SAM S KIOSK & SET ASIDE USER MANUAL INSTALLATION & MAINTENANCE

Similar documents
Checker Unload Checkstand Installation Instructions

Record the serial number and date of purchase in your manual for future reference.

Instruction Manual For Baldor Buffers

Instruction Sheet. Subject: Installations Instructions. Air Compressor Kits. Importan

MN907 No. 285B Replaces 285A LB7012

Installing Power Components

PRODUCT MANUAL TILE CUTTING MACHINE. . Operation. Parts List and Diagram SPECIFICATIONS CAUTION:

LARGE CAPACITY INCUBATOR Installation, Operation and Maintenance Instructions

Carousel Unit User Manual Replacing the Check Stand Motor

Electric. PN April Series Electric Oven

Installation Instructions

Railway. assembly instructions. data and power solution. model# RAIL-LINEAR model# RAIL-90 model# RAIL-BULLPEN model# RAIL-3WAY model# RAIL-4WAY

Grind Pro Series. Operator Manual. Manufacture by:

STA-R Soiled Tray Accumulator Installation and Maintenance Manual

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

RU SERIES UPGRADE TempAssure Compatible

INSTALLATION INSTRUCTIONS

Auxiliary Status Switch Kit

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

INSTALLATION INSTRUCTIONS, PARTS LIST AND CONFIGURATION GUIDE FOR THE CARBONATOR. Large Model No

HP BladeSystem c7000 Carrier-Grade Options Installation Guide

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

Safety Message to Installers and Service Personnel of Emergency Vehicle Safety Equipment

Universal Lane. Installation and Maintenance Manual IMPORTANT PRODUCT LIABILITY INFORMATION

GE Monogram. Installation. Instructions. Professional Vent Hoods. 48" Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS. 36" Models ZV671WSS, ZV681YSS

Operating Manual Please Read Before Operating Unit

Vidir Machine, Inc. Shelving Carousel Owner s Manual SERVICE

Technical Manual. DLM Module. This manual should remain with the unit.

INSTALLATION INSTRUCTIONS

Installing the PBX04 Push Bumper on the 2015 Chevrolet Suburban/Tahoe

Mirror Solutions Bevel & Pivot Models Installation Instructions INSTALLATION INSTRUCTIONS. Figure 1

OVER THE RANGE MICROWAVE OVEN INSTALLATION INSTRUCTIONS

Monogram Series DUAL RATE CHARGER MHCH3V

CoolWave 2 Phase Control Board and Cable Replacement Kit

Dual-Lite Trident TRF 40 Wide Battery Cabinet 20-40kVA Systems USER MANUAL

MINI-EDGER POLISHER/SCRUBBER

OPERATOR S MANUAL BGC SERIES BENCH GRINDERS

INSTALLATION AND OPERATING INSTRUCTIONS

Installation Instructions

RollSeal 1733 County Road 68 Bremen, Alabama Part No Rev Owner s Manual RS-Divider Curtain

Alcatel-Lucent 7310 DC Metro Cell AWS (B4) Kit MC-DBR1, MC-DBR2, MC-DBR3, MC-DBR4, MC-DBR5. Installation Manual

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

QPET, QPETXU Battery Chargers

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

Owner's/Installation Manual

Operating Instructions

Assembly Instructions

Owner s Manual SMT PORTABLE SERIES IMPORTANT DOCUMENT - DO NOT DISCARD 600PE 1100PE 1100HC. SprayMasterTech.com. Date Manufactured: / / 600PE 1100PE

3M AEROSPACE & COMMERCIAL TRANSPORTATION DIVISION St. Paul, MN USA or or Made in USA

SAFETY, OPERATION & MAINTENANCE MANUAL

OBAE, OBAEXU, ON BOARD Battery Chargers

AIM LED LIGHT (wall mount)

Users Manual Certified Series Direct Drive Pump 1-7 LPM

OVER THE RANGE MICROWAVE OVEN/HOOD SYSTEM INSTALLATION INSTRUCTIONS

Instruction Manual For Baldor Tool Grinders

Installation and Service Manual

POWERWARE User s Guide VA.

INSTALLATION INSTRUCTIONS

Installation Guide Thermal Conductivity Detector Accessory 19232E

SAFETY, OPERATION & MAINTENANCE MANUAL

SAM Series 2-Wire and 3-Wire Clock

TABLE OF CONTENTS SPECIFICATIONS 3 INSTALLATION 4. Direct Mount 4. Ducted Installations 5. Installing Plenum 5. Machine Mount Stand 5.

