HTX-HTH SEPARATORS I&O MANUAL

Similar documents
ejpx High Efficiency Liquid-Solid Separator ejpx Features and Benefits:

To ensure proper installation, digital pictures with contact information to before startup.

Check List for Optimal Filter Performance

Installation, Operation, and Maintenance Manual

EJECTORS GENERAL OPERATION & MAINTENANCE MANUAL

NECO Pumping Systems

Separator Systems Operations & Maintenance Manual

SST & PRO II Media Filtration Systems Installation and Operation Instructions

Centrifugal Separator Operations & Maintenance Manual

PLUNGER PUMP SERVICE MANUAL

Aquaflush. Z6000 Series Aquaflush Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual Z6000 Z6003

Installation and Operation Instruction Manual INSMAN-201. Industrial Multi Media Single Tank

1/2" AIR DRIVEN DIAPHRAGM PUMP

SUPPLEMENTAL MANUAL FOR THE INSTALLATION, OPERATION AND MAINTENANCE OF THE XL234 FILTER VESSEL

INSTRUCTIONS Installation - Operation - Inspection - Maintenance 4" - 16" ROSS MODEL - 30AWR FIGURE 29 SINGLE ACTING ALTITUDE VALVE

Flow Control & Pressure Reducing Valve with Hydraulic Control (Sizes 3''- 12"; DN80-DN300)

PRO II & SST Media Filtration Systems Installation and Operation Manual

HARMSCO Hurricane Swing Bolt Water Filters Models: HUR 1X170FL, HUR 3X170FL HUR 5X170FL, & HUR 8X170FL

Tekleen LPF USERS AUTOMATIC FILTERS, INC. MANUAL

20 Series. Simplify your pumping needs. s Adhesive Supply Servo Pump:

PLUNGER PUMP SERVICE MANUAL

HEAVY DUTY FLAP VALVE PUMPS For Fluids Containing up to Line Size Solids

Crispin Valves Operating Guide. Crispin

SERIES PC INSTRUCTION AND OPERATION MANUAL

Series 867 Reduced Pressure Zone Assemblies

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET

MODEL 200 MULTI-JET FLOW METER

3. Fuel System FUEL SYSTEM FUEL INJECTION (FUEL SYSTEM) A: GENERAL. FU(STi)-7

MODEL 200 MULTI-JET FLOW METER

Warning and Safety Precautions

INSTRUCTION MANUAL INSTALLATION OPERATION TROUBLESHOOTING MAINTENANCE PRESSURE RELIEF VALVE WITH SURGE ANTICIPATION (HYDRAULIC) FEATURE MODEL 50RWR-A

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

TECHNICAL DATA. Q= C v P S

ROOTS Meters Series B3 Meter Models 8C175-56M175

Model 8329 Table of Contents

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

SAFETY MANUAL READ FIRST!

Model Table of Contents. SERVICE & OPERATING MANUAL Original Instructions. Instructions Sheet:

Manual for all Rittenhouse Skid Mount & Trailer Sprayers

Wet pipe low flow foam/water manifold system

Dosage Pumps - Installation Guide

Table of Contents Illustrations

WARCO CHEMAG SERIES GH FILTERS

MODEL 900 IMPELLER-TYPE FLOW METER

Thompson Strainer MLS-2

Spin Klin 12" Super Flow

BOSS 107 SEPARATOR SYSTEM INSTALLATION & APPLICATION MANUAL

Flow Control Valve IOM 770-U

AIRMIX PUMP and LOW-PRESSURE PUMP air motor with reversing block

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS

50-01 (Full Internal Port) (Reduced Internal Port) Pressure Relief. & Pressure Sustaining Valve MODEL

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

PRESSURE RELIEF VALVE

APP pump instruction APP and APP 16-22

WARNING CAUTION. CAUTION Do not exceed 120 psig (8.3 bar) air-inlet pressure.

