CRN3-3 A-FGJ-G-V-HQQV 3x230/400 50HZ

Similar documents
CRN3-6 A-P-G-V-HQQV 3x230/400 50HZ

CRI3-6 A-FGJ-I-E-HQQE 3x230/400 50HZ

CRN1-27 A-P-G-V-HQQV 3x230/400 50HZ

CRN15-01 A-P-G-V-HQQV 3x230/ HZ

CRN3-11 A-P-G-V-HQQV 11kW 3x400Y 50Hz

CRN15-17 A-FGJ-G-V-HQQV 3x400/ HZ

CRN20-02 A-FGJ-G-E-HQQE 3x400D 50 HZ

CR3-2 A-FGJ-A-E-HQQE 3x230/400 50HZ

CRI1-6 A-P-I-E-HQQE 3x230/400 50HZ

CRN45-10 A-F-G-V-HQQV 3x400/ HZ

CRN A-F-G-V-HQQV 3x400/ HZ

CR5-6 A-FGJ-A-E-HQQE 3x230/400 50HZ

CRN A-F-G-V-HQQV 30kW 3x400D 50Hz

CRN15-03 A-P-G-V-HQQV 3x400D 50 HZ

CR3-19 A-FGJ-A-E-HQQE 3x230/400 50HZ

CRN5-7 A-P-G-E-HQQE 3x230/400 50HZ

CR A-F-A-V-HQQV 3x400/ HZ

CRN45-5 A-F-G-V-HQQV 3x400/ HZ

CR1-6 A-A-A-E-HQQE 3x230/400 50HZ

CR1-3 A-A-A-E-HQQE 3x230/400 50HZ

CRN3-25 A-P-G-E-HQQE 3x400D 50HZ

CRNE15-03 A-FGJ-G-V-HQQV 3x HZ

CRN A-F-G-V-HQQV 3x400/ HZ

CR3-6 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR1-3 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR15-02 A-F-A-E-HQQE 3x400D 50 HZ

CR3-10 A-A-A-E-HQQE 3x230/400 50HZ

CR10-02 A-A-A-E-HQQE 3x230/ HZ

CR5-16 A-A-A-E-HQQE 3x400D 50HZ

CR10-04 A-A-A-E-HQQE 15kW 3x400Y 50Hz

CRN120-7 A-F-G-V-HBQV 75kW 3x400D 50Hz

CR5-26 A-FGJ-A-E-HQQE 3x400D 50HZ

CR3-13 A-A-A-E-HQQE 1x220/240 50HZ

CR1S-6 A-A-A-E-HQQE 1x220/240 50HZ

CR1-9 A-A-A-E-HQQE 1x220/240 50HZ

CR A-F-A-V-HBQV 3x400/ HZ

CR45-10 A-F-A-E-HQQE 3x400/ HZ

CR10-01 A-A-A-E-HQQE 1x220/ HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR45-5 A-F-A-E-HQQE 3x400/ HZ

