Variable Flow Rate Control Unit

Similar documents
RVP-R VAV REGULATORS. Intended use: VAV regulators are used for automatic airflow regulation in the ventilation and air conditioning systems.

VAV Terminal Units SDS

SYSTEM VAV-Controller. for Variable Volume Systems Type VBS

VAV controller. TROX Auranor Norge AS. Telephone Fax

Electrical data Nominal voltage AC 24 V Nominal voltage frequency

Type overview. R B2 en-gb subject to changes 1

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Ceiling swirl diffusers

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

VAV TERMINAL BOXES TYPE: BA BT

4/S6 VAV DAMPERS RVP-C, RVP-P, RVK RVP-C-T, RVP-P-T. v 2.5 (en)

Technical information

Variable Air Volume Dampers

BOX - Airflow management unit BOX. Airflow management unit. Solution. Options & Accessories

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

VAV/CAV BOXES COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

Power consuption Motor (Motion) Power consuption Standby (end position) 0(2)...10 VDC / Ri > 50 kω 0(4)...20 ma / Rext.= 500 Ω

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

Power consumption In operation At rest For wire sizing

volumetric flow controller Model VRA-Q Smart

Globe Valves. Technical Databook Version 1.2. Belimo Asia Pacific

VAV - A (High-speed variable volume flow ) Controls For Laboratories and Industrial Applications

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1 nominal torque 0.2 W 2 VA Auxiliary switch

HFB - Airflow Management Damper HFB. Airflow Management Damper. Product models and Accessories

RVP-R- VAV controller. In explosion-proof version

Technical Brochure. LTG Air Distribution. Variable flow rate controllers VRFactive. Rectangular, with LTG map control.

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch

Power consumption In operation At rest For wire sizing

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

Control units. Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL

NR series. Circular CAV air volume control terminals with system powered mechanical regulator

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing. Non-operating temperature

DN [ ] DN [ ] Functional data Media Cold and hot water, water with glycol up to max. 50% vol.

NV series. Induction VAV air volume control terminals

HFB - Airflow Management Damper. Halton HFB. Airflow Management Damper

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

7 Services Control and monitoring

Variable Air Volume (VAV) Pressure Independent Control

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

STR Circular VAV Terminal Units

Technical data sheet. Technical data. Safety notes

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Mixing Box MBE / MBP

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

kvs theor.: Theoretical kvs value for pressure drop calculation Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data. Safety notes

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

[ ] Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data. Safety notes

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

PN [ ] D7150NL/BAC D7200WL/BAC D7250WL/BAC D7300WL/BAC [ ]

AIR VOLUME TRANSMITTER / CONTROLLER IML

Power consumption Operation At rest Wire sizing. Auxiliary switch. EMC Low-voltage directive. Non-operating temperature range 40...

Overview of types. Characterised control valves, 3-way, with internal thread For closed cold and warm water systems

DCV-CF DCV-CF. DCV-CF Pressure control with airflow measuring CFL Version B03. Pressure controlwith airflow measuring. Product description

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Ventilation grilles for installation into walls, sills or rectangular

CAV controllers Type RN

Circular VAV and CAV air volume control terminals

DCV-LC DCV-LC. DCV-LC Lab climate control unit. Lab climate control SMART DAMPERS & MEASURING UNITS. Product description. Occupancy AIN AOUT DCV-LC

MANUAL INSTALLATION. Venturi FX. VFX Series. v100 Issue Date: 11/22/ Price Industries Limited. All rights reserved.

Ceiling swirl diffusers

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Round Duct System Model RR-Complete

Technical data. Safety notes

Ceiling swirl diffusers

Power consumption In operation At rest For wire sizing

Parts and characteristics

Power consumption In operation At rest For wire sizing. Non-operating temperature

Power consumption In operation At rest For wire sizing

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

ELECTRIC POWER REGULATION TEMPERATURE CONTROLLERS. room C

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS

Fan - Powered Terminal Unit Series Flow

Pressure control damper ERPA

DCV-RC DCV-RC. DCV-RC Room climate control unit. Room climate control SMART DAMPERS & MEASURING UNITS. Product description.

