General_technical_data Series

Similar documents
General_technical_data Series

General_technical_data Series

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

Indicator body round for raised full face, black plastic, 22.5 mm mounting. Part No For complete switch also order

Indicator body single with two independent lamp bases, raised, rectangular, black plastic, screw terminals, without bezel. Part No

General_technical_data Series

Switches- and Indicators

HMI Components. Series. Indicator Illuminated pushbutton Mushroom-head pushbutton Key lock switch

HMI Components. Series. Indicator Pushbutton Illuminated pushbutton Buzzer. Machinery and Automation Panel building. Raised design PCB (with adaptor)

Functions The Series 19 incorporates the following functions: Indicator Pushbutton Illuminated pushbutton

HMI Components. Series. Indicator Pushbutton Illuminated pushbutton. Machinery and Automation Panel building. Raised design

General_technical_data Series

Switches- and Indicators

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

FOOT SWITCHES

FL series position switches

Contacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Wire size

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

Contacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Low energy contacts gold plated. Minimum PUSHBUTTON

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC mm

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66

LK Position Switches TECHNICAL DATASHEET.

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

MS General Information Extended Product Type: MS

Safety switches for hinges

XB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS

Limit Switches - Limit Type (PS21L) Metal Body IP66

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

Prewired position switches FF series

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Safety rope switches with reset for emergency stop

Pushbutton switches & indicators. Panel Sealed to IP65. Push on tab terminals 6A 250VAC AGENCY APPROVALS

0190 / Tolerance in psi (bar) at room temperature. Adjustment range in psi (bar) psi. ± 2.90 psi. (± 0.2 bar) (0.3-1.

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

Model Number Structure

Microswitches M series

Pushbutton switches & indicators. Panel Sealed to IP65. Push on tab terminals 6A 250VAC AGENCY APPROVALS

PRODUCT SPECIFICATION. Foot Switches. Series.

1/4 BSPP. 500 psi / 35 bar) psi / 35 bar) 8 018X XXX 03 X XXX

Metal limit switches are made of zinc alloy and have a degree of protection of IP67 and NEMA Type 4, 4X.

Safety Limit Switch

XACA871 pendant control station XAC-A - 8 pushbuttons

Oiltight Switches & Pilot Devices

Safety switches with separate actuator

Pilot devices. General construction

Standard Interlock Safety Switches

Position switches FD series

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

Switches with manual reset

Safety rope switch with reset for emergency stop

Safety switches with separate actuator

A02 SERIES PUSHBUTTON SWITCHES, ILLUMINATED OR NON-ILLUMINATED Panel cut-out.866" (22mm) or 1.161" x.846" (29.5mm x 21.5mm)

Thermal Overcurrent Circuit Breaker 3120-F...

INDUSTRIAL CONTROLS. Description. Products & features. Specifications. Illuminated or non-illuminated pushbutton switches.

Surface mounting, flush mounting, and DIN track mounting

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Position switches FC series

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

Miniaturized limit switches

SERIES MINIATURE SNAP-ACTION SWITCHES

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Prewired position switches FF series

Safety rope switch without reset for simple stop

CI-TI Contactors and motor starters Types CI 61 - CI 98

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

B Mini Contactor V Hz

Control & Signalling Devices 22.5 mm. RoHS. Compliant

XACA871 pendant control station XAC-A - 8 pushbuttons

Sealed pushbutton switches - bushing Ø 16 mm - momentary

Oiltight Switches & Pilot Devices

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Solenoid Locking Safety Switches

XACA871 pendant control station XAC-A - 8 pushbuttons

Position switches FR series

Single foot switches - PX and PA series

Thermal Overcurrent Circuit Breaker 3120-F...

Miniature microswitches - Positive break

9000 SERIES SUBMINIATURE MOMENTARY PUSHBUTTON SWITCHES Overview

Maintained selector switches, spring return selector switches with short or long knob

Description. Positive safety relays

Thermal Overcurrent Circuit Breaker 3120-F...