ONYX VALVE CO MODEL DAC-PFO Installation & Maintenance

SEPARATOR PURGE KIT OPERATION & MAINTENANCE MANUAL

Installation, Operation & Service Manual. PPL Bag Filter Housings. Table of Contents Page No. Eaton Filtration, LLC

Automated Fuel Maintenance Systems (FPS)

Operator's Manual. Models (¾") (1") (1½ ) (2 ) (3") (4") (6") (8")

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

OPERATION AND PARTS MANUAL

Penn Valley Pump Company Design Information for Double Disc Pumps

ARKAL FILTERS CATALOGUE

VAF TM FILTRATION SYSTEMS HYDROCYCLONE SEPARATOR

APP pump instruction APP 21-43

Instructions for Installation, Operation, Care and Maintenance

Technical Data TYPE T124 & T134 TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4512A

WARNING Carefully Read These Instructions Before Use

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM)

HYDRAULICS. TX420 & & lower. Hydraulic Tandem Pump Removal. 4. Remove the LH side panel (Fig. 0388).

Owner's Manual. Model: SK-61-4R ( ) (60 Gallon Skid Sprayer w/2.5 H.P. Engine, 4-Roller Pump, Deluxe Handgun) Technical Specifications

Mudhen Portable Slurry System Owners Manual

Colt Series C400, C500

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

Installation, Maintenance, & Repair Series 995 Reduced Pressure Zone Backflow Preventers

ONYX VALVE CO MODEL CAR, CAP-PFO Installation & Maintenance

LAKOS AUTOMATIC SELF-CLEANING SCREEN FILTERS

WORKHORSE. Assembly / Operation Instructions / Parts

RAIN BIRD - AQUAGATOR AQUAGATOR INSTALLATION & TROUBLESHOOTING MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR Engine Mounted Radiators with Extended. Shafts

MASTER COALESCER JR & PORTABLE MASTER COALESCER JR AIR PUMP MODEL INSTALLATION MANUAL

LIQUID MEASUREMENT STATION DESIGN Class No

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)

Phone (toll-free): (888) Phone (local): (973) Fax: (973) Web:

BERMAD Waterworks. Pressure Relief/Sustaining Valve. Model: WW Series. Features and Benefits. Major Additional Features

LG-60-3PT-WP-309-BL-TSC

Series 105 Simplex Strainer Cast Iron Swing Bolt O-Ring Closure, Flanged Connection Class 125 ANSI Flat Face Flange Rating VENT 'A' FLOW

SC Swing Check Valves Product Data Sheet. Valve Availability. Body Material: Size Range: 3" through 8" Pressure: 100 psi (3") 70 psi (4" to 8")

TURBOCHARGER Toyota Celica DESCRIPTION OPERATION TURBOCHARGING SYSTEMS All Models

PV4 - Compact Shut Off Style Pig Valve IOM - Installation, Operation & Maintenance

ANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

TotalPac 3 Firecyle III Wet pipe Remote controlled system

The electric motors are designed for driving equipment that requires continuous operation, and their high efficiency reduces energy consumption.

DUST COLLECTOR (BOTTOM REMOVAL BAG & CAGE) INSTALLATION AND OPERATING INSTRUCTIONS

TotalPac 3 Deluge system Pneumatic release

TECHNICAL DATA. model f-1 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA. Page 1 of 11

DELUGE VALVE DATA SHEET

SWIMMING POOL SOLAR HEATING SYSTEMS INSTALLATION MANUAL FOR AQUASOL SOLAR COLLECTORS

Aquaflush. Z6100 Series Aquaflush Concealed Flushometer Installation, Operation, Maintenance, and Parts Manual Z6140

Transcription:

INSTALLATION OPERATIONS AND MAINTENANCE HTX-HTH SEPARATORS I&O MANUAL 1365 N. Clovis Avenue Fresno, California 93727 (559) 255-1601 www.lakos.com LS-714B (Rev. 11/17)

