Parts Certificate Certificate for a part of a measuring system for LOTW

Similar documents
Evaluation Certificate

Evaluation Certificate

Parts Certificate. Outdoor Payment Terminal KT-OPT - including KT-Retail and KT-Account SC

Evaluation Certificate Certificate for a part of a measuring system for LOTW

EC type Examination Certificate

Parts Certificate Certificate for a part of a measuring system for LOTW No. SC

WELMEC European cooperation in legal metrology

EC Type-Approval Certificate UK2853 Revision 4

EC Type-Approval Certificate UK 2655 Revision 2

WELMEC External Auxiliary Power Supply of Electrical Energy Meters

Certificate of EC type-approval of a measuring instrument Number: UK 2489 Revision 4

EC type-examination certificate UK/0126/0072 Revision 2

EC type Examination Certificate

EU-type examination Certificate

EU-type examination Certificate

OIML CERTIFICATE OF CONFORMITY

Committee Chair, National Type Evaluation Program Committee Issued: December 27, M Street, Suite 110 / Lincoln, Nebraska 68508

EU-TYPE EXAMINATION CERTIFICATE

OIML CERTIFICATE OF CONFORMITY

OIML CERTIFICATE OF CONFORMITY

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

Tillers Motor hoes (combustion engine powered)

The Council Directive 2009/23/EC on non-automatic weighing instruments.

Chain-saws (combustion engine powered)

EU-type examination Certificate

Hedge trimmers (combustion engine powered)

Ride-on lawnmowers (combustion engine powered)

Certificate of constancy of performance

C e r t i f i c a t e

QUICK REFERENCE MANUAL

A brief guide for identification of non-compliant construction machinery. Is this. Compactor / Roller compliant with European legislation?

US-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability

OIML CERTIFICATE OF CONFORMITY

English version of. Executive Order on vehicles' technical compatibility with the rail network (Bekendtgørelse nr af 30. november 2012) Preface

Pattern evaluation programs for traffic speed measurement devices in PR China

WELMEC. European Cooperation in Legal Metrology

WSTH/WPTH. Woltmann type combined energy meter. Measuring distance. Function. Connection. High reliability. Mounting.

COMMISSION REGULATION (EU) / of XXX

Metering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series

Heat Meter Integrator

EU TOY DIRECTIVE 2009/48/EC: OVERVIEW - REGULATORY CONTEXT AND MAJOR CHANGES

issued by Notified Body No according to 2014/32/EU MID FULL QUALITY ASSURANCE Module H

COMMISSION REGULATION (EU)

Diploma in Consumer Affairs and Trading Standards LEGAL METROLOGY LAW NOVEMBER 2014

PORTABLE AXLE WEIGHING SYSTEM CET 10-4 IN STATIC MODE TRUCKS OVERLOAD CONTROLS EUROPEAN APPROVED

IFX-M4-03 IFX-M4-03_D_E_2017_05_REV.0

Usb data loggers for cold chain monitoring

The Participant will select one of the two Approval Categories (below) and submit the appropriate documentation.

COMMISSION REGULATION (EU)

EBI 3x0 PDF Data Loggers

Vehicle Weighing. Vehicle Weighing Solutions. That help drive your business. Vehicle Weighing Solutions

CERTIFICATE. Solar Keymark Certificate No. SP SC

DC Energy Measurement for EV Charging Stations

EU Mutual Recognition Technical Requirements

EUROPEAN UNION AGENCY FOR RAILWAYS Annex 1 006REC1025 V 1.0

Informal document No. 2

UK Weighing Federation Technical Articles

DECLARATION OF PERFORMANCE DoP N EN

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Screw-type and measuring capsule heat meter with IrDA interface and an interface for retrofitting external modules or with integrated communication.

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

Version / Status V 2.0 Date Author. Wagon Markings

SensoStar C. Installation and Operating Instructions Heat Meter Calculator Heat/Cooling Meter Calculator Cooling Meter Calculator

Rosemount 3095FC MultiVariable Mass Flow Transmitter with MODBUS Protocol

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.