CRN5-5 A-FGJ-G-V-HQQV 3x230/400 50HZ

CR A-F-A-E-HQQE 3x400/ HZ

CRNE5-10 A-FGJ-G-E-HQQE 3x400 50HZ

CR15-10 A-F-A-E-HQQE 11kW 3x400D 50Hz

CR10-10 A-A-A-E-HQQE 3x400D 50 HZ

CR120-2 A-F-A-E-HQQE 3x400/ HZ

CRN A-F-G-V-HQQV 3x400/ HZ

CRN10-09 A-FGJ-G-V-HQQV 3x400D 50 HZ

CRE45-1 A-F-A-E-HQQE 3x HZ

CRN1S-9 A-P-G-V-HQQV 3x230/400 50HZ

CRE20-03 A-A-A-E-HQQE 3x HZ

CRN5-22 A-P-G-V-HQQV 3x400D 50HZ

Grundfos pump

CRN120-3 A-F-G-V-HQQV 3x400/ HZ

CRE15-01 A-F-A-E-HQQE 1x HZ

CRI5-4 A-FGJ-I-E-HQQE 3x230/400 50HZ

CRE5-16 A-A-A-E-HQQE 3x400 50HZ

CRI10-04 A-FGJ-I-E-HQQE 3x230/ HZ

CRE32-3 AN-F-A-E-HQQE 3x HZ

CR5-7 A-FGJ-A-E-HQQE 3x230/400 50HZ

CRE A-F-A-E-HQQE 3x HZ

CR1-4 A-FGJ-A-E-HQQE 3x230/400 50HZ

CRE10-02 A-A-A-E-HQQE 1x HZ

CRN3-7 A-P-G-E-HQQE 3x230/400 50HZ

CRI15-04 A-FGJ-I-E-HQQE 3x400D 50 HZ

CR3-17 A-FGJ-A-E-HQQE 1x220/240 50HZ

CRI3-25 A-P-I-E-HQQE 3x400D 50HZ

CR5-18 A-FGJ-A-E-HQQE 3x400D 50HZ

CR15-01 A-F-A-E-HQQE 3x230/ HZ

CRN10-02 A-P-G-E-HQQE 3x230/ HZ

CR A-F-A-E-HQQE 3x400D 50 HZ

CR5-9 A-A-A-E-HQQE 3x230/400 50HZ

CR45-3 A-F-A-E-HQQE 3x400/ HZ

NB /193 A-F2-A-BAQE

CR1-4 A-A-A-E-HQQE 3x230/400 50HZ

CR3-7 A-A-A-E-HQQE 1x220/240 50HZ

CR10-08 A-A-A-E-HQQE 3x400D 50 HZ

CR15-14 A-F-A-E-HQQE 3x400/ HZ

TP /4-A-F-A-BQQE 400Y 50HZ

Hydro MPC-E 2CRIE L GNL

CRE A-F-A-E-HQQE 3x HZ

NK /310A2F1AE-SBAQE

TP /2-A-F-A-BQQE 400D 50HZ

CRE20-08 A-F-A-E-HQQE 3x HZ

NB80-160/161 A-F2-A-BQQE

TP /2-A-F-A-BAQE 400D 50HZ

TP /4-A-F-A-BUBE 400Y 50HZ

TP 40-30/4-A-F-A-BUBE 400Y 50HZ

NB /263 AS-F2-A-BAQE

CRN5-8 A-P-G-V-HQQV 3x230/400 50HZ

CRN1S-21 A-FGJ-G-E-HQQE 3x230/400 50HZ

CRT 2-4 A-P-A-E-AUUE 055kW 400Y 50Hz

NB /438 A-F1-A-GQQE

CRIE10-03 A-FGJ-I-E-HQQE 3x HZ

CM1-6 A-R-I-E-AQQE F-A-A-N

CRN15-09 A-P-G-V-HQQV 3x400/ HZ

NK40-160/172A1F2AE-SBAQE

CM15-1 A-R-I-V-AQQV C-A-A-N

Transcription:

GRUNDFOS DATA BOOKLET CRN3-3 A-FGJ-G-V-HQQV 3x23/4 5HZ Grundfos Pump 9651685 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn3/9651685/crn-3-3-a-fgj-g-v-hqqv.html info@lenntech.com tel. +31-15-261.9. fax. +31-15-261.62.89 BE > THINK > INNOVATE

Position Qty. Description 1 CRN 3-3 A-FGJ-G-V-HQQV Product No.: 9651685 Note! Product picture may differ from actual product Vertical, multistage centrifugal pump with suction and discharge ports on same the level (in-line) enabling installation in a horizontal one-pipe system. Pump materials in contact with the liquid are in high-grade stainless steel. A cartridge shaft seal ensures high reliability, safe handling and easy service and access. Power transmission is via a split coupling. Pipework connection is via combined DIN-ANSI-JIS flanges. The pump is fitted with a 3-phase, fan-cooled asynchronous motor. Further product details Steel, cast iron and aluminium components have an epoxy-based coating made in a cathodic electro-deposition (CED) process. CED is a high-quality dip-painting process where an electrical field around the products ensures deposition of paint particles as a thin, well-controlled layer on the surface. An integral part of the process is a pretreatment. The entire process consists of these elements: 1) Alkaline-based cleaning. 2) Zinc phosphating. 3) Cathodic electro-deposition. 4) Curing to a dry film thickness 18-22 my m. The colour code for the finished product is NCS 9/RAL 95. Pump A standard split coupling connects the pump and motor shaft. It is enclosed in the pump head/motor stool by means of two coupling guards. The pump head and flange for motor mounting is made in one piece (cast iron). The pump head cover is a separate component (stainless steel). The pump head has a combined 1/2" priming plug and air vent screw. 1/9

