Caution. Description. Specifications and Ordering Information and Accelerometers

Similar documents
and Accelerometers Bently Nevada* Asset Condition Monitoring

and Accelerometers

200150, & Accelerometers Bently Nevada* Asset Condition Monitoring

PPT 802, Proximity Probe Transducer System

Hydro Stator End Winding Accelerometer System

Proximity Transducers, Seismic Sensors and Accessories

Hydro Stator End Winding Accelerometer System

Proximity Transmitters, and Seismic Vibration Transmitters

Part Number Revision NC, September High Temperature Velocity and Acceleration Sensor Operation and Maintenance Manual

MODEL 205 ce VIBRATION METER

Industrial Monitoring Instrumentation

Ø 68 mm to ø 115 mm. Material: Weight: Shaft Loads: Enclosure Rating: Connection Options. Cable: Cable Glands:

Operation Manual Bently Nevada Asset Condition Monitoring

Ø 68 mm to ø 115 mm. Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating:

Proximity Transmitters, and Seismic Vibration Transmitters

Model 648A ma Output Accelerometer. Installation and Operating Manual

Material: Weight: Shaft Loads: Enclosure Rating: Cable: Cable Glands:

Type 2REX-A. Oil & Gas / Heavy Industry

Acceleration Sensor AS - 030

Seismic Sensor Accessories SA, SV & ST 6000 Series

Model 643A ma Output Velocity Sensor. Installation and Operating Manual

Sensors for Road Load Measurements Accelerometers, Pressure Sensors, Force Sensors, Strain Sensors, Load Cells, and Signal Conditioners

Weatherproof Tubular Slip Ring Assembly

PXT-K Series. Pressure Transmitters Section 05

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

REMOTE MOUNT SOLENOID DRIVER (0-5 VDC/0-20 ma/10k Potentiometer Input)

Product Manual MNX10003 / REV B MODEL MH130 MODEL MH101-1B MODEL MH107-1B / MH107-1A MODEL MH118

STAR. series. Servo proportional valve Rated flows up to 80 l/m. Features

FM Approved Remote Kit Assembly (Part No ) Standard Remote Kit Assembly (Part No ) G2 SERIES G2 Industrial METER MODULES

series 2-Stage Servovalve Rated flows up to 80 l/m Features

Railway vibration measurement. Enhance safety and cut maintenance costs

Instruction Manual. Vibration Severity Meter VM12

Product Manual MNX10003 / REV C MODEL MH130 MODEL MH101-1B MODEL MH107-1B / MH107-1A MODEL MH118

Acceleration sensors (ICP technology) VBS 50 overview Configurations

Micro-Machined Silicon Transducers

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

797V Piezoelectric Velocity Sensor

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Model DFX Doppler ultrasonic flow meter

SRS SEALED ROTARY SENSORS

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

PX409 Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-10 inh2o to psid

FasTrak High Capacity Smart Positioner

Application Information

STAR. series. 2-Stage Servovalve Flight Simulation Motion Control. Features

EMC and Power Quality. Three-phase filters FN FN FN 3025/FN FN FN FN FN FN

Type A-10 General Purpose Pressure Transmitter

VIBRATION SENSORS VIBRATION SENSORS

PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED WITH OBE

Ultra High Purity Transducer, Ex na nl Models WU-20, WU-25 and WU-26

TRC ELECTRONICS, INC DC/DC Converter SIP Package 6W MEAN WELL SPBW06 & DPBW06 Series

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (0-10VDC Input Version)

Fisher i2p 100 Electro Pneumatic Transducer

Type A-10 General Purpose Pressure Transmitters

TOTAL CUSTOMER SATISFACTION GUARANTEED

Instruction Manual. Vibration Calibrators VC10 VC11 VC12 VC13

CHASSIS MOUNT DC-DC CONVERTERS 4:1 WIDE INPUT RANGE, 150 WATTS RAILWAY APPLICATIONS FWB(D)150 SERIES*

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /09

P500 Pressure Sensor. Description. Features. Applications MAIN FEATURES

HX-P420 SERIES 4 to 20 ma OUTPUT

Instruction Manual. Vibration Calibrator VC20. Manfred Weber. Metra Mess- und Frequenztechnik in Radebeul e.k. Meissner Str D Radebeul

Electronic Circuit Breaker ESS20-0..

Hydro-Flow Model 2200 Installation and Operation Guide B

SL Series Application Notes. SL Series - Application Notes. General Application Notes. Wire Gage & Distance to Load

Vacuum pumps/generators Small

STAR. series. 2-Stage Servovalve Rated flows up to 7 l/m. Features

Hydro-Flow Model 3100

TZIM. Electropneumatic Analog Positioner 10/ EN

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

ATEX Certificate of the QM-System page 2. Elektromagnetic Sensors DSE... pages Ferrostat sensors DSF.. pages

2100 Turbine Flow Sensor

Video & Power Over Coax Kit

AST44LP Intrinsically Safe Low Pressure Transducers / Transmitters

MS Application. Features. Proportional Valve Actuator General Instructions

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

S-SERIES DISPLACEMENT TRANSDUCERS

Model 550 Series Vibration Switches

2-way proportional throttle valve for block installation

Encoder Installation Manual Dynapar brand SERIES M21 Modular Encoder

Industrial Power Supplies

STT280 SEALED TILT SENSOR

Installation Manual A Digital Tachometer. Part Number Rev. H (09/07)