12468/10 SJC/fp 1 DG I 1A

Excellence Level. XPR Precision Balances Accurate, Flexible, Compliant. XPR Precision Balance Solutions Go Beyond Weighing

Superstatic 440. Static Heat- and Cooling Meter. Application

EUnited Municipal Equipment

COMMISSION RECOMMENDATION. of XXX

Proposal for a DIRECTIVE OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL

CEN and CENELEC Position Paper on the European Commission s proposal for a Directive on the deployment of alternative fuels October 2013

VOLUNTARY CODE OF PRACTICE FOR ELECTROMAGNETIC COMPATIBILITY (EMC) OF MOTOR VEHICLES (13 October 2014)

WAYNE FUSION FORECOURT SYSTEM. Meet the new face of. forecourt control.

Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop.

Communicator Installation Sheet. Version 1.0.1

FUNCTIONS AND TECHNOLOGY OF DIGITAL TACHOGRAPHS SYSTEMS WITH CONTEMPORARY TELEMATIC SYSTEM IN ROAD TRANSPORT, ON BOARD INFORMATICS NET AND GPS SYSTEM

CONNECTED SERVICEs TACHOGRAPH SOLUTIONS

ETSI EN V1.2.1 ( ) Harmonized European Standard (Telecommunications series)

These documents contain additional information concerning related products from Rockwell Automation.

Information for the Certification of Weld Shops in Rail Vehicle Construction According to DIN EN

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Hybex Microsample Incubator

Temperature multi-function calibrator Model CTM

E-15 Uninterruptible Power Systems (UPS)

Official Journal L 012, 18/01/2000 P

Mini Pressure Transmitter HA7

BLU SERIES Battery Load Units

WSTH/WPTH. Woltmann type combined energy meter. Woltmann flow meters for large nominal flows combined with calculator and temperature sensors.

ECE/RCTE/CONF/4/Add.1/Rev.2

National comparison on verification of fuel dispensers

Data sheet MULTICAL 6L2. Data loggers Info loggers Data backup in case of power failure MID-2004/22/EC EN 1434

Bitte decken Sie die schraffierte Fläche mit einem Bild ab. Please cover the shaded area with a picture. (24,4 x 11,0 cm)

(Non-legislative acts) DECISIONS

CETOP POSITION PAPER PP 07

F5 565 Rear-view mirrors (ENTR/2004/1340)

World Light duty Test Procedures: Fiction or Reality?

WAYNE IX FLEET FUEL CONTROL SYSTEM Advanced in-dispenser fl eet fueling control

STAPS Wireless Steam Trap Monitoring System

Ulyser Component Maintenance Manual

Transcription:

No. 107030 Wayne ixpay TX secure payment platform, a payment terminal (OPT) for cards Issued to Wayne Fueling Systems Sweden AB Hanögatan 10, SE-211 24 Malmö, Sweden In respect of (part of instrument) Payment terminal device for cards intended for use with fuel dispensers for motor vehicles. Characteristics/rated operating conditions The evaluated part of a measuring system for liquids other than water (LOTW) is a self-service device (SSD) for direct sales, interruptible, unattended delayed payment including a printer. Accuracy class: 0,5 In accordance with - WELMEC Guide 8.8, Issue 2 General and Administrative Aspects of the Voluntary System of Modular Evaluation of Measuring instruments under the MID, - WELMEC Guide 10.7, Issue 1 Guide on evaluating purely digital self-service devices (PDSSD) for sales to the public and - WELMEC Guide 7.2, Issue 2015 Software Guide. This Parts Certificate is the positive result of the applied modular approach under these WELMEC Guides, for a part of a measuring system for the continuous and dynamic measurement of quantities of liquids other than water. This is not a MID Certificate (EU-type examination certificate according to 2014/32/EU), but the MID requirements have been applied. The complete measuring system shall be subject to a conformity assessment procedure as described in MID. This Parts Certificate is free to use by manufacturers of complete measuring instruments. Applicable essential requirements MID 2014/32/EU - MID, Annex I, Essential requirements - MID, Annex MI-005, Measuring systems for the continuous and dynamic measurement of quantities of liquids other than water (LOTW) 8 pages where this is page 1 6P04910

