DIESEL GENSET. Prime Hz 16 kw / 20 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Similar documents
TM20UCM MODEL. Standard Features. Generator Ratings. Conditions of sale. Prime Hz 18 kw / 18 kva. General features :

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime 60Hz 36 kw / 45 kva

Prime 60Hz 18 kw / 18 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings Prime Ratings kw/kva 240MONO / / 18

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime 60Hz 91 kw / 114 kva

Prime Hz 400 kw / 500 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime 60Hz 55 kw / 68 kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime 60Hz 155 kw / 193 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva. Prime Ratings kw/kva 240MONO / 10 9 / 9

Prime 60Hz 455 kw / 568 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime 60Hz 273 kw / 341 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings 1 kw/kva

ENGINE DATA. 205L/s [434cfm] 565 C [1049 F] 750mm CE [30in. WG

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings 1 kw/kva

Type Dimensions Weight Tank Length: 6400mm 7836kg [17275lbs] [252in] Net 930 L 9020kg [19886lbs] Heigth: 2721mm Gross [107in]

Type Dimensions Weight Tank Length: 6400mm 8709kg [19200lbs] [252in] Net 930 L 10000kg [22046lbs] Heigth: 2721mm Gross [107in]

TERM OF USE Standard reference conditions ESP/PRP 25 C /25 C Air Intlet Temp, 1000 m/1000 m m A.S.L. 60 % relative humidity.

Engine JOHN DEERE, 4045HFS83, U.S. EPA Tier 3 Alternator LEROY SOMER, LSA442VS45 <Debut> 100KW GENERATOR

TERM OF USE Standard reference conditions ESP/PRP 27 C /40 C Air Intlet Temp, 1000 m/1000 m m A.S.L. 60 % relative humidity.

Engine type Alternator type Canopy Type GENERAL CHARACTERISTICS

Engine type Alternator type Canopy Type GENERAL CHARACTERISTICS

Optional Control Panel POWER

K28H GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

K12. Optional Control Panel POWER K12

KM33. Frequency (Hz) Voltage (V) Standard control Panel Optional control panel Optional control Panel POWER

T16K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

J80UC3 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

J200UC3 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KM44. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel POWER

K20UM POWER 240 MONO-BI

KV550C2. Optional control panel POWER

V550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V500UC2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V700C2. Optional Control Panel POWER. Voltage. DIMENSIONS COMPACT VERSION 24 V charge alternator and starter

ENGINE CHARACTERISTICS

J60U GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

J220K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

T1400. Standard Control Panel POWER. Voltage. kw e 415/24 400/23 380/22

D330 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KK44 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

X1100C GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE

Optional control panel POWER. Voltage

KD165. Engine type Alternator type Performance class. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel

K17M POWER 240 MONO 230 MONO 220 MONO

J66K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KX1100. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel Optional control panel POWER

J165K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KH275. Frequency (Hz) Optional control panel POWER. Voltage

K26M POWER 240 MONO 230 MONO 220 MONO

GZ40 POWER. Fuel System 50 Hz:

KV500C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION. Soundproof version with CE directive (CN09 option) Type soundproofing

V550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KV550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V275C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

X800 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

GZ25 POWER. Fuel System 50 Hz:

KV550C2. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel Optional control panel POWER

V550C2 GENERAL CHARACTERISTICS POWERS DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KV500UC2. Frequency (Hz) Voltage (V) Standard Control Panel Optional control panel Optional control panel Optional control panel POWER

KM2500. Engine type Alternator type Performance class

GZ50 POWER. Fuel System 50 Hz:

V500UC2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

Réf GB / e ALTERNATORS. LSA Pole. Electrical and mechanical data

G50U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

DIESEL GENERATOR SET. 60 Hz FEATURES

60 Hz FEATURES. Exclusively from your Caterpillar dealer

G100U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

DIESEL GENERATOR SETS

60 Hz FEATURES. Exclusively from your Caterpillar dealer

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

USP&E Cummins Series Diesel Generator Set

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

G80U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

50 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

GEH250 (3-Phase) 50 HZ. 230 kva / 184 kw FEATURES. Exclusively from your Caterpillar dealer

STANDBY 200 ekw 250 kva

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 880 ekw 1100 kva 50 Hz 1500 rpm 400 Volts