Position Qty. Description The pump is fitted with a balanced O-ring seal unit with rigid torque transmission system. This seal type is assembled in a cartridge unit which makes replacement safe and easy. Due to the balancing, this seal type is suitable for high-pressure applications. The cartridge construction also protects the pump shaft from possible wear from a dynamic O-ring between pump shaft and shaft seal. Primary seal: - Rotating seal ring material: Silicon carbide (SiC) - Stationary seat material: Silicon carbide (SiC) This material pairing is used where higher corrosion resistance is required. The high hardness of this material pairing offers good resistance against abrasive particles. Secondary seal material: FKM (fluorocarbon rubber) FKM has excellent resistance to oils and chemicals. Above 9 C, FKM should only be used in media without water. The shaft seal is screwed into the pump head. The chambers and impellers are made of stainless steel sheet. The chambers are provided with a PTFE neck ring offering improved sealing and high efficiency. The impellers have smooth surface, and the shape of the blades ensure a high efficiency. The pump has a stainless steel base mounted on a separate base plate. The base and base plate are kept in position by the tension of the staybolts which hold the pump together. The discharge side of the base has a combined drain plug and bypass valve. The pump is secured to the foundation by four bolts through the base plate. The flanges are fastened to the base by means of locking rings. Motor The motor is a totally enclosed, fan-cooled motor with principal dimensions to IEC and DIN standards. The motor is flange-mounted with tapped-hole flange (FT). Motor mounting designation in accordance with IEC 634-7: IM B 14 (Code I) / IM 361 (Code II). Electrical tolerances comply with IEC 634. The motor does not incorporate motor protection and must be connected to a motor-protective circuit breaker which can be manually reset. The motor-protective circuit breaker must be set according to the rated current of the motor (I1/1). The motor can be connected to a variable speed drive for adjustment of pump performance to any duty point. Grundfos CUE offers a range of variable speed drives. Please find more information in Win-/WebCAPS. 2/9

Technical data Liquid: Pumped liquid: Liquid temperature range: Liquid temp: Density: Technical: Speed for pump data: Rated flow: Rated head: Shaft seal: Approvals on nameplate: Curve tolerance: Materials: Pump housing: Impeller: Water 253.. 363 K 293 K 998.2 kg/m³ 2873 rpm 3 m³/h 15.1 m HQQV CE,TR ISO 996:1999 Annex A Stainless steel DIN W.-Nr. 1.448 AISI 316 ASTM A 351 CF 8M Stainless steel DIN W.-Nr. 1.441 AISI 316 Installation: Maximum ambient temperature: 313 K Max pressure at stated temp: 25 bar / 9 C 25 bar / -2 C Flange standard: DIN Pipe connection: DN 25 / DN 32 Pressure stage: PN 16 / PN 25 Flange size for motor: FT85 Electrical data: Motor type: 71A IE Efficiency class: NA Number of poles: 2 Rated power - P2:.37 kw Power (P2) required by pump:.37 kw Mains frequency: 5 Hz Rated voltage: 3 x 22-24 D/38-415 Y V Rated current: 1,74/1, A Starting current: 49-53 % Cos phi - power factor:,8-,7 Rated speed: 285-288 rpm Efficiency: 78,5% Motor efficiency at full load: 78,5 % Motor efficiency at 3/4 load: 79,-76,5 % Motor efficiency at 1/2 load: 75,5-71,5 % Enclosure class (IEC 34-5): 55 (Protect. water jets/dust) Insulation class (IEC 85): F Others: Minimum efficiency index, MEI :.7 Net weight: 2.6 kg Gross weight: 23.3 kg 3/9

