Thermal-Magnetic Circuit Breaker M1-...

Similar documents
Thermal Overcurrent Circuit Breaker 3120-F...

Thermal-Magnetic Circuit Breaker M1-..

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3130

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3130

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Thermal Overcurrent Circuit Breaker 3130

Thermal Circuit Breaker 3120-F...

Thermal Circuit Breaker / Switch Series 3131

Thermal Circuit Breaker / Switch Series 3131

N W. Thermal Circuit Breaker / Switch Series Description. Typical applications Circuit breaker. Technical data

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

High Performance Thermal Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker

Thermal Circuit Breaker / Switch Series 3131

Magnetic and Hydraulic-Magnetic Circuit Breaker

Thermal-Magnetic Circuit Breaker 201/-WA

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic Overcurrent Circuit Breaker

High Performance Thermal-Magnetic Circuit Breakers 410/520/

Simulator switch, magnetic operation

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20

Electronic circuit breaker EBU10-T

Thermal-magnetic Miniature Circuit Breaker 4230-T...

circuit breakers circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole Description Applications

TM12 Series CIRCUIT BREAKERS FOR EQUIPMENT. Thermal magnetic release Positively trip-free Reset or manual actuation

TMC 91H is now TMC 60 C Series

circuit breakers circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole Description Applications TeChniCAl DATA

circuit breakers circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole Description Applications TECHNICAL DATA

circuit breakers circuit breakers Thermal Circuit Breaker, rotary knob actuation, 1-, 2- or 3-pole Description Applications

CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON

Circuit Breakers. DIN rail-mounted equipment protection

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

UMBW-UL489 and UL1077 Listed

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

EXCEL CELL ELECTRONIC CO., LTD. NO. A S P E C I F I C A T I O N Edition 2 Page 1

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

PB-Series. GFCI/ELCI & Panel Seal

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

1489-M Circuit Breakers

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

DD Frame - Series Circuit Breakers

BETA Switching Switches and Light Indicators

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Phase + Neutral, neutral on left side

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

SIRIUS 3RU2 Thermal Overload Relays

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

cor Long Run Experience

Phase + Neutral, neutral on right side

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

FL series position switches

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

PD-Series Ground Fault Circuit Protection

LK Position Switches TECHNICAL DATASHEET.

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB

Essential equipment for all your requirements

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

1492-CB 1492-GH 1492-GS

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

Selection Guide. Control Circuit and Load Protection

Safety rope switches with reset for emergency stop

DX³ 4-pole RCBO 6000 A/10 ka

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Control Circuit Protection

General_technical_data Series

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

Protection components

Special Purpose Fuses

3VU13, 3VU16 Circuit-Breakers

Standard Interlock Safety Switches

Semiconductor Fuses Microswitches & Studs

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1

AR circuit breaker - Hydraulic magnetic,

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Solenoid Locking Safety Switches

Standard Interlock Safety Switches

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Technical data. Miniature Circuit Breakers. System pro M. System pro M

Miniaturized limit switches

Transcription:

Thermal-Magnetic Circuit Breaker 320-...-M-... Description Two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 6034). The addition of a magnetic tripping module to the type 320 range described in catalogue section Thermal Overcurrent Circuit Breakers extends the choices available (thermal-magnetic protection in pole, thermal or no protection in pole 2). All are offered with rocker switch or push button control - two buttons for ON/OFF or one button press-to-reset only, in designs to suit one of three different panel cut-out sizes. Illumination is optional. Approved to CBE standard EN 6034 (IEC 6034). Meets the requirements regarding fire resistance of EN 605-: 2007-02 Safety of household and similar electrical appliances. Typical applications 320-...-M... Motors, machine tools, office equipment, appliances. Standard current ratings and typical internal resistance values Current ratings (A) Internal resistance per pole (Ω) thermal-magnetic thermal 0. 65 4 0.2 42.5 24 0.3 20.2 2 0.4.7 5.40 0.5 7.7 4. 0.6 4. 3 0.8 2.65.50.4 0..2. 0.7.5 0.74 0.45 2 0.4 0.2 2.5 0.20 0.0785 3 0.4 0.055 0.4 0.0565 4 0.02 0.04 5 0.06 0.03 6 0.043 0.0 7 0.0 0.0 8 0.02 0.02 0 0.02 0.02 2 < 0.02 < 0.02 4 < 0.02 < 0.02 5 < 0.02 < 0.02 6 < 0.02 < 0.02 Technical data For further details please see chapter: Technical Information Voltage rating AC 240 V (50/60 Hz); DC 50 V Current ratings 0...6 A Typical life 0...6 A 50,000 operations at x I N, ind. Ambient temperature -...+60 C (-22...+40 F) Insulation co-ordination rated impulse pollution (IEC 60664 and 60664 A) withstand voltage degree 2.5 kv 2 reinforced insulation in operating area Dielectric strength (IEC 60664 and 60664A) test voltage operating area AC 3,000 V current path/current path AC,500 V Insulation resistance > 00 MΩ (DC 500 V) Interrupting capacity I cn AC 0...2 A 00 x I N AC 2.5...6 A 0 A DC 0...6 A 0 x I N Interrupting capacity (UL 077) Degree of protection (IEC 6052/DIN 40050) Vibration Shock Corrosion Humidity Mass I N U N I nc 0...0 A AC 0 V 2,000 A 0...6 A DC V,000 A operating area IP40 (with water splash protection IP) terminal area IP00 8 g (57-500 Hz) ± 0.6 mm (0-57 Hz) to IEC 60068-2-6, test Fc 0 frequency cycles/axis g ( ms) to IEC 60068-2-27, test Ea 6 hours at 5 % salt mist to IEC 60068-2-, test Ka 240 hours at 5 % RH to IEC 60068-2-78, test Cab approx. 53 g (2-pole) approx. 50 g (-pole) Illumination voltage / Power consumption Operating voltage Power consumption Y R G 2 V 2.2 ma 0. ma 0. ma 646 www.e-t-a.de

