and Accelerometers

Similar documents
and Accelerometers Bently Nevada* Asset Condition Monitoring

Caution. Description. Specifications and Ordering Information and Accelerometers

200150, & Accelerometers Bently Nevada* Asset Condition Monitoring

Hydro Stator End Winding Accelerometer System

Hydro Stator End Winding Accelerometer System

PPT 802, Proximity Probe Transducer System

Proximity Transducers, Seismic Sensors and Accessories

Part Number Revision NC, September High Temperature Velocity and Acceleration Sensor Operation and Maintenance Manual

Industrial Monitoring Instrumentation

3300 XL High-Pressure Feedthrough

Type 2REX-A. Oil & Gas / Heavy Industry

Proximity Transmitters, and Seismic Vibration Transmitters

Ø 68 mm to ø 115 mm. Material: Weight: Shaft Loads: Enclosure Rating: Connection Options. Cable: Cable Glands:

Ø 68 mm to ø 115 mm. Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating:

Operation Manual Bently Nevada Asset Condition Monitoring

Material: Weight: Shaft Loads: Enclosure Rating: Cable: Cable Glands:

Fisher i2p 100 Electro Pneumatic Transducer

Monitor and Transducer Verification Kits

MODEL 205 ce VIBRATION METER

Proximity Transmitters, and Seismic Vibration Transmitters

Seismic Sensor Accessories SA, SV & ST 6000 Series

TX5634 to TX5639 Data Sheet

Installation Manual A Digital Tachometer. Part Number Rev. H (09/07)

FM Approved Remote Kit Assembly (Part No ) Standard Remote Kit Assembly (Part No ) G2 SERIES G2 Industrial METER MODULES

Railway vibration measurement. Enhance safety and cut maintenance costs

Model 648A ma Output Accelerometer. Installation and Operating Manual

Fisher 3710 and 3720 Positioners and 3722 Electro Pneumatic Converter

Описание на системы датчиков воздушного зазора. Модель 4000

Fisher 3660 and 3661 Positioners

Product Manual MNX10003 / REV C MODEL MH130 MODEL MH101-1B MODEL MH107-1B / MH107-1A MODEL MH118

Acceleration Sensor AS - 030

Sensors for Road Load Measurements Accelerometers, Pressure Sensors, Force Sensors, Strain Sensors, Load Cells, and Signal Conditioners

Instruction Manual. Vibration Severity Meter VM12

Product Manual MNX10003 / REV B MODEL MH130 MODEL MH101-1B MODEL MH107-1B / MH107-1A MODEL MH118

RK 4 Rotor Kit. Description

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

Fisher 3710 and 3720 Positioners and 3722 Electro Pneumatic Converter

GETTING STARTED GUIDE NI AI, ±10 V, 16 Bit, 1 MS/s/ch Simultaneous

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

PXT-K Series. Pressure Transmitters Section 05

Models 4700P/4700E & 4800P/4800E

Series Level-Trol Electronic Liquid Level Transmitters

Eddy Probe Systems Catalog. Probes and drivers Mounting devices Housings Pressure feedthroughs Calibrators and simulators Accessories

Product specification

FasTrak High Capacity Smart Positioner

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

Mobrey MSM400 Ultrasonic sludge density measurement system

Load and Motor Switches, Load-Break Switches Series 8544

Paddle-wheel flow controller for On/Off control

Temposonics. Magnetostrictive Linear Position Sensors. TH Analog SIL 2 capable Data Sheet

Sentronic PLUS 614 Series

GETTING STARTED GUIDE NI AI, 51.2 ks/s/ch Simultaneous, Universal Measurements

Acceleration sensors (ICP technology) VBS 50 overview Configurations

Model 643A ma Output Velocity Sensor. Installation and Operating Manual

VIBRATION SENSORS VIBRATION SENSORS

Product specification

GETTING STARTED GUIDE NI DO, 5 V to 30 V, Sourcing, 1 μs

GETTING STARTED GUIDE NI DO, 6 V to 30 V, Sourcing, 100 μs

GETTING STARTED GUIDE NI AO, ±10 V, 16 Bit, 25 ks/s/ch Simultaneous

HCA & HCA-RA SERIES Hermetically Sealed AC LVDT

AST44LP Intrinsically Safe Low Pressure Transducers / Transmitters

797V Piezoelectric Velocity Sensor

HX-P420 SERIES 4 to 20 ma OUTPUT

Type Type 1001 Transducers. I/P & E/P Transducers

Electropneumatic positioner APIS

TZIM. Electropneumatic Analog Positioner 10/ EN

Product specification

Fisher 546 Electro Pneumatic Transducer

Type Type I/P & E/P Transducers

Continuous Duty Torque Measurement. Directly and accurately measures the power of turbomachinery in the Oil, Gas and Petrochemical industries.