No. 107030 Harmonised standards and normative documents used Applicable parts of the following normative documents referred to in the Official Journal of the European Union 2011/C33/01: - OIML R 117-1 Edition 2007 (E), Dynamic measuring systems for liquids other than water Further applied documents: - The Measuring Instruments Regulation, STAFS 2016:1 - Regulations and Guidelines concerning Measuring Systems for the Continuous and Dynamic Measurement of Quantities other than Water, STAFS 2016:6 - SP s Certification Rules SPCR 181 Validity Valid until November 17, 2026. Miscellaneous This issue of the certificate is the first edition. The principal characteristics, approval conditions are set out in the appendix hereto, which forms part of the approval document. All the plans, schematic diagrams and documentations are recorded under reference file 6P04910. The evaluation report 6P04910-1 has been issued in accordance with WELMEC Guide 8.8, Voluntary system of Modular Evaluation. Borås November 17, 2016 Certification Lennart Aronsson Product Certification Manager Kerstin Mattiasson Certification Officer 8 pages where this is page 2 6P04910

0 Conditions The use of this Parts Certificate is limited to combination with any fuel dispenser/ssd under the following conditions: - The communication protocols defined in this certificate are used - The fuel dispenser/ssd having an EC-type examination certificate covering compatibility with the communication protocol used - The SSD having an Evaluation or Parts Certificate covering compatibility with the communication protocol used - The fuel dispenser/ssd having a National Type approval covering compatibility with the communication protocol used The device must correspond with the following specifications: 1 Design of the device 1.1 Construction Payment terminal description Wayne ixpay TX secure payment platform is a family of outdoor payment terminals (OPT) where X stands for the screen size. For example Wayne ixpay T7 is a Wayne ixpay TX with a 7 inch screen. The payment terminal is a part of a self-service arrangement. It supports the following service mode and type of payment: Attended post-payment Attended pre-payment Unattended delayed-payment Unattended pre-payment Wayne ixpay TX payment terminal X The payment terminal is a self-service device for unattended delayed payment (card), direct sales, in an interruptible measuring system. It includes a printing device. It does not include a memory device. The payment terminal is peripheral and connected to a site controller/point of sale system (master) through serial communication, multi-drop link. Physical link is LAN/Ethernet serial communication. It can be single or double-sided. It can be mounted in both Wayne or competitors fuel dispensers, (Picture 1 and 2). It can also be a separate device, mounted on a freestanding column (Picture 3). 8 pages where this is page 3 6P04910

Picture 1: Wayne ixpaytx installed in Wayne Helix 2000 Fuel dispenser Picture 2: Wayne ixpay TX installed in Wayne Global Star Picture 3: ixpay TX mounted on freestanding column 1.2 Components included in Wayne ixpay TX secure payment platform The hardware of the self-service device should comply with the EMC-directive and other applicable directives as specified in the Declaration of Conformity of the self-service device. Components included in all variants Operating system Microsoft Windows Embedded CE 6.0 Legally relevant software checksum ixpay TX 4F97F400 Contactless reader (0, 2 pcs) XAC C150W (WU012781-0001) Printer (1, 2 pcs) Zebra Technologies KR203e (WU006648-000X) or equivalent, with CE-marking and suitable climate specification, tested by Wayne under the condition that the functionality of the checking facilities for power off, decoupling/no serial communication, end of paper, is the same. Display (1, 2 pcs) Ethernet switch (0, 1 pc) Wayne WU013696-0001 DISPLAY MODULE SECURE, 7" WVGA Wayne WU007300-0001 Heater (1 pc) Wayne WM044405 (DBK Typhoon 40-290, 290 W, 10 C, switch = E) BOARD POWER PT4000 ASS'Y (+12V) (1 pc) Wayne WM017290-0002 8 pages where this is page 4 6P04910