LS Series Limit Switches. Short Form Catalogue AC1300 ABB

AF40... AF96 3-pole contactors Technical data

K50H004UP cam changeover switch - 4-pole A - screw mounting

Product Information. Viewline Temperature gauges. Description. Gauge to indicate Coolant-, Engine oil-, Air- and Exhaust temperature.

Limit Switches - Limit Type Plastic Body IP65

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

Position switches FR series

Pilot Devices, Compact Range

Limit Switches - Limit Type Plastic Body IP65

Control stations and enclosures Pendant control stations, for control circuits Double insulated, type XAC-A

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

K30H001YP cam star-delta switch - 3-pole A - screw mounting

Compact plastic limit switches with positive opening mechanism

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

Safety switches for hinged doors

Product discontinuation. Notices. Measuring / Motor Protective Relays. Discontinuation Notice of Single-phase Voltage Relay K8AB-VW[].

Transcription:

Actuator with snap-action switching element Switching system Self-cleaning, double-break snap-action switching system with contact opening width 2 x 0.5 mm (switch with small contact opening width as per EN IEC 058-1). The switching elements are optionally equipped with the following switching functions: One to three normally open (NO) or normally closed (NC), or any combination of NO and NC plus connections for T1 3/4 LED or lamp. The number of switching elements cannot exceed three. The switching elements provided for the 3-position switch actuators are equipped with max. 2 NC or 2 NO or any combination. The number of switching elements cannot exceed two. Material Lens Raised mounting Polymethylmethacrylat (PMMA), as per UL 94 HB, flush mounting Polycarbonat (PC), as per UL 94 V0, or Aluminium anodized Front bezel Polyetherimid (PEI), as per UL 94 V0, or Aluminium anodized Front ring Aluminium anodized Material of contact Silver or silver with gold plating Switching element Diallylphthalate (DAP), as per UL 94 V0 and Polyamide (PA 66), as per UL 94 V0 Actuator housing Polyetherimide (PEI), as per UL 94 V0, self-extinguishing Mechanical characteristics Terminals Solder rigid flexible superflexible 1 wire 0.5 1.5 mm² 0.5 0.75 mm² 0.5 mm² 2 wires 0.75 mm² 0.5 mm² Tightening torque for fixing nut max. 50 Ncm Actuating torque Selector-/Keylock switch 2.5 10 Ncm Actuating force Pushbutton 2.7 3.6 N Rebound time The rebound times apply to normal manual activation Contact making 3 ms Contact breaking 5 ms Mechanical lifetime as per DIN IEC 60512-5-6 and EN IEC 60947-5-1 Pushbutton maintained action 1 million cycles of operation Pushbutton momentary action 2 million cycles of operation Keylock switch 50000 cycles of operation Selector switch 100000 cycles of operation Electrical characteristics Standards The devices comply with: EN IEC 058-1 and EN IEC 60947-5-1 Rated Operational U e 250 VAC/DC as per EN IEC 60947-1 Rated Insulation U i 320 VAC, Rated Impulse Withstand U imp 4 kv, Contact resistance New state with silver contact 100 mω as per DIN IEC 60512-2-4, measured at 100 ma, 10 V New state with gold plated contact 50 mω as per DIN IEC 60512-2-3, measured at 20 mv, 10 ma Electrical life 50 000 cycles of operation at 250 VAC, 5 A, cosφ 0.95, Electrostatic discharge (ESD) Keylock switch 11 kv Conventional free air thermal current I th 5 A, the maximum current in continuous operation and at ambient temperature must not exceed the quoted maximum values. Switch rating Switch rating AC with silver contact or silver contact with gold plating, service category AC-15, 125 VAC 250 VAC 2.5 A 2 A Switch rating DC for silver contact or silver contact with gold plating, service category DC-13, Actuating travel Pushbutton 3 mm 250 VDC 0.15 A Selector-/keylock switch 2 positions 3 positions Momentary action approx. 42 approx. 2 x 42 Maintained action approx. 90 approx. 2 x 90 Recommended minimum operational data Material of contact Silver Silver with gold plating 20 VAC/DC 5 VAC/DC 100 ma 10 ma