TABLE OF CONTENTS Table of Contents... Page 2 Principle of Operation... Page 3 Operation/Installation... Page 3-4 Recommended Piping... Page 4 Maintenance Purging... Page 5 Maintenance Recommendations... Page 6 Trouble-Shooting... Page 7-9 HTH Flow vs Pressure Loss Chart... Page 10 HTX Flow vs Pressure Loss Chart... Page 10 Spare Parts... Page 11-16 Notes... Page 17 2

Principle of Operation LAKOS Separators are designed specifically to remove solids from liquids. Each model is calculated for use within a prescribed flow range for maximum performance and solids removal. Flow rates above and below the recommended range may affect such performance. Upon tangential entry, the liquid/solids are drawn through internal tangential slots and accelerated into the separation chamber where solids heavier than the carrying liquid are centrifugally separated and allowed to accumulate in the unit s collection chamber for eventual purging (see Page 5). The liquid (free of separable solids) is then drawn to the vortex and up through the separator s outlet. Installation Instructions 1. LAKOS Separators are shipped on skids or in wooden crates. Support legs (22 ½ low profiles only) are detached. Lifting Lugs, located on the unit s side and/or flanges, are provided for hoisting as necessary. 2. A suitable foundation is necessary to accommodate the LAKOS Separator s weight including liquid. Anchor bolts are recommended in the base of the legs (low profile) or skirt (vertical profile). 3. Prior to installation, inspect the inlet/outlet/purge connections for foreign objects incurred during shipping/storage. 4. Inlet/outlet pipe connections to the LAKOS Separator should be a straight run of at least five pipe diameters to minimize turbulence and enhance performance. 5. Proper purge hardware and/or solids-handling equipment is required to flush separated solids from the separator. 6. All LAKOS Separators operate within a prescribed flow range (Pipe size is not a factor in model selection). Use appropriate hardware to match the inlet/outlet size. 3

Installation Instructions (continued) Grooved couplings are not included with the separator. Optional flanged connections are available upon request. 7. Inlet pressure to the LAKOS Separator must be at least equal to or greater than the anticipated pressure loss through the separator plus 15 psi (1 bar) plus whatever downstream pressure is required. 8. Pressure gauges are required at both the inlet and outlet of the separator in order to monitor pressure loss and proper flow. If separator operates with an open discharge, a valve should be installed to create a back pressure of at least 5 psi (0.3 bar). 9. Winterizing is important if the LAKOS Separator is to remain idle in freezing temperatures. Drain liquid as necessary to avoid expansion of water to ice and related damage. Recommended Inlet and Outlet Piping 4 Grooved couplings are not included with the separator. Optional flanged connections are available upon request. 7. Inlet pressure to the LAKOS Separator must be at least equal to or greater than the anticipated pressure loss through the separator plus 15 psi (1 bar) plus whatever downstream pressure is required. 8. Pressure gauges are required at both the inlet and outlet of the separator in order to monitor pressure loss and proper flow. If separator operates with an open discharge, a valve should be installed to create a back pressure of at least 5 psi (0.3 bar). 9. Winterizing is important if the LAKOS Separator is to remain idle in freezing temperatures. Drain liquid as necessary to avoid expansion of water to ice and related damage.