GEP50-3 (3-Phase) 50 HZ kva / 40.0 kw 60 HZ kva / 45.0 kw FEATURES. Exclusively from your Caterpillar dealer

GEP110 (3-Phase) 50 HZ. 100 kva / 80 kw 60 HZ. 113 kva / 90.4 kw FEATURES. Exclusively from your Caterpillar dealer

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

STANDBY 200 ekw 250 kva

GEP30 (3-Phase) 50 HZ. 27 kva / 21.6 kw 60 HZ. 30 kva / 24.0 kw FEATURES. Exclusively from your Caterpillar dealer

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 400 Volts

Standby 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

C18. STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts

GEPH17SP (1-Phase) 50 HZ 17.5 kva / 17.5 kw FEATURES. Exclusively from your Caterpillar dealer

Transcription:

TM20K MODEL DIESEL GENSET TM20K Stand-by Power @ 50Hz 18kW / 22 kva Prime Power @ Hz 16 kw / 20 kva Standard Features General features : Engine (MITSUBISHI, S4Q2.SD ) Charge alternator 12 V, Governor:Meca/Mechanical Alternator (MECC ALTE, ECO 28 1L/4 ) Single bearing alternator IP 23, insulation class H /H Radiator 50 C [122 F] C max. T air inlet with coolant cap Skid and vibration isolators Dry type air filter Main line circuit breaker Microprocessor control panel 12 V battery, rack and cable Industrial silencer (loose) User manual Generator Ratings Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva Prime Ratings kw/kva 415/240 50 3 0.8 31 18 / 22 16 / 20 400/230 50 3 0.8 32 18 / 22 16 / 20 380/220 50 3 0.8 33 18 / 22 16 / 20 240/120 50 3 0.8 53 18 / 22 16 / 20 230/115 50 3 0.8 55 18 / 22 16 / 20 220/110 50 3 0.8 58 18 / 22 16 / 20 220/127 50 3 0.8 52 16 / 20 14 / 18 200/115 50 3 0.8 64 18 / 22 16 / 20 Stand-By ratings are available for the duration of any power outage. No overload capacity is specified at this ratings. Prime ratings are available per BS 5514, DIN 6271, ISO-3046 and IEC 34-1 with 10% overload capacity one hour in twelve hours. Conditions of sale SDMO provides a full line of products with high quality recognized engines and alternators. Service and parts are available from SDMO distributors as a single source of responsibility. Each and every units is factory tested. All generator sets are also prototype tested. Two years limited warranty, please refer to the conditions terms. Five years extended are also available.

ENGINE DATA Manufacturer / Model Cylinder Arrangement Displacement Bore and Stroke Compression ratio Rated RPM Piston Speed Max. stand by Power at rated RPM Frequency regulation, steady state BMEP Governor : type Exhaust gas flow Exhaust temperature Max back pressure Exhaust System Fuel System 110% (Stand By power ) 100% (of the Prime Power) 75% (of the Prime Power) 50% (of the Prime Power) Total fuel flow Oil System Total oil capacity w/filters Oil Pressure low idle Oil Pressure rated RPM Oil consumption 100% load Oil capacity carter Thermal balance 100% load Heat rejection to exhaust Radiated heat to ambiant Heat rejection to coolant Air intake Max. intake restriction Engine air flow Coolant System Radiator & engine capacity Max water temperature Outlet water temperature Fan power Fan air flow Available restriction on air flow Type of coolant Thermostat Emissions HC CO Nox PM MITSUBISHI S4Q2.SD, 4-cycle, Athmo, N/A 4 X L 2.50L [152.6C.I.] 88mm [3.5in.] X 103mm [4.1in.] 22 : 1 1500 Rpm 5.15m/s [16.9ft./s] 23.87kW [32BHP] +/-2. 5% 6.92bar [100psi] Meca/Mechanical 74L/s [157cfm] 600 C [1112 F] 680mm CE [27in. WG] 6.8L/h [1.8gal/hr] 6.2L/h [1.6gal/hr] 4.7L/h [1.2gal/hr] 3.4L/h [0.9gal/hr] 36L/h [9.5gal/hr] 6.5L [1.7gal] 1bar [14.5psi] 5bar [72.5psi] 0.06L/h [0.0gal/hr] 5.5L [1.5gal] 21kW [1194Btu/mn] 3kW [171Btu/mn] 19kW [1080Btu/mn] 200mm CE [8in. WG] 29L/s [61cfm] 8.1L [2.1gal] 111 C [232 F] 93 C [199 F] 0.8 kw 0.8m3/s [1695cfm] 10mm CE [0.4in. WG] Gencool 76.5-90 C 30 mg/nm3 290 mg/nm3 1020 mg/nm3 120 mg/nm3

