Hedeager Aarhus N Denmark. Vestas V110-2 MW 50 Hz VCS Mk 10

Similar documents
Hedeager Aarhus N Denmark

Hedeager Aarhus N Denmark

Hedeager Aarhus N Denmark

Hedeager Aarhus N Denmark S (IEC IB)*, :2005

Hedeager Aarhus N Denmark. Vestas V MW / V MW

Hedeager Aarhus N Denmark

Avda. Ciudad de la Innovación Sarriguren (Navarra) Spain

Avda. Ciudad de la Innovación Sarriguren (Navarra) Spain

Avda. Ciudad de la Innovación Sarriguren (Navarra) Spain G MW IEC IIIA

ENERCON GmbH Dreekamp Aurich Germany ENERCON E-82 E4 2.35MW ENERCON E-82 E4 3.0MW. IIA, IEC : Amd1:2010

One Earth Opp. Magarpatta City Pune, India. Suzlon S120 DFIG 2.1MW (50 Hz)

Avda. Ciudad de la Innovación Sarriguren (Navarra) Spain

DB-DNVGL-SE DE-DNVGL-SE TT-DNVGL-SE ME-DNVGL-SE

One Earth Opp. Magarpatta City Pune, India

Holsterfeld Salzbergen Germany

TYPE CERTIFICATE Wind Turbine

Holsterfeld Salzbergen Germany GE

Wind Turbine Generator System. General Specification for HQ2000

Statement of Compliance on the A-Design Assessment

GENERAL SPECIFICATIONS

New dimensions. Siemens Wind Turbine SWT Answers for energy.

V MW & 2.0 MW Built on experience

Technical specifications. Wind Turbine GS 21 S. Power 60 kwp

G87-ingles 14/12/06 17:44 Página 2 GAMESA G MW

GRAND RENEWABLE ENERGY PARK PROJECT DESCRIPTION REPORT. Attachment C. Turbine Specifications

BENEFITS. Maximum unit power with excellent performance for high winds. - Class IA/WZII/WZIII.

BENEFITS. Maximum output at minimum cost per kwh for low wind sites. - Class IIIA/WZII.

V MW The future for low wind sites

BENEFITS. Maximum output at minimum cost per kwh for medium wind sites. - Class IIA.

Excel 10 (240 VAC, 1-phase, 60 Hz)

Test Summary Report for the Solid Wind Power SWP25-14TG20 Small Wind Turbine

Pioneer P750/49. The Premium 750 KW Wind Turbine. green. pioneer. go go with

T701 (240 VAC, 1-phase, 60 Hz)

V MW An efficient way to more power

SWCC Summary Report. Eveready Diversified Products (Pty) Ltd T/A Kestrel Renewable Energy. Certification Number: SWCC (240 VAC, 1-phase, 60 Hz)

APPENDIX J V90 3.0MW Turbine Specifications

General Specification

Bijlage 32 Technische gegevens SWT

ned100 Wind Turbine Generator a step towards your energy independence

Standard Uncertainty in AEP (kwh)

NIAGARA REGION WIND FARM PROJECT DESCRIPTION REPORT. Appendix C. Turbine Specifications

ENERCON GmbH ENERCON E-66. page 1 of 6. Design. Dreekamp 5 Tel.: / Aurich Fax: / Design

V MW Creating more from less

JOINT VENTURE: Wind Power Development Project United States of America. - Proposal Appendix -

LA10 (480 VAC, 3-phase, 60 Hz)

aeromaster wind turbines Reliable, compact, flexible and economical

SeaGen-S 2MW. Proven and commercially viable tidal energy generation

Smart Wind Turbine Solutions 2MW Platform

March Powerhouse Wind Ltd. Document Technical Summary for Thinair 102.

GOLDWIND 2.5MW PERMANENT MAGNET DIRECT-DRIVE (PMDD) WIND TURBINE

Reliability Driven By Technology. M a k e t h e r i g h t m o v e...

Certification and Shop Approval for Repair Work on Rotor Blades

S70/1500 kw S77/1500 kw. The perfect technology for each location. Sophisticated solutions for high-efficiency wind turbines.

Vestas Product Offering V MW at a Glance. Renato Loureiro Gonçalves Wind & Site Engineer

SWT Turning moderate wind into maximum results

Type. Transpoft and Assembly. Material

Green energy conversion

FD21-50 GHREPOWER. Version: 3.0

GE Renewable Energy. GE s 3 MW Platform POWERFUL AND EFFICIENT.