Use and Care Guide. Part # UC SV-D Model # UC SV-d UC SV-d

CENTRAL VACUUM SYSTEMS

Record the serial number and date of purchase in your manual for future reference.

OPERATORS MANUAL for Electric Pressure Washers

Installing and Removing Power Supplies

INDEX 1. OVERVIEW DRAWING IMPORTANT SAFETY INSTRUCTIONS GROUNDING INSTRUCTIONS PRE-ASSEMBLY CHECK LIST ASSEMBLY STEPS...

INSTALLATION INSTRUCTIONS

OFFICE PARTITIONS. Data Port Openings. Use cable tie bracket to dress data cables under panels. STEP 1

Operating Instructions and Parts Manual AFS-1000B Air Filtration System

RP-4000 Reserve Power Control

Record the serial number and date of purchase in your manual for future reference.

Read carefully and follow all safety rules and operating instructions before first use of this product.

TOYOTA TACOMA Part Number: TTA-BGB16-DRL TTA-BGP16-DRL

Installing the PBX-PIT01 or PBX-PIT05 Pit Bar in the Ford Police Interceptor Utility

6, 8 and 10 variable speed Bench Grinders

INSTALLATIONINSTRUCTIONS FREESTANDINGELECTRICRANGE WITH DOUBLEOVENS

Installation Instructions

ASSEMBLY & SERVICE MANUAL

Electric Range installation manual

Installing the Switch Chassis

Lift Stik. Installation, Operation and Service Manual PLS PLS PLS PLS Model Number Serial # Date Placed in Service

REVERIE ADJUSTABLE BED OWNER S MANUAL. Reverie Deluxe Adjustable Bed. Copyright All Rights Reserved. Manual Part No.

Toggle Button Kit. Installation Instructions MK5 / MK6 Golf, MK5 Jetta

High Velocity Series Air Curtains

POLISHERS 17 & 20 DUAL SPEED OPERATING & MAINTENANCE

INSTALLATION INSTRUCTIONS FOR EGA AND EGH SERIES ELECTRIC HEATERS IN V OR H SERIES UNITS

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5

SOLO VACUUM OPERATING & MAINTENANCE

IMPORTANT SAFEGUARDS

Mobile Video Installation Guide

OWNER S MANUAL AFS-1500 Air Filtration

Effective June 1, 2013 This guide supersedes all previous versions

Installation Manual. HEPALERT LED LIGHT Kit Installation, Operation, and Maintenance Manual for the TLF Diffuser

OPERATOR'S MANUAL IMPORTANT SAFETY INSTRUCTIONS

Table of Contents. 4 Getting Started 4 About the Juice 5 Safety Terms 5 Product Registration 6 Important Notes 7 Truck Orientation

INSTALLATION INSTRUCTIONS

PRODUCT NUMBERING SYSTEM SERIES PHASE. 1: Single Phase 3: Three Phase

OPTEVA 378 ENHANCED CASH RECYCLER TERMINAL FRONT LOAD LOBBY UNIT PLAN VIEW FRONT VIEW SIDE VIEW

Transcription:

SAM S KIOSK & SET ASIDE USER MANUAL INSTALLATION & MAINTENANCE 033117

Table of Contents Required Tools:... 2 IMPORTANT SAFETY INSTRUCTIONS... 3 GROUNDING INSTRUCTIONS... 4 INSTALLATION INSTRUCTIONS... 5 PROVIDING POWER TO THE UNIT... 7 Electrical Parts List and Wiring Diagram... 8 SECURE THE UNIT IN PLACE... 9 ATTACH THE SIGN... 9 COMMON REPLACEMENT PARTS... 11 Required Tools: Phillips head screwdriver or drill with Phillips bit 3/31/2017 2

IMPORTANT SAFETY INSTRUCTIONS WARNING - To reduce the risk of electric shock, disconnect power before cleaning or servicing. CAUTION - Cables and wiring must be routed away from edges and other parts which may cause damage to cables and wiring. SAVE THESE INSTRUCTIONS 3

GROUNDING INSTRUCTIONS WARNING This unit must be grounded. In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This unit is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. DANGER Improper connection of the equipment-grounding conductor can result in a risk of electric shock. The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipmentgrounding conductor. If repair or replacement of the plug is necessary, do not connect the equipment-grounding conductor to a live terminal. Check with a qualified electrician or serviceman if the grounding instructions are not completely understood, or if in doubt as to whether the unit is properly grounded. Do not modify the plug provided with the unit if it will not fit the outlet, have a proper outlet installed by a qualified electrician. This unit is for use on a nominal 120 V circuit, and has a grounding plug that appears as shown below. GROUNDING PLUG This unit is factory-equipped with a specific electric cord and plug. No adapter should be used with this unit. If the unit must be reconnected for use on a different type of electric circuit, the reconnection should be made by qualified service personnel; and after the reconnection, the unit should comply with all local codes and ordinances. 4