Position Qty. Description Shipping volume:.5 m3 4/9

9651685 CRN 3-3 5 Hz H [m] CRN 3-3, 3*4 V, 5Hz Pumped liquid = Water Liquid temperature = 293 K Density = 998.2 kg/m³ eta [%] 22 2 1 18 9 16 8 14 7 12 6 1 5 8 4 6 3 4 2 2 1.2.4.6.8 1. 1.2 1.4 1.6 1.8 2. 2.2 2.4 2.6 2.8 3. 3.2 3.4 3.6 3.8 4. 4.2 4.4 P [W] 35 3 P1 Q [m³/h] NPSH [m] 7 6 25 2 P2 5 4 15 3 1 2 5 1 5/9

Description Value Product name: CRN 3-3 A-FGJ-G-V-HQQV Product No: 9651685 EAN number: 5739675989 Technical: Speed for pump data: 2873 rpm Rated flow: 3 m³/h Rated head: 15.1 m Impellers: 3 Shaft seal: HQQV Approvals on nameplate: CE,TR Curve tolerance: ISO 996:1999 Annex A Stages: 3 Pump version: A Model: A H [m] 22 2 18 16 14 12 1 8 6 4 2 CRN 3-3, 3*4 V, 5Hz Pumped liquid = Water Liquid temperature = 293 K Density = 998.2 kg/m³.5 1. 1.5 2. 2.5 3. 3.5 4. P [W] Q [m³/h] P1 eta [%] 1 9 8 7 6 5 4 3 2 1 NPSH [m] Materials: Pump housing: Impeller: Material code: Code for rubber: Stainless steel DIN W.-Nr. 1.448 AISI 316 ASTM A 351 CF 8M Stainless steel DIN W.-Nr. 1.441 AISI 316 G V 2 1 14 15 89 32 85 18 21 P2 4 2 Installation: Maximum ambient temperature: 313 K Max pressure at stated temp: 25 bar / 9 C 25 bar / -2 C Flange standard: DIN Connect code: FGJ Pipe connection: DN 25 / DN 32 Pressure stage: PN 16 / PN 25 Flange size for motor: FT85 19 141 191 14 G 1/2 19 x 27 282 4 x 13 75 34 1 15 25 Liquid: Pumped liquid: Liquid temperature range: Liquid temp: Density: Water 253.. 363 K 293 K 998.2 kg/m³ Electrical data: Motor type: 71A IE Efficiency class: NA Number of poles: 2 Rated power - P2:.37 kw Power (P2) required by pump:.37 kw Mains frequency: 5 Hz Rated voltage: 3 x 22-24 D/38-415 Y V Rated current: 1,74/1, A Starting current: 49-53 % Cos phi - power factor:,8-,7 Rated speed: 285-288 rpm Efficiency: 78,5% Motor efficiency at full load: 78,5 % Motor efficiency at 3/4 load: 79,-76,5 % Motor efficiency at 1/2 load: 75,5-71,5 % Enclosure class (IEC 34-5): 55 (Protect. water jets/dust) Insulation class (IEC 85): F Motor protec: NONE Motor No: 858512 HIGH VOLTAGE DIRECTION OF ROTATION LOW VOLTAGE DIRECTION OF ROTATION L1 L2 L3 L1 L2 L3 98.3169 6/9

Description Value Others: Minimum efficiency index, MEI :.7 Net weight: 2.6 kg Gross weight: 23.3 kg Shipping volume:.5 m3 7/9

9651685 CRN 3-3 5 Hz 19 141 282 G 1/2 14 19 x 27 4 x 13 75 89 15 14 191 1 15 25 34 85 18 21 32 Note! All units are in [mm] unless others are stated. Disclaimer: This simplified dimensional drawing does not show all details. 8/9

9651685 CRN 3-3 5 Hz HIGH VOLTAGE DIRECTION OF ROTATION L1 L2 L3 L1 L2 L3 LOW VOLTAGE DIRECTION OF ROTATION 98.3169 Note! All units are in [mm] unless others are stated. 9/9

Disclaimer: The information about the Grundfos pump in this document may be outdated. Data may be subject to alterations without further notice. Please contact us to verify the data above is still accurate/up-to-date. All information is copyright Grundfos. info@lenntech.com www.lenntech.com tel. +31-15-261.9. fax. +31-15-261.62.89