RW-30kW variable pitch wind turbine

Technical Documentation Wind Turbine Generator Systems /60 Hz

EP4-Platform: E-126 EP4 / E-141 EP4. Arno Hildebrand, Programm Manager EP4 ENERCON Research & Development

ABB Wind Power Solution

Report Inspection of wind turbine

GARUDA WIND ELECTRIC GENERATOR

Product Presentation. September 09

Are you looking for the maximum return on your investment in wind energy?

S70/1500 KW S77/1500 KW. Nordex S70/S77 The perfect technology for each location.

Evaluation of HALUS Power systems

Finance your Energy Project

HAF WIND ENERGY PROJECT WIND TURBINE SPECIFICATION REPORT

EXPERT REMANUFACTURED WIND TURBINE

Technology Requirements for Cold and Tropical Wind-Diesel Applications. Chris McKay Product Manager Northwind 100 Ottawa 2009

Small Wind Energy - International Standards. Small Wind Energy International Standards. Overview

General Specification V MW IEC IIA

Report Inspection of wind turbine

Project Report on Engineering Services for the Wind Turbine Project at the Cuyahoga County Fair

German-American Chamber of Commerce Offshore wind conference Jersey City, NJ October 18, 2011

Annexe D1. Caractéristiques techniques des éoliennes REpower MM82 et MM92

Versatile and Powerful. Liduro Wind Frequency Converter System

The company. Operational philosophy. Worldwide presence. Product and design philosophy. our customers permanent performance

Electrical Pitch System

Wind Turbine Generator System Safety and Function Test Report. Atlantic Orient 15/50 Wind Turbine

Wind Generation and its Grid Conection

Renewable Energy Systems

V MW Making wind even more profitable

H4.6-3kW/H6.4-5kW/H8.0-10kW/H9.0-20kW. Technical Overview ANHUI HUMMER DYNAMO CO., LTD.

WE CANNOT SOLVE OUR PROBLEMS WITH THE SAME LEVEL OF THINKING THAT CREATED THEM.

ev W 40kW Product specification

Siemens Cold Climate Strategy

Lenze. Drives with worm gearboxes 52.

WE CANNOT SOLVE OUR PROBLEMS WITH THE SAME LEVEL OF THINKING THAT CREATED THEM. Albert Einstein

WE CANNOT SOLVE OUR PROBLEMS WITH THE SAME LEVEL OF THINKING THAT CREATED THEM.

CORE VALUES TECHNOLOGIES ESS-ESD PRODUCT CATALOGUE Enjoy the peace of mind ENGINE POWER SUPPLIERS AND EQUIPMENT HEAT

Report Turbine inspection WTG 15035, Groettocht 7

STATE OF THE ART and NEW TECHNOLOGIES OF DIRECT DRIVE WIND TURBINES

Adelaide Wind Power Project Turbine T05 (AD117) IEC Edition 3.0 Measurement Report

ORDERLY NEGOTIATED SALE MICON M1500 WIND TURBINES EQUIPMENT CATALOG AUCTION DIVISION Rochester, Minnesota

REpower 3.2M114. [3.2M/114/50 Hz] Product Description Preliminary Version

Report Turbine inspection WTG 12801, Oudelandertocht 11

Transcription:

Certificate No. This certificate is issued to for the wind turbine wind turbine class (class, standard, year) Vestas Wind Systems A/S Hedeager 42 8200 Aarhus N Denmark Vestas V110-2 MW 50 Hz VCS Mk 10 WT class S, IEC 61400-1: 2005+Amd1: 2010 This certificate is transferred from IEC 61400-22 to IECRE and attests compliance with IEC 61400 Series as specified in subsequent pages. It is based on the following reference documents: Design basis evaluation conformity statement Design evaluation conformity statement Type test conformity statement Manufacturing conformity statement Type characteristics conformity statement Final evaluation report DB-DNVGL-SE-0074-01323-5 DE-DNVGL-SE-0074-01324-5 TT-DNVGL-SE-0074-01325-5 ME-DNVGL-SE-0074-01326-5 TCM-DNVGL-SE-0074-01328-3 FER-TC-DNVGL-SE-0074-01322-5 The conformity evaluation was carried out in accordance with the rules and procedures of the IECRE System www.iecre.org The wind turbine type specification begins on page 2 of this certificate. Changes in the system design or the manufacturer s quality system are to be approved by the Certification Body. Without approval, the certificate loses its validity. This certificate is valid until: 2020-01-16 Approved for issue on behalf of the IECRE Certification Body: Mark Wollenberg / Christer Eriksson Project Manager / Service Line Leader, Type Certification Hellerup 2018-11-30 Renewables Certification Brooktorkai 18 20457 Hamburg, Germany Issued 2018-11-30 1/10