Miniature I/P, E/P Transducer

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Fisher 646 Electro Pneumatic Transducer

LTX RF LEVEL SENSOR. Instruction Manual

Weatherproof Tubular Slip Ring Assembly

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

SL Series Application Notes. SL Series - Application Notes. General Application Notes. Wire Gage & Distance to Load

Fisher 3610J and 3620J Positioners and 3622 Electro Pneumatic Converter

2100 Turbine Flow Sensor

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Magnetic-inductive flow meter for hazardous areas

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX )

Load and Motor Switches, Load-Break Switches Series 8549

FAIRCHILD T8001 SERIES STANDARD RANGE MINIATURE TWO-WIRE, P/I PRESSURE TRANSDUCER. Installation, Operation and Maintenance Instructions

MS Application. Features. Proportional Valve Actuator General Instructions

GETTING STARTED GUIDE NI AI Differential/32 AI Single-Ended, ±200 mv to ±10 V, 16 Bit, 250 ks/s Aggregate

GETTING STARTED GUIDE NI AI/1 Neutral, 400 Vrms L-N/690 Vrms L-L, 24 Bit, 50 ks/s/ch Simultaneous

APG. Explosion Proof and Non-Incendive Magnetostrictive Level Sensors Series: MPX. Features

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

ISO: 16 V/mm (406.4 mv/mil) ± temperature range 0 to 45 C (+32 to +113 temperature range 0 to 45 C (+32 to +113 F)

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

Safety Standards. Model Number:

0745A Load Cell. Global Usage Fully Approved for Accuracy and Safety. 0745A Beam Load Cell Fully Approved

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

REMOTE MOUNT SOLENOID DRIVER (0-5 VDC/0-20 ma/10k Potentiometer Input)

TRC ELECTRONICS, INC DC/DC Converter SIP Package 6W MEAN WELL SPBW06 & DPBW06 Series

Paddle-wheel flow controller with optical principle for On/Off control

Transcription:

200350 and 200355 Accelerometers Product Datasheet Bently Nevada* Asset Condition Monitoring Description The 200350 and 200355 Accelerometers are general purpose, casemounted seismic transducers designed for use with Trendmaster* Pro Constant Current Direct Input Card, part number 149811-02 and the Seismic Direct Input Card, part number 164746-01. The 200350 and 200355 Accelerometers are contained within a hermetically sealed, stainless steel case. The design provides an extremely rugged transducer, well suited for harsh industrial environments. Each transducer s top mounted, 2-pin connector (MIL- C-5015) allows for easy installation and removal of the interconnecting signal cable. A ¼-28 threaded hole on the bottom of the casing accommodates multiple mounting options. The 200350 and 200355 Accelerometers contain a piezoelectric sensing device, which generates charge when subjected to vibration. This charge is then converted electronically to a differential voltage signal, which is proportional to the acceleration that is parallel to the sensitive axis of the transducer. NOTE If housing measurements are being made for overall protection of the machine, consider the usefulness of the measurement for each application. Most common machine malfunctions (imbalance, misalignment, etc.) originate at the rotor and cause an increase (or at least a change) in rotor vibration. For housing measurements alone to be effective for overall machine protection, a significant amount of rotor vibration must be faithfully transmitted to the bearing housing or machine casing, or more specifically, to the mounting location of the transducer. In addition, exercise care in the physical installation of the transducer. Improper installation can result in a degradation of the transducer s performance and/or the generation of signals that do not represent actual machine vibration. Upon request, we can provide engineering services to determine the suitability of housing measurements for the machine in question and/or to provide installation. Page 1 of 13

