservoirs or Cockpit (external connection) and Engine Room access - the Drain/Fill Clear Hose (Wand). 2. If the Reservoirs are not equipped with a factory installed drain hose, replace the oil pan drain plug with a drain hose assembly supplied by the manufacturer, or install a compatible fitting that will accommodate a ½ ID oil drain hose, an adapter may be required. 3. Cockpit (external connection) is best connected to a quick disconnect and used for main oil change. Engine Room access is best used to top off. 4. Connect properly measured lengths of approved ½ ID hose from each connection to the appropriate manifold on the X-Change-R. 5. After completing the hose installation, carefully inspect the hose to insure 7.0 DRAINING USED OIL FROM THE ENGINES / TRANSMISSIONS / GENERATOR(S) To insure the oil maintains proper viscosity during the removal process, it is recommended the operator run the engines long enough to permit the engine block to become warm at least 140. Shut the engines down and allow ample time for the circulated oil to return to the oil pan.

5 7.1 Draining the Engine, Transmission or Generator 1. Warm engine to at least 140 F, then turn engine off. 2. Insert the PVC wand of the Drain/Fill hose into a container suitable for waste oil collection. (Remember, it is a legal requirement to dispose of waste oil in a responsible manner). 3. Loosen the oil filler cap on the engine or remove the dip stick to allow air to enter the crankcase. 4. Release the safe lock devise on the toggle switch. Do not turn. 5. Select the individual shut off valve handle of the engine, transmission or generator you wish to service. (SPECIAL NOTE: Open only one shut off valve at a time with other valves closed tight to prevent accidental draining of other engines.) 6. Flip the motor control switch to the DRAIN position. The pump will start immediately. You should hear a noticeable change in the sound (speed) of the pump motor when the used oil enters the pump. 7. Continue to operate the pump until there is a noticeable change in the sound (speed) of the pump motor, which is an indication air is being drawn into the crankcase oil hose and that the specified crankcase is now empty. Oil is drained at the rate of about a gallon each 15 seconds (4 gallons a minute). 8. Return the pump motor control switch to the OFF position when the crankcase is empty and shut the individual shut off valve handle. 9. When you have completed the service, be sure to cover the safe lock handle over the toggle switch. 8.0 FILLING THE ENGINES Before attempting to fill an engine, make certain the engine has been completely drained or is in need of a measured amount of additional oil. DO NOT OVER FILL! Next, determine the type and the amount of oil recommended by the manufacturer for each engine. Remember, FOUR QUARTS = ONE GALLON. There are two commonly used methods to determine when the proper amount of oil has been delivered to the engine. Pre-measured Method this method requires the operator to set aside a known quantity of oil prior to filling. For example, if the engine requires 22 quarts of oil, the operator may want to pump from a 5-gallon container, adding 2 additional, quarts as the container empties. Timed Method the timed method is used when pumping from a container of unknown capacity or a reservoir. The flow of the oil through the system varies primarily with the viscosity and temperature of the oil. Under normal conditions (75-85 ), the system pumps approximately 4 gallons per 60 seconds. Filling time is a function of several factors, including oil temperature and weight. 8.1 Filling the Engine

6 1. Insert the PVC wand of the Drain/Fill hose into a container of fresh oil. (Remember, it is a legal requirement to dispose of waste oil in a responsible manner.) 2. Loosen the oil filler cap on the engine or remove the dip stick to allow air to vacate the crankcase. 3. Release safe lock devise on the toggle switch. Do not turn. 4. Select the individual shut off valve handle of the engine, transmission or generator you wish to service. (SPECIAL NOTE: Open only one shut off valve at a time with other valves closed tight to prevent accidental filling of other engines.) 5. Flip the motor control switch to the FILL position. The pump will start immediately. You should hear a noticeable change in the sound (speed) of the pump motor when the oil enters the pump. 6. Continue to operate the pump until a measured amount of oil has been pumped into the engine s crankcase. Fresh oil is pumped at the rate of approximately 4* gallons per minute. If you do over fill an engine, you may simply flip the motor control switch to the DRAIN position for a few seconds to remove the overage. 7. Once filled, return the pump motor control switch to the OFF position when the crankcase is empty and shut the individual shut off valve handle. When you have completed the service, be sure to cover the safe lock handle over the toggle switch. 9.0 TROUBLESHOOTING SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTION No Liquid Delivery 1) Closed valves 1) Open valves 2) Plugged suction 2) Eliminate restriction 3) Air leak at suction 3) Locate and repair leak 4) Suction lift too high 4) Do not exceed vapor pressure of liquid 5) Motor wired incorrectly 5) Check wiring instructions Low Liquid Delivery 1) Pump shaft speed incorrect 1) Check driver speed 2) Discharge pressure too high 2) Reduce downstream pressure 3) Air leak at suction 3) Locate and repair leak 4) Worn or damaged pump 4) Inspect and repair as required 5) Low viscosity 5) Verify original application conditions Gradually Losses Prime 1) Suction lift too high 1) Improve suction pressure 2) Air or gas in fluid 2) Eliminate air or gas from fluid 3) Air leak at suction 3) Locate and repair leak 4) Worn or damaged pump 4) Inspect and repair as required Noisy 1) Cavitations 1) Improve system suction pressure 2) Solid particles in fluid 2) Install suction strainer 3) Air or gas in Fluid 3) Eliminate air or gas in fluid 4) Worn or damaged pump 4) Inspect and repair as required Motor Runs Hot or Overloads 1) Discharge pressure too high 1) Reduce downstream pressure

7 2) Shaft speed too fast 2) Reduce speed 3) Fluid viscosity higher than expected 3) Change to larger horsepower 4) Incorrectly wired motor 4) Check wiring instructions 5) Binding internal pump parts 5) Inspect and correct condition 6) Verify if actual amperage draw is within 6) Motors normally feel hot range Seal Leaks 1) Dry running 1) Open valves, prime pump 2) Solids in fluids 2) Add suction strainer 3) Seal material incompatible with fluid 3) Verify original application conditions 10.0 WIRING DIAGRAM