Actuator with snap-action switching element Electric strength 2500 VAC, 50 Hz, 1 min., as per DIN IEC 60512-2-11 between all terminals and earth Overvoltage category III, Protection class Class II, as per EN IEC 058-1 Degree of pollution 3, as per EN IEC 60947-1 Environmental conditions Storage temperature -40 C +85 C Operating temperature -25 C +55 C Protection degree as per EN IEC 60529 Front side IP 65, rear side IP 40 Shock resistance (semi-sinusoidal) max. 10 m/s², pulse width 11 ms, 3-axis, as per EN IEC 60068-2-27 Climate resistance Damp heat, cyclic 96 hours, +25 C/97 %, +55 C/93 % relative humidity, as per EN IEC 60068-2-30 Damp heat, state 56 days, +40 C/93 % relative humidity, as per EN IEC 60068-2-78 Rapid change of temperature 100 cycles, -40 C +80 C, as per EN IEC 60068-2-14 Approvals Approbations CB (IEC 058) CB (IEC 60947) CSA ENEC (EN 058) CCA-NTR (EN 60947) CCC CENELEC (IEC 60947-5-1) Germanischer Lloyd GOST UL SEV NFF Declaration of conformity CE Vibration resistance (sinusoidal) max. 100 m/s² at 10 Hz 500 Hz, as per EN IEC 60068-2-6

Actuator with slow-make switching element Switching system Double-break slow-make system, contact opening width 2 x 1.5 mm, with 2 x 2 contact points per switching element. NC-contact elements in the slow-make elements fulfill requirements of switches with forced opening 2.17. The slow-make elements are optionally obtainable with the following switching functions : 1 NO or 2 NO, 1 NC or 2 NC, 1 NO + 1 NC. Material Lens Raised mounting Polymethylmethacrylat (PMMA), as per UL 94 HB, flush mounting Polycarbonat (PC), as per UL 94 V0, or Aluminium anodized Front bezel Polyetherimid (PEI), as per UL 94 V0, or Aluminium anodized Front ring Aluminium anodized Material of contact Silver or gold (specified for operation for low level switching) Switching element Diallylphthalate (DAP), as per UL 94 V0 and Polyamide (PA 66), as per UL 94 V0 Actuator housing Polyetherimide (PEI), as per UL 94 V0, self-extinguishing Mechanical characteristics Terminals Solder rigid flexible superflexible 1 wire 0.5 1.5 mm² 0.5 0.75 mm² 0.5 mm² 2 wires 0.75 mm² 0.5 mm² Screw 1 wire 0.5 1.5 mm² 0.5 0.75 mm² 0.5 mm² 2 wires 0.75 mm² 0.5 mm² 0.5 mm² Tightening torque for fixing nut max. 50 Ncm Actuating torque Selector-/Keylock switch 4 16 Ncm Actuating force Pushbutton 3.5 11 N Emergency-stop switch max. 65 N Actuating travel Pushbutton 3 mm Emergency-stop switch 10 mm Selector-/keylock switch 2 positions 3 positions Momentary action approx. 42 approx. 2 x 42 Maintained action approx. 90 approx. 2 x 90 Rebound time 2 ms, contact making and contact breaking the rebound times apply to normal manual activation Mechanical lifetime as per DIN IEC 60512-5-6 and EN IEC 60947-5-1 Pushbutton maintained action 1 million cycles of operation Pushbutton momentary action 2 million cycles of operation Emergency-stop switch 6050 cycles of operation Keylock switch 50000 cycles of operation Selector switch 100000 cycles of operation Electrical characteristics Standards The devices comply with: EN IEC 058-1 and EN IEC 60947-5-1, EN IEC 60947-5-5 (Emergency-stop) Electrical life 50 000 cycles of operation at 250 VAC, 5 A, cosφ 0.95, Switching element of emergency-stop 6050 cycles of operation, as per EN IEC 60947-5-5 Electrostatic discharge (ESD) Keylock switch 11 kv Electric strength 4000 VAC, 50 Hz, 1 min., as per DIN IEC 60512-2 between all terminals and earth Overvoltage category III, Protection class Class II, as per EN IEC 058-1 Degree of pollution 3, as per EN IEC 60947-1 Electrical characteristics for silver contacts Rated Operational U e 250 VAC/DC as per EN IEC 60947-1 Rated Insulation U i 320 VAC, Rated Impulse Withstand U imp 4 kv, Contact resistance New state 50 mω, as per DIN IEC 60512-2-4, measured at 100 ma, 10 V Conventional free air thermal current I th 5 A, the maximum current in continuous operation and at ambient temperature must not exceed the quoted maximum values. Switch rating Switch rating AC with silver contact and screw terminal, service category AC-15, 125 VAC 250 VAC 3 A 2 A