Specifications Parameters are specified from +20 to +30 C (+68 to +86 F) and 100 Hz unless otherwise indicated. CAUTION Operation outside the specified limits will result in false readings or loss of machine monitoring. Electrical Isolation (Case) Environmental Operating Temperature Range Shock Survivability Relative Humidity Enclosure Rating > 10 8 ohms -65 to +250 ºF (-54 to +121 ºC) 5,000 g pk 100% relative, condensing, nonsubmerged IP68 Physical NOTE Do not use sensor p/n 200350 for negative excitation voltage (-Vex). Electrical Sensitivity 100 mv/g ±20% (10.2 mv/m/s^2 ±20%) Frequency Range (±3 db) Measurement Range 200350 200355 30-600,000 cpm (0.5-10,000 Hz) ± 50 g 100 mv/g ±5% (10.2 mv/m/s^2 ±5%) 12-600,000 cpm (0.2-10,000 Hz) Transverse Sensitivity 7% 5% Amplitude Linearity ± 1% Mounted Resonant Frequency Broadband Electrical Noise (1-10kHz) 1500 kcpm (25 khz) 350 µg (3,434 µm/s 2 ) 1250 kcpm (20.8 khz) 50 µg (491 µm/s 2 ) Hex Size 11/16 (18 mm) Height 1.65 (42.4 mm) Weight Mounting Thread Mounting Torque (Maximum) Sensing Element Sensing Geometry Housing Material Sealing Electrical Connector Electrical Connection Position 200350 200355 1.8 oz (51 grams) 7/8 (22mm) 2.06 (52.3 mm) 3.3 oz (94 grams) 1/4-28 Female 2 to 5 ft-lb (2.7 to 6.8 N-m) Ceramic Shear Stainless Steel Welded Hermetic 2-Pin Mil-C-5015 Top Output Bias Voltage Excitation Voltage Constant Current Excitation Settling Time (within 1% of bias) 2.0 sec 8 to 12 VDC 18 to 28 VDC 2 to 20 ma 5.0 sec Output Impedance < 150 ohms < 100 ohms Discharge Time Constant 0.3 sec 0.8 sec Page 2 of 13

Hazardous Area Approvals For a detailed listing of country and product specific approvals, refer to the Approvals Quick Reference Guide, Document 108M1756, at www.gemeasurement.com. 200350 Accelerometer Compliance and Certifications Electromagnetic Compatibility (EMC) Standards EN 61326-1:2013 Directives EMC Directive 2014/30/EU CSA/NRTL/C (Approval Option 01) Ex ia IIC T4 Class I, Division 1, Groups A, B, C and D Intrinsically Safe AEx ia IIC T4 Class I, Division 1, Groups A, B, C and D T4 @ -54 C Ta +121 C (-65.2 F Ta 249.8 F ) per drawing 175825 Ex nl IIC T4 Class I, Division 2, Groups A, B, C and D Intrinsically Safe and Non-Incendive AEx na T4 Class I, Division 2, Groups A, B, C and D T4 @ -54 C Ta +121 C (-65.2 F Ta +249.8 F ) per drawing 175825 ATEX/IECEx (Approval Option 01) II 1 G Ex ia IIC T4 Ga II 3 G Ex na IIC T4 Gc T4 @ -54 C Ta +121 C (-65.2 F Ta +249.8 F) 200355 Accelerometer The 200355 accelerometer does not have hazardous area approvals at this time. Page 3 of 13

Accessories 200350 and 200355 Accelerometer Manual 168303-01 Trendmaster* Pro System Manual 162411 Trendmaster DSM Datasheet 149831-01 Trendmaster DSM Manual 149823-01 Mounting Studs Dimensional diagrams of all available mounting studs are shown in See "Graphs and Figures" on page 7. ¼-28 Mounting Stud 164373 M6x1 Mounting Stud 164372 M8X1.25 Mounting Stud 167559 Adhesive Mounting Kits Adhesive studs are sold in kits containing two threaded studs and two mounting pads. Also in the kit is a packet of acrylic adhesive and materials to mix its two components. A scouring pad and alcohol wipe are provided for preparing the mounting surface. Temperature Range: -67 to +250 ºF (- 55 to 121 ºC) Cure Time: 24 hours NOTE Use of adhesive will attenuate high frequency components that may be present. ¼-28 Adhesive Mounting Kit 167563-10 M6x1 Adhesive Mounting Kit 167563-11 M8X1.25 Adhesive Mounting Kit 167563-12 Magnetic Base Kit The magnetic base has a pull of 35 lbf and it is suitable for placement on both curved surfaces and flat surfaces. The magnet comes supplied with a ¼-28 mounting stud. A dimensional diagram of the magnetic base is shown in See "Graphs and Figures" on page 7. Magnetic Base w/ Mounting Stud Cables 286244 The Splash proof cable is not recommended for the model 200350 accelerometer. The standard cables are 22 AWG 2-conductor twisted shielded pairs with 2-socket moistureresistant female connector at one end, terminal lugs at the other end. Cable length is optional and comes in increments of 1 ft between the stated maximum and minimum lengths. Splash Proof Cable CB2W100 AXXX A: Length 0 1 5 15 ft 0 3 2 32 ft Page 4 of 13