Machine parameters: Power regulation: Rotor orientation: Number of rotor blades: 3 Rotor tilt: 6 Cone angle: 3 pitch-controlled upwind Rated power: 2000 / 2100 / 2200 kw (refer to annex 1 for details) 2000 kw: derating strategy for cooler top 30 at ambient temperature above 35 C 2000 kw: derating strategy for cooler top 40 at ambient temperature above 40 C 2100 kw, 2200 kw: derating strategies for ambient temperature above 30 C Rated wind speed Vr: 9.6m/s (2000 kw) 10 m/s (2100 kw) 10 m/s (2200 kw) Rotor diameter: 110 m Hub height(s): Hub height operating wind speed range Vin Vout: Design life time: 95 m, T2X420 110 m, T2X430, TS192 125 m, T2X431 (refer to annex 1 for details) 3-20 m/s (2100 and 2200 kw) 3-22 m/s (2000 kw) 20 years Software version: VMP Global 17.06 Wind conditions: Characteristic turbulence intensity Iref at Vhub = 15 m/s: See annex 1 Annual average wind speed at hub height Vave : See annex 1 Reference wind speed Vref : See annex 1 Weibul shape factor (k) See annex 1 Mean flow inclination: 8 Hub height 50-year extreme wind speed Ve50: See annex 1 Electrical network conditions: Normal supply voltage and range: 10500 V - 35000 V Normal supply frequency and range: 50 Hz Voltage imbalance: <3 % Maximum duration of electrical power network outages: Not dimensioning Number of electrical network outages 50 / year Issued 2018-11-30 2/10

Other environmental conditions (where taken into account): Normal and extreme temperature ranges: See annex 1 Relative humidity of the air: Air density: See annex 1 Solar radiation: Lightning protection system (standard and protection class): 100 % (max 10 % of lifetime) The turbine shall resist solar radiation (including UV) with 1000 W/m 2 and 8000 MJ/m 2 per year throughout the design lifetime IEC 61400-24:2010, Protection Level 1 Issued 2018-11-30 3/10

Major components: **If not otherwise stated, the certificate holder is the manufacturer. Blade: Material: Blade length: Number of blades: 3 54m Structural shell Vestas Wind Systems A/S, TPI China Glass fibre and carbon fibre reinforced epoxy 54m 29061061 or 29083499 (2000 kw) 29061061 (2100 and 2200 kw) Blade bearing: 2 row 4-point contact ball bearing Rollix 13-1920-02-DD0-5 Blade bearing: 2 row 4-point contact ball bearing Liebherr 648 VO 802-000 Blade bearing: 2 row 4-point contact ball bearing TMB B030.65.1920K Pitch System: Motor / Actuator Pitch Controller One hydraulic cylinder per blade Hydraulic LJM Issued 2018-11-30 4/10

Pitch System: Motor / Actuator Pitch Controller One hydraulic cylinder per blade Hydraulic Glual Pitch System: Motor / Actuator Pitch Controller One hydraulic cylinder per blade Hydraulic Hine Main shaft: Forged hollow trumpet shaft Material: 42CrMo4 29085836 Main bearing: Two double row spherical roller bearing SKF 230/630 CA/HM2 W33 24188 ECA/HM2 W33 Main bearing: Two double row spherical roller bearing KOYO 230/630 RHAW33T 24188 RHAW33 Main bearing: Two double row spherical roller bearing FAG F-582558.PRL-WPO F-582559.PRL-WPO Gearbox: 3 stage planetary gearbox Issued 2018-11-30 5/10