INSTALLATION INSTRUCTIONS 1. Review packaging list against the order and the material received. Check all cartons for freight damage. Any which show damage must be noted on the bill of lading before signing. Request damage claim from freight carrier. If damage is concealed, save packing material and request an on-site carrier inspection and claim. 2. Set Kiosk in place. 3. Remove knock-out from the side of Kiosk to which the Set Aside will be attached. Insert the supplied rubber grommet into the knock-out opening. KIOSK KNOCK-OUT 5

4. Set Aside may be installed to either the right or left side of the Kiosk. Attach Set Aside to Kiosk unit using four (4) ¼-20 screws. The screws are preinstalled in the Kiosk. Remove the Set Aside s door panel. Remove the four screws from the Kiosk, align screw holes in Set Aside with holes in Kiosk. Reinstall screws through the Set Aside into the Kiosk. SET ASIDE WITH DOOR PANEL REMOVED SET ASIDE INSTALLED TO RIGHT SIDE OF KIOSK WITH DOOR PANEL IN PLACE 6

PROVIDING POWER TO THE UNIT 1. Attach the power pole to the unit through one of the two openings on the top deck of the Set Aside. A cover Plate and screws are provided to cover the unused opening. 2. Electrician required to make field wiring connection into field wiring boxes located in the Set Aside. See below and next page for electrical & wiring diagrams and parts list. CLEAN POWER, REQUIRES 15A, DEDICATED BRANCH CIRCUIT WITH ISOLATED GROUND. 7

Item # Electrical Parts List and Wiring Diagram Document Number Description Quantity 5 10030143 RCPT,DPX,ORN,125V,15A, IGRD 2 6 40-01523- COVR-ELEC-4X4 1 7 70027703 RCPT,SGL,15A,125V,ISO, TWLK,HUBBELL,IG4710 1 8 50016363 COVR,ELEC,2X4,1.40DIA 1 11 28843-00 Elect OTC Blank Box Cover 4in 1 12 70001500 LBL,PWR,CLN 1 13 42351-00 Label Circuit Iso Grd 1 14 70024356 LABEL-ISOLATED GROUND 1 15 70027355 JMPR,GREEN,14GA,STRD, 1RING 1 16 70022799 JMPR,15.5,BLK,14GA,SOLID 2 17 70024147 JMPR,GREEN,14GA,STRD, FORK-FORK 1 18 70024560 JMPR,GREEN,14GA,STRD, FORK-FORK, 15.5 LNG 2 19 70022800 JMPR,15.5,WHT,14GA,SOLID 2 20 70022795 JMPR,7.00,BLK,14GA,SOLID 1 21 70022796 JMPR,7.00,WHT,14GA,SOLID 1 22 40-00107- SCR,GND-R973,GRN,10-32 3/8 1 24 192269 NUT,WIRE,ORN,73B IDL 4 25 41631-00 CONN,STRT,3/8,CKSD 1 26 70028137 A,PNL,ELEC,SAMS,SET, ASIDE,GNEL 1 8

3. Route the Kiosk power cord through the knock-out and into the Set Aside cabinet. Connect to the 15A receptacle in the Set Aside. SECURE THE UNIT IN PLACE 1. Use the eight anchor bolts and washers provided to secure the unit to the floor. Install four bolts and washers to the base of both The Kiosk and Set Aside. ATTACH THE SIGN 1. Remove the four screws holding the cover plate in place and set the cover plate aside. Retain the four screws. COVER PLATE IS HELD IN PLACE WITH FOUR SCREWS. 9

2. Mount the sign to rear side of Kiosk via four screws (included) where indicated below. Install screws through the sign and into the corresponding holes in Kiosk. 3. Replace cover plate and secure using the four screws removed in Step 1. 10

COMMON REPLACEMENT PARTS Item Number Part Number Description Quantity 17 70027908 HARDWARE KIT 1 4 22015709 ANCHOR BOLT,.375-16 x 3.5, SS 8 3 195511-00 SCREW, ¼-20 x ½ 16 5 27035-00 SCREW, #10-24 x ½, ROLOK 16 2 70027863 KIT, SIGN, KIOSK 1 If you have any questions about the contents of this manual, please do not hesitate to contact us at 1-800-334-1766. Your dedicated Royston customer service team is ready to help you. 3/31/2017 11