Maintenance/Purging 1. LAKOS Separators must be purged regularly. Otherwise, the accumulation of separated solids will overfill the separator s collection chamber, substantially affecting performance and causing undo wear. 2. Several purging options are available and all may be performed while the LAKOS Separator is in full operation. a. Manual: A full-port, straight-through valve may be installed on the standard purge opening and actuated manually as necessary to purge separated solids. b. Automatic: The use of LAKOS Separators in a given application typically implies the need for heavy or unusual solids removal. A LAKOS Auto-Purge System is therefore recommended. Consult your LAKOS representative for details on motorized ball valves and other systems. c. Semi-Automatic: The use of LAKOS Separators in a given application typically implies the need for heavy or unusual solids removal. A LAKOS Solids Recovery Vessel System is therefore recommended. The SRV-816 allows for continuous purging of the solids collected into a separate collection bag. Once the bag is full with solids, the bag is emptied. The bag can be cleaned and reused, or simply replaced. Consult your LAKOS representative for details on the solids recovery vessel and accessories. 3. HTX/HTH Separators feature standard purge outlets. Prior to start-up, the installation of a manual valve on the purge is recommended so that this outlet may be serviceable at any time for either supplemental purging or as a stand-by, should the primary purge line ever require servicing. 4. Important: All purge hardware should be installed prior to any elbows or turns in the purge piping. Avoid uphill purging, which can clog piping and hinder effective solids evacuation. 5. To determine the necessary frequency, purge often at first and calculate the proper rate with regard to the actual volume of separated solids. Purge duration should be long enough to evacuate the purge chamber of solids. Frequency of purge should not exceed the time it takes to over fill the collection chamber. Consult your LAKOS representative for specific recommendations regarding your application. 6. When operating in sub-freezing temperatures, be sure to protect the separator s collection chamber and all purge line piping from freezing. 5

Maintenance Recommendations LAKOS recommends periodic inspections of the separator to keep performance at an optimum level. Full Faced Flange Gasket or Victaulic Gaskets should be checked for leaks and replaced as necessary. Gasket should be replaced at disassembly of separator. Main Barrel Seal should be replaced when disassembly of separator is required. Hand Hole Clean-out. Hand Hole should be removed to inspect the collection chamber for unwanted build up. Inspection should be conducted monthly or when shutdown is convenient for access. Hand Hole Gasket, inspected for leaks and change as necessary. Separator Slots should be inspected during facility pipe inspection is required. Inspection of slots is recommended when separator performance is suspect. Slots should be checked for obstruction and wear. Note: Visual inspection of the separator should be conducted once a month. Visual inspection should also include observing the inlet and outlet gauges on the separator. This inspection will indicate the pressure drop across the separator. The pressure drop and actual flow rate can be compared to the product brochure to determine if the separator is operating within its expected performance range. Automatic purge or manual purge should be checked for leaks and operation. Purge valve seats or diaphragms should be changed as necessary. 6

Trouble-Shooting Guidelines For Separator Installation 1. Verify Actual Flow Rate: Use pressure gauges to indicate differential pressure and flow meter to verify flow rate. (Multiple pumps used to increase flow are installed in parallel (into common manifold); multiple pumps to increase pressure are installed in series (one after another). Flow meters should be installed prior to the separator. Flow meters installed after the separator will indicate erroneous data. 2. Plumbing Two Separators: Do not plumb two separators from two independent pumps into the same outlet header without installing balancing valves on the discharge of each separator. The balancing valves must be set to achieve a pressure loss across each separator that indicates a flow rate (according to that model s published flow chart) equal to the flow rate anticipated through the pump that feeds each separator. 3. Verify Actual Inlet Pressure: Actual inlet pressure must be at least 15 psi (1.03 Bar). A minimum back pressure of 5 psi (.34 Bar) must be created at the separator discharge. This may be accomplished via process equipment, piping, or a valve. Unrestricted open discharge to a pit, sump, etc., will result in unacceptable performance. Be sure that no source of vacuum/suction exists in the piping arrangement. If vacuum/suction exist (i.e. downward piping after the separator, pump suction installation, booster pump etc.), put a valve between the separator and the suction source and pressure gauges on either side of the valve. Throttle the flow until the pressure loss across the separator indicates the published flow rate which most closely resembles the anticipated flow rate through the separator. 4. Vibration: Check installation piping inlet & outlet configurations (see appropriate product sheets for model of separator installed). Mild vibration is possible in some installations and should be considered normal. Excessive vibration is typically due to entrained air (use air vents), improper piping (follow the installation instructions) or system vibration (amplified at the separator). 7