Winergy Gear Ratio: 1:112.2 PEAB 4440 Gearbox: 3 stage planetary gearbox ZF Gear Ratio: 1:112.36 Atlas 1.2, 1.21 Yaw System: Drive Electrical motor ABB or Lafert 29005012* * Note, verified for use of either 5 or 6 yaw drives Bearing Friction Bearing (PETP slide plate) Vestas Wind System A/S 29011239.V01 Gear Planetary-/worm gear combination Bonfiglioli, Comer 29014048 (left) /29014049 (right) Brake Friction brake, motor brake included in the drive unit ABB or Lafert 29005012 Generator: Type DVSG 500/4M SP. (Asynchronous generator with wound rotor) Vestas Wind System A/S Issued 2018-11-30 6/10

Rated Power: Rated Frequency: Rated Speed: Rated Voltage: Rated Current: Insulation Class: Degree of Protection: 2060 kw or 2260 kw 50 Hz 1680 rpm 690 VAC 1573 A or 1713 A H/H IP54 0007-0081.V09 (2060 kw) 0057-1280.V02 (2260kW) Converter: Rated Voltage (grid side): Full quadrant IGBT Vestas Wind System A/S 480 V Nominal current (at 2.0 MW) Grid Rotor Nominal current (at 2.2 MW) 240 A 592 A Grid 256 A Rotor 655 A Degree of Protection: IP 54 Transformer: Rated Voltage: Dry type Siemens HV side: 10500-35000 V LV side: 690 V +/-2% & 480 V +/-2% Transformer: Rated Voltage: Dry type SGB HV side: 10500-35000 V LV side: 690 V +/-2% & 480 V +/-2% Issued 2018-11-30 7/10

Transformer: Rated Voltage: Dry type JST HV side: 10500-35000 V LV side: 690 V +/-2% & 480 V +/-2% Tower: Sections: 4 Hub height: Tubular steel 95 m 0063-1772.V0 (T2X420) (please refer to annex 1 for details) Tower: Sections: 4 Hub height: Tubular steel 110 m 0063-1776.V0 (T2X430) (please refer to annex 1 for details) Tower: Sections: 4 Hub height: Tubular steel 110 m 0046-8897.V0 (TS192) (please refer to annex 1 for details) Tower: Sections: 5 Hub height: Tubular steel 125 m 0063-1777.V0 (T2X431) (please refer to annex 1 for details) Manuals: Operation & maintenance manual: Issued 2018-11-30 8/10 See list of manuals 0068-9605.V01

Transport manual: Installation & commissioning manual: See list of manuals 0068-9605.V01 See list of manuals 0068-9605.V01 Issued 2018-11-30 9/10

Annex 1 Configuration matrix Tower Rated power (kw) I ref V ave (m/s) Weibull (k) v ref (m/s) v e50 (m/s) Operating temp. Extreme temp. Air density range ( C) range ( C) (kg/m 2 ) T2X420 2100 0.14 7.10 2.5 37.5 52.5-10 to +40-20 to +50 1.18 T2X420 2000 0.14 7.50 2.5 37.5 52.5-10 to +40-20 to +50 1.12 T2X420 2200 0.14 6.50 2.5 37.5 52.5-10 to +40-20 to +50 1.12 T2X430 2100 0.13 7.14 2.78 37.5 52.5-10 to +40-20 to +50 1.092 T2X430 2000 0.12 7.50 2.78 37.5 52.5-10 to +40-20 to +50 1.06 T2X430 2100 0.12 7.00 2.78 37.5 52.5-10 to +40-20 to +50 1.06 T2X430 2200 0.12 6.50 2.78 37.5 52.5-10 to +40-20 to +50 1.06 T2X431 2100 0.14 7.10 2.5 35.0 49.0-10 to +40-20 to +50 1.18 T2X431 2000 0.11 7.50 2.5 35.0 49.0-10 to +40-20 to +50 1.12 T2X431 2100 0.11 7.00 2.5 35.0 49.0-10 to +40-20 to +50 1.12 T2X431 2200 0.11 6.50 2.5 35.0 49.0-10 to +40-20 to +50 1.12 TS192 2100 0.13 7.00 2.78 35.0 49.0 5 to +40* -20 to +50 1.092 TS192 2000 0.13 7.14 2.78 35.0 49.0 5 to +40* -20 to +50 1.092 TS192 2200 0.13 6.5 2.78 35.0 49.0 5 to +40* -20 to +50 1.092 * Special temperature Turbine (SpT) intended for climate conditions with temperatures above 5 C. In these conditions the heating fans are found to be redundant and can therefore be removed. Issued 2018-11-30 10/10