0 6 4 64 ft 1 1 2 112 ft 1 2 5 125 ft 1 5 0 150 ft 2 0 0 200 ft 2 5 0 250 ft Standard Cable, No Armor 9571 AXX A: Length 0 2 Minimum length, 2 ft 9 9 Maximum length, 99 ft X X Desired length in ft The following are standard lengths Feet Metres (approx.) 6 1.8 8 2.4 10 3.0 12 3.6 15 4.5 17 5.0 20 6.0 25 7.6 30 9.0 33 10.0 50 15.2 99 30.0 Note: Non-standard/custom lengths can also be ordered at additional cost X X Desired length in ft The following are standard lengths Feet Metres (approx.) 6 1.8 8 2.4 10 3.0 12 3.6 15 4.5 17 5.0 20 6.0 25 7.6 30 9.0 33 10.0 50 15.2 99 30.0 Note: Non-standard/custom lengths can also be ordered at additional cost Standard Cable, Armored 84661 AXX A: Length 0 3 Minimum length, 3 ft 9 9 Maximum length, 99 ft Page 5 of 13

Ordering Information For a detailed listing of country and product specific approvals, refer to the Approvals Quick Reference Guide, document 108M1756, at www.gemeasurement.com. 200350 Accelerometer 200350 AXX BXX - CXX A: Mounting Stud 0 0 ¼-28 SS w/ Brass tip, 0.5 0 1 ¼-28 to M6 x 1.00 BeCu 0 2 ¼-28 to M8 x 1.25 BeCu 0 9 No mounting stud 1 0 ¼-28 Adhesive Stud Mount 1 1 M6x1 Adhesive Stud Mount 0.5 0 1 ¼-28 to M6 x 1.00 BeCu 0 2 ¼-28 to M8 x 1.25 BeCu 0 9 No mounting stud 1 0 ¼-28 Adhesive Stud Mount 1 1 M6x1 Adhesive Stud Mount 1 2 M8x1.25 Adhesive Stud Mount 1 3 Magnetic Base Kit B: Tolerance 0 0 100 mv/g ± 5% (10.2 mv/m/s^2 ±5%) C: Approvals 0 0 No approvals 1 2 M8x1.25 Adhesive Stud Mount 1 3 Magnetic Base Kit B: Tolerance 0 0 100 mv/g ± 20% (10.2 mv/m/s^2 ±20%) C: Approvals 0 0 No approvals 0 1 CSA, ATEX, IECEx 200355 Accelerometer 200355 AXX BXX - CXX A: Mounting Stud 0 0 ¼-28 SS w/ Brass tip, Page 6 of 13

Graphs and Figures Figure 1: 200350 Accelerometer Dimensional Drawing Page 7 of 13

Figure 2: 200355 Accelerometer Dimensional Drawing Page 8 of 13

Figure 3: 200350 Accelerometer Frequency Response Figure 4: 200350 Accelerometer Phase Figure 5: 200355 Accelerometer Frequency Response Page 9 of 13

Figure 6: 200355 Accelerometer Phase Figure 7: Temperature Sensitivity Curve Page 10 of 13

¼-28 Stud M6x1 Stud M8x1.25 Stud Figure 8: Mounting Stud Dimensional Drawings Page 11 of 13

Figure 9: Magnetic Base Dimensional Drawing Page 12 of 13

Copyright 2003-2018 Baker Hughes, a GE company, LLC ("BHGE") All rights reserved. * Denotes a trademark of Bently Nevada, LLC, a wholly owned subsidiary of Baker Hughes, a GE company. All product and company names are trademarks of their respective holders. Use of the trademarks does not imply any affiliation with or endorsement by the respective holders. The information contained in this document is subject to change without prior notice. 1631 Bently Parkway South, Minden, Nevada USA 89423 Phone: 1-775.782.3611 www.gemeasurement.com Page 13 of 13