Thermal-Magnetic Circuit Breaker 320-...-M-... Ordering information 320 with rocker switch Type 320 thermal-magnetic circuit breaker Mounting F snap-in frame Size of frame 3 Standard, to fit in cut-out 50.5 x 2.5 mm panel thickness - 6. mm (.03-.0 in) 5 Standard, to fit in cut-out 44.5 x 22 mm panel thickness - 4 mm (.03-.57 in) 7 Design, to fit in cut-out 45 x 22 mm panel thickness - 4 mm (.03-.57 in) Number of poles 2 2-pole switching and 2-pole protected (pole : thermalmagnetically protected, pole 2: thermally protected) 5 2-pole switching and pole thermal-magnetically protected Mounting frame design collar height mm (.03 in) 3 collar height mm ( in) 4 collar height 2 mm (.07 in) with water splash protection (IP) Mounting frame design (F7) R black T black with snap-on splash cover Terminal configuration P7 all 4 terminals 2(k), 22(k),, 2 blade terminals 2x2.8-0.8 H7 2(k), 22 (k): blade terminals 2x2.8-0.8, 2: terminal screws M, blade terminals 2x2.8-0.8 G7 as H7, but terminals 2(i) and 22(i) are blade terminals 2x2.8-0.8 (shunt terminal) Characteristic curve M standard delay, therm..0-.4 x I N ; magn. 4- x I N AC Switch style W standard rocker (F3 & F5) A specially designed rocker (F7) Colour and illumintation 0. rocker black opaque 02. rocker white opaque 04. rocker red opaque 4. R rocker red translucent with LED-illumination 5. Y rocker orange translucent with LED-illumination. G rocker green translucent with LED-illumination Rocker markings for F3 and F5 A D F Q X Q Rocker markings for F7 I«and»O«moulded in Illumination voltage range 0-4 V DC 2 20-28 V DC 3 0-40 V AC 4 85-275 V AC Current ratings 0,...6 A 320 -F 3 2 - P7 M-W 4 A R 4-0 A ordering example The exact part number required can be built up from the table of choices shown above. Ordering references for optional features should be omitted if not required. 0 I I 0 ON OFF A D F X Q: as D, but moulded in X: Ordering information 320 with push buttons Type 320 thermal-magnetic circuit breaker Mounting F snap-in frame Size of frame 3 to fit in cut-out 50.5 x 2.5 mm panel thickness - 6. mm Number of poles 2 2-pole switching and 2-pole protected (pole : thermalmagnetically protected, pole 2: thermally protected) 5 2-pole switching and pole thermal-magnetically protected Mounting frame design F frame with two push buttons G frame with one push button Terminal configuration P7 all 4 terminals 2(k), 22(k),, 2 blade terminals 2x2.8-0.8 H7 2(k), 22 (k): blade terminals 2x2.8-0.8, 2: terminal screws M, blade terminals 2x2.8-0.8 Characteristic curve M standard delay, therm..0-.4 x I N ; magn. 4- x I N AC Actuator style / colour / illumination D 0X push button* black opaque D 02X push button* white opaque D 04X push button* red opaque D XG push button* green translucent with LED-illumination SGRX 2 push buttons green/red opaque SGRXG 2 push buttons green/red translucent with LED-illumination Illumination voltage range 0-4 V DC 2 20-28 V DC 3 0-40 V AC 4 85-275 V AC Current ratings 0...6 A 320 -F 3 2 F - P7 M - SGRXG 4-0 A ordering example *Reset only Other push button colours upon request Approvals Authority Standard Rated voltage Current ratings VDE IEC / EN 6034 AC 240 V DC 50 V UL UL 077 AC 0 V AC V CSA C22.2 No 2 AC 0 V DC V CQC (CCC) GB 770 AC 240 V DC 50 V 0...6 A 0...6 A 0...0 A 0...6 A 0...0 A 0...4 A 0...6 A 0...6 A 2 www.e-t-a.de 646