Actuator with slow-make switching element Switch rating with silver contact and screw terminal, service category DC-13, 250 VDC 0.2 A Recommended minimum operational data 20 VAC/DC, 100 ma Electrical characteristics for gold contacts Rated Operational U e 50 VAC/DC, Rated Insulation U i U i = 320 VAC, Rated Impulse Withstand U imp 0.8 kv, as per EN IEC 60947-1 Contact resistance New state 50 mω as per DIN IEC 60512-2-4, measured at 20 mv, 10 ma Conventional free air thermal current I th 0.3 A, the maximum current in continuous operation and at ambient temperature must not exceed the quoted maximum values. Switch rating Switch rating AC with gold contact, service category AC-15, 50 VAC 0.5 A Switch rating with gold contact, service category DC-13, 50 VDC 0.1 A Recommended minimum operational data 10 mvac/dc 2 ma Protection degree as per EN IEC 60529 Frontside IP 65, rear side IP 40 Shock resistance (semi-sinusoidal) max. 100 m/s², pulse width 11 ms, 3-axis, as per EN IEC 60068-2-27 Vibration resistance (sinusoidal) max. 100 m/s² at 10 Hz 500 Hz, as per EN IEC 60068-2-6 Climate resistance Damp heat, cyclic 96 hours, +25 C/97 %, +55 C/93 % relative humidity, as per EN IEC 60068-2-30 Damp heat, state 56 days, +40 C/93 % relative humidity, as per EN IEC 60068-2-78 Rapid change of temperature 100 cycles, -40 C +80 C, as per EN IEC 60068-2-14 Approvals Approbations CB (IEC 058) CB (IEC 60947) CSA ENEC (EN 058) CCA-NTR (EN 60947) CCC CENELEC (IEC 60947-5-1) Germanischer Lloyd GOST UL SEV NFF Declaration of conformity CE Environmental conditions Storage temperature -40 C +85 C Operating temperature -25 C +55 C

Actuator with flasher element Material Lens Raised mounting Polymetylmethacrylat PMMA, as per UL 94 HB, flush mounting Polycarbonat (PC), as per UL 94 V0 Actuator housing Polyetherimide (PEI), as per UL 94 V0, self-extinguishing Flasher element Polyetherimide (PEI), as per UL 94 V0 Mechanical characteristics Terminals Soldering terminal Tightening torque for fixing nut max. 50 Ncm Flashing frequency 1 Hz ±0.25 Hz Pulse duty factor approx. 50 % Operating voltage 12 28 VAC/DC ±10 % Environmental conditions Operating temperature 0 C +45 C Protection degree as per EN IEC 60529 Front side IP 65, rear side IP 40 Electrical characteristics Illumination Filament lamp 14 VAC/DC 28 VAC/DC Power consumption 80 ma 44 ma Single-LED 12 VAC/DC 28 VAC/DC Power consumption 15 ma 18 ma

Lens plastic with symbols Chemical and mechanical tests 1. Wipe resistance according to EN 058-1 section 8.9 (Petrol/gasoline, distilled water, diluted alcohol) 2. Graffiti-Killer Test 3. Railway cleaning agents (Walo) 4. Damp/dry heat durability 5. UV test according to EN 60068-2-5 / 56 days 6. Mechanical life time 2 Mio. Operations (abrasive test)