Trouble-Shooting Guidelines For Separator Installation (continued) Units should be secured properly to the floor or wall. If separator is hung, stabilizers may need to be added. The foundation must be sturdy enough to support the weight of the product (expected wet weight can be obtained from the product literature). The use of expansion joints is advisable with all separator installations. It is particularly recommended that these devices be employed when piping arrangements cannot comply with the configurations suggested by LAKOS product literature. 5. Vertical Units: Be aware that solids may accumulate within the separator for a period of time until the solids reach the level of the purge outlet. The purge outlet is not flush with the bottom of the solids collection chamber. 6. Purging: Avoid uphill piping. Purge-piping size is recommended by factory. Be sure that purging is maintained for the proper duration (proper duration is the time it takes fluid to come out clean ) in order to pass all accumulated solids through the full length of the purge piping. Continuous purge (bleed) piping must be sized properly. Oversized piping will allow purged solids to settle in the line and result in plugging. Under sized piping will unduly restrict the flow and will result in plugging. Purge flow must not exceed 10% of the inlet flow. If this occurs, separator efficiencies will be severely reduced. If the accumulation of solids in the separator s collection chamber becomes clogged or compacted, it may be necessary to shutdown or bypass the separator and gain internal access to clear the debris. Never purge the separator into the fluid source from which the separator is being fed unless the actual solids are being contained by an appropriate solids collection technique. Do not connect two or more separators to one Closed Recovery System unless the separators are supplied by the same pump and the separators are of the same model and size. 7. Super-Separators: Two-stage separators (i.e. Super Separator) must be purged separately do not join purges together. 8

Trouble-Shooting Guidelines For Separator Installation (continued) 8. Installation: Proper installation should always include an isolation valve between the separator purge outlet and any purge system. This will allow for the easy removal of the purge system for servicing without having to shut down the entire system. Separators which feature a removable upper chamber should be installed with a spool in order to facilitate the removal of the upper chamber (see diagram on the appropriate product sheet). 9. Flanges/Couplings: All flanges and/or grooved couplings should have the appropriate gasket/seal in order to ensure a leak-free installation. All hand-hole clean-out ports and other internal access devices should also be properly re-sealed after use. 10. Air Relief Ports: The appropriate air relief ports should be used at start-up to expel air from the separator. If the separator will be drained periodically or exposed to entrained air or gases from the piping system, air vents should be permanently installed. 11. Down Stream Filtration: The use of finer filtration (polishing) downstream from the separator is a common application. Be aware, however, that the barrier filter (as it accumulates more solids) causes an increasing pressure loss, which may cause the flow rate of the system to be reduced sometimes below the recommended flow rate of the separator. This situation will often reveal itself when typical separable solids begin to show up regularly on the downstream barrier filter (leading the customer to possibly believe that the separator does not work). Always check for variations in the flow rate when down stream conditions change. 9

HTH Flow vs Pressure Loss Chart Flow Rate (m 3 /hr) A HTH-0285 50 75 100 150 350 500 1,0002,000 B C HTH-0450 HTH-0500 D HTH-0810 15 12 10 1.0.8.6 E F G H HTH-1275 HTH-1950 HTH-3500 HTH-6700 5 A B C D E F G H.4 4 Pressure Loss (psi) 3 2.2 Pressure Loss (bar) 2003 00 400 1,000 2,000 5,000 10,000 Flow Rate (U.S. gpm) HTX Flow vs Pressure Loss Chart Pressure Loss (psi) 12 10 5 3 Flow Rate (m 3 /hr) 3 5 20 A 7 30 9 10 B Flow Rate (U.S. gpm) 40 50 C 15 20 25 D 100 E 50 F 200 75 100 G H 300 500 150 200 250 I J 1,000 K 500 750 1,000 1,500 L M N 2,000 3,000 5,000 2,000 2,500 10,000 O 3,000 1.0.8.6.4.2 Pressure Loss (bar) A B C D E F G H I J K L M N O HTX-0016 HTX-0028 HTX-0038 HTX-0060 HTX-0085 HTX-0130 HTX-0200 HTX-0285 HTX-0450 HTX-0500 HTX-0810 HTX-1275 HTX-1950 HTX-3500 HTX-6700 10