Thermal-Magnetic Circuit Breaker 320-...-M-... Dimensions Dimensions Mounting style -F7.R Mounting style -F3., with rocker Collar height mm 8...0 5.5.60.38 2 blade terminals DIN 46244-C-Ms-S (QC 2 x.0) flat head screw ISO580 Mx5-MS tightening torque max. 0.8 Nm Mounting style -F7.T LINE 2(i) 2(k) 5.5.60 48 ±0.2.8 ±.008 44.2-0.2.74 -.008 8.70 4.6 3 0 4.55.8.8 7.276.38. flat-head screw Mx5 ISO 580 tightening torque max. 0.8 Nm blade terminals DIN 46244-C-Ms-S (QC 2 x.0) 6.6 Installation drawing OFF position.38 5.5.60 optional illumination in ON position 2.3 2 8.70 4.55 4.6 0.8 34.34 8.6.732 60 2.36 44.8.76 When installing the circuit breaker apply pressure on bezel only. operating area. 5.5.60 0 Required safety distances for rocker and push button 0..5.453 LINE 2(i) 2(k) Cut-out dimensions.38 2 blade terminals DIN 46244-C-Ms-S (QC 2 x.0) flat head screw ISO580 Mx5-MS tightening torque max. 0.8 Nm 5.5.60 8.70 4.6 4.55.8 7 7.276.276 mounting area 8. Internal connection diagrams therm.-magn. protection on one pole thermally protected on the other pole line 2 7 0.276 therm.-magn. protection on one pole unprotected on the other pole line 2 Cut-out for mounting style -F3 with rocker and push button -6..03-.0 2.5 +0.2.846 +.008-0.4 -.06-0.2 -.008 max. R2 max.07 ±0.05 ±.002 50.5 +0.3. +.02 min. 2.5 min.08 max. R0.3 max.02 Cut-out for mounting style -F5 with rocker -4 mm.03-.57 in. max. R0.3 max.02-0.4 -.06-0.2 -.008 max. R.5 max.05 ±0.05 ±.002 44.5 +0.2.75 +.008 min. 2 min.07 22 +0.3.866 +.02 Edges of working parts: ISO 375 2(i) 2(k) I > 2 22(i) 22(k) 2(i) 2(k) I > 2 22(i) This is a metric design and millimeter dimensions take precedence ( mm ) inch 646 www.e-t-a.de 3

Thermal-Magnetic Circuit Breaker 320-...-M-... Mounting frame variants Typical time/current characteristics at +23 C/+73.4 F Mounting style F3.3 with rocker collar height mm ( in.) Single or double pole load 0. 2 A AC/DC ).5.768 2.3.38 0000 000 flat-head screw Mx5 ISO 580 (H7 / G7) tightening torque max.0.8 Nm blade terminal DIN 46244-C-Ms-S (QC 2x.0).38 5.5.60 2 8.70 4.55 4.6 Trip time in seconds 00 0 0. 0.0 0.00 2 4 6 80 20 40 60 8000 times rated current 27.06.5.768 56 2.2.38 2.5 6 A AC/DC ) 0000 000 Trip time in seconds 00 0 0. 6.2.638 optional illumination in ON position OFF position 2.3 4.2.55 0.0 0.00 2 4 6 80 20 40 60 8000 times rated current ) Magnetic tripping currents are increased by % on DC supplies. 6.2.638 optional illumination in ON position OFF position 2.3 4.2.55 The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section Technical information. Ambient F temperature C -22 - -4-20 +4-0 +32 0 +73.4 +23 +04 +40 +22 +50 +40 +60 Derating factor 0.8 0.76 0.84 0.2.08.6.24 0 5.5.38. 0.8 Mounting style F3.4 with rocker collar height 2 mm (.07 in.), with water splash protection 0 3.8.50 Mounting style F3.F- -S- with 2 push buttons 5.5 0 Mounting style F3.G- -D- with push button For mounting styles -F2.., -F5.., -F6.. please see section Thermal Overcurrent Circuit Breakers. 4 www.e-t-a.de 646

Thermal-Magnetic Circuit Breaker 320-...-M-... Accessories Insulated cover Y 3 068 0 2.5.08 20.787 Spacer for 320-F3... Y 3 675 0/02 58 2.28 50.5. Spacer for 320-F5... Y 3 676 0 52 2.05 44.5.75.03 48.8.38 6.5.650 0..0 22.866 28.0 22.5.886 28.0 *.03 sharp-edged 3.4.34 0.8.03 without bends 2.5.08 * Y 3 675 0 suitable for panel thickness < 2 mm (.07 in) * Y 3 675 02 suitable for panel thickness < 4 mm (.57 in) Blanking piece in -F3 size mounting frame Y 3 885 3.03 2.3 3.22 matt finish 6.5.650. 36.42 4.6 2 Separate water splash cover, transparent (IP66) for use with -F5.. size mounting frames X 22 6 0 ø8. ø4.4.73 60 2.36 73 2.87 This is a metric design and millimeter dimensions take precedence ( mm ) inch All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.product markings may not be exactly as the ordering codes. Errors and omissions excepted. 646 www.e-t-a.de 5

6 www.e-t-a.de 646