ALTERNATOR SPECIFICATIONS GENERAL DATA Compliance with NEMA MG21, UTE NF C51.111, VDE 0530, BS 4999, CSA standards. Vacuum-impregnated windings with epoxy varnish. IP21 drip proof. ALTERNATOR DATA Manufacturer / Type Number of phase Power factor (Cos Phi) Altitude Overspeed Pole : number Exciter type Insulation : class, temperature rise Voltage regulator Sustained short circuit current Total harmonics (TGH/THC) Wave form : NEMA = TIF TGH/THC Wave form : CEI = FHT TGH/THC Bearing : number Coupling Voltage regulation 0 to 100% load Recovery time (20% Volt dip) ms SkVA with 90 % of nominal sustained voltage (at 0.4 PF) MECC ALTE ECO 28 1L/4 3 0.8 1000 rpm 4 No H / H AVR 1 Direct ms N/A OTHER ALTERNATOR DATA Continuous nominal rating @ 40 C Standby rating @ 27 C Efficiencies @ 4/4 load Air flow Short circuit ratio;50 (Kcc) Direct axis synchro reactance unsaturated (Xd) Quadra axis synchro reactance unsaturated (Xq) Open circuit time constant;50 (T do) Direct axis transient reactance saturated (X d) Short circuit transient time constant (T d) Direct axis subtransient reactance saturated (X d) Subtransient time constant (T d) Quadra axis subtransient reactance saturated (X q) Zero sequence reactance unsaturated (Xo) Negative sequence reactance saturated (X2) Armature time constant (Ta) No load excitation current (io) Full load excitation current (ic) Full load excitation voltage (uc) Recovery time (Delta U = 20% transitoire) Motor start (Delta = 20% perm. Or 50% trans.) Transient dip (4/4 charge) PF : 1.8 AR No load losses Heat rejection kva 24.2 kva 84.2 % 5.5m3/s [11653.79cfm] 0.65 175 % 76 % 0.87 ms 16.5 % 0.045 ms 9.4 % 0.015 ms 21 % 3.2 % 14.2 % 0.013 ms A A V ms kva % kw kw

Control Panels NEXYS Specifications :Frequency meter, Ammeter, Voltmeter Alarms and faults Oil pressure, water temperature, Overcrank, Overspeed, Min/max alternator, Low fuel level, Emergency stop Engine parameters Hours counter, Engine speed, Battery voltage, Fuel level, AIr preheating TELYS Specifications :Frequency meter, Ammeter, Voltmeter Alarms and faults Oil pressure, water temperature, No start-up, Overspeed, Min/max alternator, Min/max battery voltage, Low fuel level, Emergency stop Engine parameters Hours counter, Oil pressure, Water temperature, Engine speed, Battery voltage, Fuel level

Options Engine and Radiator Alternator Control panel Anti condensation heater NFPA 110 level 1 Heat shield protection Enforced impregnation Paralleling system Oil drain extension Oversized alternator Remote annunciator Heavy duty air filter Oil temperature shutdown Lube oil drain pump Exhaust Key start panel Radiator core guard Residential silencer Literature Battery charger Critical silencer Parts Block heater Flexible exhaust conn. Maintenance Fuel Enclosure M107 Day tank Silent 61 db @ 23 Ft (stby) Subbase fuel tanks UL Water separator fuel filter Weight and Dimensions Open Model Overall size l x w x h : 1425mm [56in] x 780mm [31in] x 1055mm [42in] Weight : 530kg [1168lbs] Net 630kg [1389lbs] Brut With Optional Enclosure Overall size l x w x h : 2100mm [83in] x 920mm [36in] x 1445mm [57in] Weight : 845kg [1862lbs] Net 945kg [2083lbs] Brut

SDMO industries - Head Office 12bis, rue de la Villeneuve CS 92848-29228 BREST cedex 2 - FRANCE - www.sdmo.com