HTX-HTH Spare Parts List (*) indicates HTH parts list HTX-0004 118504 GROMMET STRIP 15/16 x 1/4 EPDM / 6 LG 106140 GASKET COUPLING 3 TYPE E GROOVE EPDM HTX-0010 118504 GROMMET STRIP 15/16 x 1/4 EPDM / 7 3/8 LG 106141 GASKET COUPLING 4 TYPE E GROOVE EPDM HTX-0028 118504 GROMMET STRIP 15/16 x 1/4 EPDM / 11 LG 116443 GASKET COUPLING 5 TYPE E GROOVE EPDM 11

HTX-HTH Spare Parts List (*) indicates HTH parts list HTX-0038 118504 GROMMET STRIP 15/16 x 1/4 EPDM / 11 7/8 LG 106142 GASKET COUPLING 6 TYPE E GROOVE EPDM HTX-0060 118504 GROMMET STRIP 15/16 x 1/4 EPDM / 16 11/16 LG 106147 GASKET COUPLING 8 TYPE E GROOVE EPDM HTX-0085 118504 GROMMET STRIP 15/16 x 1/4 EPDM / 19 15/16 LG 106147 GASKET COUPLING 8 TYPE E GROOVE EPDM 12

HTX-HTH Spare Parts List (*) indicates HTH parts list HTX-0130 118504 GROMMET STRIP 15/16 x 1/4 EPDM / 20 LG 106140 GASKET COUPLING 8 TYPE E GROOVE EPDM HTX-0200 118504 GROMMET STRIP 15/16 x 1/4 EPDM / 26 5/16 LG 106149 GASKET COUPLING 10 TYPE E GROOVE EPDM HTX-0285 118504 GROMMET STRIP 15/16 x 1/4 EPDM / 27 1/16 LG 106150 GASKET COUPLING 12 TYPE E GROOVE EPDM *118512 GKT 13

HTX-HTH Spare Parts List (*) indicates HTH parts list HTX-0450 118504 GROMMET STRIP 15/16 x 1/4 EPDM / 33 3/8 LG 116634 GASKET COUPLING 14 TYPE E GROOVE EPDM HTX-0500 HTX-0810 14 118504 GROMMET STRIP 15/16 x 1/4 EPDM / 33 3/8 LG 116634 GASKET COUPLING 14 TYPE E GROOVE EPDM 118504 GROMMET STRIP 15/16 x 1/4 EPDM / 50 1/4 LG 119488 GASKET COUPLING 20 TYPE E GROOVE EPDM

HTX-HTH Spare Parts List (*) indicates HTH parts list HTX-1275 118504 GROMMET STRIP 15/16 x 1/4 EPDM / 55 3/4 LG 121285 GASKET COUPLING 24 TYPE E GROOVE EPDM HTX-1950 HTX-0810 118504 GROMMET STRIP 15/16 x 1/4 EPDM / 33 3/8 LG 116634 GASKET COUPLING 14 TYPE E GROOVE EPDM 119685 GASKET ANSI 12 HTX 28 150# 1/8 THK NEOPRENE 15

HTX-HTH Spare Parts List (*) indicates HTH parts list HTX-3500 119702 GASKET ANSI 16 HTX 36 150# 1/8 THK NEOPRENE HTX-0500 120437 GASKET ANSI 20 HTX 42 150# 1/8 THK NEOPRENE 16

NOTES: Separator Model: Sales Order #: Purchase Date: Distributor: System Flow: Separator Delta P: 1365 N. Clovis Avenue Fresno, California 93727 (559) 255-1601 www.lakos.com 17