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

See «Overview of types»

WGA Long throw nozzle grille

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Power consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return

Regulation and shut-off damper SPB and SPC

Power consumption In operation At rest For wire sizing

Slot diffusers for ceiling installation

Commissioning manual. - Simplified VAV solution with full potential... Rev. Pascal-Comm RM-ver / RC-ver 1.

MOTORIZED VOLUME DAMPER

Butterfly Valves. Technical Databook Version 7.2. Belimo Asia Pacific

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Transcription:

VAV Produktdata TEKNISK DOKUMENTATION VENTILATION BG BURCHARTH A/S Variable Flow Rate Control Unit Model BVAV-R: VAV unit that has circular section. BVAV-RS: VAV terminal unit. BVAV-Q: VAV unit that has rectangular section. Material The casing and blades of circular section VAV units are manufactured from galvanized sheet, blade impermeability is from silicone gasket. The casing of rectangular section VAV units is manufactured from galvanized sheet, their blades are from extruded aluminium profile. Usage VAV terminal units include round entry neck and casing made of galvanized sheet, the inside of their casings consists of glasswool plates with thermal and sound insulation. VAV terminal units are designed for applications with variable flow rate at high velocities in one duct and can be used for both supply and return. These can be used for and duties of control, configuration and closing in air conditioning systems. VAV units are designed for accurate measurement and control air flow rate. In VAV applications, the air volume going into the room, is controlled depending on the cooling load. Therefore, energy consumption is reduced. Installation Circular section VAV units are installed with self tapping screw, rectangular section VAV units are with bolt-nut and VAV terminal boxes are with rod - nut. Accessory In VAV terminal units, water coil or duct type electrical heater can be added to the outlet of the box. VAV Unit Technical Details BVAV-R Model VAV Unit Standard Dimensions - Air Flow Rates Table

BVAV-RS Model VAV Unit Standard Dimensions - Air Flow Rates Table Vmin.(m3/h): Vnom.(m3/h): Vmax.(m3/h): u (m/s): ØD (mm): L (mm): Air flow rate when air velocity is 2 m/s Air flow rate when air velocity is 12 m/s Air flow rate that customer wants between Vmin. and Vnom. limit values Air velocity at VAV unit inlet VAV unit internal diameter VAV unit length BVAV-Q Model VAV Unit Standard Dimensions - Air Flow Rates Table Vmin.(m3/h): Vnom.(m3/h): Vmax.(m3/h): u (m/s): A 2 eff. (m ): Air flow rate when air velocity is 2 m/s Air flow rate when air velocity is 10 m/s Air flow rate that customer wants between Vmin. and Vnom. limit values Air velocity at VAV unit inlet Effective area

Motor BELIMO VAV-Compact MF TEKNISK DOKUMENTATION VENTILATION BG BURCHARTH A/S OEM customer specific VAV-Compact version consisting of a pressure sensor, digital VAV controller and damper positioning actuator for pressure independent VAV and CAV systems in comfort zone Control (0)2 10 V Service socket for operating devices LMV-D3-MF-F NMV-D3-MF-F Brief description Application Pressure measurement Actuator Control function VAV (VVS) variable volumetric flow The VAV-Compact has PI control characteristics and is used for pressure-independent control of VAV units in the comfort zone. The integrated D3 differential pressure sensor is also suitable for very small volumetric flows. The maintenance-free sensor technology enables versatile applications in the comfort zone: in residential construction, offices, hospitals, hotels, cruise ships, etc.. 2 different actuator variants (5 or 10 Nm) are available for different VAV unit structures. Volumetric flow (VAV-CAV) or Open-Loop (for integration in an external VAV control loop). Demand-dependant setting of volumetric flows min max on a modulating reference variable (0/2 10 V), e.g. room temperature / CO2 controller or DDC, for energy-saving air conditioning in individual rooms or zones. CAV (KVS) constant volumetric flow Step mode (via switching contact) for constant volume applications CLOSED / min / mid / max / OPEN. DCV Demand Controlled Ventilation Operating and service devices Electrical connection Sales, mounting and setting VAV-Compact MF versions are not compatible with Fan Optimiser! The integration in one DCV/Fan Optimiser system requires VAV-Compact versions with integrated Bus interface (MP, KNX, LON or MOD). See www.belimo.eu for more information. Service tool ZTH, PC-Tool service socket: locally pluggable or via PP connection. The connection is made with the integrated connection cable. VAV-Compact will be mounted by the VAV unit manufacturer (OEM), the application will be set and calibrated accordingly. The VAV-Compact is sold exclusively via the OEM channel for this reason. Type overview MF versions Both MF versions are specially manufactured customer versions of VAV-Compact (OEM version). They have no Bus interface and therefore are not compatible with Fan Optimiser. These versions are customised and labelled specifically for OEM on the sensors, damper spindles and fastening systems used. See documentation of the VAV unit manufacturer. Designation, e.g.: LMV-D3-MF-F ABC (ABC = Customer designation) Other versions The VAV-Compact is also available with a built-in interface for direct integration in MP-Bus systems, KNX, LONWORKS and Modbus. See www.belimo.eu for more information and documentation.