STAR. series. 2-Stage Servovalve Rated flows up to 20 l/m. Features

TECHNICAL BULLETIN. Logix 520MD Series Digital Positioner. Experience In Motion FCD LGENTB /09

Series Level-Trol Electronic Liquid Level Transmitters

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

Eddy Probe Systems Catalog. Probes and drivers Mounting devices Housings Pressure feedthroughs Calibrators and simulators Accessories

Temposonics. E-Series Analog + Start / Stop. Magnetostrictive Position Sensors. Temposonics EP Measuring range mm / mm SENSORS

Ultra High Purity Transducer, Ex na n Models WUC-10, WUC-15 and WUC-16

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

0745A Load Cell. Global Usage Fully Approved for Accuracy and Safety. 0745A Beam Load Cell Fully Approved

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

CTE7000 / CTU7000 Series Miniature pressure transmitters

Continental Hydraulics Installation Manual CEM-AA-A

Piezoelectric, Quartz Pressure Sensors for Dynamic Pressure Measurements

Transcription:

R Specifications and Ordering Information 200350 and Accelerometers Description The 200350 and Accelerometers are general purpose, case-mounted seismic transducers designed for use with Trendmaster Pro Constant Current Direct Input Card 149811-02 and the Seismic Direct Input Card 164746-01. The 200350 and Accelerometers are contained within a hermetically sealed, stainless steel case. The design provides an extremely rugged transducer, wellsuited for harsh industrial environments. Each transducer s top mounted, 2-pin connector (MIL-C-5015) allows for easy installation and removal of the interconnecting signal cable. A ¼-28 threaded hole on the bottom of the casing accommodates multiple mounting options. The 200350 and Accelerometers contain a piezoelectric sensing device, which generates charge when subjected to vibration. This charge is then converted electronically to a differential voltage signal, which is proportional to the acceleration that is parallel to the sensitive axis of the transducer. Caution If housing measurements are being made for overall protection of the machine, consider the usefulness of the measurement for each application. Most common machine malfunctions (imbalance, misalignment, etc.) originate at the rotor and cause an increase (or at least a change) in rotor vibration. For housing measurements alone to be effective for overall machine protection, a significant amount of rotor vibration must be faithfully transmitted to the bearing housing or machine casing, or more specifically, to the mounting location of the transducer. In addition, exercise care in the physical installation of the transducer. Improper installation can result in a degradation of the transducer s performance and/or the generation of signals which do not represent actual machine vibration. Upon request, Bently Nevada can provide engineering services to determine the suitability of housing measurements for the machine in question and/or to provide installation assistance. BN Part Number 164804-01 Page 1 of 11

SPECIFICATIONS Parameters are specified from +20 to +30 C (+68 to +86 F) and 100 Hz unless otherwise indicated. Electrical Alert Operation outside the specified limits will result in false readings or loss of machine monitoring. Specification English Units SI Units Sensitivity 200350 (± 20%) (± 5%) Frequency Range 200350 (± 3dB) (± 3dB) 100 mv/g 100 mv/g 30 to 600,000 cpm 12 to 600,000 cpm 10.2 mv/(m/s 2 ) 10.2 mv/(m/s 2 ) 0.5 to 10,000 Hz 0.2 to 10,000 Hz Temperature Sensitivity See Graph See Graph Measurement Range ± 50 g ± 490 m/s 2 Transverse Sensitivity 200350 7% 5% 7% 5% Amplitude Linearity ± 1% ± 1% Mounted Resonant Frequency 200350 Broadband Electrical Noise (1-10kHz) 200350 1500 kcpm 1250 kcpm 350 µg 50 µg 25 khz 20.8 khz 3434 µm/s 2 491 µm/s 2 Output Bias Voltage 8 to 12 VDC 8 to 12 VDC Excitation Voltage 18 to 28 VDC 18 to 28 VDC Constant Current Excitation 2 to 20 ma 2 to 20 ma Settling Time (within 1% of bias) 200350 Output Impedance 200350 Discharge Time Constant 200350 2.0 sec 5.0 sec < 150 ohms < 100 ohms 0.3 sec 0.8 sec 2.0 sec 5.0 sec < 150 ohms < 100 ohms 0.3 sec 0.8 sec Electrical Isolation (Case) > 10 8 ohms > 10 8 ohms BN Part Number 164804-01 Page 2 of 11