Pin-pad, including payment security function (0, 2 pcs) SPM2 (WU012497-0004) XAC Automation Corp Card reader (0, 2 pcs) XAC P90 (WU012595-0001) XAC Automation Corp Components included when installed in freestanding column Power supply (1pc) Channel Well Tech. UAS150B (WM027313-0001) or equivalent with CE-marking and suitable climate specification and tested by Wayne 1.3 Optional equipment and functions subject to MID requirements Not applicable 1.4 Technical documentation For market surveillance the construction and included components are described in 1.1 and 1.2. The metrological software is identified by the print data checksum (W&M CRC value), which can be accessed according to 5.3. 1.5 Integrated equipment and functions not subject to MID Not applicable 2 Technical data 2.1 Rated operating conditions Payment terminal device for cards, intended for use with fuel dispensers for motor vehicles. Self service device for direct sales, interruptible, unattended delayed payment including a printer. Measurement range Scale interval, printed volume Scale interval, printed price Accuracy class of measuring system 0,5 or 1,0 2.2 Other operating conditions Not applicable same as dispenser, but not smaller than 0,01 l same as dispenser, but not smaller than 0,01 PRICE 8 pages where this is page 5 6P04910

3 Interfaces and compatibility conditions Communication with other parts of a measuring system (e g POS-systems) using one of the following protocols: TCP/IP XML Installation: Shielded communication cable with screen connected in both ends SW protocol TCP/IP Hardware LAN PORT The payment terminal may only be used in a measuring system with: all volume indicating and memory devices having the same scale interval as ixpay TX all price indicating and memory devices having the same scale interval as ixpay TX a memory device on which measurement data are registered (OIML R117-1 (2007), 5.10.3.1.1, 5.10.3.1.5, 5.10.3.2) a function that sends warnings from the checking facilities to the payment terminal for presentation on the display (OIML R117-1 (2007), 5.10.3.1.2) 4 Requirements on production, putting into use and utilisation 4.1 Requirements on production 4.2 Requirements on putting into use Functional test of system link and printer may be performed in the factory according to Wayne Manufacturing Test requirement specification. 4.3 Requirements for consistent utilisations 5 Control of the measuring tasks of the device in use 5.1 Documentation of the procedure 5.2 Special equipment or software, if applicable 5.3 Identification of - Hardware The construction and included components are described in 1.1 and 1.2. 8 pages where this is page 6 6P04910

- Software The legally relevant software is identified by the checksum (W&M CRC value, see 1.2). The checksum is printed on a MID validation receipt. To print a MID validation receipt: Enter Run Time Diagnostics mode by: For terminals with touch screen, press upper left corner, lower left corner in sequence, with maximum 2 seconds between each key press. For terminals with soft keys pressing key 2 and 6 simultaneously. Press MID Checksum MID Checksum is calculated Press print Receipt with MID checksum is printed. Press exit. All legally relevant data on a sales receipt are surrounded by. 5.4 Calibration-/adjustment procedure Not applicable 6 Security measures 6.1 Sealing The payment terminal is not sealed. 6.2 Data logger The payment terminal may only be used in a measuring system with a memory device on which measurement data are registered (OIML R117-1 (2007), 5.10.3.1.1, 5.10.3.1.5, 5.10.3.2). 7 Labelling and inscriptions 7.1 Information to be borne by and to accompany the device The marking plate/label mounted on the device shall contain the following information: - the name and address of the manufacturer - the serial number of the payment terminal and year of manufacture - the designation or type name - the Parts Certificate number, 107030, of the payment terminal - the ambient temperature range - mechanical class - electromagnetic class - place for identification of the connected fuel dispenser(s) - place for the verification sticker 8 pages where this is page 7 6P04910

7.2 Conformity marking in accordance to MID article 17 This Parts Certificate is not an EC-type examination Certificate. Therefore the payment terminal must not be marked with the supplementary metrology marking M xx, following the CE marking. 7.3 Further inscriptions, if necessary 7.4 Evaluations carried out for this Parts Certificate The evaluation under this certificate is recorded in Evaluation Report 6P04910-1 (referring to test and examinations in test report 6P00235-1, ). A summary of the evaluation under this certificate is given below. Description + - Remarks Relevant parts of the checklist OIML R117-1 6P00235-1 Extension Description + - Remarks Type P Requirements on / / basic configuration Type U Requirements on basic configuration Extension L Requirements on data storage Extension T Requirements on interfaces Extension S Requirements on software separation Extension D Requirements on software download Extension I Specific software / / requirements 8 pages where this is page 8 6P04910