Volumetric flow compact control device for analogue versions Safety notes The device must not be used outside the specified field of application, especiallynot in aircraft or in any other airborne means of transport. Outdoor applications: possible only in the absence of direct effects on the actuator from (sea)water, snow, ice, sunlight and aggressive gases and when it is guaranteed that he ambient conditions do not deviate at any time from the limit values specified in the datasheet. Only authorised specialists may carry out installation. All applicable legal or institutional installation regulations must be complied with during installation. The device may only be opened at the manufacturer's site. It does not contain any parts that can be replaced or repaired by the user. Cables must not be removed from the device. When calculating the torque required, the specifications supplied by the damper manufacturers (cross-section, construction, place of installation), and the ventilation conditions must be observed. The device contains electrical and electronic components and is not allowed to be disposed of as household refuse. All locally valid regulations and requirements must be observed. Electrical installation See separate documentation for description of functions and applications

VAV variable operation Vmin Vmax Wiring diagrams Example 1: Example 2: VAV, analogue referenced signal VAV with shut-off (CLOSED), 2... 10V mode CAV step mode CLOSED / Vmin / V mid / Vmax / OPEN CAV control VAV-Compact can be adapted to the desired CAV function pattern for constant volumetric flow applications with PC- Tool by using the "CAV function": Damper CLOSED Vmin. Vmax damper OPEN (standard) Damper CLOSED Vmin Vmid Vmax damper OPEN (NMV-D2M compatible)

Control functions - VAV / CAV TEKNISK DOKUMENTATION VENTILATION BG BURCHARTH A/S VAV-operating volumetric flow Setting and control Damper CLOSED via 0... 10 V reference signal (Mode 2... 10 V) CAV operating volumetric flow - setting

Setting and Tool function TEKNISK DOKUMENTATION VENTILATION BG BURCHARTH A/S Explanations 1) Access only on operating level 2 2) Shut-off level 0.1 / 0.5V - Application: VAV mode, in Mode 2 10 V, Damper CLOSED via 0 10 V control signal. If the required switching threshold of 0.1 V cannot be attained, the threshold can be switched to 0.5 V. Note on CAV application: the shut-off level must not be set to 0.5 V. If the line 3 (Y) is open, damper will be CLOSED instead, min will be activated. 3) within the mechanical limit. 4) The first time the supply voltage is switched on, i.e. at the time of commissioning, the actuator carries out an adaption, which is when the operating range and position feedback adjust themselves to the mechanical setting range. The actuator then moves into the required position in order to ensure the volumetric flow defined by the positioning signal. 5) See www.belimo.eu for function and version history.

Display and operation TEKNISK DOKUMENTATION VENTILATION BG BURCHARTH A/S

Accessories Dimensions [mm] Dimensional drawings LMV-D3-MF-F Dimensional drawings NMV-D3-MF-F

VAV-Compact Model overview / feature comparison * on request