Environmental Specification English Units SI Units Operating Temperature Range -65 to +250 ºF -54 to +121 ºC Shock Survivability 5,000 g pk 49,050 m/s 2 pk Relative Humidity 100% relative, condensing, non-submerged Enclosure Rating IP68 IP68 Physical Specification English Units SI Units Size (Hex * Height) 200350 Weight 200350 11/16 in * 1.65 in 7/8in * 2.06in 1.8 oz 3.3 oz 18 mm * 42.2 mm 22mm * 52.3mm 51 gm 94 gm Mounting Thread ¼-28 Female ¼-28 Female Mounting Torque (Max) 2 to 5 ft*lb 2.7 to 6.8 N*m Sensing Element Ceramic Ceramic Sensing Geometry Shear Shear Housing Material Stainless Steel Stainless Steel Sealing Welded Hermetic Welded Hermetic Electrical Connector 2-Pin Mil-C-5015 2-Pin Mil-C-5015 Electrical Connection Position Top Top BN Part Number 164804-01 Page 3 of 11

HAZARDOUS AREA APPROVALS **Note: The does not have hazardous area approvals at this time. 200350 CSA/NRTL/C: Class I, Div 1, Groups A, B, C, D Class I, Div 2, Groups A, B, C, D Ex ia IIC T4; Class I, Zone 0 Ex nl IIC T4; Class I, Zone 2 EMC DIRECTIVE (CE MARK) Standards to which Conformity is Declared CISPR 11 / EN 55011 Emissions: Class B, Group 1 EN61326 / A1 Emissions: Industrial Location EN61326 / A1 Immunity: Industrial Location BN Part Number 164804-01 Page 4 of 11

ORDERING OPTIONS 200350 AA BB CC AA Mounting Stud 0 0 1/4-28 SS w/brass tip, 0.5 in 0 1 1/4-28 to M6 x 1.0 BeCu 0 2 1/4-28 to M8X1.25 BeCu 1 0 1/4-28 Adhesive Stud Mount 1 1 M6X1 Adhesive Stud Mount 1 2 M8X1.25 Adhesive Stud Mount BB Tolerance Option 0 0 100 mv/g +/- 20 % CC Approvals Option 0 0 No Approvals 0 1 CSA/NRTL/C Approvals AA BB CC AA Mounting Stud 0 0 1/4-28 SS w/brass tip, 0.5 in 0 1 1/4-28 to M6 x 1.0 BeCu 0 2 1/4-28 to M8X1.25 BeCu 1 0 1/4-28 Adhesive Stud Mount 1 1 M6X1 Adhesive Stud Mount 1 2 M8X1.25 Adhesive Stud Mount BB Tolerance Option 0 2 100 mv/g +/- 5 % CC Approvals Option 0 0 No Approvals BN Part Number 164804-01 Page 5 of 11

ACCESSORIES Title Part Number Notes 200350 and Accelerometer 164803-01 Manual Trendmaster Pro System Manual 162411 Trendmaster DSM Datasheet 149831-01 Trendmaster DSM Manual 149823-01 M6X1 Mount Stud 164372 ¼ - 28 Mount Stud 164373 M8X1.25 Mount Stud 167559 ¼-28 Adhesive Mount Kit 167563-10 See Description Below M6X1 Adhesive Mount Kit 167563-11 See Description Below M8X1.25 Adhesive Mount Kit 167563-12 See Description Below Splash Proof Cable **Not recommended for the 200350 CB2W100 AAA AAA = 015 ft AAA = 125 ft AAA = 032 ft AAA = 150 ft AAA = 064 ft AAA = 200 ft AAA = 112 ft BN Part Number 164804-01 Page 6 of 11

Standard Cable No Armor 2-conductor twisted, shielded 22 AWG cable with 2-socket moisture-resistant female connector at one end, terminal lugs at the other end. Standard Cable with Armor 2-conductor twisted, shielded 22 AWG cable with 2-socket moisture-resistant female connector at one end, terminal lugs at the other end. 9571 AA Minimum Length - AA = 02 ft Maximum Length - AA = 99 ft Increments of 01 ft 84661 AA Minimum Length - AA = 03 ft Maximum Length - AA = 96 ft Increments of 01 ft Adhesive Mounting Kits Adhesive studs are sold in kits containing two threaded studs and two mounting pads. Also in the kit is a packet of acrylic adhesive and materials to mix its two components. A scouring pad and alcohol wipe are provided for preparing the mounting surface. Adhesive Specification English Units SI Units Temperature Range -67 to +250 ºF -55 to 121 ºC Cure Time 24 Hour 24 Hour Application Alert Use of adhesive will attenuate high frequency components that may be present. BN Part Number 164804-01 Page 7 of 11

DIMENSIONAL DIAGRAM 200350 BN Part Number 164804-01 Page 8 of 11

BN Part Number 164804-01 Page 9 of 11

TEMPERATURE SENSITIVITY CURVE FREQUENCY AND PHASE RESPONSE CURVES 200350 Frequency Response db 1 0-1 -2-3 0.1 1 10 100 1000 10000 Hz Phase Phase Angle 100 50 0-50 -100 0.1 1 10 100 1000 10000 Hz BN Part Number 164804-01 Page 10 of 11

Frequency Response 1 0 db -1-2 -3 0.1 1 10 100 1000 10000 Hz Phase 100 Phase Angle (deg) 50 0-50 -100 0.1 1 10 100 1000 10000 Hz 2003 Bently Nevada, LLC Trendmaster is a registered mark of Bently Nevada, LLC CSA is a registered mark of CSA-International BN Part Number 164804-01 Page 11 of 11